Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Europace ; 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39150065

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt EGM signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. STUDY AIM: If application repetition and catheter-tissue contact impact on lesion formation during PFA. METHODS: A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact-force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 hours in the vegetal model and over 6 hours in the porcine model. RESULTS: Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 mm and 4.4 ± 1.3 mm, respectively (p =0.002). Furthermore, the greater the catheter-tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0±0.9 mm with no contact Vs. 5.4±1.4 mm with 30 g of force; p=.0001). CONCLUSION: PFA delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA ablation are more related to PFA biophysics than mere EGM attenuation.

2.
Heart Rhythm ; 8(7): 968-74, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21376835

RESUMEN

BACKGROUND: Catheter ablation of ventricular arrhythmias (VAs) with cryoenergy has not been widely reported. OBJECTIVE: The purpose of this study was to assess the feasibility and safety of cryoablation for VA. METHODS: Cases where cryoablation of VA was attempted as the initial strategy or was considered to prevent potential damage to other structures such as the coronary arteries, phrenic nerve, and His bundle were collected. Thirty-three patients with either normal heart or structural heart disease undergoing VA ablation using cryoenergy at six different institutions were enrolled in the study. Epicardial access was obtained when appropriate. RESULTS: Fifteen patients (7 men) underwent endocardial ablation, 13 (9 men) epicardial ablation (from the coronary sinus in 7), and 5 (2 men) aortic cusp ablation. Mean age was 54 ± 8 years, and ejection fraction was 45% ± 5%. In 15 (45%) patients, VAs were successfully ablated, whereas cryoablation was unsuccessful in the remaining 18 (55%) patients. Cryoablation was successful in all parahisian cases (100%). In three patients, epicardial cryoablation was successful after several failed attempts with open irrigated catheter. An aortic dissection occurred during catheter placement in the aortic cusp. At follow-up of 24 ± 5 months, all patients with acute success were free from clinical VA. CONCLUSION: Use of cryoenergy for ablation of VA has excellent success for arrhythmias near the His bundle; however, success rates at other sites appear less favorable. Cryoablation may be considered as an alternative approach for reducing complications during ablation of VAs originating from sites close to other relevant cardiac structures (conduction system, coronary arteries, phrenic nerve) and, in rare cases, could be used epicardially when radiofrequency energy applications have failed.


Asunto(s)
Criocirugía/métodos , Sistema de Conducción Cardíaco/cirugía , Taquicardia Ventricular/cirugía , Mapeo del Potencial de Superficie Corporal , Ecocardiografía/métodos , Endosonografía , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA