Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38448258

RESUMEN

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.

2.
Postepy Kardiol Interwencyjnej ; 19(1): 6-13, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37090217

RESUMEN

Introduction: Today, endovascular treatment (EVT) is the therapy of choice for strokes due to acute large vessel occlusion, irrespective of prior thrombolysis. This necessitates fast, coordinated multi-specialty collaboration. Currently, in most countries, the number of physicians and centres with expertise in EVT is limited. Thus, only a small proportion of eligible patients receive this potentially life-saving therapy, often after significant delays. Hence, there is an unmet need to train a sufficient number of physicians and centres in acute stroke intervention in order to allow widespread and timely access to EVT. Aim: To provide multi-specialty training guidelines for competency, accreditation and certification of centres and physicians in EVT for acute large vessel occlusion strokes. Material and methods: The World Federation for Interventional Stroke Treatment (WIST) consists of experts in the field of endovascular stroke treatment. This interdisciplinary working group developed competency - rather than time-based - guidelines for operator training, taking into consideration trainees' previous skillsets and experience. Existing training concepts from mostly single specialty organizations were analysed and incorporated. Results: The WIST establishes an individualized approach to acquiring clinical knowledge and procedural skills to meet the competency requirements for certification of interventionalists of various disciplines and stroke centres in EVT. WIST guidelines encourage acquisition of skills using innovative training methods such as structured supervised high-fidelity simulation and procedural performance on human perfused cadaveric models. Conclusions: WIST multispecialty guidelines outline competency and quality standards for physicians and centres to perform safe and effective EVT. The role of quality control and quality assurance is highlighted.

3.
Cardiovasc Revasc Med ; 53: 67-72, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37012107

RESUMEN

INTRODUCTION: Today, endovascular treatment (EVT) is the therapy of choice for strokes due to acute large vessel occlusion, irrespective of prior thrombolysis. This necessitates fast, coordinated multi-specialty collaboration. Currently, in most countries, the number of physicians and centres with expertise in EVT is limited. Thus, only a small proportion of eligible patients receive this potentially life-saving therapy, often after significant delays. Hence, there is an unmet need to train a sufficient number of physicians and centres in acute stroke intervention in order to allow widespread and timely access to EVT. AIM: To provide multi-specialty training guidelines for competency, accreditation and certification of centres and physicians in EVT for acute large vessel occlusion strokes. MATERIAL AND METHODS: The World Federation for Interventional Stroke Treatment (WIST) consists of experts in the field of endovascular stroke treatment. This interdisciplinary working group developed competency - rather than time-based - guidelines for operator training, taking into consideration trainees' previous skillsets and experience. Existing training concepts from mostly single specialty organizations were analysed and incorporated. RESULTS: The WIST establishes an individualized approach to acquiring clinical knowledge and procedural skills to meet the competency requirements for certification of interventionalists of various disciplines and stroke centres in EVT. WIST guidelines encourage acquisition of skills using innovative training methods such as structured supervised high-fidelity simulation and procedural performance on human perfused cadaveric models. CONCLUSIONS: WIST multispecialty guidelines outline competency and quality standards for physicians and centres to perform safe and effective EVT. The role of quality control and quality assurance is highlighted. SUMMARY: The World Federation for Interventional Stroke Treatment (WIST) establishes an individualized approach to acquiring clinical knowledge and procedural skills to meet the competency requirements for certification of interventionalists of various disciplines and stroke centres in endovascular treatment (EVT). WIST guidelines encourage acquisition of skills using innovative training methods such as structured supervised high-fidelity simulation and procedural performance on human perfused cadaveric models. WIST multispecialty guidelines outline competency and quality standards for physicians and centers to perform safe and effective EVT. The role of quality control and quality assurance is highlighted. SIMULTANEOUS PUBLICATION: The WIST 2023 Guidelines are published simultaneously in Europe (Adv Interv Cardiol 2023).


Asunto(s)
Procedimientos Endovasculares , Accidente Cerebrovascular , Humanos , Trombectomía/métodos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/terapia , Terapia Trombolítica/métodos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Cadáver
4.
Eur Heart J ; 42(4): 298-307, 2021 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-33521827

RESUMEN

This ESC Council on Stroke/EAPCI/EBNI position paper summarizes recommendations for training of cardiologists in endovascular treatment of acute ischaemic stroke. Interventional cardiologists adequately trained to perform endovascular stroke interventions could complement stroke teams to provide the 24/7 on call duty and thus to increase timely access of stroke patients to endovascular treatment. The training requirements for interventional cardiologists to perform endovascular therapy are described in details and should be based on two main principles: (i) patient safety cannot be compromised, (ii) proper training of interventional cardiologists should be under supervision of and guaranteed by a qualified neurointerventionist and within the setting of a stroke team. Interdisciplinary cooperation based on common standards and professional consensus is the key to the quality improvement in stroke treatment.


Asunto(s)
Isquemia Encefálica , Procedimientos Endovasculares , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Isquemia Encefálica/terapia , Humanos , Accidente Cerebrovascular/terapia , Trombectomía , Resultado del Tratamiento
5.
Cardiovasc J Afr ; 32(1): 33-36, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33179714

RESUMEN

This is a review of 114 patients with atrial fibrillation who had left atrial appendage occlusion with an Amplatzer cardiac plug over a nine-year period done by a single operator. This shows that the procedure can be safely performed with a very low rate of major complications (< 1%) and a zero procedural mortality rate. Long-term follow up over an average of 38.5 months showed a 65% reduction in actual versus predicted stroke rate. This is similar to that seen with oral anti-coagulants and other published trials and registries involving left atrial appendage occlusion.


Asunto(s)
Apéndice Atrial/cirugía , Cateterismo Cardíaco/instrumentación , Intervención Coronaria Percutánea/instrumentación , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial , Cateterismo Cardíaco/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento
6.
BMC Ophthalmol ; 20(1): 424, 2020 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-33092549

RESUMEN

BACKGROUND: To prevent irreversible vision loss in age-related macular degeneration (AMD), it is critical to detect retinal dysfunction before permanent structural loss occurs. In the current study we evaluated a series of visual function tests to identify potential endpoints to detect visual dysfunction in non-advanced AMD. METHODS: A series of visual function tests were performed on 23 non-advanced AMD subjects (AREDS grade 1-4 on simplified scale) and 34 age-matched normals (AREDS grade 0). Tests included some commonly used endpoints such as ETDRS visual acuity (VA), low luminance (LL) 2.0ND ETDRS VA, MNREAD as well as newly developed tests such as the Ora-VCF™ test, Ora-tablet reading test, color sensitivity etc. Differences between the two groups were compared for each test. Test-retest repeatability and reproducibility was assessed on a subset of subjects and percent agreement was calculated. RESULTS: There was no difference in standard ETDRS VA between non-advanced AMD (0.06 ± 0.02 logMAR) and normal groups (0.04 ± 0.02 logMAR) (p = 0.57). LL 2.0 ETDRS VA and MNREAD showed no difference between the groups (p > 0.05). Ora-VCF™ test was significantly worse in the non-advanced AMD group compared to normals (0.67 ± 0.07 in AMD; 0.45 ± 0.04 in normals, p = 0.005). Non-advanced AMD subjects also had significantly worse reading performance using the Ora-tablet with LL 2.0ND (114.55 ± 11.22 wpm in AMD; 145.17 ± 9.55 wpm in normals p = 0.049). No significant difference between the groups was noted using other tests. Repeatability was 82% for Ora-VCF™ test and 92% for Ora-tablet LL 2.0ND reading. Reproducibility was 89% for both Ora-VCF™ test and Ora-tablet LL 2.0ND reading. CONCLUSION: While there was no significant difference between non-advanced AMD and normal groups using some current common endpoints such as ETDRS VA, LL 2.0 ETDRS VA or MNREAD, Ora-VCF™ test and Ora-tablet LL 2.0ND reading tests were able to identify significant visual dysfunction in non-advanced AMD subjects. These tests show promise as endpoints for AMD studies.


Asunto(s)
Degeneración Macular , Pruebas de Visión , Humanos , Degeneración Macular/diagnóstico , Reproducibilidad de los Resultados , Trastornos de la Visión/diagnóstico , Agudeza Visual
7.
Clin Ophthalmol ; 14: 2571-2576, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32943838

RESUMEN

PURPOSE: Early detection and treatment of age-related macular degeneration require a clear understanding of the early progress of the disease. The purpose of this study was to investigate whether minimal macular ophthalmoscopic changes corresponded to changes in visual function. METHODS: Color macular photos from a group of older subjects who were classified as grade 0 on AREDS simplified grading were further evaluated by a retinal specialist using 5x magnification for possible minimal macular anomalies. Group 0-A (N = 15) were defined as subjects with no visible macular anomalies while Group 0-B (N = 19) comprised subjects for whom minimal macular mottling, pigment changes or very small drusen (< 63 µm) were observed in the study eye. All subjects had best VA of 20/25 or better and had no evidence of other retinal diseases in the study eye. All subjects underwent a series of visual function tests such as standard ETDRS VA, low luminance ETDRS VA, Pelli-Robson contrast sensitivity, variable contrast flicker (VCF) sensitivity, and reading speed (words per minute, wpm) using both MNRead and low luminance reading on a tablet. RESULTS: There was no significant difference between the mean age between the two groups (74.8 ± 5.2 years for 0-A vs 74.5 ± 4.4 for 0-B, p = 0.82). None of the visual function tests identified any significant difference between the two groups. Mean ETDRS VA was 0.0 ± 0.11 for 0-A subjects and 0.08 ± 0.12 for 0-B (p = 0.063). Mean Pelli-Robson log contrast sensitivity was 1.75 ± 0.29 for 0-A and 1.78 ± 0.17 for the 0-B group (p = 0.73). VCF threshold was 0.47 ± 0.25 for 0-A and 0.43 ± 0.22 for 0-B (p = 0.64). Reading speed using MNRead was 214 ± 47.4 wpm for 0-A and 210 ± 64.7 for 0-B (p = 0.85). Low luminance tablet reading speed was 137 ± 71.8 wpm for 0-A and 151 ± 39.4 (0-B) (p = 0.49). CONCLUSION: A panel of psychophysical tests did not demonstrate significant differences between subjects with and without minimal macular changes.

8.
J Ophthalmol ; 2019: 2036192, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31781372

RESUMEN

PURPOSE: Impaired adaptation to changes in lighting levels as well as mesopic visual function is a common complaint in those over the age of 65. The use of photostress is a well-established method to test the adaption rate and the response of the visual cycle. In this study, we test visual function recovery to mesopic luminance stimuli following a long duration photostress in young and elderly subjects. If successful in strongly differentiating aging macular function, these methods may also be useful in the study of pathologies such as age-related macular degeneration. METHODS: A group of 12 older normal subjects (mean age 75.1 ± 4.79) and a control group of 5 younger normal subjects (mean age 26.2 ± 4.19) were subjected to macular photostress using the OraLux photostress system. The OraLux system provides a diffuse light source bleaching 84% of cone photopigment while maintaining an exposure safety factor of 200 times less than the maximum safe exposure. After each photostressing session, macular recovery was tracked using a foveal, variable contrast, flickering stimulus of mean luminance in the high mesopic range. Recovery was tracked for 300 seconds. The endpoint was time to recovery to each individual's baseline sensitivity as determined by two static sensitivity trials prior to photostress. RESULTS: Proportional hazards analysis of recovery time yielded a statistically significant difference between the older group and the young group (HR = 0.181; p=0.0289). The estimated hazard ratio of 0.181 indicates that older subjects return to baseline at less than one-fifth the rate of younger subjects. The hazards ratio remained statistically significant after adjusting for visual acuity (HR = 0.093; p=0.0424). CONCLUSION: Photostress recovery of flicker sensitivity under mesopic conditions is a strong differentiator of aging macular function. This agrees with subject-reported complaints in reduced luminance conditions after exposure to bright lights such as night driving. The qualitative similarity between the aging retina and changes in early AMD suggests that flicker recovery following photostress may be useful as a surrogate endpoint in AMD clinical trials.

9.
J Asthma Allergy ; 12: 71-81, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30881050

RESUMEN

PURPOSE: Allergic rhinitis (AR) affects ~20% of the population worldwide. The objectives of this study were to evaluate the safety and efficacy of iodixanol nasal solution (Nasapaque) for AR treatment, using the Allergen BioCube® (ABC®), an environmental exposure unit. Iodixanol is a commonly used contrast media agent that shows efficacy on the signs and symptoms of AR. PATIENTS AND METHODS: Seventy-three adult subjects with AR were randomized to iodixanol or placebo treatment in a double-masked efficacy and safety study conducted outside of ragweed pollen season. In-office treatment was administered after BioCube® ragweed pollen exposure, and again 8 days later prior to ragweed exposure. Nasal and ocular efficacy and safety assessments were conducted before and after treatment. RESULTS: Iodixanol treatment resulted in statistically significantly lower total nasal symptom scores as compared to placebo at several time points post-treatment and ABC exposure. Individual nasal and ocular symptoms, notably nasal itching and ocular itching, showed evidence of lower scores in the iodixanol group. Peak nasal inspiratory flow (PNIF) improved (9%-16%) with iodixanol from baseline as compared to PNIF in the placebo group which ranged from 3% worsening to improvement of 2%. Few (9) adverse events occurred. CONCLUSION: Iodixanol nasal solution demonstrated efficacy for relief of several nasal and ocular allergic rhinoconjunctivitis signs and symptoms, and was safe and well tolerated in this early Phase II exploratory trial. Further studies with iodixanol are warranted. Allergy challenge models such as the ABC provide valuable assessments of allergen exposures and drug efficacies. STUDY IDENTIFICATION NUMBER: NCT02377895.

10.
Clin Ophthalmol ; 12: 1325-1335, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30100705

RESUMEN

PURPOSE: To identify parameters from cone function and recovery after photostress that detect functional deficits in early non-exudative age-related macular degeneration (AMD) and to determine the repeatability of these parameters. METHODS: Cone-mediated visual function recovery after photostress was examined in three groups of subjects: young normal subjects (ages 20-29; N=8), older normal subjects (ages 50-90; N=9), and early non-exudative AMD subjects (ages 50-90; N=12). Eight AMD and four normal subjects were retested 1 year after the initial evaluation. Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity (VA) and parameters of cone function (baseline cone sensitivity and cone recovery half-life following photobleach) were measured and compared between AMD and normal subjects. Short-term repeatability was assessed for each subject's initial evaluation. Long-term repeatability was assessed by comparing outcomes from the initial evaluation and 1-year follow-up. RESULTS: The mean baseline cone threshold was significantly worse in subjects with early AMD compared to older normal subjects (-1.80±0.04 vs -1.57±0.06 log cd/m2p=0.0027). Moreover, the baseline cone threshold parameter exhibited good short-term (intraclass correlation coefficient [ICC]=0.88) and long-term (ICC=0.85) repeatability in all subjects. The cone intercept parameter and ETDRS VA were not significantly different between AMD and older normal subject groups. Cone recovery half-life was significantly different between older normal and AMD subject groups (p=0.041). Neither ETDRS VA nor cone function parameters were significantly different for any group at the 1-year follow-up. CONCLUSION: The baseline cone threshold shows potential as a novel parameter to assess visual dysfunction in early AMD. This outcome consistently detected deficits in AMD subjects, and differentiated them from age-matched controls with high test-retest repeatability.

11.
Homeopatia Méx ; 87(713): 39-44, abr. - jun. 2018. tab
Artículo en Español | LILACS, HomeoIndex | ID: biblio-995363

RESUMEN

El presente artículo muestra los resultados de un estudio que evaluó la efectividad de un medicamento oftálmico homeopático (Eye Drops #2®) en pacientes con conjuntivitis alérgica. 33 personas con antecedentes de respuesta positiva a la aplicación vía tópica ocular de alergeno se evaluaron a través de un modelo aleatorizado, doble ciego y controlado con placebo. Los participantes recibieron un alergeno solubilizado en dos visitas distintas, a fin de evaluar factores como la hiperemia conjuntival, epiescleral y ciliar, así como la quemosis, la hinchazón del párpado, el lagrimeo y la picazón. Luego de esto se les asignaron aleatoriamente dos frascos enmascarados con la indicación de que el contenido de uno se aplicaría en el glóbulo ocular derecho y el otro en el izquierdo (uno contenía el medicamento y el otro placebo). En una tercera visita, posterior al tratamiento, se evaluaron la comodidad y la seguridad del tratamiento, además de que se aplicó una dosis final de alergeno. Los resultados finales mostraron una reducción estadísticamente significativa de los síntomas y los signos de la conjuntivitis alérgica inducida durante la visita 3, por lo que el producto parece ser cómodo y seguro de usar. (AU)


This article presents the results of a study that evaluated the effectiveness of a homeopathic ophthalmic medication (Eye Drops #2®) in patients with allergic conjunctivitis. 33 subjects with a history of positive response to topical ocular allergen challenge were evaluated in a randomised, double-masked, placebo-controlled study. The subjects received a solubilized allergen in two different visits, to evaluate factors such as conjunctival, episcleral, and ciliary hyperemia, chemosis, eyelid swelling, tearing, and itching. After this, the subjects were randomly assigned to two masked bottles labeled right and left, one containing the active drug and the other containing a placebo. On a third visit, after the treatment, comfort and safety were assessed, and a final dose of allergen was applied. The final results showed a statistically significant reduction in the signs and symptoms of allergic conjunctivitis induced during visit 3, so the product seems to be comfortable and safe to use. (AU)


Asunto(s)
Soluciones Oftálmicas/uso terapéutico , Conjuntivitis , Homeopatía , Hipersensibilidad
12.
Curr Eye Res ; 43(1): 52-66, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29043838

RESUMEN

Blink is a complex phenomenon that is profoundly affected by diverse endogenous and exogenous stimuli. It has been studied in the context of cognition, emotional, and psychological states, as an indicator of fatigue and sleepiness, particularly in the automobile and transportation industry, in visual tasking, and finally, as it relates to tear film stability and ocular surface health. The fact that it is highly variable and has input from so many sources makes it very difficult to study. In the present review, the behavior of blink in many of these systems is discussed, ultimately returning in each instance to a discussion of how these factors affect blink in the context of dry eyes. Blink is important to ocular surface health and to an individual's optimal functioning and quality of life. Disturbances in blink, as cause or effect, result in a breakdown of tear film stability, optical clarity, and visual function.


Asunto(s)
Parpadeo/fisiología , Córnea/metabolismo , Síndromes de Ojo Seco/fisiopatología , Calidad de Vida , Lágrimas/química , Síndromes de Ojo Seco/metabolismo , Humanos
13.
Ophthalmol Ther ; 6(2): 263-276, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28956287

RESUMEN

The many internal and external factors that contribute to the pathophysiology of dry eye disease (DED) create a difficult milieu for its study and complicate its clinical diagnosis and treatment. The controlled adverse environment (CAE®) model has been developed to minimize the variability that arises from exogenous factors and to exacerbate the signs and symptoms of DED by stressing the ocular surface in a safe, standardized, controlled, and reproducible manner. By integrating sensitive, specific, and clinically relevant endpoints, the CAE has proven to be a unique and adaptable model for both identifying study-specific patient populations with modifiable signs and symptoms, and for tailoring the evaluation of interventions in clinical research studies.

14.
J Ocul Pharmacol Ther ; 33(9): 686-692, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28933582

RESUMEN

PURPOSE: To assess the sensitivity of corneal cold receptors to a known transient receptor potential melastatin 8 (TRPM8) agonist, menthol, in dry eye and normals, and to determine whether factors such as disease duration or age affect responses. METHODS: Dry eye disease (DED) (N = 33) and normal (N = 15) subjects were randomly assigned to receive Rohto® Hydra (0.01% menthol) or Systane® Ultra treatments (OU) in a prospective, double-blind, crossover study. DED subjects had documented disease and symptom response scores >2 on a 0- to 5-point scale. Normals had no history of DED and scores <2 on the same scale. Endpoints included mean cooling score (0 = not cool and 10 = very cool) evaluated at 0, 0.5, 1, 2, 3, and 4 min post-instillation, sum cooling scores (5 time points, range 0-60), and ocular signs and symptoms. RESULTS: Mean (±SD) ages were similar, 62.2 ± 8.6-year (DED) versus 53.5 ± 7.6-year (normal). Corneal sensitivity scores were not different between groups. Mean cooling scores at 0.5-4 min post-menthol instillation were significantly higher in DED subjects (P ≤ 0.03). Sum cooling scores were significantly higher (P = 0.04) in DED subjects with a disease duration <10 years (N = 18, 28.3 ± 2.58) versus ≥10 years (N = 15, 20.2 ± 2.76). Age did not affect cooling response in either group. CONCLUSION: DED subjects had greater sensitivity to cold than normal subjects. DED duration, and not age, was critical to cooling sensitivity. The finding that cooling scores were higher in subjects with DED for less than 10 years compared to more than 10 years suggests that corneal cold receptor sensitivity decreases as the duration of DED increases.


Asunto(s)
Antipruriginosos/administración & dosificación , Córnea/efectos de los fármacos , Síndromes de Ojo Seco/metabolismo , Mentol/administración & dosificación , Canales Catiónicos TRPM/agonistas , Administración Oftálmica , Adulto , Anciano , Córnea/metabolismo , Estudios Cruzados , Método Doble Ciego , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Canales Catiónicos TRPM/metabolismo , Termorreceptores/fisiología
15.
Immun Inflamm Dis ; 5(1): 78-84, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28250927

RESUMEN

INTRODUCTION: Field studies for allergic rhinitis (AR) commonly have inconsistent allergen concentrations and subject exposure patterns due to varying environmental conditions and subject behaviors. A technical and clinical validation study was conducted for the Allergen BioCube® using timothy grass to confirm uniform allergen concentration and clinically relevant subject symptom responses. METHODS: Allergen concentrations were verified by laser particle counts. Subjects (N = 14) with positive skin test reactions and no symptoms at screening received four 3-h timothy grass exposures in the BioCube over consecutive days. Subjects evaluated nasal itching, sneezing, rhinorrhea, and nasal congestion while in the BioCube; Total Nasal Symptom Score (TNSS) was computed. Peak Nasal Inspiratory Flow (PNIF), Peak Expiratory Flow Rate (PEFR), sIgE blood tests, and Nasal Inflammation Score (NIS) were assessed. A correlation analysis was conducted for mean sIgE, skin test, and TNSS. RESULTS: Uniform timothy grass concentrations were achieved in the BioCube, both spatially and temporally, at all subject positions. Mean TNSS increased substantially from pre-exposure levels (0.36 ± 0.74 to 1.86 ± 2.14) to maximums of 7.07 ± 2.76 at 1.5 h and 6.71 ± 2.70 at 3 h BioCube exposure. Twelve (86%) subjects had TNSS increases ≥6 units. PNIF decreased 12-24% from baseline at 3-h BioCube exposure. NIS increased (baseline = 0) to 3.7 (maximum score = 4). A low/moderate correlation (r = 0.485) occurred between mean sIgE blood levels and mean skin tests; neither sIgE or skin tests correlated with mean TNSS. However, subjects with high skin test scores or positive blood IgE tended to also have higher TNSS. CONCLUSIONS: The Allergen BioCube achieved technical and clinical validation for uniform timothy grass concentration and clinically meaningful AR sign and symptom responses. The Allergen BioCube can be used to assess the efficacy of therapies for reduction of AR signs and symptoms resulting from grass exposure.


Asunto(s)
Alérgenos/inmunología , Cámaras de Exposición Atmosférica , Phleum/inmunología , Rinitis Alérgica Estacional/diagnóstico , Adolescente , Adulto , Anciano , Humanos , Inmunoglobulina E/sangre , Persona de Mediana Edad , Nariz/patología , Nariz/fisiología , Ápice del Flujo Espiratorio , Rinitis Alérgica Estacional/sangre , Rinitis Alérgica Estacional/fisiopatología , Pruebas Cutáneas , Adulto Joven
16.
J Ocul Pharmacol Ther ; 33(2): 79-90, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28072552

RESUMEN

PURPOSE: To evaluate the efficacy and safety of a sustained-release dexamethasone intracanalicular insert (Dextenza™) in a model of allergic conjunctivitis. METHODS: This was a randomized, double-masked, vehicle-controlled, Phase 2 study. Subjects had to have a positive conjunctival allergen challenge (CAC) reaction to allergen (bilateral +2 itching and redness on 5-point, 0-4 scales) at Visit 1, and for 2 of 3 time points on subsequent visits. Subjects who met entry criteria were randomized to receive Dextenza or PV (vehicle insert). Challenges occurred over 42 days, with efficacy assessed at 14 (primary endpoint visit), 28, and 40 days postinsertion. Outcome measures included the evaluation of ocular itching, redness, tearing, chemosis, eyelid swelling, rhinorrhea, and congestion. RESULTS: Twenty-eight subjects completed the study in the Dextenza group and 31 in the vehicle group. At 14 days postinsertion, Dextenza was statistically superior to PV, with least square mean differences for ocular itching of -0.76, -0.97, and -0.87 at 3, 5, and 7 min post-CAC, and for conjunctival redness of -0.46, -0.66, and -0.68 at 7, 15, and 20 min post-CAC. Clinical significance, defined as a 1-U decrease from PV, was not met for primary efficacy. Secondary endpoints, including number of subjects reporting itching and conjunctival redness, indicated superior performance of Dextenza compared with vehicle. Eleven Dextenza-treated (35.5%) and 10 vehicle-treated (30.3%) subjects each experienced a single adverse event. CONCLUSION: This Phase 2 study demonstrated preliminary efficacy and safety data of Dextenza for treatment of allergic conjunctivitis.


Asunto(s)
Antialérgicos/administración & dosificación , Antialérgicos/uso terapéutico , Conjuntivitis Alérgica/tratamiento farmacológico , Dexametasona/administración & dosificación , Dexametasona/uso terapéutico , Administración Oftálmica , Adulto , Anciano , Antialérgicos/efectos adversos , Enfermedad Crónica , Dexametasona/efectos adversos , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
17.
J Allergy Clin Immunol ; 139(4): 1158-1166, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27697498

RESUMEN

BACKGROUND: Field clinical trials of pollen allergy are affected by the impossibility of predicting and determining individual allergen exposure because of many factors (eg, pollen season, atmospheric variations, pollutants, and lifestyles). Environmental exposure chambers, delivering a fixed amount of allergen in a controlled environmental setting, can overcome these limitations. Environmental exposure chambers are currently already used in phase 2, 3, and even 4 trials. Unfortunately, few chambers exist in the world, and this makes it difficult to perform large, multicenter clinical trials. The new Global Allergy and Asthma European Network (GA2LEN) mobile exposure chamber is a step forward because the mobility of the chamber makes it convenient for patients to participate in clinical testing. OBJECTIVE: This study was made to validate the reproducibility, sensitivity, and specificity of the results obtained in the new GA2LEN chamber. METHODS: Seventy-two adult patients (19-61 years old) with allergic rhinitis with or without asthma caused by grass pollen were included in different clinical validation tests. Total symptom scores and total nasal symptom scores were recorded at time zero (0) and every 10 minutes during exposures, along with nasal and respiratory parameters. RESULTS: Exposure tests confirmed the reproducibility between subsequent runs and the sensitivity (P < .00001 vs patients exposed to placebo) and specificity (very low score in nonallergic subjects) in the GA2LEN chamber. No adverse reactions were recorded during the tests. CONCLUSIONS: The mobility of the GA2LEN chamber provides a new, potentially effective, and safe way of generating reliable data in allergy multicenter clinical trials.


Asunto(s)
Alérgenos/administración & dosificación , Técnicas Inmunológicas/instrumentación , Poaceae/inmunología , Rinitis Alérgica Estacional/diagnóstico , Adulto , Alérgenos/efectos adversos , Alérgenos/inmunología , Área Bajo la Curva , Femenino , Humanos , Masculino , Persona de Mediana Edad , Poaceae/efectos adversos , Polen/efectos adversos , Curva ROC , Rinitis Alérgica Estacional/inmunología , Sensibilidad y Especificidad , Adulto Joven
18.
J Asthma Allergy ; 9: 215-221, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28008277

RESUMEN

BACKGROUND: Allergic rhinitis is a common condition, with ragweed pollen one of the more prevalent aeroallergens. Environmental exposure units such as the Allergen BioCube® are valuable models for clinical allergy studies. A study was conducted to validate the Allergen BioCube for uniform ragweed pollen concentrations and clinically relevant sign and symptom responses to ragweed exposure. METHODS: Ragweed pollen concentrations were measured on 3 consecutive days in the Allergen BioCube and verified by Rotorod collection and continuous laser particle count measurements. Subjects (N=10) were exposed to ragweed pollen in the BioCube for 3 hours per day for 3 consecutive days. Subjects assessed their nasal itching, sneezing, rhinorrhea, and nasal congestion during each BioCube exposure; total nasal symptom score was computed. Peak nasal inspiratory flow was also assessed during BioCube exposure. RESULTS: Uniform ragweed pollen concentrations were obtained throughout each of the 3-hour testing periods in the Allergen BioCube, both spatially and temporally, at all subject positions, with a low mean standard deviation of 10%. Pronounced increases in mean total nasal symptom scores (6.7±0.94 to 7.6±0.86, last 90 minutes of exposure) occurred for all three BioCube ragweed pollen exposure visits. Mean peak nasal inspiratory flow decreased 24% at 3 hours of BioCube exposure on Day 3. No safety issues of concern occurred in this study. CONCLUSION: The Allergen BioCube achieved technical and clinical validation for ragweed allergen. Ragweed pollen concentration was uniform both temporally and spatially. Allergic rhinitis signs and symptoms were induced in subjects during exposure to ragweed in the BioCube at clinically meaningful levels for allergy studies.

19.
Cornea ; 35(8): 1104-11, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27261939

RESUMEN

PURPOSE: To assess diurnal changes in the signs and symptoms of dry eyes and their relationship to diurnal interblink interval (IBI) in normal subjects and in subjects with dry eye. METHODS: Blink data were collected from 9:00 AM to 8:00 PM during 2 days of normal activity using an electrocardiogram monitoring device. All subjects recorded ocular discomfort (0-5 scale) and primary activity hourly each day in a diary. Inferior and central fluorescein staining was graded by slit lamp (0-4) at the start and end of each day. Blink activity was detected using an algorithm based on recognition of the waveform corresponding to the kinematic properties of the blink signal. RESULTS: Normal subjects (N = 12) reported negligible symptoms, and results did not show a diurnal change in group hourly IBI. Mean daily IBI for the group with dry eye (N = 15) (4.63 ± 1.63 s) was shorter than that for the normal group (5.28 ± 1.48 s) (P = 0.0483). Correlation of diurnal symptoms and mean hourly IBI was relatively weak (r = -0.248). A repeated-measures model found IBI to be significantly associated with the time of day (P = 0.0028). Inferior corneal staining showed a small but significant diurnal increase for both normal group and group with dry eyes. CONCLUSIONS: Diurnal blink tracking reveals significant trending with symptoms. Diurnal change in IBI may be an appropriate surrogate for symptoms in the study of dry eye.


Asunto(s)
Parpadeo/fisiología , Ritmo Circadiano/fisiología , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/fisiopatología , Algoritmos , Electromiografía , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Fenómenos Fisiológicos Oculares
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA