Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Int J Cardiol ; 382: 33-39, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37059308

RESUMEN

BACKGROUND: Long-term data on the potential advantages of combining the third-generation subcutaneous implantable cardioverter defibrillator (S-ICD) with modern software upgrade including the "SMART Pass", modern programming strategies and the intermuscular (IM) two-incision implantation technique in arrhythmogenic cardiomyopathy (ACM) with different phenotypic variants are lacking. In this study we evaluated the long-term outcome of patients with ACM who underwent third-generation S-ICD (Emblem, Boston Scientific) and IM two-incision technique. METHODS: The study population included 23 consecutive patients [70% male, median age 31 (24-46) years] diagnosed with ACM with different phenotypic variants who received third-generation S-ICD implantation with the IM two-incision technique. RESULTS: During a median follow-up of 45.5 months [16-65], 4 patients (17.4%) received a at least one inappropriate shock (IS), with median annual event rate of 4.5%. Extra-cardiac oversensing (myopotential) during effort represented the only cause of IS. No IS due to T-wave oversensing (TWOS) were recorded. Only one patient (4.3%) experienced device-related complication consisting of premature cell battery depletion requiring device replacement. No device explantation because of need for anti-tachycardia pacing or ineffective therapy occurred. There was no significant difference between patients who did and did not experienced IS with regard to baseline clinical, ECG and technical characteristics. Five patients (21.7%) received appropriate shocks on ventricular arrythmias. CONCLUSIONS: According to our findings, although the third-generation S-ICD implanted with the IM two-incision technique appears to be associated with a low risk of complications and IS due to cardiac oversensing, the risk of IS due to myopotential mainly during effort should be considered.


Asunto(s)
Cardiomiopatías , Desfibriladores Implantables , Humanos , Masculino , Adulto , Femenino , Desfibriladores Implantables/efectos adversos , Estudios de Seguimiento , Resultado del Tratamiento , Arritmias Cardíacas/diagnóstico , Cardiomiopatías/cirugía , Cardiomiopatías/etiología , Muerte Súbita Cardíaca/etiología
3.
J Cardiovasc Electrophysiol ; 31(7): 1793-1800, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32412155

RESUMEN

INTRODUCTION: Management of subcutaneous implantable cardioverter defibrillator (S-ICD) patients with newly acquired pacing needs remains problematic. His bundle pacing (HBP) allows for cardiac pacing without significant changes in the QRS morphology. We hypothesized that HBP does not alter S-ICD sensing and functions. METHODS: Twenty consecutive patients were implanted with a HB pacemaker. Among them, 17 demonstrated successful His recruitment and were prospectively screened with the automated screening tool (AST). Results of screenings performed immediately after implant and during follow-up, during intrinsic rhythm and while pacing from all available pacing configurations, were compared using the AST score. Positive-screening tests were defined by greater than or equal to 1 positive vector. RESULTS: Among the 17 patients successfully implanted (male: 41%; mean age: 73), 13 presented an indication of ventricular pacing and four of cardiac resynchronization. Absolute AST scores during both HBP (all configurations) and intrinsic rhythm were similar (p: NS). Due to left bundle branch block correction, HBP resulted in higher number of positive vectors (AST ≥ 100). AST scores were higher during HBP when compared with right ventricular pacing (RVP) (primary vector: 272 [16; 648] vs 4.6 [0.8; 16.2]; P = .003; secondary vector: 569 [183; 1186] vs 1.5 [0.7; 8.3]; P < .0001; alternate vector: 44 [2;125] vs 4.8 [0.9; 9.3]; P = .02) and resulted in a much higher number of positive vectors. Up to 90% of the patients had a positive-screening test during HBP. This passing rate was higher when compared RVP (17%; P < .0001). CONCLUSION: HBP restores normal intrinsic conduction and minimally modifies the surface electrocardiograph and subcutaneous electrograms. When ventricular pacing is needed, HBP might represent an ideal pacing option for patients implanted with a S-ICD.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Anciano , Fascículo Atrioventricular , Estimulación Cardíaca Artificial/efectos adversos , Electrocardiografía , Estudios de Factibilidad , Humanos , Masculino , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA