Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
J Orthop Res ; 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38864683

RESUMEN

Full-thickness rotator cuff tears can lead to poor coaptation of the humeral head to the glenoid, disrupting muscle forces required for glenohumeral joint stability, ultimately leading to joint subluxation. The aim of this study was to evaluate muscle forces and glenohumeral joint translations during elevation in the presence of isolated and combined full-thickness rotator cuff tears. Eight fresh-frozen upper limbs were mounted to a computer-controlled testing apparatus that simulated joint motion by simulated muscle force application. Scapular-plane abduction was performed, and glenohumeral joint translations were measured using an optoelectronic system. Testing was performed in the native shoulder, a following an isolated tear to the supraspinatus, as well as combined tears involving the supraspinatus and subscapularis, as well as supraspinatus, infraspinatus, and teres minor. Rotator cuff tears significantly increased middle deltoid force at 30°, 60°, and 90° of abduction relative to that in the native shoulder (p < 0.05). Significantly greater superior translations were observed relative to the intact shoulder due to combined tears to the supraspinatus and infraspinatus at 30° of abduction (mean increase: 1.6 mm, p = 0.020) and 60° of abduction (mean increase: 4.8 mm, p = 0.040). This study illustrates the infraspinatus-teres minor complex as a major humeral head depressor and contributor to glenohumeral joint stability. An increase in deltoid force during abduction occurs in the presence of rotator cuff tears, which exacerbates superior migration of the humeral head. The findings may help in the development of clinical tests in rotator cuff tear diagnostics, in surgical planning of rotator cuff repair, and in planning of targeted rehabilitation.

2.
J Orthop Res ; 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38850264

RESUMEN

Revision total hip arthroplasty (rTHA) involving acetabular defects is a complex procedure associated with lower rates of success than primary THA. Computational modeling has played a key role in surgical planning and prediction of postoperative outcomes following primary THA, but modeling applications in rTHA for acetabular defects remain poorly understood. This study aimed to systematically review the use of computational modeling in acetabular defect classification, implant selection and placement, implant design, and postoperative joint functional performance evaluation following rTHA involving acetabular defects. The databases of Web of Science, Scopus, Medline, Embase, Global Health and Central were searched. Fifty-three relevant articles met the inclusion criteria, and their quality were evaluated using a modified Downs and Black evaluation criteria framework. Manual image segmentation from computed tomography scans, which is time consuming, remains the primary method used to generate 3D models of hip bone; however, statistical shape models, once developed, can be used to estimate pre-defect anatomy rapidly. Finite element modeling, which has been used to estimate bone stresses and strains, and implant micromotion postoperatively, has played a key role in custom and off-the-shelf implant design, mitigation of stress shielding, and prediction of bone remodeling and implant stability. However, model validation is challenging and requires rigorous evaluation and comparison with respect to mid- to long-term clinical outcomes. Development of fast, accurate methods to model acetabular defects, including statistical shape models and artificial neural networks, may ultimately improve uptake of and expand applications in modeling and simulation of rTHA for the research setting and clinic.

3.
Biomech Model Mechanobiol ; 23(3): 809-823, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38502434

RESUMEN

Total temporomandibular joint replacement (TMJR) surgery is the established treatment for severe temporomandibular joint disorders. While TMJR surgery is known to increase mouth-opening capacity, reduce pain and improve quality of life, little is known about post-surgical jaw function during activities of daily living such as biting and chewing. The aim of this study was to use subject-specific 3D bite force measurements to evaluate the magnitude and direction of joint loading in unilateral total TMJR patients and compare these data to those in healthy control subjects. An optoelectronic tracking system was used to measure jaw kinematics while biting a rubber sample for 5 unilateral total TMJR patients and 8 controls. Finite element simulations driven by the measured kinematics were employed to calculate the resultant bite force generated when compressing the rubber between teeth during biting tasks. Subject-specific musculoskeletal models were subsequently used to calculate muscle and TMJ loading. Unilateral total TMJR patients generated a bite force of 249.6 ± 24.4 N and 164.2 ± 62.3 N when biting on the contralateral and ipsilateral molars, respectively. In contrast, controls generated a bite force of 317.1 ± 206.6 N. Unilateral total TMJR patients biting on the contralateral molars had a significantly higher lateral TMJ force direction (median difference: 63.6°, p = 0.028) and a significantly lower ratio of working TMJ force to bite force (median difference: 0.17, p = 0.049) than controls. Results of this study may guide TMJ prosthesis design and evaluation of dental implants.


Asunto(s)
Fuerza de la Mordida , Análisis de Elementos Finitos , Articulación Temporomandibular , Humanos , Articulación Temporomandibular/fisiopatología , Fenómenos Biomecánicos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Artroplastia de Reemplazo , Masticación/fisiología , Estudios de Casos y Controles , Músculos/fisiopatología , Músculos/fisiología , Trastornos de la Articulación Temporomandibular/fisiopatología
4.
J Orthop Res ; 42(3): 588-597, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37812185

RESUMEN

Subacromial impingement (SAI) is associated with shoulder pain and dysfunction and is exacerbated by rotator cuff tears; however, the role of acromioplasty in mitigating subacromial contact in the rotator cuff deficient shoulder remains debated. This study aimed to quantify the influence of isolated and combined tears involving the supraspinatus on subacromial contact during abduction; and second, to evaluate the influence of acromioplasty on joint space size and subacromial contact under these pathological conditions. Eight fresh-frozen human cadaveric upper limbs were mounted to a computer-controlled testing apparatus that simulated joint motion by simulated force application. Shoulder abduction was performed while three-dimensional joint kinematics was measured using an optoelectronic system, and subacromial contact evaluated using a digital pressure sensor secured to the inferior acromion. Testing was performed after an isolated tear to the supraspinatus, as well as tears involving the subscapularis and infraspinatus-teres minor, both before and after acromioplasty. Rotator cuff tears significantly increased peak subacromial pressure (p < 0.001), average subacromial pressure (p = 0.001), and contact force (p = 0.034) relative to those in the intact shoulder. Following acromioplasty, significantly lower peak subacromial contact pressure, force and area were observed for all rotator cuff tears involving the supraspinatus at 30° of abduction (p < 0.05). Acromioplasty predominantly reduces acromion thickness anteriorly thereby reducing subacromial contact in the rotator cuff deficient shoulder, particularly in early to mid-abduction where superior glenohumeral joint shear force potential is large. These findings provide a biomechanical basis for acromioplasty as an intervention for SAI syndrome and as an adjunct to rotator cuff repairs.


Asunto(s)
Lesiones del Manguito de los Rotadores , Articulación del Hombro , Humanos , Manguito de los Rotadores/cirugía , Hombro , Lesiones del Manguito de los Rotadores/cirugía , Rotura , Fenómenos Biomecánicos , Cadáver , Rango del Movimiento Articular
5.
J Orthop Res ; 42(6): 1159-1169, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38159105

RESUMEN

The Latarjet procedure is an established surgical treatment for recurrent glenohumeral joint instability with glenoid bone loss. Intraoperatively, the conjoint tendon and its attachement on the coracoid bone graft is routed through a split in subscapularis where the graft is fixed to and augments the anteroinferior glenoid. The objective of this in vitro study was to quantify the influence of glenohumeral joint position and conjoint tendon force on the lines of action and moment arms of subscapularis muscle sub-regions after Latarjet surgery. Eight fresh-frozen, entire upper extremities were mounted onto a testing apparatus, and a cable-pulley system was used to apply physiological muscle loading to the major shoulder muscles. The lines of action and moment arms of four subregions of subscapularis (superior, mid-superior, mid-inferior, and inferior) were quantified radiographically with the conjoint tendon unloaded and loaded while the shoulder was in (i) 0° abduction (ii) 90° abduction (iii) 90° abduction and full external rotation (ABER), and (iv) the apprehension position, defined as ABER with 30° horizontal extension. Conjoint tendon loading after Latarjet surgery significantly increased the inferior inclination of the lines of action of the mid-inferior and inferior subregions of subscapularis in the scapular plane in ABER and apprehension positions (p < 0.001), as well as decreased the horizontal flexion moment arm of the inferior subscapularis (p = 0.040). Increased subscapularis inferior inclination may ultimately increase inferior joint shear potential, while smaller horizontal flexion leverage may reduce joint flexion capacity. The findings have implications for Latarjet surgical planning and postoperative rehabilitation prescription.


Asunto(s)
Articulación del Hombro , Humanos , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Articulación del Hombro/fisiología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Inestabilidad de la Articulación/cirugía , Inestabilidad de la Articulación/fisiopatología , Tendones/cirugía , Músculo Esquelético , Fenómenos Biomecánicos
6.
JBMR Plus ; 7(12): e10828, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38130762

RESUMEN

Dual-energy X-ray absorptiometry (DXA) scans are one of the most frequently used imaging techniques for calculating bone mineral density, yet calculating fracture risk using DXA image features is rarely performed. The objective of this study was to combine deep neural networks, together with DXA images and patient clinical information, to evaluate fracture risk in a cohort of adults with at least one known fall and age-matched healthy controls. DXA images of the entire body as, well as isolated images of the hip, forearm, and spine (1488 total), were obtained from 478 fallers and 48 non-faller controls. A modeling pipeline was developed for fracture risk prediction using the DXA images and clinical data. First, self-supervised pretraining of feature extractors was performed using a small vision transformer (ViT-S) and a convolutional neural network model (VGG-16 and Resnet-50). After pretraining, the feature extractors were then paired with a multilayer perceptron model, which was used for fracture risk classification. Classification was achieved with an average area under the receiver-operating characteristic curve (AUROC) score of 74.3%. This study demonstrates ViT-S as a promising neural network technique for fracture risk classification using DXA scans. The findings have future application as a fracture risk screening tool for older adults at risk of falls. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

7.
J Biomech ; 159: 111741, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37660523

RESUMEN

Total temporomandibular joint (TMJ) replacement surgery aims to improve mandibular function, reduce pain and enhance quality of life in patients suffering from end-stage TMJ disorders. Traditional post-operative jaw evaluation is carried out using measurement of maximum interincisal opening distance; however, this can correlate poorly to joint function. The present study aimed to evaluate three-dimensional (3D) jaw motion during border movements and chewing in unilateral total TMJ replacement patients and healthy controls. Motion analysis experiments were performed on six unilateral total TMJ replacement patients and ten age-matched healthy controls. Subject-specific motion tracking plates worn by each participant were registered to CT scans of each participant's skull and mandible to enable anatomical mandibular kinematics measurement using an optoelectronic system. Participants performed 15 repetitions of maximal opening, protrusion, lateral excursions, and chewing cycles. Total TMJ replacement patients had significantly smaller incisal displacements at maximum mouth opening relative to the controls (median difference: 7.1 mm, p = 0.002) and decreased anterior translation of the prosthetic condyle (median difference: 10.5 mm, p = 0.002). When TMJ replacement subjects chewed using their contralateral molars, there was a significant increase in inferior condylar translation of the non-working condyle (median difference: 9.7 mm, p = 0.016). This study found that unilateral total TMJ replacement surgery was associated with mouth opening capacity within the range of healthy individuals, but reduced anterior movement of the prosthetic condyle and restricted protrusion and lateral excursions. The results provide future direction for prosthetic TMJ design to enhance postsurgical implant functionality and improve long-term clinical outcomes for prosthesis recipients.


Asunto(s)
Prótesis Articulares , Calidad de Vida , Humanos , Fenómenos Biomecánicos , Articulación Temporomandibular/diagnóstico por imagen , Articulación Temporomandibular/cirugía , Mandíbula , Rango del Movimiento Articular , Cóndilo Mandibular
8.
Am J Sports Med ; 51(9): 2454-2464, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37724693

RESUMEN

BACKGROUND: Glenohumeral joint contact loading before and after glenoid bone grafting for recurrent anterior instability remains poorly understood. PURPOSE: To develop a computational model to evaluate the influence of glenoid bone loss and graft positioning on graft and cartilage contact pressures after the Latarjet procedure. STUDY DESIGN: Controlled laboratory study. METHODS: A finite element model of the shoulder was developed using kinematics, muscle and glenohumeral joint loading of 6 male participants. Muscle and joint forces at 90° of abduction and external rotation were calculated and employed in simulations of the native shoulder, as well as the shoulder with a Bankart lesion, 10% and 25% glenoid bone loss, and after the Latarjet procedure. RESULTS: A Bankart lesion as well as glenoid bone loss of 10% and 25% significantly increased glenoid and humeral cartilage contact pressures compared with the native shoulder (P < .05). The Latarjet procedure did not significantly increase glenoid cartilage contact pressure. With 25% glenoid bone loss, the Latarjet procedure with a graft flush with the glenoid and the humerus positioned at the glenoid half-width resulted in significantly increased humeral cartilage contact pressure compared with that preoperatively (P = .023). Under the same condition, medializing the graft by 1 mm resulted in humeral cartilage contact pressure comparable with that preoperatively (P = .097). Graft lateralization by 1 mm resulted in significantly increased humeral cartilage contact pressure in both glenoid bone loss conditions (P < .05). CONCLUSION: This modeling study showed that labral damage and greater glenoid bone loss significantly increased glenoid and humeral cartilage contact pressures in the shoulder. The Latarjet procedure may mitigate this to an extent, although glenoid and humeral contact loading was sensitive to graft placement. CLINICAL RELEVANCE: The Latarjet procedure with a correctly positioned graft should not lead to increased glenohumeral joint contact loading. The present study suggests that lateral graft overhang should be avoided, and in the situation of large glenoid bone defects, slight medialization (ie, 1 mm) of the graft may help to mitigate glenohumeral joint contact overloading.


Asunto(s)
Lesiones de Bankart , Enfermedades Óseas , Masculino , Humanos , Cartílago , Escápula , Húmero/cirugía
9.
Am J Sports Med ; 51(7): 1895-1903, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37184036

RESUMEN

BACKGROUND: Extracortical single-button (SB) inlay repair is a commonly used distal biceps tendon technique. However, complications (eg, neurovascular injury) and nonanatomic repairs have led to the development of intracortical fixation techniques. PURPOSE: To compare the biomechanical stability of extracortical SB repair with an anatomic intracortical double-button (DB) repair technique. STUDY DESIGN: Controlled laboratory study. METHODS: The distal biceps tendon was transected in 18 cadaveric elbows from 9 donors. One elbow of each donor was randomly assigned to the extracortical SB or anatomic DB group. Both groups were cyclically loaded with 60 N over 1000 cycles between 90° of flexion and full extension. The elbow was then fixed in 90° of flexion and the repair construct loaded to failure. Gap formation and construct stiffness during cyclic loading and ultimate load to failure were analyzed. RESULTS: When compared with the extracortical SB technique after 1000 cycles, the anatomic DB technique showed significantly less gap formation (mean ± SD, 2.7 ± 0.8 vs 1.5 ± 0.9 mm; P = .017) and significantly more construct stiffness (87.4 ± 32.7 vs 119.9 ± 31.6 N/mm; P = .023). Ultimate load to failure was not significantly different between the groups (277 ± 93 vs 285 ± 135 N; P = .859). The failure mode in the anatomic DB group was significantly different from that of the extracortical SB technique (P = .002) and was due to fracture avulsion of the cortical button in 7 of 9 specimens (vs none in the SB group). CONCLUSION: Our study shows that the intracortical DB technique produces equivalent or superior biomechanical performance to that of the SB technique. The DB technique may offer a clinically viable alternative to the SB repair technique. CLINICAL RELEVANCE: This study suggests, at worst, an equivalent and, at best, a superior biomechanical performance of intracortical anatomic DB footprint repair at the time of surgery. However, the mode of failure suggests that this technique should not be used in patients with poor bone quality.


Asunto(s)
Articulación del Codo , Traumatismos de los Tendones , Humanos , Codo/cirugía , Traumatismos de los Tendones/cirugía , Tendones/cirugía , Articulación del Codo/cirugía , Técnicas de Sutura , Fenómenos Biomecánicos , Cadáver
10.
J Orthop Surg Res ; 18(1): 42, 2023 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-36647070

RESUMEN

BACKGROUND: Total joint replacements are an established treatment for patients suffering from reduced mobility and pain due to severe joint damage. Aseptic loosening due to stress shielding is currently one of the main reasons for revision surgery. As this phenomenon is related to a mismatch in mechanical properties between implant and bone, stiffness reduction of implants has been of major interest in new implant designs. Facilitated by modern additive manufacturing technologies, the introduction of porosity into implant materials has been shown to enable significant stiffness reduction; however, whether these devices mitigate stress-shielding associated complications or device failure remains poorly understood. METHODS: In this systematic review, a broad literature search was conducted in six databases (Scopus, Web of Science, Medline, Embase, Compendex, and Inspec) aiming to identify current design approaches to target stress shielding through controlled porous structures. The search keywords included 'lattice,' 'implant,' 'additive manufacturing,' and 'stress shielding.' RESULTS: After the screening of 2530 articles, a total of 46 studies were included in this review. Studies focusing on hip, knee, and shoulder replacements were found. Three porous design strategies were identified, specifically uniform, graded, and optimized designs. The latter included personalized design approaches targeting stress shielding based on patient-specific data. All studies reported a reduction of stress shielding achieved by the presented design. CONCLUSION: Not all studies used quantitative measures to describe the improvements, and the main stress shielding measures chosen varied between studies. However, due to the nature of the optimization approaches, optimized designs were found to be the most promising. Besides the stiffness reduction, other factors such as mechanical strength can be considered in the design on a patient-specific level. While it was found that controlled porous designs are overall promising to reduce stress shielding, further research and clinical evidence are needed to determine the most superior design approach for total joint replacement implants.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis e Implantes , Humanos , Porosidad , Diseño de Prótesis
11.
J Shoulder Elbow Surg ; 32(4): 695-702, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36535559

RESUMEN

BACKGROUND: Neer type IIB lateral clavicle fractures are inherently unstable fractures with associated disruption of the coracoclavicular (CC) ligaments. Because of the high rate of nonunion and malunion, surgical fixation is recommended; however, no consensus has been reached regarding the optimal fixation method. A new plating technique using a superior lateral locking plate with anteroposterior (AP) locking screws, resulting in orthogonal fixation in the lateral fragment, has been designed to enhance stability and reduce implant failure. The purpose of this study was to biomechanically compare 3 different clavicle plating constructs within a fresh frozen human cadaveric shoulder model. METHODS: Twenty-four fresh frozen cadaveric shoulders were randomized into 3 groups (n = 8 specimens): group 1, lateral locking plate only (Medartis Aptus Superior Lateral Plate); group 2, lateral locking plate with CC stabilization (No. 2 FiberWire); and group 3, lateral locking plate with 2 AP locking screws stabilizing the lateral fragment. All specimens were subject to cyclic loading of 70 N for 500 cycles. Data were analyzed for gap formation after cyclic loading, construct stiffness, and ultimate load to failure, defined by a marked decrease in the load displacement curve. RESULTS: After 500 cycles, there was no statistically significant difference between the 3 groups in gap formation (P = .179). No specimen (0/24) failed during cyclic loading. Ultimate load to failure was significantly higher in group 3 compared to group 1 (286 N vs. 167 N; P = .022), but not to group 2 (286 N vs. 246 N; P = .604). There were no statistically significant differences in stiffness (group 1: 504 N/mm; group 2: 564 N/mm; group 3: 512 N/mm; P = .712). Peri-implant fracture was the primary mode of failure for all 3 groups, with group 3 demonstrating the lowest rate of peri-implant fractures (group 1: 6/8; group 2: 7/8; group 3: 4/8; P = .243). CONCLUSION: Biomechanical evaluation of the clavicle plating techniques showed effective fixation across all specimens at 500 cycles. The lateral locking plate with orthogonal AP locking screw fixation in the lateral fragment demonstrated the greatest ultimate failure load, followed by the lateral locking plate with CC stabilization. This new plating technique showed compatible stiffness and gap formation when compared to conventional lateral locking plates as well as plates with CC fixation. The use of orthogonal screw fixation in the distal fragment may negate against the need for CC stabilization in these types of fractures, thus minimizing surgical dissection around the coracoid and potential complications.


Asunto(s)
Clavícula , Fracturas Óseas , Humanos , Fenómenos Biomecánicos , Placas Óseas , Cadáver , Clavícula/cirugía , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Ligamentos Articulares
12.
Clin Biomech (Bristol, Avon) ; 100: 105775, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36242953

RESUMEN

BACKGROUND: Altered shoulder kinematics in patients with recurrent anterior shoulder instability remains poorly understood. This prospective study aimed to quantify in vivo glenohumeral and scapulothoracic joint kinematics and joint-contact positions in patients with shoulder instability and healthy controls. METHODS: Twenty patients with recurrent anterior shoulder instability (mean 28 years) and five patients without shoulder pathology (mean 39 years) were scanned using open CT in six static upper limb positions including 90° of abduction, combined abduction and external rotation, 90° of flexion, lift-off position (i.e. reaching behind the back) and the neutral shoulder with external rotation. Image datasets were digitally reconstructed to quantify shoulder joint kinematics and glenohumeral translation. FINDINGS: At 90° of abduction, instability patients demonstrated significantly less glenohumeral abduction and a reciprocal increase in upward scapulothoracic rotation compared to controls (mean difference: 13.3°, p = 0.038). With the shoulder in combined abduction and external rotation, instability patients showed a significant increase in glenohumeral rotation and a reciprocal decrease in scapulothoracic rotation compared to controls (mean difference: 5.0°, p = 0.042). There were no significant differences in humeral head translation in the sagittal plane (anterior-posterior axis) for all motions tested (p > 0.05). INTERPRETATION: Scapulothoracic and glenohumeral kinematics are significantly different between patients with recurrent anterior shoulder instability and those with a healthy shoulder. Instability patients compensate for reduced glenohumeral function during abduction by increasing scapular rotation. With the shoulder in combined abduction and external rotation position, greater glenohumeral joint angles without significantly increased humeral head translation suggest altered neuromuscular control in the unstable shoulder.


Asunto(s)
Inestabilidad de la Articulación , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Estudios Prospectivos , Hombro
13.
J Clin Med ; 11(19)2022 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-36233382

RESUMEN

Bone graft resorption following the Latarjet procedure has received considerable concern. Current methods quantifying bone graft resorption rely on two-dimensional (2D) CT-scans or three-dimensional (3D) techniques, which do not represent the whole graft volume/resorption (i.e., 2D assessment) or expose patients to additional radiation (i.e., 3D assessment) as this technique relies on early postoperative CT-scans. The aim of the present study was to develop and validate a patient-specific, CT-morphometric technique combining image registration with 3D CT-reconstruction to quantify bone graft resorption following the Latarjet procedure for recurrent anterior shoulder instability. Pre-operative and final follow-up CT-scans were segmented to digitally reconstruct 3D scapula geometries. A virtual Latarjet procedure was then conducted to model the timepoint-0 graft volume, which was compared with the final follow-up graft volume. Graft resorption at final follow-up was highly correlated to the 2D gold standard-technique by Zhu (Kendall tau coefficient = 0.73; p < 0.001). The new technique was also found to have excellent inter- and intra-rater reliability (ICC values, 0.931 and 0.991; both p < 0.001). The main finding of this study is that the technique presented is a valid and reliable method that provides the advantage of 3D-assessment of graft resorption at long-term follow-up without the need of an early postoperative CT-scan.

14.
J Appl Biomech ; 38(6): 365-372, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36180043

RESUMEN

Dual-task walking and cell phone usage, which is associated with high cognitive load and reduced situational awareness, can increase risk of a collision, a fall event, or death. The objective of this study was to quantify the effect of dual-task cell phone talking, texting, and reading while walking on spatiotemporal gait parameters; minimum foot clearance; and dynamic stability of the lower limb joints, trunk, and head. Nineteen healthy male participants walked on an instrumented treadmill at their self-selected speed as well as walking while simultaneously (1) reading on a cell phone, (2) texting, and (3) talking on a cell phone. Gait analyses were performed using an optical motion analysis system, and dynamic stability was calculated using the Maximum Lyapunov Exponent. Dual-task cell phone usage had a significant destabilizing influence on the lower limb joints during walking. Cell phone talking while walking significantly increased step width and length and decreased minimum foot clearance height (P < .05). The findings suggest that dual-task walking and cell phone conversation may present a greater risk of a fall event than texting or reading. This may be due to the requirements for more rapid information processing and cognitive demand at the expense of motor control of joint stability.


Asunto(s)
Teléfono Celular , Envío de Mensajes de Texto , Masculino , Humanos , Fenómenos Biomecánicos , Caminata , Marcha
15.
J Orthop Surg Res ; 17(1): 224, 2022 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-35399075

RESUMEN

BACKGROUND: Lumbar interbody fusion (LIF) is an established surgical intervention for patients with leg and back pain secondary to disc herniation or degeneration. Interbody fusion involves removal of the herniated or degenerated disc and insertion of interbody devices with bone grafts into the remaining cavity. Extensive research has been conducted on operative complications such as a failure of fusion or non-union of the vertebral bodies. Multiple factors including surgical, implant, and patient factors influencing the rate of complications have been identified. Patient factors include age, sex, osteoporosis, and patient anatomy. Complications can also be influenced by the interbody cage design. The geometry of the bony endplates as well as their corresponding material properties guides the design of interbody cages, which vary considerably across patients with spinal disorders. However, studies on the effects of such variations on the rate of complications are limited. Therefore, this study aimed to perform a systematic review of lumbar endplate geometry and material property factors in LIF failure. METHODS: Search keywords included 'factor/cause for spinal fusion failure/cage subsidence/cage migration/non-union', 'lumbar', and 'interbody' in electronic databases PubMed and Scopus with no limits on year of publication. RESULTS: In total, 1341 articles were reviewed, and 29 articles were deemed suitable for inclusion. Adverse events after LIF, such as cage subsidence, cage migration, and non-union, resulted in fusion failure; hence, risk factors for adverse events after LIF, notably those associated with lumbar endplate geometry and material properties, were also associated with fusion failure. Those risk factors were associated with shape, concavity, bone mineral density and stiffness of endplate, segmental disc angle, and intervertebral disc height. CONCLUSIONS: This review demonstrated that decreased contact areas between the cage and endplate, thin and weak bony endplate as well as spinal diseases such as spondylolisthesis and osteoporosis are important causes of adverse events after LIF. These findings will facilitate the selection and design of LIF cages, including customised implants based on patient endplate properties.


Asunto(s)
Osteoporosis , Enfermedades de la Columna Vertebral , Fusión Vertebral , Espondilolistesis , Humanos , Vértebras Lumbares/cirugía , Región Lumbosacra , Fusión Vertebral/métodos , Espondilolistesis/cirugía
16.
J Shoulder Elbow Surg ; 31(7): 1376-1384, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35167913

RESUMEN

HYPOTHESIS: Simple transverse or short oblique olecranon fractures without articular comminution are classified as Mayo type IIA fractures and are typically treated with a tension band wire construct. Because of the high reoperation rates, frequently because of prominent hardware, all-suture tension band constructs have been introduced. It was the purpose to compare the biomechanical performance of conventional tension band wire fixation with a new all-suture tension band tape fixation for simple olecranon fractures. METHODS: Mayo type IIA olecranon fractures were created in 20 cadaveric elbows from 10 donors. One elbow of each donor was randomly assigned to the tension band wire technique (group TBW) or tension band tape (Arthrex, 1.3-mm SutureTape) technique (group TBT). Both groups were cyclically loaded with 500 N over 500 cycles, after which a uniaxial displacement was performed to evaluate load to failure. Data were analyzed for gap formation after cyclic loading, construct stiffness, and ultimate load to failure, where failure was defined as fracture gap formation greater than 4.0 mm. RESULTS: There was no significant difference in gap formation after 500 cycles between the TBW (1.8 mm ± 1.3 mm) and the TBT (1.9 mm ± 1.1 mm) groups (P = .854). The TBT showed a tendency toward greater construct stiffness compared with the TBW construct (mean difference: 142 N/mm; P = .053). Ultimate load to failure was not significantly different comparing both groups (TBW: 1138 N ± 286 N vs. TBT: 1126 N ± 272 N; P = .928). In both groups, all repairs failed because of >4.0-mm gap formation at the fracture site and none because of tension band construct breakage. CONCLUSIONS: Our study shows that the TBT technique produces equivalent or superior biomechanical performance to the TBW for simple olecranon fractures. The TBT approach reduces the risk of hardware prominence and as a result mitigates against the need for hardware removal. The TBT technique offers a clinically viable alternative to TBW.


Asunto(s)
Fracturas Óseas , Olécranon , Fracturas del Cúbito , Fenómenos Biomecánicos , Hilos Ortopédicos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Humanos , Olécranon/cirugía , Suturas , Fracturas del Cúbito/cirugía
17.
J Clin Med ; 11(2)2022 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-35054057

RESUMEN

BACKGROUND: Acromial and scapular spine fractures after reverse total shoulder arthroplasty (RTSA) can be devastating complications leading to substantial functional impairments. The purpose of this study was to review factors associated with increased acromial and scapular spine strain after RTSA from a biomechanical standpoint. METHODS: A systematic review of the literature was conducted based on PRISMA guidelines. PubMed, Embase, OVID Medline, and CENTRAL databases were searched and strict inclusion and exclusion criteria were applied. Each article was assessed using the modified Downs and Black checklist to appraise the quality of included studies. Study selection, extraction of data, and assessment of methodological quality were carried out independently by two of the authors. Only biomechanical studies were considered. RESULTS: Six biomechanical studies evaluated factors associated with increased acromial and scapular spine strain and stress. Significant increases in acromial and scapular spine strain were found with increasing lateralization of the glenosphere in four of the included studies. In two studies, glenosphere inferiorization consistently reduced acromial strain. The results concerning humeral lateralization were variable between four studies. Humeral component neck-shaft angle had no significant effect on acromial strain as analysed in one study. One study showed that scapular spine strain was significantly increased with a more posteriorly oriented acromion (55° vs. 43°; p < 0.001). Another study showed that the transection of the coracoacromial ligament increased scapular spine strain in all abduction angles (p < 0.05). CONCLUSIONS: Glenoid lateralization was consistently associated with increased acromial and scapular spine strain, whereas inferiorization of the glenosphere reduced strain in the biomechanical studies analysed in this systematic review. Humeral-sided lateralization may increase or decrease acromial or scapular spine strain. Independent of different design parameters, the transection of the coracoacromial ligament resulted in significantly increased strains and scapular spine strains were also increased when the acromion was more posteriorly oriented. The results found in this systematic review of biomechanical in-silico and in-vitro studies may help in the surgical planning of RTSA to mitigate complications associated with acromion and scapular spine fracture.

18.
J Hand Surg Eur Vol ; 47(2): 172-178, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34018870

RESUMEN

We compared four methods of metacarpal shaft fixation: 2.2 mm intramedullary headless compression screw; 3.0 mm intramedullary headless compression screw; intramedullary K-wire fixation; and dorsal plate fixation. Transverse mid-diaphyseal fractures were created in 64 metacarpal sawbones and were assigned into four groups. Peak load to failure and stiffness were measured in cantilever bending and torsion. We found that dorsal plating had the highest peak load to failure. However, initial bending stiffness of the 3.0 mm intramedullary headless compression screw was higher than that of the dorsal plates. In torsion testing, dorsal plating had the highest peak torque, but there was no significant difference in torsional stiffness between the plate and intramedullary headless compression screw constructs. We concluded that intramedullary headless compression screw fixation is biomechanically superior to K-wires in cantilever bending and torsion; however, it is less stable than dorsal plating. In our study, the initial stability provided by K-wire fixation was sufficient to cope with expected loads in the early rehabilitation period, whereas dorsal plates and IHCS constructs provided stability far in excess of what is required.


Asunto(s)
Fracturas Óseas , Huesos del Metacarpo , Fenómenos Biomecánicos , Placas Óseas , Tornillos Óseos , Hilos Ortopédicos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Humanos , Huesos del Metacarpo/cirugía
19.
Biomech Model Mechanobiol ; 21(1): 249-259, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34837584

RESUMEN

Evaluation of the bony anatomy of the glenohumeral joint is frequently required for surgical planning and subject-specific computational modeling and simulation. The three-dimensional geometry of bones is traditionally obtained by segmenting medical image datasets, but this can be time-consuming and may not be practical in the clinical setting. The aims of this study were twofold. Firstly, to develop and validate a statistical shape modeling approach to rapidly reconstruct the complete scapular and humeral geometries using discrete morphometric measurements that can be quickly and easily measured directly from CT, and secondly, to assess the effectiveness of statistical shape modeling in reconstruction of the entire humerus using just the landmarks in the immediate vicinity of the glenohumeral joint. The most representative shape prediction models presented in this study achieved complete scapular and humeral geometry prediction from seven or fewer morphometric measurements and yielded a mean surface root mean square (RMS) error under 2 mm. Reconstruction of the entire humerus was achieved using information of only proximal humerus bony landmarks and yielding mean surface RMS errors under 3 mm. The proposed statistical shape modeling facilitates rapid generation of 3D anatomical models of the shoulder, which may be useful in rapid development of personalized musculoskeletal models.


Asunto(s)
Articulación del Hombro , Fenómenos Biomecánicos , Húmero/anatomía & histología , Húmero/diagnóstico por imagen , Modelos Anatómicos , Modelos Estadísticos , Escápula/anatomía & histología , Articulación del Hombro/anatomía & histología , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía
20.
J Clin Med ; 10(22)2021 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-34830616

RESUMEN

Reverse total shoulder arthroplasty (RTSA) is an established treatment for elderly patients with irreparable rotator cuff tears, complex proximal humerus fractures, and revision arthroplasty; however, with the increasing indications for RTSA over the last decade and younger implant recipients, post-operative complications have become more frequent, which has driven advances in computational modeling and simulation of reverse shoulder biomechanics. The objective of this study was to provide a review of previously published studies that employed computational modeling to investigate complications associated with RTSA. Models and applications were reviewed and categorized into four possible complications that included scapular notching, component loosening, glenohumeral joint instability, and acromial and scapular spine fracture, all of which remain a common cause of significant functional impairment and revision surgery. The computational shoulder modeling studies reviewed were primarily used to investigate the effects of implant design, intraoperative component placement, and surgical technique on postoperative shoulder biomechanics after RTSA, with the findings ultimately used to elucidate and mitigate complications. The most significant challenge associated with the development of computational models is in the encapsulation of patient-specific anatomy and surgical planning. The findings of this review provide a basis for future direction in computational modeling of the reverse shoulder.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA