RESUMEN
Over the last few years, diffusion-weighted imaging (DWI) has become increasingly relevant in the diagnostic assessment of peritoneal carcinomatosis. The aim of this study was to investigate the benefits of high-b DWI (c-DWI) compared to standard DWI in patients with peritoneal carcinomatosis. A cohort of 40 patients with peritoneal carcinomatosis were included in this retrospective study. DWI was performed with b-values of 50, 400, and 800 or 1000 s/mm² on a 1.5-T magnetic resonance imaging (MRI) scanner. C-DWI was calculated using a mono-exponential model with high b-values of 1000, 2000, 3000, 4000, and 5000 s/mm². All c-DWI images with high b-values were compared in terms of volume, detectability of peritoneal lesions, and image quality with the DWI sequence acquired with a b-value of 800 or 1000 s/mm² by two readers. In the group with a b-value of 800 s/mm², there was no statistically significant difference in terms of lesion volume. In the second group with a b-value of 1000 s/mm², peritoneal carcinomatosis lesions were statistically significantly larger than in the c-DWI with a- high b-value of 2000 s/mm² (median 7 cm³, range 1−26 cm³vs. median 6 cm³, range 1−83 cm³, p < 0.05). In both groups, there was a marked decrease in the detectability of peritoneal lesions starting at b = 2000 s/mm². In addition, image quality decreased noticeably from c-DWI at b = 3000 s/mm². In both groups, all images with high b-values at b = 4000 s/mm² and 5000 s/mm² were not diagnostically valuable due to poor image quality. The c-DWI technique offers good diagnostic performance without additional scanning time. High c-DWI b-values up to b = 1000 s/mm² provide comparable detectability of peritoneal carcinomatosis compared to standard DWI. Higher b-values over 1500 s/mm² result in lower image quality, which might lead to misdiagnosis.
Asunto(s)
Neoplasias Peritoneales , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Imagen por Resonancia Magnética/métodos , Neoplasias Peritoneales/diagnóstico por imagen , Estudios RetrospectivosRESUMEN
BACKGROUND AND PURPOSE: Diffusion-weighted imaging (DWI) is a cornerstone in diagnostic of ischemic stroke. The aim of this study was to investigate the usefulness of high-b-value computed DWI (c-DWI) in comparison to standard DWI in patients with acute brainstem infarction. MATERIALS AND METHODS: 56 patients with acute brainstem infarction were retrospectively analysed by two readers. DWI was obtained with the b-values 0, 500 and 1000â¯s/mm² on either a 1.5 or 3â¯T magnetic resonance imaging (MRI) scanner. c-DWI was calculated with a monoexponential model with high b-values 2000, 3000, 4000 and 5000â¯s/mm². All c-DWI series with high-b-values were compared to the standard DWI sequence at b-value of 1000â¯s/mm² in terms of image artifacts, lesion extent and contrast. RESULTS: There was no statistically significant difference between 1.5 and 3â¯T MRI regarding the measured ischemic lesion size. There were no statistically significant differences between the ischemic lesion sizes on DWI at b-values of 1000â¯s/mm² and on c-DWI at higher b-values. Overall, the contrast between the lesion and the surrounding normal areas improved with increasing b-value on the isotropic DWIs: maximum at bâ¯=â¯5000, followed by that at b 2000 and b 1000â¯s/mm², in order. The best relation between artifacts and lesion contrast was identified for b 2000â¯s/mm². CONCLUSION: High b-value DWI derived from c-DWI has a higher visibility for ischemic brainstem lesions compared to standard DWI without additional time cost. The b-2000 image is recommended to use in clinical routine, higher b-value images lead to more imaging artifacts, which might result in misdiagnosis.
Asunto(s)
Infartos del Tronco Encefálico , Imagen de Difusión por Resonancia Magnética , Artefactos , Humanos , Imagen por Resonancia Magnética , Estudios RetrospectivosRESUMEN
Diffusion-weighted imaging (DWI) has rapidly become an essential tool for the detection of malignant liver lesions. The aim of this study was to investigate the usefulness of high b-value computed DWI (c-DWI) in comparison to standard DWI in patients with hepatic metastases. In total, 92 patients with histopathologic confirmed primary tumors with hepatic metastasis were retrospectively analyzed by two readers. DWI was obtained with b-values of 50, 400 and 800 or 1000 s/mm2 on a 1.5 T magnetic resonance imaging (MRI) scanner. C-DWI was calculated with a monoexponential model with high b-values of 1000, 2000, 3000, 4000 and 5000 s/mm2. All c-DWI images with high b-values were compared to the acquired DWI sequence at a b-value of 800 or 1000 s/mm2 in terms of volume, lesion detectability and image quality. In the group of a b-value of 800 from a b-value of 2000 s/mm2, hepatic lesion sizes were significantly smaller than on acquired DWI (metastases lesion sizes b = 800 vs. b 2000 s/mm2: mean 25 cm3 (range 10-60 cm3) vs. mean 17.5 cm3 (range 5-35 cm3), p < 0.01). In the second group at a high b-value of 1500 s/mm2, liver metastases were larger than on c-DWI at higher b-values (b = 1500 vs. b 2000 s/mm2, mean 10 cm3 (range 4-24 cm3) vs. mean 9 cm3 (range 5-19 cm3), p < 0.01). In both groups, there was a clear reduction in lesion detectability at b = 2000 s/mm2, with hepatic metastases being less visible compared to c-DWI images at b = 1500 s/mm2 in at least 80% of all patients. Image quality dropped significantly starting from c-DWI at b = 3000 s/mm2. In both groups, almost all high b-values images at b = 4000 s/mm2 and 5000 s/mm2 were not diagnostic due to poor image quality. High c-DWI b-values up to b = 1500 s/mm2 offer comparable detectability for hepatic metastases compared to standard DWI. Higher b-value images over 2000 s/mm2 lead to a noticeable reduction in imaging quality, which could hamper diagnosis.
RESUMEN
BACKGROUND: Posterior fossa epidural hematoma rarely occurs in children after traumatic head injury. There is ongoing discussion about appropriate treatment, yet the radiological features regarding the time to resorption of the hematoma or required follow-up imaging are rarely discussed. OBSERVATIONS: The authors presented the case of a 3-year-old child who was under clinical observation and receiving analgetic and antiemetic treatment in whom near-complete hematoma resorption was shown by magnetic resonance imaging as soon as 60 hours after diagnosis. The child was neurologically stable at all times and showed no deficit after observational treatment. Hematoma resorption was much faster than expected. The authors discussed hematoma drainage via the sigmoid sinus. LESSONS: Epidural hematomas in children can be treated conservatively and are resorbed in a timely manner.