Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
Radiology ; 313(1): e240237, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39377678

RESUMEN

Background Mammographic background characteristics may stimulate human visual adaptation, allowing radiologists to detect abnormalities more effectively. However, it is unclear whether density, or another image characteristic, drives visual adaptation. Purpose To investigate whether screening performance improves when screening mammography examinations are ordered for batch reading according to mammographic characteristics that may promote visual adaptation. Materials and Methods This retrospective multireader multicase study was performed with mammograms obtained between September 2016 and May 2019. The screening examinations, each consisting of four mammograms, were interpreted by 13 radiologists in three distinct orders: randomly, by increasing volumetric breast density (VBD), and based on a self-supervised learning (SSL) encoding (examinations automatically grouped as "looking similar"). An eye tracker recorded radiologists' eye movements during interpretation. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of random-ordered readings were compared with those of VBD- and SSL-ordered readings using mixed-model analysis of variance. Reading time, fixation metrics, and perceived density were compared using Wilcoxon signed-rank tests. Results Mammography examinations (75 with breast cancer, 75 without breast cancer) from 150 women (median age, 55 years [IQR, 50-63]) were read. The examinations ordered by increasing VBD versus randomly had an increased AUC (0.93 [95% CI: 0.91, 0.96] vs 0.92 [95% CI: 0.89, 0.95]; P = .009), without evidence of a difference in specificity (89% [871 of 975] vs 86% [837 of 975], P = .04) and sensitivity (both 81% [794 of 975 vs 788 of 975], P = .78), and a reduced reading time (24.3 vs 27.9 seconds, P < .001), fixation count (47 vs 52, P < .001), and fixation time in malignant regions (3.7 vs 4.6 seconds, P < .001). For SSL-ordered readings, there was no evidence of differences in AUC (0.92 [95% CI: 0.89, 0.95]; P = .70), specificity (84% [820 of 975], P = .37), sensitivity (80% [784 of 975], P = .79), fixation count (54, P = .05), or fixation time in malignant regions (4.6 seconds, P > .99) compared with random-ordered readings. Reading times were significantly higher for SSL-ordered readings compared with random-ordered readings (28.4 seconds, P = .02). Conclusion Screening mammography examinations ordered from low to high VBD improved screening performance while reducing reading and fixation times. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Grimm in this issue.


Asunto(s)
Neoplasias de la Mama , Mamografía , Humanos , Femenino , Mamografía/métodos , Persona de Mediana Edad , Estudios Retrospectivos , Neoplasias de la Mama/diagnóstico por imagen , Radiólogos , Sensibilidad y Especificidad , Competencia Clínica , Detección Precoz del Cáncer/métodos , Densidad de la Mama/fisiología
2.
ArXiv ; 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39314501

RESUMEN

Attenuation compensation (AC), while being beneficial for visual-interpretation tasks in myocardial perfusion imaging (MPI) by SPECT, typically requires the availability of a separate X-ray CT component, leading to additional radiation dose, higher costs, and potentially inaccurate diagnosis due to SPECT/CT misalignment. To address these issues, we developed a method for cardiac SPECT AC using deep learning and emission scatter-window photons without a separate transmission scan (CTLESS). In this method, an estimated attenuation map reconstructed from scatter-energy window projections is segmented into different regions using a multi-channel input multi-decoder network trained on CT scans. Pre-defined attenuation coefficients are assigned to these regions, yielding the attenuation map used for AC. We objectively evaluated this method in a retrospective study with anonymized clinical SPECT/CT stress MPI images on the clinical task of detecting defects with an anthropomorphic model observer. CTLESS yielded statistically non-inferior performance compared to a CT-based AC (CTAC) method and significantly outperformed a non-AC (NAC) method on this clinical task. Similar results were observed in stratified analyses with different sexes, defect extents and severities. The method was observed to generalize across two SPECT scanners, each with a different camera. In addition, CTLESS yielded similar performance as CTAC and outperformed NAC method on the metrics of root mean squared error and structural similarity index measure. Moreover, as we reduced the training dataset size, CTLESS yielded relatively stable AUC values and generally outperformed another DL-based AC method that directly estimated the attenuation coefficient within each voxel. These results demonstrate the capability of the CTLESS method for transmission-less AC in SPECT and motivate further clinical evaluation.

3.
Med Decis Making ; 44(7): 828-842, 2024 10.
Artículo en Inglés | MEDLINE | ID: mdl-39077968

RESUMEN

PURPOSE: To develop a model that simulates radiologist assessments and use it to explore whether pairing readers based on their individual performance characteristics could optimize screening performance. METHODS: Logistic regression models were designed and used to model individual radiologist assessments. For model evaluation, model-predicted individual performance metrics and paired disagreement rates were compared against the observed data using Pearson correlation coefficients. The logistic regression models were subsequently used to simulate different screening programs with reader pairing based on individual true-positive rates (TPR) and/or false-positive rates (FPR). For this, retrospective results from breast cancer screening programs employing double reading in Sweden, England, and Norway were used. Outcomes of random pairing were compared against those composed of readers with similar and opposite TPRs/FPRs, with positive assessments defined by either reader flagging an examination as abnormal. RESULTS: The analysis data sets consisted of 936,621 (Sweden), 435,281 (England), and 1,820,053 (Norway) examinations. There was good agreement between the model-predicted and observed radiologists' TPR and FPR (r ≥ 0.969). Model-predicted negative-case disagreement rates showed high correlations (r ≥ 0.709), whereas positive-case disagreement rates had lower correlation levels due to sparse data (r ≥ 0.532). Pairing radiologists with similar FPR characteristics (Sweden: 4.50% [95% confidence interval: 4.46%-4.54%], England: 5.51% [5.47%-5.56%], Norway: 8.03% [7.99%-8.07%]) resulted in significantly lower FPR than with random pairing (Sweden: 4.74% [4.70%-4.78%], England: 5.76% [5.71%-5.80%], Norway: 8.30% [8.26%-8.34%]), reducing examinations sent to consensus/arbitration while the TPR did not change significantly. Other pairing strategies resulted in equal or worse performance than random pairing. CONCLUSIONS: Logistic regression models accurately predicted screening mammography assessments and helped explore different radiologist pairing strategies. Pairing readers with similar modeled FPR characteristics reduced the number of examinations unnecessarily sent to consensus/arbitration without significantly compromising the TPR. HIGHLIGHTS: A logistic-regression model can be derived that accurately predicts individual and paired reader performance during mammography screening reading.Pairing screening mammography radiologists with similar false-positive characteristics reduced false-positive rates with no significant loss in true positives and may reduce the number of examinations unnecessarily sent to consensus/arbitration.


Asunto(s)
Neoplasias de la Mama , Detección Precoz del Cáncer , Mamografía , Radiólogos , Humanos , Mamografía/métodos , Mamografía/estadística & datos numéricos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Estudios Retrospectivos , Inglaterra , Noruega , Radiólogos/estadística & datos numéricos , Radiólogos/normas , Detección Precoz del Cáncer/métodos , Detección Precoz del Cáncer/estadística & datos numéricos , Persona de Mediana Edad , Suecia , Modelos Logísticos , Anciano , Variaciones Dependientes del Observador
4.
Med Phys ; 51(10): 7093-7107, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39008812

RESUMEN

BACKGROUND: Lesion detection is one of the most important clinical tasks in positron emission tomography (PET) for oncology. An anthropomorphic model observer (MO) designed to replicate human observers (HOs) in a detection task is an important tool for assessing task-based image quality. The channelized Hotelling observer (CHO) has been the most popular anthropomorphic MO. Recently, deep learning MOs (DLMOs), mostly based on convolutional neural networks (CNNs), have been investigated for various imaging modalities. However, there have been few studies on DLMOs for PET. PURPOSE: The goal of the study is to investigate whether DLMOs can predict HOs better than conventional MOs such as CHO in a two-alternative forced-choice (2AFC) detection task using PET images with real anatomical variability. METHODS: Two types of DLMOs were implemented: (1) CNN DLMO, and (2) CNN-SwinT DLMO that combines CNN and Swin Transformer (SwinT) encoders. Lesion-absent PET images were reconstructed from clinical data, and lesion-present images were reconstructed with adding simulated lesion sinogram data. Lesion-present and lesion-absent PET image pairs were labeled by eight HOs consisting of four radiologists and four image scientists in a 2AFC detection task. In total, 2268 pairs of lesion-present and lesion-absent images were used for training, 324 pairs for validation, and 324 pairs for test. CNN DLMO, CNN-SwinT DLMO, CHO with internal noise, and non-prewhitening matched filter (NPWMF) were compared in the same train-test paradigm. For comparison, six quantitative metrics including prediction accuracy, mean squared errors (MSEs) and correlation coefficients, which measure how well a MO predicts HOs, were calculated in a 9-fold cross-validation experiment. RESULTS: In terms of the accuracy and MSE metrics, CNN DLMO and CNN-SwinT DLMO showed better performance than CHO and NPWMF, and CNN-SwinT DLMO showed the best performance among the MOs evaluated. CONCLUSIONS: DLMO can predict HOs more accurately than conventional MOs such as CHO in PET lesion detection. Combining SwinT and CNN encoders can improve the DLMO prediction performance compared to using CNN only.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Tomografía de Emisión de Positrones , Procesamiento de Imagen Asistido por Computador/métodos , Humanos
5.
J Med Imaging (Bellingham) ; 11(4): 045501, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38988989

RESUMEN

Purpose: Radiologists are tasked with visually scrutinizing large amounts of data produced by 3D volumetric imaging modalities. Small signals can go unnoticed during the 3D search because they are hard to detect in the visual periphery. Recent advances in machine learning and computer vision have led to effective computer-aided detection (CADe) support systems with the potential to mitigate perceptual errors. Approach: Sixteen nonexpert observers searched through digital breast tomosynthesis (DBT) phantoms and single cross-sectional slices of the DBT phantoms. The 3D/2D searches occurred with and without a convolutional neural network (CNN)-based CADe support system. The model provided observers with bounding boxes superimposed on the image stimuli while they looked for a small microcalcification signal and a large mass signal. Eye gaze positions were recorded and correlated with changes in the area under the ROC curve (AUC). Results: The CNN-CADe improved the 3D search for the small microcalcification signal ( Δ AUC = 0.098 , p = 0.0002 ) and the 2D search for the large mass signal ( Δ AUC = 0.076 , p = 0.002 ). The CNN-CADe benefit in 3D for the small signal was markedly greater than in 2D ( Δ Δ AUC = 0.066 , p = 0.035 ). Analysis of individual differences suggests that those who explored the least with eye movements benefited the most from the CNN-CADe ( r = - 0.528 , p = 0.036 ). However, for the large signal, the 2D benefit was not significantly greater than the 3D benefit ( Δ Δ AUC = 0.033 , p = 0.133 ). Conclusion: The CNN-CADe brings unique performance benefits to the 3D (versus 2D) search of small signals by reducing errors caused by the underexploration of the volumetric data.

6.
Policy Insights Behav Brain Sci ; 11(1): 43-50, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38933347

RESUMEN

Sensory systems continuously recalibrate their responses according to the current stimulus environment. As a result, perception is strongly affected by the current and recent context. These adaptative changes affect both sensitivity (e.g., habituating to noise, seeing better in the dark) and appearance (e.g. how things look, what catches attention) and adjust to many perceptual properties (e.g. from light level to the characteristics of someone's face). They therefore have a profound effect on most perceptual experiences, and on how and how well the senses work in different settings. Characterizing the properties of adaptation, how it manifests, and when it influences perception in modern environments can provide insights into the diversity of human experience. Adaptation could also be leveraged both to optimize perceptual abilities (e.g. in visual inspection tasks like radiology) and to mitigate unwanted consequences (e.g. exposure to potentially unhealthy stimulus environments).

7.
IEEE Trans Radiat Plasma Med Sci ; 8(4): 439-450, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38766558

RESUMEN

There is an important need for methods to process myocardial perfusion imaging (MPI) single-photon emission computed tomography (SPECT) images acquired at lower-radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects compared to low-dose images. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose a detection task-specific deep-learning-based approach for denoising MPI SPECT images (DEMIST). The approach, while performing denoising, is designed to preserve features that influence observer performance on detection tasks. We objectively evaluated DEMIST on the task of detecting perfusion defects using a retrospective study with anonymized clinical data in patients who underwent MPI studies across two scanners (N = 338). The evaluation was performed at low-dose levels of 6.25%, 12.5%, and 25% and using an anthropomorphic channelized Hotelling observer. Performance was quantified using area under the receiver operating characteristics curve (AUC). Images denoised with DEMIST yielded significantly higher AUC compared to corresponding low-dose images and images denoised with a commonly used task-agnostic deep learning-based denoising method. Similar results were observed with stratified analysis based on patient sex and defect type. Additionally, DEMIST improved visual fidelity of the low-dose images as quantified using root mean squared error and structural similarity index metric. A mathematical analysis revealed that DEMIST preserved features that assist in detection tasks while improving the noise properties, resulting in improved observer performance. The results provide strong evidence for further clinical evaluation of DEMIST to denoise low-count images in MPI SPECT.

8.
J Med Imaging (Bellingham) ; 11(3): 035501, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38737494

RESUMEN

Purpose: The average (fav) or peak (fpeak) noise power spectrum (NPS) frequency is often used as a one-parameter descriptor of the CT noise texture. Our study develops a more complete two-parameter model of the CT NPS and investigates the sensitivity of human observers to changes in it. Approach: A model of CT NPS was created based on its fpeak and a half-Gaussian fit (σ) to the downslope. Two-alternative forced-choice staircase studies were used to determine perceptual thresholds for noise texture, defined as parameter differences with a predetermined level of discrimination performance (80% correct). Five imaging scientist observers performed the forced-choice studies for eight directions in the fpeak/σ-space, for two reference NPSs (corresponding to body and lung kernels). The experiment was repeated with 32 radiologists, each evaluating a single direction in the fpeak/σ-space. NPS differences were quantified by the noise texture contrast (Ctexture), the integral of the absolute NPS difference. Results: The two-parameter NPS model was found to be a good representation of various clinical CT reconstructions. Perception thresholds for fpeak alone are 0.2 lp/cm for body and 0.4 lp/cm for lung NPSs. For σ, these values are 0.15 and 2 lp/cm, respectively. Thresholds change if the other parameter also changes. Different NPSs with the same fpeak or fav can be discriminated. Nonradiologist observers did not need more Ctexture than radiologists. Conclusions: fpeak or fav is insufficient to describe noise texture completely. The discrimination of noise texture changes depending on its frequency content. Radiologists do not discriminate noise texture changes better than nonradiologists.

9.
Med Phys ; 51(2): 933-945, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38154070

RESUMEN

BACKGROUND: Breast computed tomography (CT) is an emerging breast imaging modality, and ongoing developments aim to improve breast CT's ability to detect microcalcifications. To understand the effects of different parameters on microcalcification detectability, a virtual clinical trial study was conducted using hybrid images and convolutional neural network (CNN)-based model observers. Mathematically generated microcalcifications were embedded into breast CT data sets acquired at our institution, and parameters related to calcification size, calcification contrast, cluster diameter, cluster density, and image display method (i.e., single slices, slice averaging, and maximum-intensity projections) were evaluated for their influence on microcalcification detectability. PURPOSE: To investigate the individual effects and the interplay of parameters affecting microcalcification detectability in breast CT. METHODS: Spherical microcalcifications of varying diameters (0.04, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40 mm) and native intensities were computer simulated to portray the partial volume effects of the imaging system. Calcifications were mathematically embedded into 109 patient breast CT volume data sets as individual calcifications or as clusters of calcifications. Six numbers of calcifications (1, 3, 5, 7, 10, 15) distributed within six cluster diameters (1, 3, 5, 6, 8, 10 mm) were simulated to study the effect of cluster density. To study the role of image display method, 2D regions of interest (ROIs) and 3D volumes of interest (VOIs) were generated using single slice extraction, slice averaging, and maximum-intensity projection (MIP). 2D and 3D CNNs were trained on the ROIs and VOIs, and receiver operating characteristic (ROC) curve analysis was used to evaluate detection performance. The area under the ROC curve (AUC) was used as the primary performance metric. RESULTS: Detection performance decreased with increasing section thickness, and peak detection performance occurred using the native section thickness (0.2 mm) and MIP display. The MIP display method, despite using a single slice, yielded comparable performance to the native section thickness, which employed 50 slices. Reduction in slices did not sacrifice detection accuracy and provided significant computational advantages over multi-slice image volumes. Larger cluster diameters resulted in reduced overall detectability, while smaller cluster diameters led to increased detectability. Additionally, we observed that the presence of more calcifications within a cluster improved the overall detectability, while fewer calcifications decreased it. CONCLUSIONS: As breast CT is still a relatively new breast imaging modality, there is an ongoing need to identify optimal imaging protocols. This work demonstrated the utility of MIP presentation for displaying image volumes containing microcalcification clusters. It is likely that human observers may also benefit from viewing MIPs compared to individual slices. The results of this investigation begin to elucidate how model observers interact with microcalcification clusters in a 3D volume, and will be useful for future studies investigating a broader set of parameters related to breast CT.


Asunto(s)
Enfermedades de la Mama , Calcinosis , Humanos , Mamografía/métodos , Tomografía Computarizada por Rayos X/métodos , Calcinosis/diagnóstico por imagen , Redes Neurales de la Computación
10.
J Med Imaging (Bellingham) ; 10(6): 065502, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38074625

RESUMEN

Purpose: Anatomical "noise" is an important limitation of full-field digital mammography. Understanding its impact on clinical judgments is made difficult by the complexity of breast parenchyma, which results in image texture not fully captured by the power spectrum. While the number of possible parameters for characterizing anatomical noise is quite large, a specific set of local texture statistics has been shown to be visually salient, and human sensitivity to these statistics corresponds to their informativeness in natural scenes. Approach: We evaluate these local texture statistics in addition to standard power-spectral measures to determine whether they have additional explanatory value for radiologists' breast density judgments. We analyzed an image database consisting of 111 disease-free mammographic screening exams (4 views each) acquired at the University of Pittsburgh Medical Center. Each exam had a breast density score assigned by the examining radiologist. Power-spectral descriptors and local image statistics were extracted from images of breast parenchyma. Model-selection criteria and accuracy were used to assess the explanatory and predictive value of local image statistics for breast density judgments. Results: The model selection criteria show that adding local texture statistics to descriptors of the power spectra produce better explanatory and predictive models of radiologists' judgments of breast density. Thus, local texture statistics capture, in some form, non-Gaussian aspects of texture that radiologists are using. Conclusions: Since these local texture statistics are expected to be impacted by imaging factors like modality, dose, and image processing, they suggest avenues for understanding and optimizing observer performance.

11.
Radiology ; 309(1): e222691, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37874241

RESUMEN

Background Despite variation in performance characteristics among radiologists, the pairing of radiologists for the double reading of screening mammograms is performed randomly. It is unknown how to optimize pairing to improve screening performance. Purpose To investigate whether radiologist performance characteristics can be used to determine the optimal set of pairs of radiologists to double read screening mammograms for improved accuracy. Materials and Methods This retrospective study was performed with reading outcomes from breast cancer screening programs in Sweden (2008-2015), England (2012-2014), and Norway (2004-2018). Cancer detection rates (CDRs) and abnormal interpretation rates (AIRs) were calculated, with AIR defined as either reader flagging an examination as abnormal. Individual readers were divided into performance categories based on their high and low CDR and AIR. The performance of individuals determined the classification of pairs. Random pair performance, for which any type of pair was equally represented, was compared with the performance of specific pairing strategies, which consisted of pairs of readers who were either opposite or similar in AIR and/or CDR. Results Based on a minimum number of examinations per reader and per pair, the final study sample consisted of 3 592 414 examinations (Sweden, n = 965 263; England, n = 837 048; Norway, n = 1 790 103). The overall AIRs and CDRs for all specific pairing strategies (Sweden AIR range, 45.5-56.9 per 1000 examinations and CDR range, 3.1-3.6 per 1000; England AIR range, 68.2-70.5 per 1000 and CDR range, 8.9-9.4 per 1000; Norway AIR range, 81.6-88.1 per 1000 and CDR range, 6.1-6.8 per 1000) were not significantly different from the random pairing strategy (Sweden AIR, 54.1 per 1000 examinations and CDR, 3.3 per 1000; England AIR, 69.3 per 1000 and CDR, 9.1 per 1000; Norway AIR, 84.1 per 1000 and CDR, 6.3 per 1000). Conclusion Pairing a set of readers based on different pairing strategies did not show a significant difference in screening performance when compared with random pairing. © RSNA, 2023.


Asunto(s)
Mamografía , Examen Físico , Humanos , Estudios Retrospectivos , Inglaterra , Radiólogos
12.
Med Phys ; 50(11): 6748-6761, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37639329

RESUMEN

BACKGROUND: The use of iodine-based contrast agent for better delineation of tumors in breast CT (bCT) has been shown to be compelling, similar to the tumor enhancement in contrast-enhanced breast MRI. Contrast-enhanced bCT (CE-bCT) is a relatively new tool, and a structured evaluation of different imaging parameters at play has yet to be conducted. In this investigation, data sets of acquired bCT images from 253 patients imaged at our institution were used in concert with simulated mathematically inserted spherical contrast-enhanced lesions to study the role of contrast enhancement on detectability. PURPOSE: To quantitatively evaluate the improvement in lesion detectability due to contrast enhancement across lesion diameter, section thickness, view plane, and breast density using a pre-whitened matched filter (PWMF) model observer. METHODS: The relationship between iodine concentration and Hounsfield units (HU) was measured using spectral modeling. The lesion enhancement from clinical CE-bCT images in 22 patients was evaluated, and the average contrast enhancement (ΔHU) was determined. Mathematically generated spherical mass lesions of varying diameters (1, 3, 5, 9, 11, 15 mm) and contrast enhancement levels (0, 0.25, 0.50, 0.75, 1) were inserted at random locations in 253 actual patient bCT datasets. Images with varying thicknesses (0.4-19.8 mm) were generated by slice averaging, and the role of view plane (coronal and axial planes) was studied. A PWMF was used to generate receiver operating characteristic (ROC) curves across parameters of lesion diameter, contrast enhancement, section thickness, view plane, and breast density. The area under the ROC curve (AUC) was used as the primary performance metric, generated from over 90,000 simulated lesions. RESULTS: An average 20% improvement (ΔAUC = 0.1) in lesion detectability due to contrast enhancement was observed across lesion diameter, section thickness, breast density, and view plane. A larger improvement was observed when stratifying patients based on breast density. For patients with VGF ≤ 40%, detection performance improved up to 20% (until AUC →1), and for patients with denser breasts (VGF > 40%), detection performance improved more drastically, ranging from 20% to 80% for 1- and 5-mm lesions. For the 1 mm lesion, detection performance raised slightly at the 1.2 mm section thickness before falling off as thickness increased. For larger lesions, detection performance was generally unaffected as section thickness increased up until it reached 5.8 mm, where performance began to decline. Detection performance was higher in the axial plane compared to the coronal plane for smaller lesions and thicker sections. CONCLUSIONS: For emerging diagnostic tools like CE-bCT, it is important to optimize imaging protocols for lesion detection. In this study, we found that intravenous contrast can be used to detect small lesions in dense breasts. Optimal section thickness for detectability has dependencies on breast density and lesion size, therefore, display thickness should be adjusted in real-time using display software. These findings may be useful for the development of CE-bCT as well as other x-ray-based breast imaging modalities.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Mama/diagnóstico por imagen , Mama/patología , Imagenología Tridimensional/métodos , Mamografía/métodos , Fantasmas de Imagen
13.
Med Phys ; 50(12): 7558-7567, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37646463

RESUMEN

BACKGROUND: Mathematical model observers have been shown to reasonably predict human observer performance and are useful when human observer studies are infeasible. Recently, convolutional neural networks (CNNs) have also been used as substitutes for human observers, and studies have shown their utility as an optimal observer. In this study, a CNN model observer is compared to the pre-whitened matched filter (PWMF) model observer in detecting simulated mass lesions inserted into 253 acquired breast computed tomography (bCT) images from patients imaged at our institution. PURPOSE: To compare CNN and PWMF model observers for detecting signal-known-exactly (SKE) location-known-exactly (LKE) simulated lesions in bCT images with real anatomical backgrounds, and to use these model observers collectively to optimize parameters and understand trends in performance with breast CT. METHODS: Spherical lesions with different diameters (1, 3, 5, 9 mm) were mathematically inserted into reconstructed patient bCT image data sets to mimic 3D mass lesions in the breast. 2D images were generated by extracting the center slice along the axial dimension or by slice averaging across adjacent slices to model thicker sections (0.4, 1.2, 2.0, 6.0, 12.4, 20.4 mm). The role of breast density was retrospectively studied using the range of breast densities intrinsic to the patient bCT data sets. In addition, mass lesions were mathematically inserted into Gaussian images matched to the mean and noise power spectrum of the bCT images to better understand the performance of the CNN in the context of a known ideal observer (the PWMF). The simulated Gaussian and bCT images were divided into training and testing data sets. Each training data set consisted of 91 600 images, and each testing data set consisted of 96 000 images. A CNN and PWMF was trained on the Gaussian training images, and a different CNN and PWMF was trained on the bCT training images. The trained model observers were tested, and receiver operating characteristic (ROC) curve analysis was used to evaluate detection performance. The area under the ROC curve (AUC) was the primary performance metric used to compare the model observers. RESULTS: In the Gaussian background, the CNN performed essentially identically to the PWMF across lesion sizes and section thicknesses. In the bCT background, the CNN outperformed the PWMF across lesion size, breast density, and most section thicknesses. These findings suggest that there are higher-order features in bCT images that are harnessed by the CNN observer but are inaccessible to the PWMF. CONCLUSIONS: The CNN performed equivalently to the ideal observer in Gaussian textures. In bCT background, the CNN captures more diagnostic information than the PWMF and may be a more pertinent observer when conducting optimal performance studies in breast CT images.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Redes Neurales de la Computación , Mama/diagnóstico por imagen
14.
Artículo en Inglés | MEDLINE | ID: mdl-37274423

RESUMEN

Attenuation compensation (AC) is beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, traditional AC methods require the availability of a transmission scan, most often a CT scan. This approach has the disadvantage of increased radiation dose, increased scanner costs, and the possibility of inaccurate diagnosis in cases of misregistration between the SPECT and CT images. Further, many SPECT systems do not include a CT component. To address these issues, we developed a Scatter-window projection and deep Learning-based AC (SLAC) method to perform AC without a separate transmission scan. To investigate the clinical efficacy of this method, we then objectively evaluated the performance of this method on the clinical task of detecting perfusion defects on MPI in a retrospective study with anonymized clinical SPECT/CT stress MPI images. The proposed method was compared with CT-based AC (CTAC) and no-AC (NAC) methods. Our results showed that the SLAC method yielded an almost overlapping receiver operating characteristic (ROC) plot and a similar area under the ROC (AUC) to the CTAC method on this task. These results demonstrate the capability of the SLAC method for transmission-less AC in SPECT and motivate further clinical evaluation.

15.
ArXiv ; 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37332570

RESUMEN

There is an important need for methods to process myocardial perfusion imaging (MPI) SPECT images acquired at lower radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose a Detection task-specific deep-learning-based approach for denoising MPI SPECT images (DEMIST). The approach, while performing denoising, is designed to preserve features that influence observer performance on detection tasks. We objectively evaluated DEMIST on the task of detecting perfusion defects using a retrospective study with anonymized clinical data in patients who underwent MPI studies across two scanners (N = 338). The evaluation was performed at low-dose levels of 6.25%, 12.5% and 25% and using an anthropomorphic channelized Hotelling observer. Performance was quantified using area under the receiver operating characteristics curve (AUC). Images denoised with DEMIST yielded significantly higher AUC compared to corresponding low-dose images and images denoised with a commonly used task-agnostic DL-based denoising method. Similar results were observed with stratified analysis based on patient sex and defect type. Additionally, DEMIST improved visual fidelity of the low-dose images as quantified using root mean squared error and structural similarity index metric. A mathematical analysis revealed that DEMIST preserved features that assist in detection tasks while improving the noise properties, resulting in improved observer performance. The results provide strong evidence for further clinical evaluation of DEMIST to denoise low-count images in MPI SPECT.

16.
J Med Imaging (Bellingham) ; 10(Suppl 1): S11909, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37114188

RESUMEN

Purpose: Radiologists and other image readers spend prolonged periods inspecting medical images. The visual system can rapidly adapt or adjust sensitivity to the images that an observer is currently viewing, and previous studies have demonstrated that this can lead to pronounced changes in the perception of mammogram images. We compared these adaptation effects for images from different imaging modalities to explore both general and modality-specific consequences of adaptation in medical image perception. Approach: We measured perceptual changes induced by adaptation to images acquired by digital mammography (DM) or digital breast tomosynthesis (DBT), which have both similar and distinct textural properties. Participants (nonradiologists) adapted to images from the same patient acquired from each modality or for different patients with American College of Radiology-Breast Imaging Reporting and Data System (BI-RADS) classification of dense or fatty tissue. The participants then judged the appearance of composite images formed by blending the two adapting images (i.e., DM versus DBT or dense versus fatty in each modality). Results: Adaptation to either modality produced similar significant shifts in the perception of dense and fatty textures, reducing the salience of the adapted component in the test images. In side-by-side judgments, a modality-specific adaptation effect was not observed. However, when the images were directly fixated during adaptation and testing, so that the textural differences between the modalities were more visible, significantly different changes in the sensitivity to the noise in the images were observed. Conclusions: These results confirm that observers can readily adapt to the visual properties or spatial textures of medical images in ways that can bias their perception of the images, and that adaptation can also be selective for the distinctive visual features of images acquired by different modalities.

17.
Med Phys ; 50(7): 4151-4172, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37057360

RESUMEN

BACKGROUND: This study reports the results of a set of discrimination experiments using simulated images that represent the appearance of subtle lesions in low-dose computed tomography (CT) of the lungs. Noise in these images has a characteristic ramp-spectrum before apodization by noise control filters. We consider three specific diagnostic features that determine whether a lesion is considered malignant or benign, two system-resolution levels, and four apodization levels for a total of 24 experimental conditions. PURPOSE: The goal of the investigation is to better understand how well human observers perform subtle discrimination tasks like these, and the mechanisms of that performance. We use a forced-choice psychophysical paradigm to estimate observer efficiency and classification images. These measures quantify how effectively subjects can read the images, and how they use images to perform discrimination tasks across the different imaging conditions. MATERIALS AND METHODS: The simulated CT images used as stimuli in the psychophysical experiments are generated from high-resolution objects passed through a modulation transfer function (MTF) before down-sampling to the image-pixel grid. Acquisition noise is then added with a ramp noise-power spectrum (NPS), with subsequent smoothing through apodization filters. The features considered are lesion size, indistinct lesion boundary, and a nonuniform lesion interior. System resolution is implemented by an MTF with resolution (10% max.) of 0.47 or 0.58 cyc/mm. Apodization is implemented by a Shepp-Logan filter (Sinc profile) with various cutoffs. Six medically naïve subjects participated in the psychophysical studies, entailing training and testing components for each condition. Training consisted of staircase procedures to find the 80% correct threshold for each subject, and testing involved 2000 psychophysical trials at the threshold value for each subject. Human-observer performance is compared to the Ideal Observer to generate estimates of task efficiency. The significance of imaging factors is assessed using ANOVA. Classification images are used to estimate the linear template weights used by subjects to perform these tasks. Classification-image spectra are used to analyze subject weights in the spatial-frequency domain. RESULTS: Overall, average observer efficiency is relatively low in these experiments (10%-40%) relative to detection and localization studies reported previously. We find significant effects for feature type and apodization level on observer efficiency. Somewhat surprisingly, system resolution is not a significant factor. Efficiency effects of the different features appear to be well explained by the profile of the linear templates in the classification images. Increasingly strong apodization is found to both increase the classification-image weights and to increase the mean-frequency of the classification-image spectra. A secondary analysis of "Unapodized" classification images shows that this is largely due to observers undoing (inverting) the effects of apodization filters. CONCLUSIONS: These studies demonstrate that human observers can be relatively inefficient at feature-discrimination tasks in ramp-spectrum noise. Observers appear to be adapting to frequency suppression implemented in apodization filters, but there are residual effects that are not explained by spatial weighting patterns. The studies also suggest that the mechanisms for improving performance through the application of noise-control filters may require further investigation.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Algoritmos
18.
IEEE Trans Med Imaging ; 42(8): 2176-2188, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37027767

RESUMEN

Current medical imaging increasingly relies on 3D volumetric data making it difficult for radiologists to thoroughly search all regions of the volume. In some applications (e.g., Digital Breast Tomosynthesis), the volumetric data is typically paired with a synthesized 2D image (2D-S) generated from the corresponding 3D volume. We investigate how this image pairing affects the search for spatially large and small signals. Observers searched for these signals in 3D volumes, 2D-S images, and while viewing both. We hypothesize that lower spatial acuity in the observers' visual periphery hinders the search for the small signals in the 3D images. However, the inclusion of the 2D-S guides eye movements to suspicious locations, improving the observer's ability to find the signals in 3D. Behavioral results show that the 2D-S, used as an adjunct to the volumetric data, improves the localization and detection of the small (but not large) signal compared to 3D alone. There is a concomitant reduction in search errors as well. To understand this process at a computational level, we implement a Foveated Search Model (FSM) that executes human eye movements and then processes points in the image with varying spatial detail based on their eccentricity from fixations. The FSM predicts human performance for both signals and captures the reduction in search errors when the 2D-S supplements the 3D search. Our experimental and modeling results delineate the utility of 2D-S in 3D search-reduce the detrimental impact of low-resolution peripheral processing by guiding attention to regions of interest, effectively reducing errors.


Asunto(s)
Imagenología Tridimensional , Mamografía , Humanos , Mamografía/métodos , Imagenología Tridimensional/métodos
19.
ArXiv ; 2023 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-36911280

RESUMEN

Attenuation compensation (AC) is beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, traditional AC methods require the availability of a transmission scan, most often a CT scan. This approach has the disadvantages of increased radiation dose, increased scanner cost, and the possibility of inaccurate diagnosis in cases of misregistration between the SPECT and CT images. Further, many SPECT systems do not include a CT component. To address these issues, we developed a Scatter-window projection and deep Learning-based AC (SLAC) method to perform AC without a separate transmission scan. To investigate the clinical efficacy of this method, we then objectively evaluated the performance of this method on the clinical task of detecting perfusion defects on MPI in a retrospective study with anonymized clinical SPECT/CT stress MPI images. The proposed method was compared with CT-based AC (CTAC) and no-AC (NAC) methods. Our results showed that the SLAC method yielded an almost overlapping receiver operating characteristic (ROC) plot and a similar area under the ROC (AUC) to the CTAC method on this task. These results demonstrate the capability of the SLAC method for transmission-less AC in SPECT and motivate further clinical evaluation.

20.
Ultrasound Med Biol ; 49(6): 1465-1475, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36967332

RESUMEN

OBJECTIVE: The aim of this work was to evaluate the reliability of power Doppler ultrasound (PD-US) measurements made without contrast enhancement to monitor temporal changes in peripheral blood perfusion. METHODS: On the basis of pre-clinical rodent studies, we found that combinations of spatial registration and clutter filtering techniques applied to PD-US signals reproducibly tracked blood perfusion in skeletal muscle. Perfusion is monitored while modulating hindlimb blood flow. First, in invasive studies, PD-US measurements in deep muscle with laser speckle contrast imaging (LSCI) of superficial tissues made before, during and after short-term arterial clamping were compared. Then, in non-invasive studies, a pressure cuff was employed to generate longer-duration hindlimb ischemia. Here, B-mode imaging was also applied to measure flow-mediated dilation of the femoral artery while, simultaneously, PD-US was used to monitor downstream muscle perfusion to quantify reactive hyperemia. Measurements in adult male and female mice and rats, some with exercise conditioning, were included to explore biological variables. RESULTS: PD-US methods are validated through comparisons with LSCI measurements. As expected, no significant differences were found between sexes or fitness levels in flow-mediated dilation or reactive hyperemia estimates, although post-ischemic perfusion was enhanced with exercise conditioning, suggesting there could be differences between the hyperemic responses of conduit and resistive vessels. CONCLUSION: Overall, we found non-contrast PD-US imaging can reliably monitor relative spatiotemporal changes in muscle perfusion. This study supports the development of PD-US methods for monitoring perfusion changes in patients at risk for peripheral artery disease.


Asunto(s)
Hiperemia , Masculino , Femenino , Ratas , Ratones , Animales , Roedores , Reproducibilidad de los Resultados , Velocidad del Flujo Sanguíneo , Músculo Esquelético , Isquemia/diagnóstico por imagen , Ultrasonografía Doppler , Arteria Femoral/diagnóstico por imagen , Dilatación Patológica , Perfusión , Flujo Sanguíneo Regional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA