1.
BMJ Open ; 14(6): e083752, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38871661

RESUMEN

INTRODUCTION: Clinical assessment in emergency departments (EDs) for possible acute myocardial infarction (AMI) requires at least one cardiac troponin (cTn) blood test. The turn-around time from blood draw to posting results in the clinical portal for central laboratory analysers is ~1-2 hours. New generation, high-sensitivity, point-of-care cardiac troponin I (POC-cTnI) assays use whole blood on a bedside (or near bedside) analyser that provides a rapid (8 min) result. This may expedite clinical decision-making and reduce length of stay. Our purpose is to determine if utilisation of a POC-cTnI testing reduces ED length of stay. We also aim to establish an optimised implementation process for the amended clinical pathway. METHODS AND ANALYSIS: This quality improvement initiative has a pragmatic multihospital stepped-wedge cross-sectional cluster randomised design. Consecutive patients presenting to the ED with symptoms suggestive of possible AMI and having a cTn test will be included. Clusters (comprising one or two hospitals each) will change from their usual-care pathway to an amended pathway using POC-cTnI-the 'intervention'. The dates of change will be randomised. Changes occur at 1 month intervals, with a minimum 2 month 'run-in' period. The intervention pathway will use a POC-cTnI measurement as an alternate to the laboratory-based cTn measurement. Clinical decision-making steps and logic will otherwise remain unchanged. The POC-cTnI is the Siemens (Erlangen Germany) Atellica VTLi high-sensitivity cTnI assay. The primary outcome is ED length of stay. The safety outcome is cardiac death or AMI within 30 days for patients discharged directly from the ED. ETHICS AND DISSEMINATION: Ethics approval has been granted by the New Zealand Southern Health and Disability Ethics Committee, reference 21/STH/9. Results will be published in a peer-reviewed journal. Lay and academic presentations will be made. Maori-specific results will be disseminated to Maori stakeholders. TRIAL REGISTRATION NUMBER: ACTRN12619001189112.


Asunto(s)
Síndrome Coronario Agudo , Servicio de Urgencia en Hospital , Mejoramiento de la Calidad , Humanos , Síndrome Coronario Agudo/sangre , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Biomarcadores/sangre , Toma de Decisiones Clínicas , Estudios Transversales , Tiempo de Internación/estadística & datos numéricos , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Medición de Riesgo , Troponina I/sangre
2.
Eur Heart J ; 45(28): 2508-2515, 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-38842324

RESUMEN

BACKGROUND AND AIMS: Strategies to assess patients with suspected acute myocardial infarction (AMI) using a point-of-care (POC) high-sensitivity cardiac troponin I (hs-cTnI) assay may expedite emergency care. A 2-h POC hs-cTnI strategy for emergency patients with suspected AMI was derived and validated. METHODS: In two international, multi-centre, prospective, observational studies of adult emergency patients (1486 derivation cohort and 1796 validation cohort) with suspected AMI, hs-cTnI (Siemens Atellica® VTLi) was measured at admission and 2 h later. Adjudicated final diagnoses utilized the hs-cTn assay in clinical use. A risk stratification algorithm was derived and validated. The primary diagnostic outcome was index AMI (Types 1 and 2). The primary safety outcome was 30-day major adverse cardiac events incorporating AMI and cardiac death. RESULTS: Overall, 81 (5.5%) and 88 (4.9%) patients in the derivation and validation cohorts, respectively, had AMI. The 2-h algorithm defined 66.1% as low risk with a sensitivity of 98.8% [95% confidence interval (CI) 89.3%-99.9%] and a negative predictive value of 99.9 (95% CI 99.2%-100%) for index AMI in the derivation cohort. In the validation cohort, 53.3% were low risk with a sensitivity of 98.9% (95% CI 92.4%-99.8%) and a negative predictive value of 99.9% (95% CI 99.3%-100%) for index AMI. The high-risk metrics identified 5.4% of patients with a specificity of 98.5% (95% CI 96.6%-99.4%) and a positive predictive value of 74.5% (95% CI 62.7%-83.6%) for index AMI. CONCLUSIONS: A 2-h algorithm using a POC hs-cTnI concentration enables safe and efficient risk assessment of patients with suspected AMI. The short turnaround time of POC testing may support significant efficiencies in the management of the large proportion of emergency patients with suspected AMI.


Asunto(s)
Algoritmos , Infarto del Miocardio , Troponina I , Humanos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/sangre , Masculino , Femenino , Estudios Prospectivos , Troponina I/sangre , Anciano , Persona de Mediana Edad , Sistemas de Atención de Punto , Biomarcadores/sangre , Medición de Riesgo/métodos , Sensibilidad y Especificidad , Pruebas en el Punto de Atención
3.
Clin Chem Lab Med ; 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38801528

RESUMEN

OBJECTIVES: This study performed an analytical validation study of the Mindray high-sensitivity cardiac troponin I (hs-cTnI) assay addressing limit of blank (LoB), limit of detection (LoD), precision, linearity, analytical specificity and sex-specific 99th percentile upper reference limits. METHODS: LoB, LoD, precision, linearity and analytical specificity were studied according to Clinical and Laboratory Standards Institute. We used one reagent lot and one CL1200i analyzer. Skeletal troponin I and T, cardiac troponin T, troponin C, actin, tropomyosin, myosin light chain, myoglobin and creatine kinase (CK-MB) were studied for cross-reactivity. Interference with biotin was examined. Lithium heparin samples (one freeze thaw cycle) from healthy males and females were measured to determine the 99th percentiles by using the non-parametric method. Analyses were performed before and after excluding subjects with clinical conditions and/or increased surrogate biomarkers. RESULTS: The Mindray hs-cTnI assay met criteria to be considered as a hs-cTn assay. LoB and LoD was <0.1 ng/L and 0.1 ng/L, respectively. Repeatability had a coefficient of variation 1.2-3.8 %, and within-laboratory imprecision 1.7-5.0 %. The measuring interval ranged from 1.1 to 28,180 ng/L. The analytical specificity was clinically acceptable for the interferents studied. After exclusions, the 99th percentile URLs obtained were 10 ng/L overall, 5 ng/L for females and 12 ng/L for males. CONCLUSIONS: Analytical observations of the Mindray hs-cTnI assay demonstrated excellent LoB, LoD, precision, linearity and analytical specificity, that were in alignment with the manufacturer's claims and regulatory guidelines for hs-cTnI. The assay is suitable for clinical investigation for patient-oriented studies.

4.
J Appl Lab Med ; 9(3): 526-539, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38442340

RESUMEN

BACKGROUND: Single-sample (screening) rule-out of acute myocardial infarction (AMI) with troponin requires derivation of a single-test screening threshold. In data sets with small event numbers, the lowest one or two concentrations of myocardial infarction (MI) patients dictate the threshold. This is not optimal. We aimed to demonstrate a process incorporating both real and synthetic data for deriving such thresholds using a novel pre-production high-precision point-of-care assay. METHODS: cTnI concentrations were measured from thawed plasma using the Troponin I Next (TnI-Nx) assay (i-STAT; Abbott) in adults on arrival to the emergency department with symptoms suggestive of AMI. The primary outcome was an AMI or cardiac death within 30 days. We used internal-external validation with synthetic data production based on clinical and demographic data, plus the measured TnI-Nx concentration, to derive and validate decision thresholds for TnI-Nx. The target low-risk threshold was a sensitivity of 99% and a high-risk threshold specificity of >95%. RESULTS: In total, 1356 patients were included, of whom 191 (14.1%) had the primary outcome. A total of 500 synthetic data sets were constructed. The mean low-risk threshold was determined to be 5 ng/L. This categorized 38% (95% CI, 6%-68%) to low-risk with a sensitivity of 99.0% (95% CI, 98.6%-99.5%) and a negative predictive value of 99.4% (95% CI, 97.6%-99.8%). A similarly derived high-risk threshold of 25 ng/L had a specificity of 95.0% (95% CI, 94.8%-95.1%) and a positive predictive value of 74.8% (95% CI, 71.5%-78.0%). CONCLUSIONS: With the TnI-Nx assay, we successfully demonstrated an approach using synthetic data generation to derive low-risk thresholds for safe and effective screening.


Asunto(s)
Servicio de Urgencia en Hospital , Infarto del Miocardio , Troponina I , Humanos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/sangre , Servicio de Urgencia en Hospital/estadística & datos numéricos , Masculino , Femenino , Troponina I/sangre , Persona de Mediana Edad , Anciano , Pruebas en el Punto de Atención , Biomarcadores/sangre , Sistemas de Atención de Punto , Sensibilidad y Especificidad , Tamizaje Masivo/métodos , Tamizaje Masivo/normas
6.
Emerg Med J ; 41(5): 313-319, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38316538

RESUMEN

OBJECTIVE: We sought to validate the clinical performance of a rapid assessment pathway incorporating the Siemens Atellica IM high sensitivity cardiac troponin I (hs-cTnI) assay in patients presenting to the emergency department (ED) with suspected acute myocardial infarction (AMI). METHODS: This was a multicentre prospective observational study of adult ED patients presenting to five Australian hospitals between November 2020 and September 2021. Participants included those with symptoms of suspected AMI (without ST-segment elevation MI on presentation ECG). The Siemen's Atellica IM hs-cTnI laboratory-based assay was used to measure troponin concentrations at admission and after 2-3 hours and cardiologists adjudicated final diagnoses. The HighSTEACS diagnostic algorithm was evaluated, incorporating hs-cTnI concentrations at presentation and absolute changes within the first 2 to 3 hours. The primary outcome was index AMI, including type 1 or 2 non-ST segment elevation MI (NSTEMI) or ST-elevation MI (STEMI) following presentation. 30-day major adverse cardiac outcomes (including AMI, urgent revascularisation or cardiac death) were also reported. The trial was registered with the Australian and New Zealand Clinical Trials Registry. RESULTS: 1994 patients were included. The average age was 56.2 years (SD=15.6), and 44.9% were women. 118 (5.9%) patients had confirmed index AMI. The 2-hour algorithm defined 61.3% of patients as low risk. Sensitivity was 99.1% (94.0%-99.9%) and negative predictive value was 99.9% (99.3%-100%). 24.4% of patients were deemed intermediate risk. When applying the parameters for high risk, 252 (14.3%) were identified, with a specificity of 91.5% (88.7%-93.6%) and a PPV of 42.0% (35.6-48.7%). CONCLUSIONS: A 2-hour algorithm based on the HighSTEACS strategy using the Siemens Atellica IM hs-cTnI laboratory-based assay enables safe and efficient risk assessment of emergency patients with suspected AMI. TRIAL REGISTRATION NUMBER: ACTRN12621000053820.

7.
Viruses ; 16(2)2024 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-38400067

RESUMEN

This study aimed to evaluate and compare the performance of three anti-S and one anti-N assays that were available to the project in detecting antibody levels after three commonly used SARS-CoV-2 vaccines (Pfizer, Moderna, and Johnson & Johnson). It also aimed to assess the association of age, sex, race, ethnicity, vaccine timing, and vaccine side effects on antibody levels in a cohort of 827 individuals. In September 2021, 698 vaccinated individuals donated blood samples as part of the Association for Diagnostics & Laboratory Medicine (ADLM) COVID-19 Immunity Study. These individuals also participated in a comprehensive survey covering demographic information, vaccination status, and associated side effects. Additionally, 305 age- and gender-matched samples were obtained from the ADLM 2015 sample bank as pre-COVID-19-negative samples. All these samples underwent antibody level analysis using three anti-S assays, namely Beckman Access SARS-CoV-2 IgG (Beckman assay), Ortho Clinical Diagnostics VITROS Anti-SARS-CoV-2 IgG (Ortho assay), Siemens ADVIA Centaur SARS-CoV-2 IgG (Siemens assay), and one anti-N antibody assay: Bio-Rad Platelia SARS-CoV-2 Total Ab assay (BioRad assay). A total of 827 samples (580 COVID-19 samples and 247 pre-COVID-19 samples) received results for all four assays and underwent further analysis. Beckman, Ortho, and Siemens anti-S assays showed an overall sensitivity of 99.5%, 97.6%, and 96.9%, and specificity of 90%, 100%, and 99.6%, respectively. All three assays indicated 100% sensitivity for individuals who received the Moderna vaccine and boosters, and over 99% sensitivity for the Pfizer vaccine. Sensitivities varied from 70.4% (Siemens), 81.5% (Ortho), and 96.3% (Beckman) for individuals who received the Johnson & Johnson vaccine. BioRad anti-N assays demonstrated 46.2% sensitivity and 99.25% specificity based on results from individuals with self-reported infection. The highest median anti-S antibody levels were measured in individuals who received the Moderna vaccine, followed by Pfizer and then Johnson & Johnson vaccines. Higher anti-S antibody levels were significantly associated with younger age and closer proximity to the last vaccine dose but were not associated with gender, race, or ethnicity. Participants with higher anti-S levels experienced significantly more side effects as well as more severe side effects (e.g., muscle pain, chills, fever, and moderate limitations) (p < 0.05). Anti-N antibody levels only indicated a significant correlation with headache. This study indicated performance variations among different anti-S assays, both among themselves and when analyzing individuals with different SARS-CoV-2 vaccines. Caution should be exercised when conducting large-scale studies to ensure that the same platform and/or assays are used for the most effective interpretation of the data.


Asunto(s)
COVID-19 , Vacunas , Humanos , SARS-CoV-2 , Vacunas contra la COVID-19 , COVID-19/diagnóstico , COVID-19/prevención & control , Anticuerpos Antivirales , Inmunoglobulina G , Inmunoensayo
8.
J Appl Lab Med ; 9(2): 371-385, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38059919

RESUMEN

In 2021, the Association for Diagnostics & Laboratory Medicine (ADLM) (formerly the American Association for Clinical Chemistry [AACC]) developed a scientific study that aimed to contribute to the understanding of SARS-CoV-2 immunity during the evolving course of the pandemic. This study was led by a group of expert member volunteers and resulted in survey data from 975 individuals and blood collection from 698 of those participants. This paper describes the formulation and execution of this large-scale scientific study, encompassing best practices and insights gained throughout the endeavor.


Asunto(s)
COVID-19 , Humanos , Pandemias , SARS-CoV-2 , Química Clínica , Sociedades
9.
Clin Chem ; 70(3): 497-505, 2024 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-38102065

RESUMEN

BACKGROUND: Cardiac troponin measurements are indispensable for the diagnosis of myocardial infarction and provide useful information for long-term risk prediction of cardiovascular disease. Accelerated diagnostic pathways prevent unnecessary hospital admission, but require reporting cardiac troponin concentrations at low concentrations that are sometimes below the limit of quantification. Whether analytical imprecision at these concentrations contributes to misclassification of patients is debated. CONTENT: The International Federation of Clinical Chemistry Committee on Clinical Application of Cardiac Bio-Markers (IFCC C-CB) provides evidence-based educational statements on analytical and clinical aspects of cardiac biomarkers. This mini-review discusses how the reporting of low concentrations of cardiac troponins impacts on whether or not assays are classified as high-sensitivity and how analytical performance at low concentrations influences the utility of troponins in accelerated diagnostic pathways. Practical suggestions are made for laboratories regarding analytical quality assessment of cardiac troponin results at low cutoffs, with a particular focus on accelerated diagnostic pathways. The review also discusses how future use of cardiac troponins for long-term prediction or management of cardiovascular disease may require improvements in analytical quality. SUMMARY: Clinical guidelines recommend using cardiac troponin concentrations as low as the limit of detection of the assay to guide patient care. Laboratories, manufacturers, researchers, and external quality assessment providers should extend analytical performance monitoring of cardiac troponin assays to include the concentration ranges applicable in these pathways.


Asunto(s)
Bioensayo , Infarto del Miocardio , Humanos , Química Clínica , Hospitalización , Infarto del Miocardio/diagnóstico , Troponina
11.
Scand Cardiovasc J ; 57(1): 2272585, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37905548

RESUMEN

OBJECTIVES: Patients presenting with symptoms suggestive of acute coronary syndrome (ACS) contribute to a high workload and overcrowding in the Emergency Department (ED). Accelerated diagnostic protocols for non-ST-elevation myocardial infarction have proved challenging to implement. One obstacle is the turnaround time for analyzing high-sensitivity cardiac troponin (hs-cTn). In the WESTCOR-POC study (Clinical Trials number NCT05354804) we aim to evaluate safety and efficiency of a 0/1 h hs-cTn algorithm utilizing a hs-cTnI point of care (POC) instrument in comparison to central laboratory hs-cTnT measurements. DESIGN: This is a prospective single-center randomized clinical trial aiming to include 1500 patients admitted to the ED with symptoms suggestive of ACS. Patients will receive standard investigations following the European Society of Cardiology 0/1h protocols for centralized hs-cTnT measurements or the intervention using a 0/1h POC hs-cTnI algorithm. Primary end-points are 1) Safety; death, myocardial infarction or acute revascularization within 30 days 2) Efficiency; length of stay in the ED, 3) Cost- effectiveness; total episode cost, 4) Patient satisfaction, 5) Patient symptom burden and 6) Patients quality of life. Secondary outcomes are 12-months death, myocardial infarction or acute revascularization, percentage discharged after 3 and 6 h, total length of hospital stay and all costs related to hospital contact within 12 months. CONCLUSION: Results from this study may facilitate implementation of POC hs-cTn testing assays and accelerated diagnostic protocols in EDs, and may serve as a valuable resource for guiding future investigations for the use of POC high sensitivity troponin assays in outpatient clinics and prehospital settings.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Humanos , Sistemas de Atención de Punto , Estudios Prospectivos , Calidad de Vida , Infarto del Miocardio/diagnóstico , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Troponina I , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/etiología , Pruebas en el Punto de Atención , Biomarcadores , Troponina T
12.
J Am Coll Cardiol ; 82(1): 60-69, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37380305

RESUMEN

The term "single-sample rule-out" refers to the ability of very low concentrations of high-sensitivity cardiac troponin (hs-cTn) on presentation to exclude acute myocardial infarction with high clinical sensitivity and negative predictive value. Observational and randomized studies have confirmed this ability. Some guidelines endorse use of a concentration of hs-cTn at the assay's limit of detection, while other studies have validated the use of higher concentrations, allowing this approach to identify a greater proportion of patients at low risk. In most studies, at least 30% of patients can be triaged with this approach. The concentration of hs-cTn varies according to the assay used and sometimes how regulations permit reporting. It is clear that patients need to be at least 2 hours from the onset of symptoms being evaluated. Caution is warranted, particularly with older patients, women, and patients with underlying cardiac comorbidities.


Asunto(s)
Infarto del Miocardio , Humanos , Femenino , Infarto del Miocardio/diagnóstico , Corazón , Triaje , Troponina
13.
Nat Med ; 29(5): 1201-1210, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37169863

RESUMEN

Although guidelines recommend fixed cardiac troponin thresholds for the diagnosis of myocardial infarction, troponin concentrations are influenced by age, sex, comorbidities and time from symptom onset. To improve diagnosis, we developed machine learning models that integrate cardiac troponin concentrations at presentation or on serial testing with clinical features and compute the Collaboration for the Diagnosis and Evaluation of Acute Coronary Syndrome (CoDE-ACS) score (0-100) that corresponds to an individual's probability of myocardial infarction. The models were trained on data from 10,038 patients (48% women), and their performance was externally validated using data from 10,286 patients (35% women) from seven cohorts. CoDE-ACS had excellent discrimination for myocardial infarction (area under curve, 0.953; 95% confidence interval, 0.947-0.958), performed well across subgroups and identified more patients at presentation as low probability of having myocardial infarction than fixed cardiac troponin thresholds (61 versus 27%) with a similar negative predictive value and fewer as high probability of having myocardial infarction (10 versus 16%) with a greater positive predictive value. Patients identified as having a low probability of myocardial infarction had a lower rate of cardiac death than those with intermediate or high probability 30 days (0.1 versus 0.5 and 1.8%) and 1 year (0.3 versus 2.8 and 4.2%; P < 0.001 for both) from patient presentation. CoDE-ACS used as a clinical decision support system has the potential to reduce hospital admissions and have major benefits for patients and health care providers.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Humanos , Femenino , Masculino , Biomarcadores , Troponina I , Infarto del Miocardio/diagnóstico , Síndrome Coronario Agudo/diagnóstico , Aprendizaje Automático
14.
Clin Res Cardiol ; 112(9): 1288-1301, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37131096

RESUMEN

BACKGROUND: In suspected myocardial infarction (MI), guidelines recommend using high-sensitivity cardiac troponin (hs-cTn)-based approaches. These require fixed assay-specific thresholds and timepoints, without directly integrating clinical information. Using machine-learning techniques including hs-cTn and clinical routine variables, we aimed to build a digital tool to directly estimate the individual probability of MI, allowing for numerous hs-cTn assays. METHODS: In 2,575 patients presenting to the emergency department with suspected MI, two ensembles of machine-learning models using single or serial concentrations of six different hs-cTn assays were derived to estimate the individual MI probability (ARTEMIS model). Discriminative performance of the models was assessed using area under the receiver operating characteristic curve (AUC) and logLoss. Model performance was validated in an external cohort with 1688 patients and tested for global generalizability in 13 international cohorts with 23,411 patients. RESULTS: Eleven routinely available variables including age, sex, cardiovascular risk factors, electrocardiography, and hs-cTn were included in the ARTEMIS models. In the validation and generalization cohorts, excellent discriminative performance was confirmed, superior to hs-cTn only. For the serial hs-cTn measurement model, AUC ranged from 0.92 to 0.98. Good calibration was observed. Using a single hs-cTn measurement, the ARTEMIS model allowed direct rule-out of MI with very high and similar safety but up to tripled efficiency compared to the guideline-recommended strategy. CONCLUSION: We developed and validated diagnostic models to accurately estimate the individual probability of MI, which allow for variable hs-cTn use and flexible timing of resampling. Their digital application may provide rapid, safe and efficient personalized patient care. TRIAL REGISTRATION NUMBERS: Data of following cohorts were used for this project: BACC ( www. CLINICALTRIALS: gov ; NCT02355457), stenoCardia ( www. CLINICALTRIALS: gov ; NCT03227159), ADAPT-BSN ( www.australianclinicaltrials.gov.au ; ACTRN12611001069943), IMPACT ( www.australianclinicaltrials.gov.au , ACTRN12611000206921), ADAPT-RCT ( www.anzctr.org.au ; ANZCTR12610000766011), EDACS-RCT ( www.anzctr.org.au ; ANZCTR12613000745741); DROP-ACS ( https://www.umin.ac.jp , UMIN000030668); High-STEACS ( www. CLINICALTRIALS: gov ; NCT01852123), LUND ( www. CLINICALTRIALS: gov ; NCT05484544), RAPID-CPU ( www. CLINICALTRIALS: gov ; NCT03111862), ROMI ( www. CLINICALTRIALS: gov ; NCT01994577), SAMIE ( https://anzctr.org.au ; ACTRN12621000053820), SEIGE and SAFETY ( www. CLINICALTRIALS: gov ; NCT04772157), STOP-CP ( www. CLINICALTRIALS: gov ; NCT02984436), UTROPIA ( www. CLINICALTRIALS: gov ; NCT02060760).


Asunto(s)
Infarto del Miocardio , Troponina I , Humanos , Angina de Pecho , Biomarcadores , Infarto del Miocardio/diagnóstico , Curva ROC , Troponina T , Estudios Clínicos como Asunto
15.
Clin Chem ; 69(6): 627-636, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37022774

RESUMEN

BACKGROUND: Our study addressed the diagnostic performance of the Atellica® IM High-Sensitivity Troponin I (hs-cTnI) assay for the rapid rule-out of myocardial infarction (MI) using a single hs-cTnI measurement at presentation in patients presenting to a US emergency department (ED). METHODS: This was a prospective, observational, cohort study of consecutive ED patients with suspected acute coronary syndrome, using 12-lead electrocardiogram and serial hs-cTnI measurements ordered on clinical indication (SAFETY, NCT04280926). ST-segment elevation MI patients were excluded. The optimal threshold required a sensitivity ≥99% and a negative predictive value (NPV) ≥99.5% for MI during index hospitalization as primary outcome. Type 1 MI (T1MI), myocardial injury, and 30-day adverse events were considered secondary outcomes. Event adjudications were established using the hs-cTnI assay used in clinical care. RESULTS: In 1171 patients, MI occurred in 97 patients (8.3%), 78.3% of which were type 2 MI. The optimal rule out hs-cTnI threshold was <10 ng/L, which identified 519 (44.3%) patients as low risk at presentation, with sensitivity of 99.0% (95% CI, 94.4-100) and NPV of 99.8% (95% CI, 98.9-100). For T1MI, sensitivity was 100% (95% CI, 83.9-100) and NPV 100% (95% CI, 99.3-100). Regarding myocardial injury, the sensitivity and NPV were 99.5% (95% CI, 97.9-100) and 99.8% (95% CI, 98.9-100), respectively. For 30-day adverse events, sensitivity was 96.8% (95% CI, 94.3-98.4) and NPV 97.9% (95% CI, 96.2-98.9). CONCLUSIONS: A single hs-cTnI measurement strategy enabled the rapid identification of patients at low risk of MI and 30-day adverse events, allowing potential discharge early after ED presentation. CLINICALTRIALS.GOV REGISTRATION NUMBER: NCT04280926.


Asunto(s)
Infarto del Miocardio , Troponina I , Humanos , Estudios de Cohortes , Estudios Prospectivos , Infarto del Miocardio/diagnóstico , Servicio de Urgencia en Hospital , Biomarcadores , Troponina T
16.
Kidney Int ; 103(6): 1028-1037, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37023851

RESUMEN

Cardiovascular disease is the leading cause of death in patients receiving hemodialysis. Currently, there is no standardized definition of myocardial infarction (MI) for patients receiving hemodialysis. Through an international consensus process MI was established as the core CVD measure for this population in clinical trials. The Standardised Outcomes in Nephrology Group-Hemodialysis (SONG-HD) initiative convened a multidisciplinary, international working group to address the definition of MI in this population. On the basis of current evidence, the working group recommends using the Fourth Universal Definition of Myocardial Infarction with specific caveats with regard to the interpretation of "ischemic symptoms" and performing a baseline 12-lead electrocardiogram to facilitate interpretation of acute changes on subsequent tracings. The working group does not recommend obtaining baseline cardiac troponin values, though does recommend obtaining serial cardiac biomarkers in settings where ischemia is suspected. The application of an evidence-based uniform definition should increase the reliability and accuracy of trial results.


Asunto(s)
Infarto del Miocardio , Nefrología , Humanos , Consenso , Reproducibilidad de los Resultados , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Diálisis Renal/efectos adversos , Diálisis Renal/métodos , Biomarcadores
17.
Clin Chem Lab Med ; 61(8): 1411-1419, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-36952681

RESUMEN

The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.


Asunto(s)
Infarto del Miocardio , Humanos , Biomarcadores , Química Clínica , Anticuerpos , Troponina
18.
Viruses ; 15(3)2023 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-36992418

RESUMEN

OBJECTIVES: The objective of this prospective study was to investigate the role of adaptive immunity in response to SARS-CoV-2 vaccines. DESIGN AND METHODS: A cohort of 677 vaccinated individuals participated in a comprehensive survey of their vaccination status and associated side effects, and donated blood to evaluate their adaptive immune responses by neutralizing antibody (NAb) and T cell responses. The cohort then completed a follow-up survey to investigate the occurrence of breakthrough infections. RESULTS: NAb levels were the highest in participants vaccinated with Moderna, followed by Pfizer and Johnson & Johnson. NAb levels decreased with time after vaccination with Pfizer and Johnson & Johnson. T cell responses showed no significant difference among the different vaccines and remained stable up to 10 months after the study period for all vaccine types. In multivariate analyses, NAb responses (<95 U/mL) predicted breakthrough infection, whereas previous infection, the type of vaccine, and T cell responses did not. T cell responses to viral epitopes (<0.120 IU/mL) showed a significant association with the self-reported severity of COVID-19 disease. CONCLUSION: This study provides evidence that NAb responses to SARS-CoV-2 vaccination correlate with protection against infection, whereas the T cell memory responses may contribute to protection against severe disease but not against infection.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Humanos , COVID-19/prevención & control , SARS-CoV-2 , Autoinforme , Infección Irruptiva , Estudios Prospectivos , Gravedad del Paciente , Anticuerpos Neutralizantes , Vacunación , Anticuerpos Antivirales
19.
Clin Biochem ; 114: 79-85, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36780933

RESUMEN

INTRODUCTION: This study examined the analytical performance of a whole blood (WB) point of care (POC) hs-cTnI assay compared to a plasma central laboratory hs-cTnI assay in patients presenting with ischemic symptoms to a US emergency department. METHODS: Fresh WB specimens collected at 0 and 2 h from 1089 consecutive patients (2152 total from 1076 matched specimens) were analyzed for hs-cTnI using WB on POC Siemens Atellica VTLi assay and plasma on central laboratory Siemens Atellica IM assay. Concordances were determined based on concentrations ranging from < limit of detection (LoD), LoD to overall and sex specific 99th percentiles from both the IFCC manufacturer package inserts and Universal Sample Bank (USB) data, and > 99th percentiles. Method comparisons were calculated using Passing Bablok regression and Bland Altmann plots, and linear regression determined by Pearson correlation coefficient. RESULTS: Baseline concentration comparisons showed: POC VTLi < LoD 4-5 %, ≥ LoD 95 %; Atellica IM < LoD 5-7 %, and ≥ LoD 94-95 %. From the 2152 paired 0 and 2-hour samples, based on 99th percentiles, overall concordance was 91-92 % (kappa 0.72-0.77) and discordance 8 %. Passing Bablok regression analysis using 1924 specimens between LoD to 500 ng/L showed: slopes 0.469-0.490; y-intercepts 1.753-2.028; r values 0.631-0.817. Pearson correlation coefficient showed moderate to strong correlation strength, even with up to 53 % cTnI concentrations variance (Passing Bablok slopes) vs 27.0-40.1 % (Bland-Altmann plots). CONCLUSIONS: Up to 95 % of measured samples were > LoD for both the POC (Atellica VTLi) and central laboratory (Atellica IM) hs-cTnI assays. Moderate to strong concordance and correlation were observed between assays, despite up to 53 % variances in cTnI concentration.


Asunto(s)
Sistemas de Atención de Punto , Troponina I , Masculino , Femenino , Humanos , Límite de Detección , Bioensayo/métodos , Laboratorios
20.
Clin Chem Lab Med ; 61(6): 989-998, 2023 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-36637984

RESUMEN

The International Federation of Clinical Chemistry and Laboarator Medicine (IFCC) Committee on Clinical Applications of Cardiac Bio-Markers (C-CB) has provided evidence-based educational resources to aid and improve the understanding of important analytical and clinical aspects of cardiac biomarkers. The present IFCC C-CB educational report focuses on recommendations for appropriate use, analytical performance, and gaps in clinical studies related to the use of cardiac troponin (cTn) by point of care (POC) measurement, often referred to as a point of care testing (POCT). The use of high-sensitivity (hs)-cTn POC devices in accelerated diagnostic protocols used in emergency departments or outpatient clinics investigating acute coronary syndrome has the potential for improved efficacy, reduction of length of stay and reduced costs in the health care system. POCT workflow integration includes location of the instrument, assignment of collection and testing responsibility to (non-lab) staff, instrument maintenance, in-service and recurrent training, quality control, proficiency assessments, discrepant result trapping, and troubleshooting and inventory management.


Asunto(s)
Síndrome Coronario Agudo , Sistemas de Atención de Punto , Humanos , Biomarcadores , Síndrome Coronario Agudo/diagnóstico , Química Clínica , Troponina , Troponina T