1.
Clin Ophthalmol ; 18: 2419-2426, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39224175

RESUMEN

Purpose: To study the association between tear film hyperosmolarity and ocular light scatter in a cataract surgery population. Patients and Methods: Contiguous, 20-second objective scatter index (OSI) scans were recorded in hyperosmolar (≥320 mOsm/L) and normal subjects (<308 mOsm/L) with cataract nuclear opacity ≥3. OSI was measured at screening, baseline and 90 days following surgery. Along with symptoms of ocular surface disease, slit-lamp examination included corneal staining (0-3), tear film breakup time (TBUT) and evaluation of meibomian gland disease (MGD). An additional cohort of hyperosmolar subjects were measured for OSI at screening, baseline, and 5, 10, 15 and 30 minutes following instillation of 0.18% sodium hyaluronate (HA). Results: Thirty-one eyes of 31 patients were included. There was a significant difference in post-operative OSI variation when comparing hyperosmolar (0.65±0.30, N=11) to normal subjects (0.33±0.11, N=10, p=0.005). Of note, there were no significant differences in OSI variation when subjects were sorted by staining (p=0.9), TBUT (p=0.7), symptoms (p=0.7), or MGD status (p=0.9). Instillation of 0.18% HA (N=10) did not alter OSI at 5 minutes, but significant reductions in OSI of 28.8%, 38.5% and 36.7% (all p < 0.001) were observed at 10, 15 and 30 minutes. Conclusion: Hyperosmolar patients exhibited significantly increased variation in light scatter following cataract surgery that was undifferentiated by staining or TBUT. Elevated osmolarity may be indicative of light scatter equivalent to that of a grade 2-3 cataract.

2.
Ophthalmic Physiol Opt ; 44(6): 1237-1247, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38980146

RESUMEN

PURPOSE: Defocus Incorporated Soft Contact (DISC) lenses, a commonly used type of multifocal lens in clinical practice, may slow down myopia progression by inducing myopic retinal defocus. The purpose of this study was to explore whether the induced defocus across the retina could be affected by visual environments encountered in the real world, such as differences in viewing distance and ambient illuminance. METHODS: In this cross-over trial, 30 myopic adults wore both DISC lenses and single vision contact (SVC) lenses in random order. An open-view Hartmann-Shack scanning wavefront sensor was used to measure defocus at different retinal locations along the horizontal meridian under four experimental conditions: far target (3 m) and near targets (0.33 m) under scotopic (<1 lux) or photopic (~300 lux) conditions. RESULTS: The results showed that DISC lenses induced more myopic retinal defocus than SVC lenses in all conditions (all p < 0.05), except for the scotopic near target. In addition, for DISC lenses, the defocus was greater in the photopic than the scotopic conditions for both the far and near targets (both p < 0.05). CONCLUSION: In conclusion, the retinal defocus induced by these multifocal lenses was dependent on both visual distance and ambient illuminance, indicating that the visual conditions might affect the anti-myopia efficacy of these devices.


Asunto(s)
Lentes de Contacto Hidrofílicos , Estudios Cruzados , Miopía , Humanos , Miopía/fisiopatología , Miopía/terapia , Adulto , Masculino , Femenino , Adulto Joven , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Iluminación
3.
Eye Vis (Lond) ; 11(1): 26, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39085950

RESUMEN

BACKGROUND: Atropine, specifically 0.05% eyedrops, has proven effective in slowing myopia progression. This study aims to investigate peripheral refraction (PR) characteristics in myopic children treated with 0.05% atropine eyedrops at different frequencies. METHODS: One hundred thirty-eight myopic children completed this one-year prospective study, randomly assigned to once daily (7/7), twice per week (2/7), or once per week (1/7) groups. Spherical equivalent (SE) and axial length (AL) were measured. PR was assessed using a custom-made Hartmann-Shack wavefront peripheral sensor, covering a visual field of horizontal 60° and vertical 36°. Relative peripheral refraction (RPR) was calculated by subtracting central from peripheral measurements. RESULTS: After one year, SE increased more significantly in the 1/7 group compared to the 7/7 group (P < 0.001) and 2/7 group (P = 0.004); AL elongation was also greater in the 1/7 group compared to the 7/7 group (P < 0.001). In comparison with higher frequency groups, 1/7 group exhibited more myopic PR in the fovea and its vertical superior, inferior, and nasal retina; and less myopic RPR in the periphery retina after one-year (P < 0.05). Additionally, RPR in the 7/7 group demonstrated myopic shift across the entire retina, the 2/7 group in temporal and inferior retina, while the 1/7 group showed a hyperopic shift in the superior retina (P < 0.05). Moreover, myopic shift of RPR in the temporal retina is related to less myopia progression, notably in the 7/7 group (P < 0.05). CONCLUSIONS: Atropine inhibits myopia progression in a frequency-dependent manner. The once-daily group showed the slowest myopia progression but exhibited more myopic shifts in RPR. Additionally, RPR in the temporal retina was related to myopia progression in all groups. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR2100043506. Registered 21 February 2021, https://www.chictr.org.cn/showproj.html?proj=122214.

4.
Biomed Opt Express ; 15(6): 3848-3858, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38867768

RESUMEN

This study investigates the potential effects of periodic defocus oscillations on contrast sensitivity. Sinusoidal fluctuations at 5, 15, and 25 Hz, with defocus peak-to-valley values ranging from 0.15 to 3 D, were induced by means of a focus-tunable lens after calibrating its dynamic behavior. Monocular contrast sensitivity was measured on five young emmetropic subjects. The experimental data shows that contrast sensitivity loss due to defocus fluctuations is low for a wide range of frequencies and amplitudes. Only for the more severe case studied (25 Hz, ± 1.5 D) contrast threshold showed a clear increase in most subjects. Qualitative comparison of the empirical data with a simulation of modulation loss due to time integration of defocused retinal point spread functions, suggests a short integration time by the eye for defocus blur, around or even below a hundredth of a second.

5.
Opt Express ; 32(8): 13797-13808, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38859340

RESUMEN

The presence of scattering media limits the quality of images obtained by optical systems. Single-pixel imaging techniques based on structured illumination are highly tolerant to the presence of scattering between the object and the sensor, but very sensitive when the scattering medium is between the light source and the object. This makes it difficult to develop single-pixel imaging techniques for the case of objects immersed in scattering media. We present what we believe to be a new system for imaging objects through inhomogeneous scattering media in an epi-illumination configuration. It works in an adaptive way by combining diffuse optical imaging (DOI) and single pixel imaging (SPI) techniques in two stages. First, the turbid media is characterized by projecting light patterns with an LED array and applying DOI techniques. Second, the LED array is programmed to project light only through the less scattering areas of the media, while simultaneously using a digital micromirror device (DMD) to project light patterns onto the target using Hadamard basis coding functions. With this adaptive technique, we are able to obtain images of targets through two different scattering media with better quality than using conventional illumination. We also show that the system works with fluorescent targets.

6.
Invest Ophthalmol Vis Sci ; 65(6): 42, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38940761

RESUMEN

Purpose: The purpose of this study was to investigate the functional effects of peripheral refractive errors on mobility performance through a stair negotiation task. Methods: Twenty-one young, normal sighted subjects navigated through an obstacle with steps, wearing spectacles that altered only their peripheral refraction. Lenses were used to induce positive defocus (+2 diopters [D] and +4 D), negative defocus (-2 D and -4 D), or astigmatism (+1.75 D and -3.75 D, axis 45 degrees) in the periphery. Feet trajectories were analyzed, and several gait assessment parameters were obtained. Statistical tests were conducted to determine significant performance differences between the lenses. Peripheral refraction in each subject was measured using a scanning Hartmann-Shack wavefront sensor to assess the impact of intrinsic peripheral refraction on the experiment. Results: Statistically significant differences in performance appeared when peripheral errors were superimposed. Crossing time with respect to plano lenses increased by 6.2%, 7.6%, 19.2%, and 29.6% for the -2 D, +2 D, -4 D, and +4 D lenses, respectively (P < 0.05 in the last 3 cases). Subjects exhibited slower walking speeds, increased step count, and adopted precautionary measures. High-power positive defocus lenses had the biggest impact on performance, and differences were observed in distance to steps between induced positive and negative defocus. Conclusions: In this laboratory-based study without an adaptation period, peripheral refractive errors affected stair negotiation, causing cautious behavior in subjects. Performance differences among types of peripheral defocus may result from magnification effects and intrinsic peripheral refraction. These results highlight the importance of understanding the effects of induced peripheral errors by myopia control and intraocular lenses.


Asunto(s)
Refracción Ocular , Errores de Refracción , Humanos , Masculino , Femenino , Adulto , Refracción Ocular/fisiología , Errores de Refracción/fisiopatología , Adulto Joven , Anteojos , Agudeza Visual/fisiología , Marcha/fisiología , Caminata/fisiología
7.
Invest Ophthalmol Vis Sci ; 65(5): 20, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38727692

RESUMEN

Purpose: Vision-degrading myodesopsia (VDM) from vitreous floaters significantly degrades vision and impacts visual quality of life (VQOL), but the relationship to light scattering is poorly understood. This study compared in vitro measures of light scatter and transmission in surgically excised human vitreous to preoperative indexes of vitreous structure, visual function, and VQOL. Methods: Pure vitreous collected during vitrectomy from 8 patients with VDM had wide-angle straylight measurements and dark-field imaging, performed within 36 hours of vitrectomy. Preoperative VQOL assessment with VFQ-25, contrast sensitivity (CS) measurements with Freiburg acuity contrast testing, and quantitative ultrasonography were compared to light scattering and transmission in vitro. Results: All indices of vitreous echodensity in vivo correlated positively with straylight at 0.5° (R = 0.708 to 0.775, P = 0.049 and 0.024, respectively). Straylight mean scatter index correlated with echodensity (R = 0.71, P = 0.04) and VQOL (R = -0.82, P = 0.0075). Dark-field measures in vitro correlated with degraded CS in vivo (R = -0.69, P = 0.04). VQOL correlated with straylight mean scatter index (R = -0.823, P = 0.012). Conclusions: Increased vitreous echodensity in vivo is associated with more straylight scattering in vitro, validating ultrasonography as a clinical surrogate for light scattering. Contrast sensitivity in vivo is more degraded in the presence of dark-field scattering in vitro and VQOL is decreased in patients whose vitreous has increased light scattering. These findings could form the basis for the development of optical corrections for VDM or support new laser treatments, as well as novel pharmacotherapy.


Asunto(s)
Sensibilidad de Contraste , Luz , Dispersión de Radiación , Agudeza Visual , Vitrectomía , Cuerpo Vítreo , Humanos , Cuerpo Vítreo/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Agudeza Visual/fisiología , Sensibilidad de Contraste/fisiología , Anciano , Calidad de Vida , Trastornos de la Visión/fisiopatología , Adulto , Ultrasonografía , Oftalmopatías/fisiopatología , Oftalmopatías/diagnóstico por imagen
8.
Biomed Opt Express ; 15(4): 2517-2523, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38633073

RESUMEN

Both cataracts and age-related macular degeneration (AMD) may occur with aging and are often developed simultaneously. We performed a study to better characterize the impact of induced scatter on the quality of vision in the near periphery, a region where individuals with AMD typically maintain their functional vision. We used an optical instrument as a cataract simulator based on projecting at the eye's pupil plane phase masks with controlled spatial properties generated with a spatial light modulator. The phase wavefronts were designed to accurately replicate the angular distribution of light intensity in the retina found in cataractous eyes with different severities. The induced amount of scatter ranged from values of straylight (S) from 10 to 85 degree2/sr, which corresponds from normal aging eye to advanced cataract stages. Mesopic visual acuity (VA) and contrast sensitivity (CS) at 3 cycles per degree were measured at the fovea and two retinal eccentricities (5 and 10 degrees in nasal visual field). We observed a consistent linear decline in VA (expressed in LogMAR) as the amount of induced scatter (quantified by the straylight parameter S) increased, both at the fovea and in the periphery. The effect of induced scattering on mesopic VA and CS at the fovea and the near periphery was evaluated. We found a relatively lower impact of scatter in the near periphery. This may explain the modest improvement in vision often found after cataract surgery in patients with AMD.

9.
Am J Ophthalmol ; 264: 120-134, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38521156

RESUMEN

PURPOSE: To update the literature on peripheral optics and vision following intraocular lens (IOLs) implantation. METHODS: We investigated how current IOLs influence peripheral visual function, peripheral optical quality, and visual perception and performance, in patients following cataract surgery. Peripheral vision is described as vision outside the central foveal region of the eye (beyond 4-5° of eccentricity). We systematically searched PubMed, Cochrane Central Register of Controlled Trials, Embase, and gray literature for relevant references. Randomized controlled trials and observational studies were eligible for inclusion. Finally, 47 studies with a total of 5963 participants were eligible for this review, of which 15 were included in the meta-analysis. RESULTS: Regarding visual fields, the meta-analysis showed that the pooled estimate of mean deviation (MD) measured with perimetry tests (standard automated perimetry [SAP], short-wavelength automated perimetry [SWAP], and frequency doubling technology [FDT]) appears to be lower than the mean of healthy age-matched controls, regardless of IOL design. Results for pooled estimate show that localized defects (pattern standard deviation [PSD]) were higher than those in the healthy age-matched controls for FDT. We also collected evidence demonstrating that pseudophakia increases peripheral astigmatism and a myopic shift from 20° onward, leading to decreased peripheral image quality compared with that in phakic eyes. Patient-reported outcomes on peripheral vision showed a pooled score estimate of 95.19, indicating high satisfaction, and for the Steps & Stairs questions, a pooled score estimate at 0.23, indicating no to little difficulty seeing steps and stairs. CONCLUSIONS: Peripheral image quality is degraded in eyes after cataract surgery. Nevertheless, whether this degradation leads to impaired visual function in the periphery requires further investigation.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Agudeza Visual , Campos Visuales , Humanos , Agudeza Visual/fisiología , Campos Visuales/fisiología , Percepción Visual/fisiología , Pruebas del Campo Visual , Seudofaquia/fisiopatología , Refracción Ocular/fisiología
10.
Ophthalmic Physiol Opt ; 44(4): 718-726, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38551074

RESUMEN

PURPOSE: To compare the ocular effects of exposure to a low-humidity environment with and without contact lens (CL) wear using various non-invasive tests. METHODS: Fourteen habitual soft CL wearers were exposed to controlled low humidity (5% relative humidity [RH]) in an environmental chamber for 90 min on two separate occasions. First, when wearing their habitual spectacles and then, on a separate visit, when wearing silicone hydrogel CLs that were fitted specifically for this purpose. All participants had adapted to the new CL prior to data collection. Three non-invasive objective measurements were taken at each visit: blinking rate, objective ocular scatter (measured using the objective scatter index) and ocular surface cooling rate (measured using a long-wave infrared thermal camera). At each visit, measurements were taken before the exposure in comfortable environmental conditions (RH: 45%), and after exposure to environmental stress (low humidity, RH: 5%). RESULTS: CL wearers showed increased blinking rate (p < 0.005) and ocular scatter (p = 0.03) but similar cooling rate of the ocular surface (p = 0.08) when compared with spectacle wear in comfortable environmental conditions. The exposure to low humidity increased the blinking rate significantly with both types of corrections (p = 0.01). Interestingly, ocular scatter (p = 0.96) and cooling rate (p = 0.73) were not significantly different before and after exposure to low humidity. There were no significant two-way interactions between correction and exposure in any of the measurements. CONCLUSIONS: CLs significantly increased the blinking rate, which prevented a quick degradation of the tear film integrity as it was refreshed more regularly. It is hypothesised that the increased blinking rate in CL wearers aids in maintaining ocular scatter quality and cooling rate when exposed to a low-humidity environment. These results highlight the importance of blinking in maintaining tear film stability.


Asunto(s)
Parpadeo , Humedad , Humanos , Proyectos Piloto , Parpadeo/fisiología , Adulto , Masculino , Femenino , Adulto Joven , Lentes de Contacto Hidrofílicos , Lágrimas/fisiología , Lentes de Contacto
11.
Biomed Opt Express ; 15(2): 608-623, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38404335

RESUMEN

Adaptive optics visual simulation is a powerful tool for vision testing and evaluation. However, the existing instruments either have fixed tabletop configurations or, being wearable, only offer the correction of defocus. This paper proposes a novel head-mounted adaptive optics visual simulator that can measure and modify complex ocular aberrations in real-time. The prototype is composed of two optical modules, one for the objective assessment of aberrations and the second for wavefront modulation, all of which are integrated into a wearable headset. The device incorporates a microdisplay for stimulus generation, a liquid crystal on silicon (LCoS) spatial light modulator for wavefront manipulation, and a Hartmann-Shack wavefront sensor. Miniature optical components and optical path folding structures, together with in-house 3D printed mounts and housing, were adapted to realize the compact size. The system was calibrated by characterizing and compensating the internal aberrations of the visual relay. The performance of the prototype was analyzed by evaluating the measurement and compensation of low-order and higher-order aberrations induced through trial lenses and phase masks in an artificial eye. The defocus curves for a simulated bifocal diffractive lens were evaluated in real eyes. The results show high accuracy while measuring and compensating for the induced defocus, astigmatism, and higher-order aberrations, whereas the MTF analysis shows post-correction resolution of up to 37.5 cycles/degree (VA 1.25). Moreover, the subjective test results show the defocus curves closely matched to a commercial desktop visual simulator.

12.
Sci Rep ; 14(1): 2280, 2024 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-38280921

RESUMEN

Previous studies have demonstrated that the visual system adapts to the specific aberration pattern of an individual's eye. Alterations to this pattern can lead to reduced visual performance, even when the Root Mean Square (RMS) of the wavefront error remains constant. However, it is well-established that ocular aberrations are dynamic and can change with factors such as pupil size and accommodation. This raises an intriguing question: can the neural system adapt to continuously changing aberration patterns? To address this question, we measured the ocular aberrations in four subjects under various natural viewing conditions, which included changes in accommodative state and pupil size. We subsequently computed the associated Point Spread Functions (PSFs). For each subject, we examined the stability in the orientation of the PSFs and analyzed the cross-correlation between different PSFs. These findings were then compared to the characteristics of a distribution featuring PSF shapes akin to random variations. Our results indicate that the changes observed in the PSFs are not substantial enough to produce a PSF shape distribution resembling random variations. This lends support to the notion that neural adaptation is indeed a viable mechanism even in response to continuously changing aberration patterns.


Asunto(s)
Acomodación Ocular , Ojo , Humanos , Cara , Refracción Ocular , Pupila/fisiología
13.
J Cataract Refract Surg ; 50(1): 30-36, 2024 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-37732726

RESUMEN

PURPOSE: To assess the effect of change in ocular spherical aberration (SA) with adaptive optics on visual acuity (VA) at different defocus after implantation of extended depth-of-focus (EDOF) and enhanced monofocal intraocular lenses (IOLs). SETTINGS: Narayana Nethralaya Eye Hospital, Bangalore, India. DESIGN: Prospective, longitudinal, observational. METHODS: 80 eyes (40 patients) that had cataract surgery were included in the study. 40 eyes were implanted with Eyhance EDOF IOLs and the remaining with Vivity EDOF IOLs. Baseline ocular aberrations were measured with a visual adaptive optics aberrometer, then the optimal SA was determined by increasing it in steps of -0.01 µm up to -0.1 µm until the maximum improvement in near distance VA was observed for a given eye. Then the defocus curve for each eye was measured after modifying the ocular SA by magnitude equal to optimal SA. RESULTS: Most of the eyes accepted a negative induced SA of -0.05 µm (Eyhance group: 67.6%; Vivity group, 45.2%). In the Eyhance group (dominant eyes), VA improved at -2 diopters (D) ( P < .02) only and degraded at 0 D, +0.5 D, and +1 D defocus ( P < .05). In the Vivity group, the VA remained unchanged at all defocus ( P > .05). In the Eyhance group (nondominant eyes), VA improved at -3.5 D defocus only and degraded at +1.5 D and +2 D defocus ( P < .05). In the Vivity group, VA improved at -2.5 D defocus ( P < .05) only. CONCLUSIONS: A negative induced SA of -0.05 µm in implanted eyes was optimal for a slight improvement in distance-corrected near and intermediate VA without any significant decrease in baseline distance-corrected VA.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Percepción de Profundidad , India , Satisfacción del Paciente , Estudios Prospectivos , Diseño de Prótesis , Refracción Ocular , Agudeza Visual , Estudios Longitudinales
14.
Eye Vis (Lond) ; 10(1): 46, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38037146

RESUMEN

BACKGROUND: The shape and microstructure of the human crystalline lens alter with ageing, and this has an effect on the optical properties of the eye. The aim of this study was to characterise the age-related differences in the morphology and transparency of the eye lenses of healthy subjects through the optical signal discontinuity (OSD) zones in optical coherence tomography (OCT) images. We also investigated the association of those changes with the optical quality of the eye and visual function. METHODS: OCT images of the anterior segment of 49 eyes of subjects (9-78 years) were acquired, and the OSD zones (nucleus, C1-C4 cortical zones) were identified. Central thickness, curvature and optical density were measured. The eye's optical quality was evaluated by the objective scatter index (OSI). Contrast sensitivity and visual acuity tests were performed. The correlation between extracted parameters and age was assessed. RESULTS: The increase in lens thickness with age was dominated by the thickening of the cortical zone C3 (0.0146 mm/year). The curvature radii of the anterior lens surface and both anterior and posterior nucleo-cortical interfaces decreased with age (- 0.053 mm/year, - 0.013 mm/year and - 0.006 mm/year, respectively), and no change was observed for the posterior lens radius. OCT-based densitometry revealed significant correlations with age for all zones except for C1ß, and the highest increase in density was in the C2-C4 zones (R = 0.45, 0.74, 0.56, respectively, P < 0.001). Increase in OSI was associated with the degradation of visual function. CONCLUSIONS: OCT enables the identification of OSD zones of the crystalline lens. The most significant age-related changes occur in the C3 zone as it thickens with age at a faster rate and becomes more opaque than other OSD zones. The changes are associated with optical quality deterioration and reduction of visual performance. These findings contribute to a better understanding of the structure-function relationship of the ageing lens and offer insights into both pathological and aging alterations.

15.
J Refract Surg ; 39(9): 582-588, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37675912

RESUMEN

PURPOSE: To evaluate visual performance, spectacle independence, and quality of vision of new intraocular lenses (IOLs) for presbyopia correction with an aspheric inverted meniscus optical design (ArtIOLs; Voptica SL) in patients undergoing bilateral cataract surgery. METHODS: In this prospective study, 60 eyes from 30 patients implanted bilaterally with Art40 and Art70 IOLs were included. These new IOLs were designed with an inverted meniscus shape to improve the peripheral performance and with aspheric surfaces to induce different amounts of negative spherical aberration in each IOL model. Distance-corrected and uncorrected through-focus visual acuities and contrast sensitivity were measured 1 to 3 months after surgery. Twenty-eight patients answered Patient Reported Spectacle Independence (PRSIQ) and Quality of Vision (QoV) questionnaires. RESULTS: Mean monocular (Art40 and Art70) and binocular (Art40/70) corrected distance visual acuities (CDVA) were zero logMAR (20/20). Binocular uncorrected distance visual acuity (UDVA) at far, intermediate (66 cm), and near (40 cm) distances was 0.00 ± 0.01, 0.01 ± 0.03, and 0.09 ± 0.09 logMAR, respectively. Spectacle independence was achieved by 24 (85.7%) patients for far and intermediate vision and 20 patients (71.4%) for near vision. The number of patients never reporting experiencing glare, halos, and starbursts was 28, 27, and 26 (100%, 96.4%, and 92.9%), respectively. CONCLUSIONS: The binocular combination of two ArtIOLs models (Art40 and Art70) significantly extended the depth of focus up to at least 40 cm. This combination resulted in a full range of vision with a high level of spectacle independence and without the compromise of halos or dysphotopsias. [J Refract Surg. 2023;39(9):582-588.].


Asunto(s)
Extracción de Catarata , Lentes Intraoculares , Menisco , Humanos , Satisfacción del Paciente , Estudios Prospectivos
16.
Biomed Opt Express ; 14(6): 2608-2617, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37342694

RESUMEN

A novel double-pass instrument and its data analysis method for the measurement of central and peripheral refraction is presented and validated in a group of healthy subjects. The instrument acquires in-vivo, non-cycloplegic, double-pass, through-focus images of the eye's central and peripheral point-spread function (PSF) using an infrared laser source, a tunable lens and a CMOS camera. The through-focus images were analyzed to determine defocus and astigmatism at 0° and 30° visual field. These values were compared to those obtained with a lab-based Hartmann-Shack wavefront sensor. The two instruments provided data showing good correlation at both eccentricities, particularly in the estimation of defocus.

17.
Biomed Opt Express ; 14(5): 2129-2137, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37206130

RESUMEN

Current intraocular lenses (IOLs) are designed to substitute the cataractous crystalline lens, optimizing focus at the fovea. However, the common biconvex design overlooks off-axis performance, leading to a reduced optical quality in the periphery of the retina in pseudophakic patients compared to the normal phakic eye. In this work, we designed an IOL to provide better peripheral optical quality, closer in that respect to the natural lens, using ray-tracing simulations in eye models. The resulting design was a concave-convex inverted meniscus IOL with aspheric surfaces. The curvature radius of the posterior surface was smaller than that of the anterior surface by a factor that depended on the IOL power. The lenses were manufactured and evaluated in a custom-built artificial eye. Images of a point source and of extended targets were directly recorded at various field angles with both standard and the new IOLs. This type of IOL produces superior image quality in the whole visual field, being a better surrogate for the crystalline lens than the commonly used thin biconvex intraocular lenses.

18.
Biomed Opt Express ; 14(5): 2117-2128, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37206134

RESUMEN

Second harmonic generation (SHG) imaging microscopy of thick biological tissues is affected by the presence of aberrations and scattering within the sample. Moreover, additional problems, such as uncontrolled movements, appear when imaging in-vivo. Deconvolution methods can be used to overcome these limitations under some conditions. In particular, we present here a technique based on a marginal blind deconvolution approach for improving SHG images obtained in vivo in the human eye (cornea and sclera). Different image quality metrics are used to quantify the attained improvement. Collagen fibers in both cornea and sclera are better visualized and their spatial distributions accurately assessed. This might be a useful tool to better discriminate between healthy and pathological tissues, especially those where changes in collagen distribution occur.

19.
Biomed Opt Express ; 14(5): 2375-2385, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37206135

RESUMEN

Peripheral refraction has been studied for decades; however, its detection and description are somehow simplistic and limited. Therefore, their role in visual function and refractive correction, as well as myopia control, is not completely understood. This study aims to establish a database of two-dimensional (2D) peripheral refraction profiles in adults and explore the features for different central refraction values. A group of 479 adult subjects were recruited. Using an open-view Hartmann-Shack scanning wavefront sensor, their right naked eyes were measured. The overall features of the relative peripheral refraction maps showed myopic defocus, slight myopic defocus, and hyperopic defocus in the hyperopic and emmetropic groups, in the mild myopic group, and in other myopic groups, respectively. Defocus deviations with central refraction vary in different regions. The defocus asymmetry between the upper and lower retinas within 16° increased with the increase of central myopia. By characterizing the variation of peripheral defocus with central myopia, these results provide rich information for possible individual corrections and lens design.

20.
Invest Ophthalmol Vis Sci ; 64(4): 16, 2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-37057974

RESUMEN

Purpose: To investigate the role of peripheral refraction in children's myopization. Methods: This 2-year study included 214 children (8-15 years old). Refraction across the retina (field of view: 60° × 36°) was measured with a custom-made aberrometer every year. Three datasets were established: dataset 1, 214 subjects from baseline to the first-year visit; dataset 2, 152 subjects from baseline to the second-year visit; and dataset 3, 59 initial emmetropes from baseline to the second-year visit. The baseline refraction of different retina regions was correlated with the central myopic shift, and was compared among groups with different levels of myopic shift. Results: In datasets 1 and 2, the refraction distribution across the retina was significantly different among the subjects who were initially emmetropes but not among those who were initially hyperopic or myopic. Refraction in the central vertical retina, especially in the superior retina (r = -0.5, P < 0.001), was significantly correlated with the myopic shift for emmetropes in that subjects with more relative myopia in the superior retina manifested greater central myopic shifts. In dataset 3, 21 subjects remained emmetropic after 2 years, 15 subjects became myopic at the 1-year visit, and 23 subjects became myopic at the 2-year visit. No difference was found for the relative peripheral refraction in all of the peripheral regions between the stage prior to and after the onset of myopia. Conclusions: Relative myopic defocus in the superior retina could be a predictor of central myopia shift. Changes in relative peripheral refraction are more likely a consequence of myopia progression rather than a cause.


Asunto(s)
Hiperopía , Miopía , Humanos , Niño , Adolescente , Miopía/diagnóstico , Refracción Ocular , Retina , Emetropía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA