Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Can J Cardiol ; 40(1): 113-122, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37726077

RESUMEN

BACKGROUND: Data on the long-term impact of prosthesis-patient mismatch (PPM) on outcomes after transcatheter aortic valve replacement (TAVR) remain sparse. We therefore aimed to investigate the incidence, predictive factors, and long-term prognostic impact of PPM on bioprosthesis durability and mortality. METHODS: This was a single-centre retrospective study including 2117 patients who underwent TAVR for aortic stenosis from 2002 to 2022. Moderate PPM was defined by indexed effective orifice area (iEOA) > 0.65 and ≤ 0.85 cm2/m2 (> 0.55 and ≤ 0.70 cm2/m2 if BMI ≥ 30 kg/m2) and severe PPM by an iEOA ≤ 0.65 cm2/m2 (≤ 0.55 cm2/m2 If BMI ≥ 30 kg/m2). RESULTS: There were 351 patients (16.6%) with PPM, including 39 patients (1.8%) with severe PPM and 312 patients (14.7%) with moderate PPM. The mean follow-up duration was 31.2 ± 26.5 months. Factors independently associated with the occurrence of PPM were body surface area (odds ratio [OR] 3.32, 95% confidence interval [CI] 1.32-8.35; P = 0.01), valve-in-valve TAVR (OR 6.12, 95% CI 2.29-16.08; P < 0.001), small annulus (OR 2.42, 95% CI 1.41-4.07; P = 0.001), and the use of a balloon-expandable valve (OR 4.17, 95% CI 2.17-8.33; P < 0.001). PPM was associated with increased risk of mortality (hazard ratio [HR] 1.3, 95% CI 1.1-1.5, P = 0.004) and valve thrombosis (HR 4.2, 95% CI 1.4-12.6, P = 0.01), and a trend towards increased risk of structural valve deterioration (HR 1.7, 95% CI 0.9-2.9; P = 0.08). CONCLUSIONS: The results of this study suggest that PPM has a negative long-term impact on outcomes after TAVR. These findings emphasise the importance of preventing PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Diseño de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Aórtica/cirugía , Factores de Riesgo
2.
Front Cardiovasc Med ; 10: 1320001, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38292452

RESUMEN

Introduction: Dual antithrombotic therapy (DAT) combining oral anticoagulation (OAC), preferentially Non-vitamin K antagonist OAC (NOAC) and single antiplatelet therapy (SAPT) for a period of 6-12 months is recommended after percutaneous coronary intervention (PCI) in patients with an indication for OAC. Objective: To compare outcomes between vitamin K antagonist (VKA) and NOAC-treated patients in the nation-wide France PCI registry. Methods: All consecutive patients from the France PCI registry treated by PCI and discharged with OAC between 2014 and 2020 were included and followed one-year. Major bleeding was defined as Bleeding Academic Research Consortium (BARC) classification ≥3 and major adverse cardiac events (MACE) as the composite of all-cause mortality, myocardial infarction (MI), and ischemic stroke. A propensity-score analysis was used. Results: Of the 7,277 eligible participants, 2,432 (33.4%) were discharged on VKA and 4,845 (66.6%) on NOAC. After propensity-score adjustment, one-year major bleeding was less frequent in NOAC vs. VKA-treated participants [3.1% vs. 5.2%, -2.1% (-3.6% to -0.6%), p = 0.005 as well as the rate of MACE [9.2% vs. 11.9%, -2.7% (-5.0% to -0.4%), p = 0.02]. One-year mortality was also significantly decreased in NOAC vs. VKA-treated participants [7.4% vs. 9.9%, -2.6% (-4.7% to -0.5%), p = 0.02]. The area under ROC curves of the anticoagulant treatment propensity score was estimated at 0.93, suggesting potential indication bias. Conclusions: NOAC seems to have a better efficacy and safety profile than VKA. However, potential indication bias were found.

3.
Arch Cardiovasc Dis ; 115(4): 196-205, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35559901

RESUMEN

BACKGROUND: Since the first-in-man implantation of a transcatheter aortic stented valve in April 2002 in Rouen, the procedure has expanded worldwide. In our centre, all transfemoral procedures have been performed using local anaesthesia without transoesophageal echocardiographic monitoring. AIM: To report our experience of transfemoral arterial transcatheter aortic valve implantation (TAVI) over the last 2 decades, following the evolution of devices, practices and indications. METHODS: Between 2002 and 2021, 2097 consecutive patients had a TAVI procedure in our centre. Among them, 1780 underwent transfemoral arterial aortic valve implantation, and were subdivided into three groups according to the time period: before 2009; 2009-2014; and 2014-2021. RESULTS: Median age was 85 years, and remained unchanged over time. The mean logistic EuroSCORE gradually decreased over time (28% before 2009 vs 15% for 2009-2014 vs 11% since 2014; P<0.001). Predilatation was performed almost systematically before 2009 (93%), but was rarely performed in the last period (14%; P<0.001). Thirty-day all-cause mortality decreased over time, and was only 1.4% in 2021. Length of stay decreased considerably, with a median duration of only 2 days after the procedure, and>70% of patients were discharged home within 72hours. Similarly, procedural duration, X-ray time and contrast volume decreased over time. CONCLUSION: Transfemoral aortic valve implantation, performed as a minimalist "stent-like" procedure using only local anaesthesia, is feasible in the vast majority of patients, with excellent outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Retrospectivos , Stents , Resultado del Tratamiento
4.
Eur Heart J Cardiovasc Imaging ; 23(4): 569-577, 2022 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-34008835

RESUMEN

AIMS: Although cardiac involvement has prognostic significance in coronavirus disease 2019 (COVID-19) and is associated with severe forms, few studies have explored the prognostic role of transthoracic echocardiography (TTE). We investigated the link between TTE parameters and prognosis in COVID-19. METHODS AND RESULTS: Consecutive patients with COVID-19 admitted to 24 French hospitals were retrospectively included. Comprehensive data, including clinical and biological parameters, were recorded at admission. Focused TTE was performed during hospitalization, according to clinical indication. Patients were followed for a primary composite outcome of death or transfer to intensive care unit (ICU) during hospitalization. Among 2878 patients, 445 (15%) underwent TTE. Most of these had cardiovascular risk factors, a history of cardiovascular disease, and were on cardiovascular treatments. Dilatation and dysfunction were observed in, respectively, 12% (48/412) and 23% (102/442) of patients for the left ventricle, and in 12% (47/407) and 16% (65/402) for the right ventricle (RV). Primary composite outcome occurred in 44% (n = 196) of patients [9% (n = 42) for death without ICU transfer and 35% (n = 154) for admission to ICU]. RV dilatation was the only TTE parameter associated with the primary outcome. After adjustment, male sex [hazard ratio (HR) 1.56, 95% confidence interval (CI) 1.09 - 2.25; P = 0.02], higher body mass index (HR 1.10, 95% CI 1.02 - 1.18; P = 0.01), anticoagulation (HR 0.53, 95% CI 0.33 - 0.86; P = 0.01), and RV dilatation (HR 1.66, 95% CI 1.05 - 2.64; P = 0.03) remained independently associated with the primary outcome. CONCLUSION: Echocardiographic evaluation of RV dilatation could be useful for assessing risk of severe COVID-19 developing in hospitalized patients.


Asunto(s)
COVID-19 , Disfunción Ventricular Derecha , Femenino , Humanos , Masculino , Pronóstico , Estudios Retrospectivos , SARS-CoV-2
5.
Am J Cardiol ; 161: 63-69, 2021 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-34794620

RESUMEN

Right ventricular dysfunction (RVD) is considered to be a late marker of aortic stenosis. However, there is a lack of consensus regarding the incidence, prognostic impact, and evolution of RVD in patients treated with transcatheter aortic valve implantation (TAVI). All patients treated with TAVI for severe aortic stenosis were included in a prospective single-center database. Patients who had a quantitative assessment of right ventricular (RV) function including tricuspid annular plane systolic excursion (TAPSE) and/or Doppler tissue imaging-derived tricuspid lateral annular systolic velocity (S' wave) measurements were eligible for this study. RVD was defined as TAPSE <17 mm or S' <9.5 cm/s if TAPSE was not available. Between 2014 and 2019, 503 patients with RV function assessment were included. The incidence of RVD before TAVI was 18.7%. Predictors of RVD were diabetes (p = 0.03), atrial fibrillation (p = 0.001), impaired left ventricular ejection fraction (p <0.0001), left ventricular dilatation (p = 0.007), and previous cardiac surgery (p = 0.002). Long-term survival was worse in patients with RVD before TAVI compared with those without RVD (hazard ratio 1.97, 95% confidence interval 1.1 to 3.4, p = 0.01). One year after TAVI, 58.7% of patients with baseline RVD had normal RV function and had similar outcomes as compared with those without RVD at baseline. In contrast, patients with persistent RVD had the worst prognosis. In conclusion, RVD is not rare and has a deleterious prognostic impact in patients treated with TAVI. Recovery of normal RV function is frequent after TAVI, whereas persistence of RVD is associated with poor outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Volumen Sistólico/fisiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Disfunción Ventricular Derecha/epidemiología , Función Ventricular Derecha/fisiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Estudios de Seguimiento , Francia/epidemiología , Incidencia , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Sístole , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA