RESUMEN
Background: Six Sigma is a popular quality management system that enables continuous monitoring and improvement of analytical performance in the clinical laboratory. We aimed to calculate sigma metrics and quality goal index (QGI) for 17 biochemical analytes and compare the use of bias from internal quality control (IQC) and external quality assurance (EQA) data in the calculation of sigma metrics. Methods: This retrospective study was conducted in Marmara University Pendik E&R Hospital Biochemistry Laboratory. Sigma metrics calculation was performed as (TEa-bias)/CV). CV was calculated from IQC data from June 2018 - February 2019. EQA bias was calculated as the mean of % deviation from the peer group means in the last seven surveys, and IQC bias was calculated as (laboratory control result mean-manufacturer control mean)/ manufacturer control mean) x100. In parameters where sigma metrics were <5; QGI=bias/1.5 CV) score of <0.8 indicated imprecision, >1.2 pointed inaccuracy, and 0.8-1.2 showed both imprecision and inaccuracy. Results: Creatine kinase (both levels), iron and magnesium (pathologic levels) showed an ideal performance with ≥6 sigma level for both bias determinations. Eight of the 17 parameters had different sigma levels when we compared sigma values calculated from EQA and IQC derived bias% while the rest were grouped at the same levels. Conclusions: Sigma metrics is a good quality tool to assess a laboratory's analytical performance and facilitate the comparison of the assay performances in the same manner across multiple systems. However, we might need to design a tight internal quality control protocol for analytes showing poor assay performance.
RESUMEN
BACKGROUND: The availability of a reliable reference interval is crucial for clinical decision-making. Correctly defined reference intervals for different age groups are currently unavailable for many parameters. Our study aimed to determine the complete blood count reference intervals in our region from newborn to geriatric ages with an indirect method. METHODS: The study was carried out at Marmara University Pendik E&R Hospital Biochemistry Laboratory between January 2018 and May 2019 using the laboratory information system data. The complete blood count (CBC) measurements were performed by Unicel DxH 800 Coulter Cellular Analysis System (Beckman Coulter, FL, USA). A total of 14,014,912 test results belonging to infants, children, adolescents, adults, and geriatric ages were collected. We analyzed 22 CBC parameters, and an indirect method was used for reference interval determination. Data were analyzed according to the Clinical and Laboratory Standards Institute (CLSI) C28-A3 guideline for defining, establishing, and verifying reference intervals in the clinical laboratory. RESULTS: We have established reference intervals from newborn to geriatric ages for 22 hematology parameters [hemoglobin (Hb), hematocrit (Hct), red blood cell (RBC), mean red cell volume (MCV), mean red cell hemoglobin (MCH), mean red cell hemoglobin concentration (MCHC), red cell distribution width (RDW), white blood cell (WBC) count, WBC differentials, including percentages and absolute counts, platelet count, platelet distribution width (PDW), mean platelet volume (MPV) and plateletcrit (PCT)]. CONCLUSIONS: Our study showed that reference intervals established with data obtained from clinical laboratory databases are comparable to those created using direct methods.
Asunto(s)
Índices de Eritrocitos , Laboratorios de Hospital , Recién Nacido , Adolescente , Niño , Lactante , Adulto , Humanos , Anciano , Recuento de Células Sanguíneas , Hematócrito , Recuento de LeucocitosRESUMEN
INTRODUCTION: Sepsis, defined as an increase of 2 points or more in the sequential organ failure assessment score, is a life-threatening organ dysfunction caused by the dysregulated host response to infection. Volume-conductivity-scatter (VCS) parameters of cell counters which are known as cell population data (CPD) have been suggested to be beneficial in diagnosing sepsis. We aimed to evaluate the diagnostic value of CPD parameters in sepsis in comparison to nonsystemic infection cases (NSI) and non-infectious acute and chronic inflammatory conditions. MATERIALS AND METHODS: We prospectively included four groups of patients" data: sepsis (n = 66), localized infection (pneumonia, n = 59), chronic inflammation (rheumatoid arthritis, n = 92) and noninfectious inflammation (coronary artery bypass graft operation, n = 56) groups, according to their clinical status and laboratory results. Samples for cell counting and serum markers were collected on the same day of culture collection. VCS parameters were measured by Unicel DxH800 Coulter Cellular Analyzer (Beckman Coulter, USA). RESULTS: Mean neutrophil volume (MN-V-NE), was highest in the sepsis group [155(149-168)] compared to the localized infection [148(140-158)], chronic inflammation [144.5(142-149)] and noninfectious inflammation [149(145.2-153.7)] (P = 0.001, P < 0.001, P < 0.001, respectively). Neutrophil volume SD (SD-V-NE) was higher in the sepsis [21(18.8-23.7)], significantly differentiating sepsis from other groups. The area under curves of procalcitonin and hs-C-reactive protein were 0.846 and 0.837, respectively, in the receiver-operating characteristic curves (ROC) . CPD combinations, (SD-V NE + SD-V LY + SD-V MO), (SD-V NE + SD-V MO), and (MN-V NE + SD-V NE + SD-C LY + SD-V MO) had greater AUC values than procalcitonin's. CONCLUSION: VCS parameters might be promising for differentiating sepsis and non-sepsis cases. Additionally, obtaining these data routinely makes their prospects promising without any additional cost and time.
Asunto(s)
Polipéptido alfa Relacionado con Calcitonina , Sepsis , Humanos , Infección Persistente , Sepsis/diagnóstico , Neutrófilos , Curva ROC , Inflamación , Pronóstico , Estudios RetrospectivosRESUMEN
BACKGROUND: Considering the changes in thyroid physiology associated with pregnancy and poor outcomes related to abnormal maternal thyroid function, international guidelines recommend using population-based trimester-specific reference intervals (RIs) for thyroid testing. If these RIs are not available in the laboratory, implementing recommended fixed cut-off values globally is still controversial. To address this issue, we aimed to establish appropriate RI of thyroid-stimulating hormone (TSH) in pregnant Turkish women for our laboratory and compare the prevalence of thyroid dysfunction based on the established and recommended criteria. METHODS: Of 2638 pregnant women, 1777 women followed in the obstetric outpatient were enrolled in the reference interval study after applying exclusion criteria related to medical and prenatal history. A retrospective study was conducted by collecting data from July 2016 to March 2019. Serum TSH was measured by UniCel DxI 800 Immunoassay System (Beckman Coulter Inc., Brea, CA, USA). The study design relied on two approaches in order to classify pregnant women: trimester-specific and subgroup-specific; the latter involved dividing each trimester into two subgroups: T1a, T1b, T2a, T2b, T3a, T3b. The lower and upper limits of the RIs were derived by the parametric method after normalizing the data distribution using the modified Box-Cox power transformation method. RESULTS: The lowest TSH value was detected at 8-12 weeks in early pregnancy, and the median value of TSH in the T1b subgroup was significantly lower than the T1a subgroup (P < 0.05). TSH levels showed a gradual trend of increase along with the pregnancy and increased significantly in the T2a, T2b, and T3b subgroups compared to the preceding subgroups (P < 0.05). Compared to the diagnostic criteria recommended by American Thyroid Association (ATA), the prevalence of thyroid dysfunction was significantly different from the established trimester- and subgroup-specific RIs throughout the pregnancy (P < 0.001). CONCLUSIONS: We conclude that establishing gestation- and laboratory-specific RIs, especially for TSH, is essential for diagnosing thyroid disorders in pregnancy, and the recommended universal cut-off values, which may contribute to the risk of a misdiagnosis or a missed diagnosis, should be taken with caution in the clinical setting. However, regarding the fluctuation of thyroid function tests throughout pregnancy, trimester-specific RIs are insufficient, and implementing split phases is required.
Asunto(s)
Enfermedades de la Tiroides , Tirotropina , Femenino , Humanos , Embarazo , Estudios Retrospectivos , Enfermedades de la Tiroides/diagnóstico , Enfermedades de la Tiroides/epidemiología , TiroxinaRESUMEN
Low serum alkaline phosphatase (sALP)-hypophosphatasemia-is a characteristic of hypophosphatasia (HPP), but related to several clinical conditions. Here, we evaluated the frequency, persistency and the etiology of hypophosphatasemia in children. In retrospective analyses of sALP measurements from children, evaluated according to in-house constructed age- and sex-specific reference ranges, patients with no normal sALP measurement (Unresolved hypophosphatasemia) were invited for reanalysis. Prospectively, ALP substrates, pyridoxal-5-phosphate (PLP), and phosphoethanolamine (PEA) were measured in patients with persistent hypophosphatasemia. Radiographs and ALPL gene sequencing for HPP were performed to the cases with elevated PEA and/or PLP. From 130,340 sALP measurements of 93,162 patients, hypophosphatasemia was detected in 1404 samples from 867 patients (0.9%). Among them, 745 had at least one normal sALP values in laboratory records, grouped as transient hypophosphatasemia. 75 out of 122 patients with unresolved hypophosphatasemia could be reanalyzed for sALP, of whom PLP and PEA measurements were required in 37 due to persistent hypophosphatasemia. Both PEA and PLP were elevated in 4 patients, and ALPL gene analysis showed heterozygous mutations in 3 patients and homozygous in 1 patient. Elevated PEA with normal PLP were detected in 3 patients, and one had a heterozygous ALPL mutation. Anemia was the most common diagnosis, and upper respiratory tract infections and chronic diseases were more common in transient and unresolved hypophosphatasemia, respectively. In conclusion, reflected persistent hypophosphatasemia frequency was 1/1552 (0.06%) in this large pediatric cohort and, ALPL gene mutations were detected in 13.5% (5/37) of the studied cases. Although biochemical hypophosphatasemia is not uncommon, clinically significant HPP is rare.