Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
ACS Nano ; 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39137319

RESUMEN

Optical continuous glucose monitoring (CGM) systems are emerging for personalized glucose management owing to their lower cost and prolonged durability compared to conventional electrochemical CGMs. Here, we report a computational CGM system, which integrates a biocompatible phosphorescence-based insertable biosensor and a custom-designed phosphorescence lifetime imager (PLI). This compact and cost-effective PLI is designed to capture phosphorescence lifetime images of an insertable sensor through the skin, where the lifetime of the emitted phosphorescence signal is modulated by the local concentration of glucose. Because this phosphorescence signal has a very long lifetime compared to tissue autofluorescence or excitation leakage processes, it completely bypasses these noise sources by measuring the sensor emission over several tens of microseconds after the excitation light is turned off. The lifetime images acquired through the skin are processed by neural network-based models for misalignment-tolerant inference of glucose levels, accurately revealing normal, low (hypoglycemia) and high (hyperglycemia) concentration ranges. Using a 1 mm thick skin phantom mimicking the optical properties of human skin, we performed in vitro testing of the PLI using glucose-spiked samples, yielding 88.8% inference accuracy, also showing resilience to random and unknown misalignments within a lateral distance of ∼4.7 mm with respect to the position of the insertable sensor underneath the skin phantom. Furthermore, the PLI accurately identified larger lateral misalignments beyond 5 mm, prompting user intervention for realignment. The misalignment-resilient glucose concentration inference capability of this compact and cost-effective PLI makes it an appealing wearable diagnostics tool for real-time tracking of glucose and other biomarkers.

2.
J Biomed Opt ; 29(5): 052918, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38282917

RESUMEN

Significance: Preterm birth is defined as a birth before 37 weeks of gestation and is one of the leading contributors to infant mortality rates globally. Premature birth can lead to life-long developmental impairment for the child. Unfortunately, there is a significant lack of tools to diagnose preterm birth risk, which limits patient care and the development of new therapies. Aim: To develop a speculum-free, portable preterm imaging system (PPRIM) for cervical imaging; testing of the PPRIM system to resolve polarization properties of birefringent samples; and testing of the PPRIM under an IRB on healthy, non-pregnant volunteers for visualization and polarization analysis of cervical images. Approach: The PPRIM can perform 4×3 Mueller-matrix imaging to characterize the remodeling of the uterine cervix during pregnancy. The PPRIM is built with a polarized imaging probe and a flexible insertable sheath made with a compatible flexible rubber-like material to maximize comfort and ease of use. Results: The PPRIM device is developed to meet specific design specifications as a speculum-free, portable, and comfortable imaging system with polarized imaging capabilities. This system comprises a main imaging component and a flexible silicone inserter. The inserter is designed to maximize comfort and usability for the patient. The PPRIM shows high-resolution imaging capabilities at the 20 mm working distance and 25 mm circular field of view. The PPRIM demonstrates the ability to resolve birefringent sample orientation and full field capture of a healthy, non-pregnant cervix. Conclusion: The development of the PPRIM aims to improve access to the standard of care for women's reproductive health using polarized Mueller-matrix imaging of the cervix and reduce infant and maternal mortality rates and better quality of life.


Asunto(s)
Nacimiento Prematuro , Embarazo , Lactante , Niño , Recién Nacido , Femenino , Humanos , Calidad de Vida , Cuello del Útero/diagnóstico por imagen
3.
Sci Rep ; 11(1): 2570, 2021 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-33510428

RESUMEN

Cardiovascular disease is one of the leading causes of death in the United States and obesity significantly increases the risk of cardiovascular disease. The measurement of blood pressure (BP) is critical in monitoring and managing cardiovascular disease hence new wearable devices are being developed to make BP more accessible to physicians and patients. Several wearables utilize photoplethysmography from the wrist vasculature to derive BP assessment although many of these devices are still at the experimental stage. With the ultimate goal of supporting instrument development, we have developed a model of the photoplethysmographic waveform derived from the radial artery at the volar surface of the wrist. To do so we have utilized the relation between vessel biomechanics through Finite Element Method and Monte Carlo light transport model. The model shows similar features to that seen in PPG waveform captured using an off the shelf device. We observe the influence of body mass index on the PPG signal. A degradation the PPG signal of up to 40% in AC to DC signal ratio was thus observed.


Asunto(s)
Fotopletismografía/métodos , Arteria Radial/fisiología , Animales , Fenómenos Biomecánicos , Presión Sanguínea/fisiología , Índice de Masa Corporal , Análisis de Elementos Finitos , Humanos , Método de Montecarlo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA