Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Radiol Med ; 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-39405018

RESUMEN

PURPOSE: To evaluate the diagnostic accuracy of dual-energy CT (DECT) iodine maps in comparison to conventional CT series for the assessment of non-occlusive mesenteric ischemia (NOMI). MATERIAL AND METHODS: We evaluated data from 142 patients (72 men; 50.7%) who underwent DECT between 2018 and 2022, with surgically confirmed diagnosis of NOMI. One board-certified radiologist performed region of interest (ROI) measurements in bowel segments on late arterial (LA) and portal venous (PV) phase DECT iodine maps as well as LA conventional series, in both ischemic and non-ischemic bowel loops, using surgical reports as reference standard, and in a control group of 97 patients. Intra- and inter-reader agreement with a second board-certified radiologist was also evaluated. Receiver operating characteristic (ROC) curve analysis was performed to calculate the optimal threshold for discriminating ischemic from non-ischemic bowel segments. Subjective image rating of LA and PV iodine maps was performed. RESULTS: DECT-based iodine concentration (IC) measurements showed significant differences in LA phase iodine maps between ischemic (median:0.72; IQR 0.52-0.91 mg/mL) and non-ischemic bowel loops (5.16; IQR 3.45-6.31 mg/ml) (P <.0001). IC quantification on LA phase revealed an AUC of 0.966 for the assessment of acute bowel ischemia, significantly higher compared to both IC quantification based on PV phase (0.951) and attenuation values evaluated on LA conventional CT series (0.828). Excellent intra-observer and strong inter-observer agreements were observed for the quantification of iodine concentration. Conversely, weak inter-observer agreement was noted for conventional HU assessments. The optimal LA phase-based IC threshold for assessing bowel ischemia was 1.34 mg/mL, yielding a sensitivity of 100% and specificity of 96.48%. CONCLUSION: Iodine maps based on LA phase significantly improve the diagnostic accuracy for the assessment of NOMI compared to conventional CT series and PV phase iodine maps.

2.
Medicina (Kaunas) ; 60(10)2024 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-39459373

RESUMEN

Background and Objectives: This study aimed to evaluate the tumor response relating to and survival benefit of transarterial chemoperfusion (TACP) and transarterial chemoembolization (TACE) in the treatment of patients with unresectable gynecologic tumors who are intolerant of or have a suboptimal response to chemotherapy and radiotherapy. Materials and Methods: Between January 2000 and October 2023, 75 patients diagnosed with gynecologic tumors underwent 213 TACP and 154 TACE procedures. Of these, 33 patients were treated with TACP, 20 were treated with TACE, and 22 received a combination of both therapies. A retrospective evaluation of local tumor response according to Response Evaluation Criteria in Solid Tumors (RECIST) was conducted, and survival rates were determined using the Kaplan-Meier estimator. Results: Of the total 75 patients, 50 (67%) maintained a stable course of disease until the completion of therapy, 10 (13%) had a partial response, 2 (3%) had a complete response following thermal ablation, and 13 (17%) experienced progression. Furthermore, a 6% reduction in the sum of the longest diameters and an 8% reduction in tumor volume were observed. The median overall survival was 16.15 months, while the median progression-free survival was 13.19 months. Conclusions: TACP and TACE are potential treatment options for local tumor control in patients with unresectable gynecologic tumors who are intolerant of or show a poor response to chemotherapy and radiotherapy. However, further investigation and adjustment of treatment protocols are required to improve therapy response and survival outcomes.


Asunto(s)
Quimioembolización Terapéutica , Neoplasias de los Genitales Femeninos , Humanos , Femenino , Quimioembolización Terapéutica/métodos , Quimioembolización Terapéutica/estadística & datos numéricos , Neoplasias de los Genitales Femeninos/terapia , Neoplasias de los Genitales Femeninos/mortalidad , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Adulto , Resultado del Tratamiento , Anciano de 80 o más Años , Estimación de Kaplan-Meier
3.
Radiol Med ; 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39287697

RESUMEN

PURPOSE: Preliminary dual-energy CT studies have shown that low-energy virtual monoenergetic (VMI) + reconstructions can provide superior image quality compared to standard 120 kV CTA series. The purpose of this study is to evaluate the impact of low-energy VMI reconstructions on quantitative and qualitative image quality, vascular contrast, and diagnostic assessability of the carotid artery in patients undergoing photon-counting CTA examinations. MATERIALS AND METHODS: A total of 122 patients (67 male) who had undergone dual-source photon-counting CTA scans of the carotid artery were retrospectively analyzed in this study. Standard 120 kV CT images and low-keV VMI series from 40 to 100 keV with an interval of 15 keV were reconstructed. Quantitative analyses included the evaluation of vascular CT numbers, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). CT number measurements were performed in the common, external, and internal carotid arteries. Qualitative analyses were performed by three board-certified radiologists independently using five-point scales to evaluate image quality, vascular contrast, and diagnostic assessability of the carotid artery. RESULTS: Mean attenuation, CNR and SNR values were highest in 40 keV VMI reconstructions (HU, 1362.32 ± 457.81; CNR, 33.19 ± 12.86; SNR, 34.37 ± 12.89) followed by 55-keV VMI reconstructions (HU, 736.94 ± 150.09; CNR, 24.49 ± 7.11; SNR, 26.25 ± 7.34); all three mean values at these keV levels were significantly higher compared with the remaining VMI series and standard 120 kV CT series (HU, 154.43 ± 23.69; CNR, 16.34 ± 5.47; SNR, 24.44 ± 7.14) (p < 0.0001). The qualitative analysis showed the highest rating scores for 55 keV VMI reconstructions followed by 40 keV and 70 keV VMI series with a significant difference compared to standard 120 kV CT images series regarding image quality, vascular contrast, and diagnostic assessability of the carotid artery (all comparisons, p < 0.01). CONCLUSIONS: Low-keV VMI reconstructions at a level of 40-55 keV significantly improve image quality, vascular contrast, and the diagnostic assessability of the carotid artery compared with standard CT series in photon-counting CTA.

4.
Radiol Med ; 129(10): 1499-1506, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39123064

RESUMEN

PURPOSE: To evaluate a deep learning-based pipeline using a Dense-UNet architecture for the assessment of acute intracranial hemorrhage (ICH) on non-contrast computed tomography (NCCT) head scans after traumatic brain injury (TBI). MATERIALS AND METHODS: This retrospective study was conducted using a prototype algorithm that evaluated 502 NCCT head scans with ICH in context of TBI. Four board-certified radiologists evaluated in consensus the CT scans to establish the standard of reference for hemorrhage presence and type of ICH. Consequently, all CT scans were independently analyzed by the algorithm and a board-certified radiologist to assess the presence and type of ICH. Additionally, the time to diagnosis was measured for both methods. RESULTS: A total of 405/502 patients presented ICH classified in the following types: intraparenchymal (n = 172); intraventricular (n = 26); subarachnoid (n = 163); subdural (n = 178); and epidural (n = 15). The algorithm showed high diagnostic accuracy (91.24%) for the assessment of ICH with a sensitivity of 90.37% and specificity of 94.85%. To distinguish the different ICH types, the algorithm had a sensitivity of 93.47% and a specificity of 99.79%, with an accuracy of 98.54%. To detect midline shift, the algorithm had a sensitivity of 100%. In terms of processing time, the algorithm was significantly faster compared to the radiologist's time to first diagnosis (15.37 ± 1.85 vs 277 ± 14 s, p < 0.001). CONCLUSION: A novel deep learning algorithm can provide high diagnostic accuracy for the identification and classification of ICH from unenhanced CT scans, combined with short processing times. This has the potential to assist and improve radiologists' ICH assessment in NCCT scans, especially in emergency scenarios, when time efficiency is needed.


Asunto(s)
Aprendizaje Profundo , Hemorragias Intracraneales , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Masculino , Femenino , Tomografía Computarizada por Rayos X/métodos , Persona de Mediana Edad , Hemorragias Intracraneales/diagnóstico por imagen , Adulto , Anciano , Algoritmos , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Sensibilidad y Especificidad , Factores de Tiempo , Anciano de 80 o más Años
5.
J Magn Reson Imaging ; 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39165139

RESUMEN

BACKGROUND: Magnetic resonance elastography (MRE) can quantify tissue biomechanics noninvasively, including pathological hepatic states like metabolic dysfunction-associated steatohepatitis. PURPOSE: To compare the performance of 2D/3D-MRE using the gravitational (GT) transducer concept with the current commercial acoustic (AC) solution utilizing a 2D-MRE approach. Additionally, quality index markers (QIs) were proposed to identify image pixels with sufficient quality for reliably estimating tissue biomechanics. STUDY TYPE: Prospective. POPULATION: One hundred seventy participants with suspected or confirmed liver disease (median age, 57 years [interquartile range (IQR), 46-65]; 66 females), and 11 healthy volunteers (median age, 31 years [IQR, 27-34]; 5 females). FIELD STRENGTH/SEQUENCE: Participants were scanned twice at 1.5 T and 60 Hz vibration frequency: first, using AC-MRE (2D-MRE, spin-echo EPI sequence, 11 seconds breath-hold), and second, using GT-MRE (2D- and 3D-MRE, gradient-echo sequence, 14 seconds breath-hold). ASSESSMENT: Image analysis was performed by four independent radiologists and one biomedical engineer. Additionally, superimposed analytic plane shear waves of known wavelength and attenuation at fixed shear modulus were used to propose pertinent QIs. STATISTICAL TESTS: Spearman's correlation coefficient (r) was applied to assess the correlation between modalities. Interreader reproducibility was evaluated using Bland-Altman bias and reproducibility coefficients. P-values <0.05 were considered statistically significant. RESULTS: Liver stiffness quantified via GT-2D/3D correlated well with AC-2D (r ≥ 0.89 [95% CI: 0.85-0.92]) and histopathological grading (r ≥ 0.84 [95% CI: 0.72-0.91]), demonstrating excellent agreement in Bland-Altman plots and between readers (κ ≥ 0.86 [95% CI: 0.81-0.91]). However, GT-2D showed a bias in overestimating stiffness compared to GT-3D. Proposed QIs enabled the identification of pixels deviating beyond 10% from true stiffness based on a combination of total wave amplitude, temporal sinusoidal nonlinearity, and wave signal-to-noise ratio for GT-3D. CONCLUSION: GT-MRE represents an alternative to AC-MRE for noninvasive liver tissue characterization. Both GT-2D and 3D approaches correlated strongly with the established commercial approach, offering advanced capabilities in abdominal imaging compared to AC-MRE. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

6.
Diagnostics (Basel) ; 14(15)2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39125552

RESUMEN

This study uses magnetic resonance imaging (MRI) to investigate the potential of the hepatospecific contrast agent gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) in distinguishing G1- from G2/G3-differentiated hepatocellular carcinoma (HCC). Our approach involved analyzing the dynamic behavior of the contrast agent in different phases of imaging by signal intensity (SI) and lesion contrast (C), to surrounding liver parenchyma, and comparing it across distinct groups of patients differentiated based on the histopathological grading of their HCC lesions and the presence of liver cirrhosis. Our results highlighted a significant contrast between well- and poorly-differentiated lesions regarding the lesion contrast in the arterial and late arterial phases. Furthermore, the hepatobiliary phase showed limited diagnostic value in cirrhotic liver parenchyma due to altered pharmacokinetics. Ultimately, our findings underscore the potential of Gd-EOB-DTPA-enhanced MRI as a tool for improving preoperative diagnosis and treatment selection for HCC while emphasizing the need for continued research to overcome the diagnostic complexities posed by the disease.

7.
Acad Radiol ; 31(11): 4519-4527, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38862346

RESUMEN

RATIONALE AND OBJECTIVES: This retrospective study evaluates the efficacy and safety of Prostatic Artery Embolization (PAE) for the treatment of benign prostatic hyperplasia (BPH) over five years at a single center, conducted by an experienced interventional radiologist. MATERIALS AND METHODS: We analyzed 551 PAE interventions from January 2019 to July 2023. Key metrics included patient demographics, procedural details (radiation exposure, particle size), complication rates, pre- and post-interventional prostatic volume (PV), Prostate-specific Antigen (PSA) levels, International Prostate Symptom Score (IPSS), Quality of Life (QoL) scores and International Index of Erectile Function (IIEF) scores. We assessed data normality, performed group and paired sample comparisons, and evaluated correlations. RESULTS: For 551 men, the average patient age was 68.81 ± 8.61 years undergoing bilateral embolization. The particle size predominantly used was 100-300 µm (n = 441). PAE lead to significant (p < .001) reduction of both PV (-9.67 ± 14.52 mL) and PSA level (-2,65 ± 1.56 ng/mL) between pre- and three months after PAE. Substantial improvement were observed for IPSS (-9 points) and QoL scores (-2 points), with stable IIEF scores. Only minor complications (n = 16) were reported, and no major complications were observed. Between the first PAE in 2019 and the routinely performed PAE in 2023 significant (p < .0001) reductions in fluoroscopy (-25.2%), and procedural times (-26.1%) were observed. CONCLUSION: In conclusion, PAE is a safe and effective treatment for BPH, offering significant improvements in lower urinary tract symptoms (LUTS) and QoL while maintaining sexual function.


Asunto(s)
Embolización Terapéutica , Próstata , Hiperplasia Prostática , Calidad de Vida , Humanos , Masculino , Embolización Terapéutica/métodos , Hiperplasia Prostática/terapia , Hiperplasia Prostática/diagnóstico por imagen , Anciano , Próstata/irrigación sanguínea , Próstata/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento , Persona de Mediana Edad , Antígeno Prostático Específico/sangre
8.
Diagnostics (Basel) ; 14(7)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38611654

RESUMEN

OBJECTIVES: The aim of this study is to evaluate the diagnostic accuracy of dual-energy computed tomography (DECT)-based Rho/Z maps in differentiating between metastases and benign liver lesions in patients diagnosed with malignant melanoma compared to conventional CT value measurements. METHODS: This retrospective study included 73 patients (mean age, 70 ± 13 years; 43 m/30 w) suffering from malignant melanoma who had undergone third-generation DECT as part of tumor staging between December 2017 and December 2021. For this study, we measured Rho (electron density) and Z (effective atomic number) values as well as Hounsfield units (HUs) in hypodense liver lesions. Values were compared, and diagnostic accuracy for differentiation was computed using receiver operating characteristic (ROC) curve analyses. Additional performed MRI or biopsies served as a standard of reference. RESULTS: A total of 136 lesions (51 metastases, 71 cysts, and 14 hemangiomas) in contrast-enhanced DECT images were evaluated. The most notable discrepancy (p < 0.001) between measured values and the highest diagnostic accuracy for distinguishing melanoma metastases from benign cysts was observed for the Z (0.992; 95% CI, 0.956-1) parameters, followed by Rho (0.908; 95% CI, 0.842-0.953) and finally HU120kV (0.829; 95% CI, 0.751-0.891). Conversely, when discriminating between liver metastases and hemangiomas, the HU120kV parameters showed the most significant difference (p < 0.001) and yielded the highest values for diagnostic accuracy (0.859; 95% CI, 0.740-0.937), followed by the Z parameters (0.790; 95% CI, 0.681-0.876) and finally the Rho values (0.621; 95% CI, 0.501-0.730). CONCLUSIONS: Rho and Z measurements derived from DECT allow for improved differentiation of liver metastases and benign liver cysts in patients with malignant melanoma compared to conventional CT value measurements. In contrast, in differentiation between liver hemangiomas and metastases, Rho/Z maps show inferior diagnostic accuracy. Therefore, differentiation between these two lesions remains a challenge for CT imaging.

9.
Eur J Radiol ; 170: 111235, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38071908

RESUMEN

BACKGROUND: This study aimed to evaluate the clinical utility of modern single and dual-energy computed tomography (CT) for assessing the integrity of the cruciate ligaments in patients that sustained acute trauma. METHODS: Patients who underwent single- or dual-energy CT followed by 3 Tesla magnetic resonance imaging (MRI) or knee joint arthroscopy between 01/2016 and 12/2022 were included in this retrospective, monocentric study. Three radiologists specialized in musculoskeletal imaging independently evaluated all CT images for the presence of injury to the cruciate ligaments. An MRI consensus reading of two experienced readers and arthroscopy provided the reference standard. Diagnostic accuracy parameters and area under the receiver operator characteristic curve (AUC) were the primary metrics for diagnostic performance. RESULTS: CT images of 204 patients (median age, 49 years; IQR 36 - 64; 113 males) were evaluated. Dual-energy CT yielded significantly higher diagnostic accuracy and AUC for the detection of injury to the anterior (94% [240/255] vs 75% [266/357] and 0.89 vs 0.66) and posterior cruciate ligaments (95% [243/255] vs 87% [311/357] and 0.90 vs 0.61) compared to single-energy CT (all parameters, p <.005). Diagnostic confidence and image quality were significantly higher in dual-energy CT compared to single-energy CT (all parameters, p <.005). CONCLUSIONS: Modern dual-energy CT is readily available and can serve as a screening tool for detecting or excluding cruciate ligament injuries in patients with acute trauma. Accurate diagnosis of cruciate ligament injuries is crucial to prevent adverse outcomes, including delayed treatment, chronic instability, or long-term functional limitations.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Traumatismos de la Rodilla , Ligamento Cruzado Posterior , Masculino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Traumatismos de la Rodilla/patología , Sensibilidad y Especificidad , Articulación de la Rodilla/patología , Ligamento Cruzado Posterior/lesiones , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/patología , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos
10.
Eur J Clin Invest ; 53(10): e14060, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37409393

RESUMEN

BACKGROUND: Cancer is a well-known risk factor for venous thromboembolism (VTE). A combined strategy of D-dimer testing and clinical pre-test probability is usually used to exclude VTE. However, its effectiveness is diminished in cancer patients due to reduced specificity, ultimately leading to a decreased clinical utility. This review article seeks to provide a comprehensive summary of how to interpret D-dimer testing in cancer patients. METHODS: In accordance with PRISMA standards, literature pertaining to the diagnostic and prognostic significance of D-dimer testing in cancer patients was carefully chosen from reputable sources such as PubMed and the Cochrane databases. RESULTS: D-dimers have not only a diagnostic value in ruling out VTE but can also serve as an aid for rule-in if their values exceed 10-times the upper limit of normal. This threshold allows a diagnosis of VTE in cancer patients with a positive predictive value of more than 80%. Moreover, elevated D-dimers carry important prognostic information and are associated with VTE reoccurrence. A gradual increase in risk for all-cause death suggests that VTE is also an indicator of biologically more aggressive cancer types and advanced cancer stages. Considering the lack of standardization for D-dimer assays, it is essential for clinicians to carefully consider the variations in assay performance and the specific test characteristics of their institution. CONCLUSIONS: Standardizing D-dimer assays and developing modified pretest probability models specifically for cancer patients, along with adjusted cut-off values for D-dimer testing, could significantly enhance the accuracy and effectiveness of VTE diagnosis in this population.


Asunto(s)
Productos de Degradación de Fibrina-Fibrinógeno , Neoplasias , Humanos , Neoplasias/sangre , Neoplasias/complicaciones , Neoplasias/diagnóstico , Valor Predictivo de las Pruebas , Factores de Riesgo , Tromboembolia Venosa/sangre , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/prevención & control , Bioensayo/normas , Sensibilidad y Especificidad
11.
Diagnostics (Basel) ; 13(12)2023 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-37371011

RESUMEN

This article describes the technical principles and clinical applications of dual-energy computed tomography (DECT) in the context of cardiothoracic imaging with a focus on current developments and techniques. Since the introduction of DECT, different vendors developed distinct hard and software approaches for generating multi-energy datasets and multiple DECT applications that were developed and clinically investigated for different fields of interest. Benefits for various clinical settings, such as oncology, trauma and emergency radiology, as well as musculoskeletal and cardiovascular imaging, were recently reported in the literature. State-of-the-art applications, such as virtual monoenergetic imaging (VMI), material decomposition, perfused blood volume imaging, virtual non-contrast imaging (VNC), plaque removal, and virtual non-calcium (VNCa) imaging, can significantly improve cardiothoracic CT image workflows and have a high potential for improvement of diagnostic accuracy and patient safety.

12.
Cancer Imaging ; 23(1): 38, 2023 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-37072856

RESUMEN

BACKGROUND: The advent of next-generation computed tomography (CT)- and magnetic resonance imaging (MRI) opened many new perspectives in the evaluation of tumor characteristics. An increasing body of evidence suggests the incorporation of quantitative imaging biomarkers into clinical decision-making to provide mineable tissue information. The present study sought to evaluate the diagnostic and predictive value of a multiparametric approach involving radiomics texture analysis, dual-energy CT-derived iodine concentration (DECT-IC), and diffusion-weighted MRI (DWI) in participants with histologically proven pancreatic cancer. METHODS: In this study, a total of 143 participants (63 years ± 13, 48 females) who underwent third-generation dual-source DECT and DWI between November 2014 and October 2022 were included. Among these, 83 received a final diagnosis of pancreatic cancer, 20 had pancreatitis, and 40 had no evidence of pancreatic pathologies. Data comparisons were performed using chi-square statistic tests, one-way ANOVA, or two-tailed Student's t-test. For the assessment of the association of texture features with overall survival, receiver operating characteristics analysis and Cox regression tests were used. RESULTS: Malignant pancreatic tissue differed significantly from normal or inflamed tissue regarding radiomics features (overall P < .001, respectively) and iodine uptake (overall P < .001, respectively). The performance for the distinction of malignant from normal or inflamed pancreatic tissue ranged between an AUC of ≥ 0.995 (95% CI, 0.955-1.0; P < .001) for radiomics features, ≥ 0.852 (95% CI, 0.767-0.914; P < .001) for DECT-IC, and ≥ 0.690 (95% CI, 0.587-0.780; P = .01) for DWI, respectively. During a follow-up of 14 ± 12 months (range, 10-44 months), the multiparametric approach showed a moderate prognostic power to predict all-cause mortality (c-index = 0.778 [95% CI, 0.697-0.864], P = .01). CONCLUSIONS: Our reported multiparametric approach allowed for accurate discrimination of pancreatic cancer and revealed great potential to provide independent prognostic information on all-cause mortality.


Asunto(s)
Yodo , Neoplasias Pancreáticas , Femenino , Humanos , Imagen por Resonancia Magnética , Pronóstico , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Estudios Retrospectivos
13.
Eur Radiol ; 33(9): 6339-6350, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37000215

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the diagnostic accuracy of third-generation dual-source dual-energy CT (DECT) color-coded collagen reconstructions for the assessment of the cruciate ligaments compared to standard grayscale image reconstruction. METHODS: Patients who underwent third-generation dual-source DECT followed by either 3-T MRI or arthroscopy of the knee joint within 14 days between January 2016 and December 2021 were included in this retrospective study. Five radiologists independently evaluated conventional grayscale DECT for the presence of injury to the cruciate ligaments; after 4 weeks, readers re-evaluated the examinations using grayscale images and color-coded collagen reconstructions. A reference standard for MRI was provided by a consensus reading of two experienced readers and arthroscopy. Sensitivity and specificity were the primary metrics of diagnostic performance. RESULTS: Eighty-five patients (mean age, 44 years ± 16; 50 male) with injury to the ACL or PCL (n = 31) were ultimately included. Color-coded collagen reconstructions significantly increased overall sensitivity (94/105 [90%] vs. 67/105 [64%]), specificity (248/320 [78%] vs. 215/320 [67%]), PPV (94/166 [57%] vs. 67/162 [39%]), NPV (248/259 [96%] vs. 215/253 [85%]), and accuracy (342/425 [81%] vs. 282/425 [66%]) for the detection of injury to the anterior cruciate ligament (all parameters, p < .001). For injury to the posterior cruciate ligament, diagnostic accuracy increased for complete tears (p < .001). Color-coded collagen reconstructions achieved superior diagnostic confidence, image quality, and noise scores compared to grayscale CT (all parameters, p < .001) and showed good agreement with MRI examinations. CONCLUSIONS: DECT-derived color-coded collagen reconstructions yield substantially higher diagnostic accuracy and confidence for assessing the integrity of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. KEY POINTS: • Color-coded collagen reconstructions derived from dual-energy CT yield substantially higher diagnostic accuracy and confidence for the assessment of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. • Color-coded collagen reconstructions demonstrate good agreement with MRI for the assessment cruciate ligament injury. • Dual-energy CT may serve as a readily available screening approach for patients with acute trauma to the knee when injury to the cruciate ligaments is suspected.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Tomografía Computarizada por Rayos X , Humanos , Masculino , Adulto , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Articulación de la Rodilla , Ligamento Cruzado Anterior , Colágeno , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Sensibilidad y Especificidad , Imagen por Resonancia Magnética/métodos
14.
Diagnostics (Basel) ; 13(4)2023 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-36832249

RESUMEN

Due to its high morbidity and mortality, myocardial infarction is the leading cause of death worldwide. Against this background, rapid diagnosis is of immense importance. Especially in case of an atypical course, the correct diagnosis may be delayed and thus lead to increased mortality rates. In this report, we present a complex case of acute coronary syndrome. A triple-rule-out CT examination was performed in dual-energy CT (DECT) mode. While pulmonary artery embolism and aortic dissection could be ruled out with conventional CT series, the presence of anterior wall infarction was only detectable on DECT reconstructions. Subsequently, adequate and rapid therapy was then initiated leading to survival of the patient.

15.
Diagnostics (Basel) ; 13(3)2023 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-36766647

RESUMEN

Urine sedimentation in the bladder can occur in various circumstances and can lead to urinary obstruction/stasis with associated pain. It is usually diagnosed with an ultrasound; however, CT is also used to assess the amount and to further check for urinary stones. Depending on the composition, urine sedimentation and stones can be treated medically by alkalinisation of the urine with potassium sodium hydrogen citrate in the case of uric acid-based sedimentation/stones. Due to technical developments and improved material differentiation and characterisation in CT imaging, dual-energy CT allows for differentiation of uric acid from calcium, which can be used for sedimentation/stone composition analysis. Subsequently, treatment decisions can be made based on the findings in dual-energy CT.

17.
Acad Radiol ; 30(10): 2110-2117, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36577605

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate the bone mineral density (BMD) of the lumbar spine derived from dual-energy CT (DECT)-based volumetric material decomposition and its association with acute insufficiency fractures of the thoracolumbar spine. MATERIALS AND METHODS: L1 of 160 patients (77 men, 83 women; mean age 64.3 years, range, 22-94 years) who underwent third-generation dual-source DECT between January 2016 and December 2021 due to suspected insufficiency fractures was retrospectively analyzed. All depicted vertebrae were examined for signs of recent fractures. A dedicated DECT postprocessing software using material decomposition was applied for phantomless BMD assessment. Receiver-operating characteristic (ROC) analysis identified optimal BMD thresholds. Associations of BMD, sex, and age with the occurrence of insufficiency fractures were examined with logistic regression models. RESULTS: A DECT-derived BMD threshold of 120.40 mg/cm³ yielded 90.1% specificity and 59.32% sensitivity to differentiate patients with at least one insufficiency fracture from patients without fracture. No patient without fracture had a DECT-derived BMD below 85 mg/cm3. Lower DECT-derived bone mineral density was associated with an increased risk of insufficiency fractures (Odds ratio of 0.93, 95% CI, 0.91-0.96, p < 0.001). Overall ROC-derived AUC was 0.82 (p < 0.0001) for the differentiation of patients that sustained an insufficiency fracture from the control group. CONCLUSION: Dual-Energy CT-based BMD assessment can accurately differentiate patients with acute insufficiency fractures of the thoracolumbar spine from patients without fracture. This algorithm can be used for phantomless risk stratification of patients undergoing routine CT to sustain insufficiency fractures of the thoracolumbar spine The identified cut-off value of 120.4 mg/cm³ is in line with current American College of Radiology (ACR) recommendations to differentiate healthy individuals from those with reduced bone mineral density.


Asunto(s)
Fracturas por Estrés , Osteoporosis , Fracturas de la Columna Vertebral , Masculino , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Densidad Ósea , Estudios Retrospectivos , Prevalencia , Absorciometría de Fotón , Tomografía Computarizada por Rayos X , Vértebras Lumbares/diagnóstico por imagen , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/epidemiología
18.
Eur J Clin Invest ; 53(4): e13914, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36444723

RESUMEN

BACKGROUND: D-dimer testing is known to have a high sensitivity at simultaneously low specificity, resulting in nonspecific elevations in a variety of conditions. METHODS: This retrospective study sought to assess diagnostic and prognostic features of D-dimers in cancer patients referred to the emergency department for suspected pulmonary embolism (PE) and deep vein thrombosis (DVT). In total, 526 patients with a final adjudicated diagnosis of PE (n = 83) and DVT (n = 69) were enrolled, whereas 374 patients served as the comparative group, in which venous thromboembolism (VTE) has been excluded. RESULTS: For the identification of VTE, D-dimers yielded the highest positive predictive value of 96% (95% confidence interval (CI), 85-99) at concentrations of 9.9 mg/L and a negative predictive value of 100% at .6 mg/L (95% CI, 97-100). At the established rule-out cut-off level of .5 mg/L, D-dimers were found to be very sensitive (100%) at a moderate specificity of nearly 65%. Using an optimised cut-off value of 4.9 mg/L increased the specificity to 95% for the detection of life-threatening VTE at the cost of moderate sensitivities (64%). During a median follow-up of 30 months, D-dimers positively correlated with the reoccurrence of VTE (p = .0299) and mortality in both cancer patients with VTE (p < .0001) and without VTE (p = .0008). CONCLUSIONS: Although D-dimer testing in cancer patients is discouraged by current guidelines, very high concentrations above the 10-fold upper reference limit contain diagnostic and prognostic information and might be helpful in risk assessment, while low concentrations remain useful for ruling out VTE.


Asunto(s)
Neoplasias , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/diagnóstico , Pronóstico , Estudios Retrospectivos , Productos de Degradación de Fibrina-Fibrinógeno , Valor Predictivo de las Pruebas
19.
Fundam Clin Pharmacol ; 37(3): 519-529, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36509694

RESUMEN

Upcoming experimental and epidemiological data have identified the endogenous non-proteinogenic amino acid L-homoarginine (L-hArg) not only as a novel biomarker for cardiovascular disease but also as being directly involved in the pathogenesis of cardiac dysfunction. The association of low L-hArg levels with adverse cardiovascular events and mortality has proposed the idea of nutritional supplementation to rescue pathways inversely associated with cardiovascular health. Subsequent clinical and experimental studies contributed significantly to our knowledge of potential effects on the cardiorenal axis, acting either as a biomarker or a cardiovascular active agent. In this review article, we provide a comprehensive summary of the L-hArg metabolism, pathophysiological aspects, and current developments in the field of experimental and clinical evidence in favor of protective cardiovascular effects. Establishing a reliable biomarker to identify patients at high risk to die of cardiovascular disease represents one of the main goals for tackling this disease and providing individual therapeutic guidance.


Asunto(s)
Enfermedades Cardiovasculares , Sistema Cardiovascular , Humanos , Homoarginina , Enfermedades Cardiovasculares/diagnóstico , Arginina/metabolismo , Biomarcadores
20.
Acad Radiol ; 30(4): 689-697, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35688786

RESUMEN

RATIONALE AND OBJECTIVES: In previous clinical studies digital variance angiography (DVA) provided higher contrast-to-noise ratio (CNR) and better image quality in lower extremity angiography than digital subtraction angiography (DSA). Our aim was to investigate whether DVA has similar quality reserve in prostatic artery embolization (PAE). The secondary aim was to explore the potential advantages of the color-coded DVA (ccDVA) technology in PAE. MATERIAL AND METHODS: This retrospective study evaluated 108 angiographic acquisitions from 30 patients (mean ± SD age 68.0 ± 8.9, range 41-87) undergoing PAE between May and October 2020. DSA and DVA images were generated from the same unsubtracted acquisition, and their CNR was calculated. Visual evaluation of DVA and DSA image quality was performed by four experienced interventional radiologists in a randomized, blinded manner. The diagnostic value of DSA and ccDVA images was also evaluated using clinically relevant criteria (visibility of small [< 2.5 mm] and large arteries [> 2.5 mm], feeding arteries and tissue blush) in a paired comparison. Data were analysed by the Wilcoxon signed rank test or the binomial test, the interrater agreement was determined by the Kendall W or Fleiss Kappa analysis. RESULTS: DVA provided 4.11 times higher median CNR than DSA (IQR: 1.72). The visual score of DVA images (4.40 ± 0.05) was significantly higher than that of DSA (3.39 ± 0.07, p < 0.001). The Kendall W analysis showed moderate but significant agreement (WDVA = 0.38, WDSA = 0.53). The preference of ccDVA images was significantly higher in all criteria (63-89%) with an interrater agreement of 58-79%. The Fleiss Kappa range was 0.02-0.18, significant in all criteria except large vessels. CONCLUSION: Our data show that DVA provides higher CNR and better image quality in PAE. This quality reserve might be used for dose management (reduction of radiation dose and contrast agent volume), and ccDVA technology has also a high potential to assist PAE interventions in the future.


Asunto(s)
Embolización Terapéutica , Hiperplasia Prostática , Anciano , Humanos , Masculino , Persona de Mediana Edad , Angiografía de Substracción Digital/métodos , Arterias , Próstata/diagnóstico por imagen , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA