Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 212: 111440, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39018816

RESUMEN

The sensitivity to ionizing radiation is increasing by age of development for some malignant tumors. Therefore, children have higher risk to radiation induced tumors due the high cellular rate of proliferation and long lifespan probability. The risk is also increase with increase the effective and organ doses. Computed tomography (CT) exposed pediatric patients to higher radiation dose during multiphase image acquisition, repeated exams, for follow-up procedures. This research intended to estimate the radiogenic risks and effective radiation doses resulted from CT enhanced contrast for abdomen and pelvis. 126 (66 (62.3%) males, 60 (47.7%) females) pediatric patients underwent CT enhanced abdominal examination at Medical Imaging Department at King Khalid Hospital and Prince Sultan Center for Health Services, Alkharj, Saudi Arabia. The average and range of pediatric age (years) is 11.6 ± 5.0 (0.1-17). The mean, standard deviation, and range of the volume CT air kerma index (CVOL (mGy) and the air kerma length product (PKL, mGy.cm) were 9.8 ± 9.4 (2.1-45.8) and 1795 (221-3150) per abdominopelvic procedure, respectively. The mean and range of the effective dose (mSv) per procedure are 26.9 (2.4-59.1). The effective dose is higher compared to the most previously published studies. The effective dose per pediatric abdomen and pelvis with contrast procedure suggest that the patient dose is not optimized yet. Because the chest and pelvis region contain sensitive organs that are irradiated repeatedly, dose optimization is crucial.


Asunto(s)
Medios de Contraste , Neoplasias Inducidas por Radiación , Pelvis , Dosis de Radiación , Tomografía Computarizada por Rayos X , Humanos , Arabia Saudita , Niño , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Femenino , Preescolar , Masculino , Pelvis/diagnóstico por imagen , Adolescente , Lactante , Neoplasias Inducidas por Radiación/epidemiología , Neoplasias Inducidas por Radiación/etiología , Medios de Contraste/efectos adversos , Radiografía Abdominal/efectos adversos , Abdomen/diagnóstico por imagen , Abdomen/efectos de la radiación
2.
Heliyon ; 9(11): e22451, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38034673

RESUMEN

Assessment of activity levels of radionuclides that exist in soil, granite, and charnockite rock samples is very crucial because it exhibits an enhanced elemental concentration of uranium (U) and thorium (Th) contributing higher natural background activity than usual in the environment and it may cause health risk to human health through the external and internal exposure. This study determined the radioactivity levels of 238U, 232Th, and 40K radionuclides in soil, granite, and charnockite rock samples collected from selected fields in Ekiti State, Nigeria using Caesium iodide CsI(Tl) scintillation gamma spectrometer. It also evaluated indices of the radiological parameters consisting of radium equivalent activity (Raeq), absorbed dose rate (DR), annual effective dose equivalent (AEDE), internal hazard index (Hin), and excess lifetime cancer risk (ELCR). The calculated average activity concentrations of 238U, 232Th, and 40K are 30.40 ± 0.71 Bq kg-1, 3.31 ± 0.05 Bq kg-1, and 222.25 ± 14.72 Bq kg-1, respectively, which were lower than their respective world average values. Comparatively, potassium concentrations in these collected samples have a higher value than concentrations of uranium and thorium (40K > 238U > 232Th). All the evaluated values of the radiological parameters (except DR) of the appraised radionuclides were below the global permissible limits. The granite rocks, charnockite rocks, and soils from Ekiti State in Nigeria do not pose any hazardous risk to humans, but continued monitoring is necessary when these materials are used as building materials, which cause long-term radiation exposure.

3.
Front Pharmacol ; 14: 1218867, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37601050

RESUMEN

The field of cancer nanotheranostics is rapidly evolving, with cyclodextrin (CD)-based nanoparticles emerging as a promising tool. CDs, serving as nanocarriers, have higher adaptability and demonstrate immense potential in delivering powerful anti-cancer drugs, leading to promising and specific therapeutic outcomes for combating various types of cancer. The unique characteristics of CDs, combined with innovative nanocomplex creation techniques such as encapsulation, enable the development of potential theranostic treatments. The review here focuses mainly on the different techniques administered for effective nanotheranostics applications of CD-associated complex compounds in the domain of cancer treatments. The experimentations on various loaded drugs and their complex conjugates with CDs prove effective in in vivo results. Various cancers can have potential nanotheranostics cures using CDs as nanoparticles along with a highly efficient process of nanocomplex development and a drug delivery system. In conclusion, nanotheranostics holds immense potential for targeted drug delivery and improved therapeutic outcomes, offering a promising avenue for revolutionizing cancer treatments through continuous research and innovative approaches.

4.
Brain Sci ; 13(3)2023 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-36979267

RESUMEN

Numerous factors can contribute to the development of neurodegenerative disorders (NDs), such as Alzheimer's disease, Parkinson's disease, amyotrophic lateral sclerosis, Huntington's disease, and multiple sclerosis. Oxidative stress (OS), a fairly common ND symptom, can be caused by more reactive oxygen species being made. In addition, the pathological state of NDs, which includes a high number of protein aggregates, could make chronic inflammation worse by activating microglia. Carotenoids, often known as "CTs", are pigments that exist naturally and play a vital role in the prevention of several brain illnesses. CTs are organic pigments with major significance in ND prevention. More than 600 CTs have been discovered in nature, and they may be found in a wide variety of creatures. Different forms of CTs are responsible for the red, yellow, and orange pigments seen in many animals and plants. Because of their unique structure, CTs exhibit a wide range of bioactive effects, such as anti-inflammatory and antioxidant effects. The preventive effects of CTs have led researchers to find a strong correlation between CT levels in the body and the avoidance and treatment of several ailments, including NDs. To further understand the connection between OS, neuroinflammation, and NDs, a literature review has been compiled. In addition, we have focused on the anti-inflammatory and antioxidant properties of CTs for the treatment and management of NDs.

5.
J Clin Imaging Sci ; 10: 46, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32874751

RESUMEN

OBJECTIVES: This study aims to first measure patient doses during computed tomography (CT) chest, abdomen, and extremities procedures for evaluation lymphedema, and second to estimate the radiation dose-related risks during the procedures. MATERIAL AND METHODS: Radiation effective doses from CT lymphography procedures quantified using CT machines from different vendors. After the calibration of CT systems, the data collected for a total of 28 CT lymphography procedures. Effective and organ doses extrapolated using national radiological protection software based on Monte Carlo simulation. RESULTS: The mean patient doses for chest and abdomen procedures in term of CTDIvol (mGy) and DLP (mGy.cm) are 10.0 ± 3 and 425 ± 222 and 24 ± 12 and 1118 ± 812 for CT 128 and CT 16 slice, respectively. The mean DLP (mGy.cm) for extremities was 320 ± 140 and 424 ± 212 for CT 128 and CT 16 slice, in that order. CONCLUSION: Patients' dose showed significant differences due to variation in the scan length and clinical indication. Organs lay in the primary beam received high radiation doses especially in the chest region which increases the probability of radiation-induced cancer. The current patient's doses are higher compared to the previous studies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA