Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38430087

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Masculino , Femenino , Anciano , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Estudios Retrospectivos , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Resultado del Tratamiento , Sistema de Registros
2.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38340118

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Sistema de Registros , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Europa (Continente) , Resultado del Tratamiento , Recurrencia , Reoperación/estadística & datos numéricos
3.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37910101

RESUMEN

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Asunto(s)
Fibrilación Atrial , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adolescente , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Estudios de Cohortes , Factores Sexuales , Resultado del Tratamiento
4.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37498147

RESUMEN

AIMS: Electrophysiology (EP) is a growing field in cardiology, with an increasing involvement of young people. Nevertheless, concerns about radiation exposure and its impact on reproduction and pregnancy may discourage the choice of an EP career. The study is aimed at investigating the level of awareness and main sources of concern about the effects of radiation on reproductive potential and pregnancy, exploring the safety measures adopted in different EP labs, and verifying the adherence to the current guidelines. METHODS AND RESULTS: An online survey was conducted using the European Heart Rhythm Association (EHRA) infrastructure from April to June 2022. A total of 252 EP personnel (42% women) participated, from 50 countries and different professional roles. Most participants expressed concerns regarding the effects of radiation on reproductive capacity (67.1%) and offspring diseases (68.2%). Only 37.9% of participants were aware of the EHRA 2017 consensus document about occupational radiation exposure. Most participants (80.9%) considered that occupational radiation during pregnancy is not safe. EP female staff were not allowed to work in the EP lab during pregnancy in 48.1% of cases. Zero-fluoroscopy was the preferred choice to continue working in the EP lab during pregnancy. CONCLUSION: EP staff, including both men and women, have concerns about the effects of radiation on reproductive capacity. Despite the recommendations issued by international bodies, implementation of the policies regarding pregnancy and occupational radiation exposure is heterogeneous. Zero-fluoroscopy is the preferred approach to ensure safety during pregnancy in the EP lab.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Traumatismos por Radiación , Masculino , Embarazo , Femenino , Humanos , Adolescente , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Encuestas y Cuestionarios , Reproducción , Electrofisiología Cardíaca , Exposición Profesional/efectos adversos , Exposición Profesional/prevención & control , Dosis de Radiación
5.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37379528

RESUMEN

AIMS: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. METHODS AND RESULTS: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. CONCLUSION: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Poria , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fluoroscopía , Venas Pulmonares/cirugía , Recurrencia
6.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1070-1081, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37354173

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) is a new and promising modality of ablation that has been shown to specifically ablate cardiac tissue while sparing other anatomic structures, thus avoiding thermal ablation-related complications. Recent studies have certified safety and efficacy of PFA for pulmonary vein isolation (PVI) in the setting of paroxysmal atrial fibrillation (AF). However, there are very limited data assessing the feasibility and safety of PFA ablation of different substrates within the left atrium in the setting of persistent AF. OBJECTIVES: The purpose of this study was to evaluate the feasibility and safety of mitral isthmus (MI) ablation in addition to PVI and posterior wall (PW) ablation with PFA in patients with persistent AF. METHODS: We prospectively included all consecutive patients with persistent AF who underwent a first ablation procedure with PFA. We performed in all these patients a substrate ablation strategy comprising PVI, PW, and MI ablation with the use of PFA only. The primary feasibility endpoint was obtaining a persistent MI block at the end of the procedure. The safety endpoint was a composite of major safety events. RESULTS: From November 2021 to September 2022, we included 45 patients. Complete MI block was achieved in all 45 (100%). Three patients presented with complications, among them 2 cases (4.4%) of reversible and nonfatal coronary spasm. During a mean follow-up time of 107.8 ± 59.5 days, a 20% recurrence rate was observed. CONCLUSIONS: PFA is a feasible and safe ablation approach for mitral isthmus ablation in addition to PVI in patients with persistent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Datos Preliminares , Resultado del Tratamiento , Atrios Cardíacos , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
7.
Circulation ; 148(1): 35-46, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37199171

RESUMEN

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Aleteo Atrial/etiología , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
9.
J Interv Card Electrophysiol ; 66(3): 683-691, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36207558

RESUMEN

BACKGROUND: Adequate synchronization between the passive ("E") and active ("a") left ventricular (LV) diastolic filling contributes to the efficiency of the heartbeat. E/a superposition in dual-chamber pacemaker (PM) recipients is an under-recognized phenomenon that may be corrected by shortening the atrio-ventricular interval (AVI). We aimed at establishing the prevalence of E/a superposition in PM patients and to analyze the clinical, echocardiographic, and biological impact of AVI shortening. METHODS: Seventy patients with dual-chamber PMs (74 ± 8 years old, 12 women) were consecutively enrolled in this study. Patients with baseline E/a superposition were crossed over from default to manually shortened AVI or vice versa in a case-control fashion (intervention group). Patients without baseline E/a superposition (controls) served as a reference for a descriptive comparison with the intervention group. RESULTS: Thirty-three patients had E/a superposition after PM implantation (47%). Controls (n = 37) had higher LV ejection fraction (59 ± 8% vs. 53 ± 10%, p = 0.048) and lower levels of high sensitive troponin T and ST2 (p < 0.05) than intervention group patients. The AVI was shortened at 48 ± 9 ms in order to ensure adequate E/a separation. The walked distance increased from 75 ± 17 to 78 ± 10% (p = 0.049) and the Euro-QoL score from 0.50 ± 0.27 to 0.63 ± 0.19 (p = 0.011) with short AVI. CONCLUSIONS: E/a superposition occurs in approximately half of dual-chamber PM recipients and is associated with reduced LV function and increased myocardial injury biomarkers. AVI shortening produces a modest but significant effect in functional capacity and quality of life.


Asunto(s)
Marcapaso Artificial , Calidad de Vida , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Estimulación Cardíaca Artificial , Diástole , Función Ventricular Izquierda
10.
Front Cardiovasc Med ; 9: 983001, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36204562

RESUMEN

Objective: To assess the arrhythmic safety profile of the adipose graft transposition procedure (AGTP) and its electrophysiological effects on post-myocardial infarction (MI) scar. Background: Myocardial repair is a promising treatment for patients with MI. The AGTP is a cardiac reparative therapy that reduces infarct size and improves cardiac function. The impact of AGTP on arrhythmogenesis has not been addressed. Methods: MI was induced in 20 swine. Contrast-enhanced magnetic resonance (ce-MRI), electrophysiological study (EPS), and left-ventricular endocardial high-density mapping were performed 15 days post-MI. Animals were randomized 1:1 to AGTP or sham-surgery group and monitored with ECG-Holter. Repeat EPS, endocardial mapping, and ce-MRI were performed 30 days post-intervention. Myocardial SERCA2, Connexin-43 (Cx43), Ryanodine receptor-2 (RyR2), and cardiac troponin-I (cTnI) gene and protein expression were evaluated. Results: The AGTP group showed a significant reduction of the total infarct scar, border zone and dense scar mass by ce-MRI (p = 0.04), and a decreased total scar and border zone area in bipolar voltage mapping (p < 0.001). AGTP treatment significantly reduced the area of very-slow conduction velocity (<0.2 m/s) (p = 0.002), the number of deceleration zones (p = 0.029), and the area of fractionated electrograms (p = 0.005). No differences were detected in number of induced or spontaneous ventricular arrhythmias at EPS and Holter-monitoring. SERCA2, Cx43, and RyR2 gene expression were decreased in the infarct core of AGTP-treated animals (p = 0.021, p = 0.018, p = 0.051, respectively). Conclusion: AGTP is a safe reparative therapy in terms of arrhythmic risk and provides additional protective effect against adverse electrophysiological remodeling in ischemic heart disease.

11.
Am J Cardiol ; 182: 1-7, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36075756

RESUMEN

Although complete bioresorbable vascular scaffold (BVS) resorption has been demonstrated at 5-year follow-up, whether corresponding vasomotor function restoration occurs remains unknown. The objective was to simultaneously assess the structural healing response along with vasomotor responses at 5-year follow-up of BVS implantation. We studied consecutive patients treated with ABSORB-BVS at 5-year follow-up (n = 31), who were recruited from a multicenter registry and were contacted to undergo a research protocol-driven repeat coronary angiogram involving intracoronary optical coherence tomography (OCT) and invasive coronary endothelial function testing. Epicardial endothelium-dependent vasomotion was defined as any vasodilatation after intracoronary acetylcholine (ACh), whereas endothelium-independent vasomotion was defined as any vasodilatation after intracoronary nitroglycerine (NTG), using quantitative coronary angiography. The mean implantation time point was 60.5 ± 4.6 months. OCT imaging demonstrated complete scaffold resorption in all patients. New coronary lesions (stenosis >50%) were found in 5 patients (16.1%), 3 of them underwent ad hoc percutaneous revascularization (9.7%). Intracoronary ACh (27 patients) and NTG testing (30 patients) was performed. Quantitative coronary angiography analysis demonstrated vasoconstriction after ACh administration and lack of response to NTG in BVS segments (mean lumen diameter = 2.00 ± 0.61 mm at baseline vs 1.74 ± 0.70 mm post-ACh, p <0.001; 2.05 ± 0.54 mm at baseline vs 2.03 ± 0.50 mm post-NTG, p = 0.69). OCT lumen analysis demonstrated similar vasoconstrictive responses to ACh (mean lumen area = 5.31 ± 2.26 mm2 at baseline vs 5.12 ± 2.55 mm2 post-ACh, p = 0.007) but had a vasodilatory response to NTG (5.96 ± 2.35 mm2 at baseline vs 6.17 ± 2.55 mm2 post-NTG, p<0.001). In conclusion, complete ABSORB-BVS resorption was demonstrated at 5-year follow-up. However, this healing response was associated with endothelium-dependent vasomotor dysfunction within the BVS segment.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Acetilcolina , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Vasos Coronarios/cirugía , Everolimus , Estudios de Seguimiento , Humanos , Nitroglicerina/farmacología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Tomografía de Coherencia Óptica , Resultado del Tratamiento
13.
Am J Cardiol ; 168: 55-63, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35058053

RESUMEN

We systematically categorized the longer-term (≥3 years) structural and functional characteristics of the ABSORB bioresorbable vascular scaffold (BVS) using optical coherence tomography imaging and coronary vasomotor reactivity testing and further compared the functional characteristics of BVS stented versus remote coronary segments. A total of 92 patients (mean age 56.4 ± 9.7 years, 22.8% women) who underwent percutaneous coronary intervention (76% with acute coronary syndrome) using the ABSORB BVS (112 lesions) were included. Optical coherence tomography analysis (38,790 visible struts) comprised in-segment quantitative lumen/plaque and semiquantitative plaque composition analysis of the neointimal pattern. Epicardial endothelium-dependent and-independent vasomotion was defined as any vasodilatation at low/intermediate intracoronary dose of acetylcholine (ACh) and nitroglycerine, assessed using quantitative coronary angiography. At a median time of 3.2 years follow-up, 79.8% of BVS segments still demonstrated visible struts with a predominant neointimal fibrotic healing pattern in 84% of BVS segments, with 99.5% of struts demonstrating coverage with apposition. Compared with remote segments, BVS segments demonstrated less endothelium-dependent vasodilatation at low (p = 0.06) and intermediate ACh doses (p = 0.04). Hypertension, longer time interval from index percutaneous coronary intervention, and the degree of in-BVS segment neointimal volume (p <0.03 for all) were each independently associated with abnormal BVS endothelium-dependent vasomotor function. Endothelium-independent function was more likely preserved in non-BVS (remote) segments compared with BVS segments (p = 0.06). In conclusion, at 3+ years post-ABSORB BVS insertion, the rate of complete scaffold resorption was low and residual strut presence was high, with a dominant fibrous healing response contributing toward neointimal hyperplasia and endothelium-dependent and-independent vasomotor dysfunction.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Anciano , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Vasos Coronarios/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neointima/patología , Diseño de Prótesis , Tomografía de Coherencia Óptica , Resultado del Tratamiento
14.
Sci Rep ; 12(1): 298, 2022 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-34996973

RESUMEN

Inappropriate sinus tachycardia (IST) is a common observation in patients with post-COVID-19 syndrome (PCS) but has not yet been fully described to date. To investigate the prevalence and the mechanisms underlying IST in a prospective population of PCS patients. Consecutive patients admitted to the PCS Unit between June and December 2020 with a resting sinus rhythm rate ≥ 100 bpm were prospectively enrolled in this study and further examined by an orthostatic test, 2D echocardiography, 24-h ECG monitoring (heart rate variability was a surrogate for cardiac autonomic activity), quality-of-life and exercise capacity testing, and blood sampling. To assess cardiac autonomic function, a 2:1:1 comparative sub-analysis was conducted against both fully recovered patients with previous SARS-CoV-2 infection and individuals without prior SARS-CoV-2 infection. Among 200 PCS patients, 40 (20%) fulfilled the diagnostic criteria for IST (average age of 40.1 ± 10 years, 85% women, 83% mild COVID-19). No underlying structural heart disease, pro-inflammatory state, myocyte injury, or hypoxia were identified. IST was accompanied by a decrease in most heart rate variability parameters, especially those related to cardiovagal tone: pNN50 (cases 3.2 ± 3 vs. recovered 10.5 ± 8 vs. non-infected 17.3 ± 10; p < 0.001) and HF band (246 ± 179 vs. 463 ± 295 vs. 1048 ± 570, respectively; p < 0.001). IST is prevalent condition among PCS patients. Cardiac autonomic nervous system imbalance with decreased parasympathetic activity may explain this phenomenon.


Asunto(s)
COVID-19/complicaciones , Taquicardia Sinusal/etiología , Adulto , COVID-19/diagnóstico , COVID-19/patología , COVID-19/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Prevalencia , Estudios Prospectivos , SARS-CoV-2/aislamiento & purificación , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/patología , Taquicardia Sinusal/fisiopatología , Síndrome Post Agudo de COVID-19
15.
Heart Rhythm O2 ; 3(6Part A): 656-664, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36589911

RESUMEN

Background: Atrial fibrillation (AF) ablation strategy is associated with a non-negligible risk of complications and often requires repeat procedures (AF ablation track), implying repetitive exposure to procedural risk. Objective: The purpose of this study was to develop and validate a model to estimate individualized cumulative risk of complications in patients undergoing the AF ablation track (Atrial Fibrillation TRAck Complication risK [AF-TRACK] calculator). Methods: The model was derived from a multicenter cohort including 3762 AF ablation procedures in 2943 patients. A first regression model was fitted to predict the propensity for repeat ablation. The AF-TRACK calculator computed the risk of AF ablation track complications, considering the propensity for repeat ablation. Internal (cross-validation) and external (independent cohort) validation were assessed for discrimination capacity (area under the curve [AUC]) and goodness of fit (Hosmer-Lemeshow [HL] test). Results: Complications (N = 111) occurred in 3.7% of patients (2.9% of procedures). Predictors included female sex, heart failure, sleep apnea syndrome, and repeat procedures. The model showed fair discrimination capacity to predict complications (AUC 0.61 [0.55-0.67]) and likelihood of repeat procedure (AUC 0.62 [0.60-0.64]), with good calibration (HL χ2 12.5; P = .13). The model maintained adequate discrimination capacity (AUC 0.67 [0.57-0.77]) and calibration (HL χ2 5.6; P = .23) in the external validation cohort. The validated model was used to create the Web-based AF-TRACK calculator. Conclusion: The proposed risk model provides individualized estimates of the cumulative risk of complications of undergoing the AF ablation track. The AF-TRACK calculator is a validated, easy-to-use, Web-based clinical tool to calibrate the risk-to-benefit ratio of this treatment strategy.

16.
J Vis Exp ; (177)2021 11 04.
Artículo en Inglés | MEDLINE | ID: mdl-34806712

RESUMEN

Myocardial infarction (MI) is the leading cause of mortality worldwide. Despite the use of evidence-based treatments, including coronary revascularization and cardiovascular drugs, a significant proportion of patients develop pathological left-ventricular remodeling and progressive heart failure following MI. Therefore, new therapeutic options, such as cellular and gene therapies, among others, have been developed to repair and regenerate injured myocardium. In this context, animal models of MI are crucial in exploring the safety and efficacy of these experimental therapies before clinical translation. Large animal models such as swine are preferred over smaller ones due to the high similarity of swine and human hearts in terms of coronary artery anatomy, cardiac kinetics, and the post-MI healing process. Here, we aimed to describe an MI model in pig by permanent coil deployment. Briefly, it comprises a percutaneous selective coronary artery cannulation through retrograde femoral access. Following coronary angiography, the coil is deployed at the target branch under fluoroscopic guidance. Finally, complete occlusion is confirmed by repeated coronary angiography. This approach is feasible, highly reproducible, and emulates the pathogenesis of human non-revascularized MI, avoiding the traditional open-chest surgery and the subsequent postoperative inflammation. Depending on the time of follow-up, the technique is suitable for acute, sub-acute, or chronic MI models.


Asunto(s)
Infarto del Miocardio , Animales , Modelos Animales de Enfermedad , Corazón , Humanos , Infarto del Miocardio/etiología , Infarto del Miocardio/patología , Infarto del Miocardio/terapia , Miocardio/patología , Porcinos , Remodelación Ventricular
17.
JACC Case Rep ; 3(1): 150-155, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34317491

RESUMEN

Up to one-third of patients who undergo cardiac resynchronization therapy do not obtain clinical benefit. A systematic approach can identify treatable causes in many nonresponding patients. We present a case of nonresponse to cardiac resynchronization therapy that resolved by ablation of the atrioventricular node in a patient with complete atrioventricular block. (Level of Difficulty: Advanced.).

18.
Am J Cardiol ; 138: 46-52, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33058803

RESUMEN

Obstructive sleep apnea-hypopnea syndrome (OSA) compromises the efficacy of atrial fibrillation (AF) control strategies. Continuous positive airway pressure (CPAP) may ameliorate arrhythmia control especially in early AF stages (new-onset AF). We investigated a practical screening strategy to determine the likelihood of CPAP indication in new-onset AF patients. Seventy-seven consecutive patients with new-onset (<1 month) AF were prospectively evaluated. Of them, 4 were excluded due to previously diagnosed OSA. The remaining 73 (68% persistent AF) fulfilled the Epworth, Berlin and STOP-BANG questionnaires, an ambulatory polysomnography being performed thereafter in all them in order to determine the apnea-hipopnea index (AHI). CPAP was indicated following conventional criteria. The variables associated with the diagnosis of OSA, with the AHI value and with CPAP indication were investigated by means of descriptive, univariate and multivariate analysis. The prevalence of OSA of any degree and CPAP indication was 82% and 37%, respectively. The variables associated (p < 0.05) with a higher AHI were male gender, body mass index, obesity, hypertension, and high-risk scoring at the Berlin and STOP-BANG questionnaires. In the multivariate analysis, the STOP-BANG scoring proved superior to conventional risk factors and became the only variable predicting CPAP indication (odds ratio 4.5 [1.9 to 10.6]; p = 0.01), an optimized cutoff value of ≥4 being newly established (sensitivity/specificity 76/65%). In conclusion, in patients referred with new-onset AF we documented a high risk of OSA and of need for CPAP. A STOP-BANG scoring of ≥4 in our population was a practical screening alternative to direct polysomnography in this setting.


Asunto(s)
Fibrilación Atrial/terapia , Apnea Obstructiva del Sueño/diagnóstico , Enfermedades no Diagnosticadas/diagnóstico , Anciano , Fibrilación Atrial/epidemiología , Índice de Masa Corporal , Presión de las Vías Aéreas Positiva Contínua , Femenino , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Obesidad/epidemiología , Oportunidad Relativa , Polisomnografía , Prevalencia , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Factores Sexuales , Apnea Obstructiva del Sueño/epidemiología , Apnea Obstructiva del Sueño/terapia , Encuestas y Cuestionarios , Enfermedades no Diagnosticadas/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA