Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 284
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39128016

RESUMEN

OBJECTIVES: We investigated the sex-related difference in characteristics and 2-year outcomes after surgical aortic valve replacement (SAVR) by propensity-score matching (PSM). METHODS: Data from two prospective registries, INDURE and IMPACT, were merged, resulting in a total of 933 patients: 735 males and 253 females undergoing first-time SAVR. PSM was performed to assess the impact of sex on the SAVR outcomes, yielding 433 males and 243 females with comparable baseline characteristics. RESULTS: Females had a lower body mass index (BMI; median 27.1 vs 28.0 kg/m2; p = 0.008), fewer bicuspid valves (52% vs 59%; p = 0.036), higher EuroSCORE II (mean 2.3 vs 1.8%; p < 0.001) and STS score (mean 1.6 vs 0.9%; p < 0.001), were more often in NYHA class III/IV (47% vs 30%; p < 0.001) and angina CCS III/IV (8.2% vs 4.4%; p < 0.001), but had a lower rate of myocardial infarction (1.9% vs 5.2%; p = 0.028) compared to males. These differences vanished after PSM, except for EuroSCORE II and STS scores, which were still significantly higher in females. Furthermore, females required smaller valves (median diameter 23.0 vs 25.0 mm, p < 0.001). There were no differences in the length of hospital stay (median 8 days) or ICU stay (median 24 vs 25 hours) between both sexes. At two years, post-SAVR outcomes were comparable between males and females, even after PSM. CONCLUSIONS: Despite females presenting with a significantly higher surgical risk profile, 2-year outcomes following SAVR were comparable between males and females.

2.
Bioengineering (Basel) ; 11(7)2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-39061748

RESUMEN

Tricuspid regurgitation (TR) is a prevalent finding in echocardiography and in case of severe disease is associated with impaired patient outcome. Clover repair offers a surgical solution that can be applied for the treatment of primary and secondary TR. An ex vivo passive beating porcine heart model was created to test a modified clover technique using automated suturing devices and to compare this approach to standard ring annuloplasty. Secondary TR was induced in 10 porcine hearts and the backflow of fluid was assessed. The primary endpoint of this study was regurgitant volume measured in mL at the site right atrial cannula. The baseline regurgitation was 43.3 ± 10.8 mL. The mean regurgitant volume was significantly reduced after all repair procedures to 22.2 ± 5.9 mL with isolated ring annuloplasty, 12 ± 3.9 mL with the modified clover, and 7.6 ± 3.4 mL with the combined procedure (p < 0.0001). The modified clover technique shows how to effectively reduce TR in an ex vivo model. This method may be suitable to facilitate tricuspid repair, especially for totally endoscopic valve surgery.

3.
Medicina (Kaunas) ; 60(7)2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39064567

RESUMEN

(1) Background and Objectives: Mitral regurgitation is a common valve disease requiring surgical repair. Even with satisfactory results, repair techniques may underlie subjectivity and variability and require long learning curves. A novel approach, the "Roman Arch" technique, may ease the technical burden. This study assessed an automated suturing device's feasibility and time efficiency for a proposed simplified technique. (2) Materials and Methods: Using the MiStitch™ and MiKnot™ devices (LSI Solutions, Inc., Victor, NY, USA), the suture pattern was performed in a cadaver model. Three surgeons with different expertise levels conducted the procedures. Repair and suture placement times were recorded and analyzed. (3) Results: The modified "Roman Arch" repair was completed on all ten human heart specimens with an average total repair time of 3:01 ± 00:59 min and a trend toward reduced times as experience increased. The study confirmed the technical feasibility with 90% of the attempts rated as rather satisfactory or very satisfactory. (4) Conclusions: The MiStitch™ system effectively facilitated the modified "Roman Arch" repair in an ex vivo setting, suggesting its potential to reduce the technical complexity of mitral valve repairs. Further studies are needed to confirm its efficacy and safety in clinical practice.


Asunto(s)
Insuficiencia de la Válvula Mitral , Válvula Mitral , Técnicas de Sutura , Humanos , Técnicas de Sutura/instrumentación , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Cadáver , Estudios de Factibilidad
4.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38913864

RESUMEN

OBJECTIVES: Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain. METHODS: A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed. RESULTS: The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20-0.94, P = 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60-1.09, P = 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63-1.07, P = 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47-1.45, P = 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P = 0.032). CONCLUSIONS: Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis.


Asunto(s)
Válvula Aórtica , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Técnicas de Sutura , Titanio , Humanos , Masculino , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Anciano , Válvula Aórtica/cirugía , Endocarditis/prevención & control , Técnicas de Sutura/instrumentación , Estudios Retrospectivos , Persona de Mediana Edad , Prótesis Valvulares Cardíacas/efectos adversos
5.
J Clin Med ; 13(11)2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38892924

RESUMEN

Objectives: Mitral valve repair is the current standard approach for mitral valve regurgitation. However, patients suffering from functional mitral regurgitation have a significant risk of recurrent regurgitation. Adjustable mitral rings may provide a solution for this adverse event. Methods: A single-center, first-in-man clinical study was performed on patients suffering from mitral valve regurgitation. Patients were implanted with the study ring and followed for six months. A balloon catheter can be inserted into the study ring frame at any time after implantation and inflated independently in the areas P1, P2, or P3, which reduces the anterior-posterior diameter. Results: Five patients (75.4 ± 6.1 years; EuroSCORE II 2.1 ± 0.9%; three female) were successfully implanted. Mechanisms of mitral regurgitation were prolapse of the P2-segment in three patients and annular dilation in two patients. Surgical implantation according to the protocol was feasible and is described herein. Median cardiopulmonary bypass time and cross clamp time were 105 (118; 195) and 94 (90; 151) min, respectively. The median intensive care unit stay was 2 (2; 3) days. No perioperative, 30-day, or 6-month mortality was observed, and the repair was stable without residual or recurrent regurgitation ≥ grade 2. All patients reached the primary endpoint without device-related morbidity. Conclusions: Successful implantation was completed in five patients without device-related adverse events. Ring implantation was safe and feasible for all patients. The opportunity of post-implant adjustment to improve leaflet coaptation is a promising new therapeutic strategy that is assessed in a phase II study.

6.
Orthopadie (Heidelb) ; 53(7): 503-510, 2024 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-38829400

RESUMEN

The various connective tissues of the body have different functions, which result from their specific structure and composition. The identification of this structure-function relationship is of great importance for various disciplines such as medicine, biology or tissue engineering. Connective tissue consists mainly of an extracellular matrix (ECM) and a limited number of cells. It is extremely adaptable because the activity of the cells remodels the composition and structure of the ECM in order to adapt the mechanical properties (functions) to the new demands (e.g. an increased mechanical stimulus).


Asunto(s)
Tejido Conectivo , Matriz Extracelular , Tejido Conectivo/fisiología , Humanos , Matriz Extracelular/fisiología , Matriz Extracelular/química , Fenómenos Biomecánicos/fisiología , Modelos Biológicos , Animales , Ingeniería de Tejidos/métodos
7.
Clin Chim Acta ; 561: 119815, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38879062

RESUMEN

BACKGROUND: Postoperative atrial fibrillation (POAF) represents the most common complication following cardiac surgery. Approximately one-third of patients experiencing POAF transition to atrial fibrillation within a year, challenging the notion of POAF as merely a transient event. Soluble ST2 (sST2) is an established biomarker regarding fibrosis and myocardial stretch, however, its role in predicting the onset of POAF remains unclear. METHODS: Preoperative sST2 levels have been assessed in 496 individuals with no prior history of AF who underwent elective cardiac surgery, including valve, coronary artery bypass graft surgery, or a combined procedure. RESULTS: The average age was 70 years, and 29.4 % were female. Overall, 42.3 % developed POAF. sST2 levels were found to be significantly higher in patients with POAF. Interestingly, sST2 was only predictive of POAF in females with an adjusted OR of 1.894 (95 %CI:1.103-3.253; p = 0.021) and not males (OR:1.091; 95 %CI:0.849-1.402; p = 0.495). Furthermore, within a linear regression model it was observed that for every 1 ng/mL increase in sST2 levels, the average POAF duration extended by 39.5 min (95 %CI:15.8-63.4 min; p = 0.001). CONCLUSION: sST2 predicts the onset of POAF in women but not men undergoing cardiac surgery. Furthermore, sST2 levels were associated with the subsequent burden of POAF. Thus, assessment of sST2 in addition to clinical risk factors could improve risk stratification for development of POAF following elective cardiac surgery.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Proteína 1 Similar al Receptor de Interleucina-1 , Posmenopausia , Complicaciones Posoperatorias , Humanos , Fibrilación Atrial/etiología , Proteína 1 Similar al Receptor de Interleucina-1/sangre , Femenino , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Masculino , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/sangre , Persona de Mediana Edad , Biomarcadores/sangre , Solubilidad
9.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38749619

RESUMEN

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
10.
J Clin Med ; 13(9)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38731227

RESUMEN

Background: Transcatheter aortic valve replacement (TAVR) has evolved as first-line therapy for severe aortic valve stenosis (AS), with pre-procedural computed tomography (CT) providing critical anatomical information. While primarily used for anatomical planning, TAVR-CT also offers an opportunity to assess low bone mineral density (BMD), a known indicator of frailty. Despite this, the prognostic role of BMD in TAVR patients remains unknown. This study aimed to evaluate BMD on routine TAVR-CT and its impact on long-term survival. Methods: In this retrospective study, 770 consecutive TAVR patients (mean age 80.7 ± 6.7 years, 54.0% males) between November 2015 and March 2022 were included. BMD was measured from a single axial image at the thoracic vertebral level on unenhanced CT scans. Cox regression models assessed the impact of BMD on mortality, and Restricted Cubic Spline models identified potential mortality thresholds. Results: The mean BMD value, as measured on non-contrast CT, was 147.5 ± 5.4 Hounsfield units, demonstrating a noteworthy association with mortality (adjusted hazard ratio per 100 HU decrease: 1.27 [95%CI: 1.01-1.59], p = 0.041). Restricted cubic spline analysis indicated that BMD below 200 HU was linked to a substantial increase in mortality risk. Upon crude Cox regression analysis, every 100 HU decrease was associated with a 32% increase in risk for death (HR 1.32 [95%CI: 1.068-1.65)], p = 0.010). Conclusions: In conclusion, low BMD on TAVR-CT is independently associated with reduced survival, suggesting its potential as a tool for comprehensive frailty assessment and improved risk prediction in TAVR patients.

11.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599688

RESUMEN

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Estudios Multicéntricos como Asunto , Sistema de Registros
12.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38532304

RESUMEN

OBJECTIVES: Decellularized aortic homografts (DAH) were introduced as a new option for aortic valve replacement for young patients. METHODS: A prospective, EU-funded, single-arm, multicentre study in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement. RESULTS: A total of 144 patients (99 male) were prospectively enrolled in the ARISE Trial between October 2015 and October 2018 with a median age of 30.4 years [interquartile range (IQR) 15.9-55.1]; 45% had undergone previous cardiac operations, with 19% having 2 or more previous procedures. The mean implanted DAH diameter was 22.6 mm (standard deviation 2.4). The median operation duration was 312 min (IQR 234-417), the median cardiopulmonary bypass time was 154 min (IQR 118-212) and the median cross-clamp time 121 min (IQR 93-150). No postoperative bypass grafting or renal replacement therapy were required. Two early deaths occurred, 1 due to a LCA thrombus on day 3 and 1 due ventricular arrhythmia 5 h postoperation. There were 3 late deaths, 1 death due to endocarditis 4 months postoperatively and 2 unrelated deaths after 5 and 7 years due to cancer and Morbus Wegener resulting in a total mortality of 3.47%. After a median follow-up of 5.9 years [IQR 5.1-6.4, mean 5.5 years. (standard deviation 1.3) max. 7.6 years], the primary efficacy end-points peak gradient with median 11.0 mmHg (IQR 7.8-17.6) and regurgitation of median 0.5 (IQR 0-0.5) of grade 0-3 were excellent. At 5 years, freedom from death/reoperation/endocarditis/bleeding/thromboembolism were 97.9%/93.5%/96.4%/99.2%/99.3%, respectively. CONCLUSIONS: The 5-year results of the prospective multicentre ARISE trial continue to show DAH to be safe for aortic valve replacement with excellent haemodynamics.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Humanos , Masculino , Aloinjertos/cirugía , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Endocarditis/cirugía , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Reoperación , Datos de Salud Recolectados Rutinariamente , Femenino , Adolescente , Adulto Joven , Persona de Mediana Edad
13.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38437953

RESUMEN

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Asunto(s)
Cateterismo Cardíaco , Sistema de Registros , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Anciano , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad , Ecocardiografía/métodos
14.
J Clin Med ; 13(6)2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38541839

RESUMEN

Background: Repeat sacrocolpopexy (reSCP) for recurrent pelvic organ prolapse (POP) is a rare and complex condition with little understanding of how to manage. Most authors recommend complete reSCP regardless of the underlying cause of the failure. This retrospective cohort study presents our management workflow and how to systematically approach this challenging situation. Methods: From 2017 to 2021, we analyzed all women undergoing surgery for recurrent POP after sacrocolpopexy at our tertiary referral hospital at the department of urogynecology. Preoperatively, all women underwent a structured work-up consisting of answering the validated German female pelvic floor questionnaires, a clinical examination utilizing the POP-Q staging system according to the International Continence Society (ICS), and a pelvic floor ultrasound. The surgical management was based on the preoperative findings and was adapted individually during surgery if indicated according to the estimated underlying problem for recurrence. Results: In total, 377 women underwent a primary laparoscopic sacrocolpopexy. However, ten women presented with a symptomatic recurrent prolapse requiring further surgical intervention. A reSCP was performed in eight women, including two with additional laparoscopic paravaginal repair to correct the displaced mesh placement at initial surgery. A vaginal correction was indicated in two women with an isolated posterior compartment prolapse. The analysis demonstrates that reSCP has a low intraoperative complication rate and high subjective and objective success rates. Conclusions: We could demonstrate that individualized reSCP after initial SCP is a challenging yet feasible and safe treatment option, but there may be suitable alternatives. If women undergo pre- and intraoperative standardized problem-oriented examinations, we can often identify the cause of the recurrent prolapse. Tailored surgery must be subsequently performed.

15.
Am Heart J ; 270: 86-94, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38309610

RESUMEN

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Válvula Aórtica/cirugía , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Puente de Arteria Coronaria , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
16.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38385922

RESUMEN

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/métodos , Sistema de Registros
17.
Front Cardiovasc Med ; 11: 1363336, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38322769

RESUMEN

Objectives: To date, there is no evidence regarding the safety of automated titanium fastener compared with hand-tied knots for prosthesis fixation in infective endocarditis. Methods: Between January 2016 and December 2022, a total of 220 patients requiring surgery for infective endocarditis were included in this retrospective analysis. The primary study endpoint was re-endocarditis during follow-up. The secondary study endpoints included stroke onset, all-cause mortality, and a composite outcome of either re-endocarditis, stroke, or all-cause mortality during follow-up. Results: Suture-securing with an automated titanium fastener was performed in 114 (51.8%) patients, whereas the conventional technique of hand knot-tying was used in 106 (48.2%) patients. The risk of re-endocarditis was significantly lower in the automated titanium fastener group, as shown in a multivariable proportional competing risk regression model (adjusted sub-hazard ratio 0.33, 95% confidence interval 0.11-0.99, p = 0.048). The multivariable Cox proportional hazards regression analysis showed that the automated titanium fastener group was not associated with an increased risk of stroke-onset or attaining the composite outcome, respectively, (adjusted hazard ratio 0.54, 95% confidence interval 0.27-1.08, p = 0.082), (adjusted hazard ratio 0.65, 95% confidence interval 0.42-1.02, p = 0.061). Also, this group was not associated with an increased risk of all-cause mortality, as demonstrated in the multivariable Poisson regression analysis (adjusted incidence-rate ratio 1.42, 95% confidence interval 0.83-2.42, p = 0.202). Conclusions: The use of automated titanium fastener device seems to be safe for infective endocarditis. Analyses of larger cohorts are required.

18.
Mhealth ; 10: 8, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38323143

RESUMEN

Background: This systematic review aims to highlight the untapped potential of heart rate variability (HRV) and atrial fibrillation (AF) monitoring by wearable health monitoring devices as a critical diagnostic tool in cardiac surgery (CS) patients. We reviewed established predictive capabilities of HRV and AF monitoring in specific cardiosurgical scenarios and provide a perspective on additional predictive properties of wearable health monitoring devices that need to be investigated. Methods: After screening most relevant databases, we included 33 publications in this review. Perusing these publications on HRV's prognostic value, we could identify HRV as a predictor for sudden cardiac death, mortality after acute myocardial infarction (AMI), and post operative atrial fibrillation (POAF). With regards to standard AF assessment, which typically includes extensive periods of unrecorded cardiac activity, we demonstrated that continuous monitoring via wearables recorded significant cardiac events that would otherwise have been missed. Results: Photoplethysmography and single-lead electrocardiogram (ECG) were identified as the most useful and convenient technical assessment modalities, and their advantages and disadvantages were described in detail. As a call to further action, we observed that the scientific community has relatively extensively explored wearable AF screening, whereas HRV assessment to improve relevant clinical outcomes in CS is rarely studied; it still has great potential to be leveraged. Conclusions: Therefore, risk assessment in CS would benefit greatly from earlier preoperative and postoperative AF detection, comprehensive and accurate assessment of cardiac health through HRV metrics, and continuous long-term monitoring. These should be achievable via commercially available wearables.

19.
Am Heart J ; 269: 158-166, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38163616

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI. METHODS: The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life. CONCLUSIONS: The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Simulación por Computador , Calidad de Vida , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X/efectos adversos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos
20.
Viruses ; 16(1)2024 01 14.
Artículo en Inglés | MEDLINE | ID: mdl-38257821

RESUMEN

Microvascular integrity is a critical factor in myocardial fluid homeostasis. The subtle equilibrium between capillary filtration and lymphatic fluid removal is disturbed during pathological processes leading to inflammation, but also in hypoxia or due to alterations in vascular perfusion and coagulability. The degradation of the glycocalyx as the main component of the endothelial filtration barrier as well as pericyte disintegration results in the accumulation of interstitial and intracellular water. Moreover, lymphatic dysfunction evokes an increase in metabolic waste products, cytokines and inflammatory cells in the interstitial space contributing to myocardial oedema formation. This leads to myocardial stiffness and impaired contractility, eventually resulting in cardiomyocyte apoptosis, myocardial remodelling and fibrosis. The following article reviews pathophysiological inflammatory processes leading to myocardial oedema including myocarditis, ischaemia-reperfusion injury and viral infections with a special focus on the pathomechanisms evoked by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. In addition, clinical implications including potential long-term effects due to viral persistence (long COVID), as well as treatment options, are discussed.


Asunto(s)
COVID-19 , Virosis , Humanos , COVID-19/complicaciones , Síndrome Post Agudo de COVID-19 , SARS-CoV-2 , Progresión de la Enfermedad , Edema
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA