Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
2.
J Fr Ophtalmol ; 46(10): 1212-1221, 2023 Dec.
Artículo en Francés | MEDLINE | ID: mdl-37867123

RESUMEN

BACKGROUND/PURPOSE: To evaluate long-term visual outcomes of Boston type I keratoprosthesis (KPro) surgery and identify risk factors for visual failure. METHODS: Single surgeon retrospective cohort study including 85 eyes of 74 patients who underwent KPro implantation to treat severe ocular surface disease, including limbal stem cell deficiency, postinfectious keratitis, aniridia and chemical burns. Procedures were performed at the Centre hospitalier de l'Université de Montréal from October 2008 to May 2012. All patients with at least 5 years of follow-up were included in the analysis, including eyes with repeated KPro. Main outcome measures were visual acuity (VA), visual failure, defined as a sustained VA worse than the preoperative VA, postoperative complications, and device retention. RESULTS: Mean follow-up was 7.2±1.3 years (±SD). Mean VA was 2.1±0.7 (logarithm of minimal angle resolution) preoperatively and 1.9±1.2 at last follow-up. In total, 2.4% of patients had VA better than 20/200 preoperatively vs. 36.5% at last follow-up. Maintenance of improved postoperative VA was seen in 61.8% of eyes at 7 years. Preoperative factors associated with visual failure were known history of glaucoma (HR=2.7 [1.2 to 5.9], P=0.02) and Stevens-Johnson syndrome (HR=7.3 [2.5 to 21.4], P<0.01). Cumulative 8-year complication rates were 38.8% retroprosthetic membrane formation, 25.9% hypotony, 23.5% new onset glaucoma, 17.6% retinal detachment, 8.2% device extrusion and 5.9% endophthalmitis. The majority (91.8%) of eyes retained the device 8 years after implantation. CONCLUSION: Nearly two-thirds of patients exhibited improved VA 7 years after KPro implantation. Preoperative risk factors for visual failure were known glaucoma and Stevens-Johnson syndrome.


Asunto(s)
Órganos Artificiales , Enfermedades de la Córnea , Glaucoma , Síndrome de Stevens-Johnson , Humanos , Córnea/cirugía , Prótesis e Implantes/efectos adversos , Enfermedades de la Córnea/epidemiología , Enfermedades de la Córnea/cirugía , Enfermedades de la Córnea/complicaciones , Estudios Retrospectivos , Síndrome de Stevens-Johnson/complicaciones , Órganos Artificiales/efectos adversos , Canadá , Glaucoma/epidemiología , Glaucoma/etiología , Glaucoma/cirugía , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Estudios de Seguimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA