Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
Am Heart J Plus ; 44: 100421, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39070127

RESUMEN

Background: Catheter ablation (CA) for ventricular tachycardia (VT) can be a useful treatment strategy, however, few studies have compared CA to medical therapy (MT) in the sarcoidosis population. Objective: To assess in-hospital outcomes and unplanned readmissions following CA for VT compared to MT in patients with sarcoidosis. Methods: Data was obtained from the Nationwide Readmissions Database between 2010 and 2019 to identify patients with sarcoidosis admitted for VT either undergoing CA or MT during elective and non-elective admission. Primary endpoints were a composite endpoint of inpatient mortality, cardiogenic shock, cardiac arrest and 30-day hospital readmissions. Procedural complications at index admission and causes of readmission were also identified. Results: Among 1581 patients, 1217 with sarcoidosis and VT underwent MT compared to 168 with CA during non-elective admission. 63 patients admitted electively underwent CA compared with 129 managed medically. There was no difference in the composite outcome for patients undergoing catheter ablation or medical therapy during both non-elective (9.0 % vs 12.0 %, p = 0.312) and elective admission (3.2 % vs. 7.8 %, p = 0.343). The most common cause of readmission were ventricular arrhythmias (VA) in both groups, however, those undergoing elective CA were less likely to be readmitted for VA compared to non-elective CA. The most common complication in the CA group was cardiac tamponade (4.8 %). Conclusion: VT ablation is associated with similar rates of 30-day readmission compared to MT and does not confer increased risk of harm with respect to inpatient mortality, cardiogenic shock or cardiac arrest. Further research is warranted to determine if a subgroup of sarcoidosis patients admitted with VT are better served with an initial conservative management strategy followed by VT ablation.

3.
J Interv Card Electrophysiol ; 67(5): 921-1072, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38609733

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Consenso , Sociedades Médicas , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Humanos , Europa (Continente) , América Latina , Asia
4.
J Interv Card Electrophysiol ; 67(4): 699-700, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38557947
5.
Heart Rhythm ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38597857

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.

6.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38587017

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , América Latina , Resultado del Tratamiento , Catéteres , Asia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
7.
Heart Rhythm ; 21(8): 1308-1316, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38490597

RESUMEN

BACKGROUND: Many patients with mildly to moderately reduced left ventricular ejection fraction (LVEF) who require permanent pacemaker (PPM) implantation do not have a concurrent indication for implantable cardioverter-defibrillator (ICD) therapy. However, the risk of ventricular tachycardia/ventricular fibrillation (VT/VF) in this population is unknown. OBJECTIVE: The aim of this study was to describe the risk of VT/VF after PPM implantation in patients with mildly to moderately reduced LVEF. METHODS: Retrospective analysis was performed of 243 patients with LVEF between 35% and 49% who underwent PPM placement and did not meet indications for an ICD. The primary end point was occurrence of sustained VT/VF. Competing risks regression was performed to calculate subhazard ratios for the primary end point. RESULTS: Median follow-up was 27 months; 73% of patients were male, average age was 79 ± 10 years, average LVEF was 42% ± 4%, and 70% were New York Heart Association class II or above. Most PPMs were implanted for sick sinus syndrome (34%) or atrioventricular block (50%). Of 243 total patients, 11 (4.5%) met the primary end point of VT/VF. Multivessel coronary artery disease (CAD) was associated with significantly higher rates of VT/VF, with a subhazard ratio of 5.4 (95% CI, 1.5-20.1; P = .01). Of patients with multivessel CAD, 8 of 82 (9.8%) patients met the primary end point for an annualized risk of 4.3% per year. CONCLUSION: Patients with mildly to moderately reduced LVEF and multivessel CAD undergoing PPM implantation are at increased risk for the development of malignant ventricular arrhythmias. Patients in this population may benefit from additional risk stratification for VT/VF and consideration for upfront ICD implantation.


Asunto(s)
Marcapaso Artificial , Volumen Sistólico , Taquicardia Ventricular , Humanos , Masculino , Femenino , Volumen Sistólico/fisiología , Anciano , Estudios Retrospectivos , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Estudios de Seguimiento , Medición de Riesgo/métodos , Factores de Riesgo , Desfibriladores Implantables , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Función Ventricular Izquierda/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/terapia
9.
J Interv Card Electrophysiol ; 67(1): 203-210, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36952090

RESUMEN

OBJECTIVES: We investigated characteristics of left atrial conduction in patients with HCM, paroxysmal AF and normal bipolar voltage. BACKGROUND: Patients with hypertrophic cardiomyopathy (HCM) exhibit abnormal cardiac tissue arrangement. The incidence of atrial fibrillation (AF) is increased fourfold in patients with HCM and confers a fourfold increased risk of death. Catheter ablation is less effective in HCM, with twofold increased risk of AF recurrence. The mechanisms of AF perpetuation in HCM are poorly understood. METHODS: We analyzed 20 patients with HCM and 20 controls presenting for radiofrequency ablation of paroxysmal AF normal left atrial voltage(> 0.5 mV). Intracardiac electrograms were extracted from the CARTO mapping system and analyzed using Matlab/Python code interfacing with Core OpenEP software. Conduction velocity maps were calculated using local activation time gradients. RESULTS: There were no differences in baseline demographics, atrial size, or valvular disease between HCM and control patients. Patients with HCM had significantly reduced atrial conduction velocity compared to controls (0.44 ± 0.17 vs 0.56 ± 0.10 m/s, p = 0.01), despite no significant differences in bipolar voltage amplitude (1.23 ± 0.38 vs 1.20 ± 0.41 mV, p = 0.76). There was a statistically significant reduction in conduction velocity in the posterior left atrium in HCM patients relative to controls (0.43 ± 0.18 vs 0.58 ± 0.10 m/s, p = 0.003), but not in the anterior left atrium (0.46 ± 0.17 vs 0.55 ± 0.10 m/s, p = 0.05). There was a significant association between conduction velocity and interventricular septal thickness (slope = -0.013, R2 = 0.13, p = 0.03). CONCLUSIONS: Atrial conduction velocity is significantly reduced in patients with HCM and paroxysmal AF, possibly contributing to arrhythmia persistence after catheter ablation.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cardiomiopatía Hipertrófica , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/cirugía , Cardiomiopatía Hipertrófica/complicaciones , Apéndice Atrial/cirugía , Ablación por Catéter/efectos adversos
11.
Adv Radiat Oncol ; 8(6): 101272, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37415904

RESUMEN

Purpose: Cardiac radioablation is an emerging therapy for recurrent ventricular tachycardia. Electrophysiology (EP) data, including electroanatomic maps (EAM) and electrocardiographic imaging (ECGI), provide crucial information for defining the arrhythmogenic target volume. The absence of standardized workflows and software tools to integrate the EP maps into a radiation planning system limits their use. This study developed a comprehensive software tool to enable efficient utilization of the mapping for cardiac radioablation treatment planning. Methods and Materials: The tool, HeaRTmap, is a Python-scripted plug-in module on the open-source 3D Slicer software platform. HeaRTmap is able to import EAM and ECGI data and visualize the maps in 3D Slicer. The EAM is translated into a 3D space by registration with cardiac magnetic resonance images (MRI) or computed tomography (CT). After the scar area is outlined on the mapping surface, the tool extracts and extends the annotated patch into a closed surface and converts it into a structure set associated with the anatomic images. The tool then exports the structure set and the images as The Digital Imaging and Communications in Medicine Standard in Radiotherapy for a radiation treatment planning system to import. Overlapping the scar structure on simulation CT, a transmural target volume is delineated for treatment planning. Results: The tool has been used to transfer Ensite NavX EAM data into the Varian Eclipse treatment planning system in radioablation on 2 patients with ventricular tachycardia. The ECGI data from CardioInsight was retrospectively evaluated using the tool to derive the target volume for a patient with left ventricular assist device, showing volumetric matching with the clinically used target with a Dice coefficient of 0.71. Conclusions: HeaRTmap smoothly fuses EP information from different mapping systems with simulation CT for accurate definition of radiation target volume. The efficient integration of EP data into treatment planning potentially facilitates the study and adoption of the technique.

16.
Heart Rhythm ; 20(6): 808-814, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36863636

RESUMEN

BACKGROUND: Established electroanatomic mapping techniques for substrate mapping for ventricular tachycardia (VT) ablation includes voltage mapping, isochronal late activation mapping (ILAM), and fractionation mapping. Omnipolar mapping (Abbott Medical, Inc.) is a novel optimized bipolar electrogram creation technique with integrated local conduction velocity annotation. The relative utilities of these mapping techniques are unknown. OBJECTIVE: The purpose of this study was to evaluate the relative utility of various substrate mapping techniques for the identification of critical sites for VT ablation. METHODS: Electroanatomic substrate maps were created and retrospectively analyzed in 27 patients in whom 33 VT critical sites were identified. RESULTS: Both abnormal bipolar voltage and omnipolar voltage encompassed all critical sites and were observed over a median of 66 cm2 (interquartile range [IQR] 41.3-86 cm2) and 52 cm2 (IQR 37.7-65.5 cm2), respectively. ILAM deceleration zones were observed over a median of 9 cm2 (IQR 5.0-11.1 cm2) and encompassed 22 critical sites (67%), while abnormal omnipolar conduction velocity (CV <1 mm/ms) was observed over 10 cm2 (IQR 5.3-16.6 cm2) and identified 22 critical sites (67%), and fractionation mapping was observed over a median of 4 cm2 (IQR 1.5-7.6 cm2) and encompassed 20 critical sites (61%). The mapping yield was the highest for fractionation + CV (2.1 critical sites/cm2) and least for bipolar voltage mapping (0.5 critical sites/cm2). CV identified 100% of critical sites in areas with a local point density of >50 points/cm2. CONCLUSION: ILAM, fractionation, and CV mapping each identified distinct critical sites and provided a smaller area of interest than did voltage mapping alone. The sensitivity of novel mapping modalities improved with greater local point density.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Estudios Retrospectivos , Técnicas Electrofisiológicas Cardíacas/métodos , Ablación por Catéter/métodos
17.
J Cardiovasc Electrophysiol ; 34(4): 942-946, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36738141

RESUMEN

INTRODUCTION: Radiofrequency ablation (RFA) slow pathway modification for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is traditionally performed using a 4-mm nonirrigated (NI) RF ablation catheter. Slow pathway modification using irrigated, contact-force sensing (ICFS) RFA catheters has been described in case reports, but the outcomes have not been systematically evaluated. METHODS: Acute procedural outcomes of 200 consecutive patients undergoing slow pathway modification for AVNRT were analyzed. A 3.5-mm ICFS RFA catheter (ThermoCool SmartTouch STSF, Biosense Webster, Inc.) was utilized in 134 patients, and a 4-mm NI RFA catheter (EZ Steer, Biosense Webster, Inc.) was utilized in 66 patients. Electroanatomic maps were retrospectively analyzed in a blinded fashion to determine the proximity of ablation lesions to the His region. RESULTS: The baseline characteristics of patients in both groups were similar. Total RF time was significantly lower in the ICFS group compared to the NI group (5.53 ± 4.6 vs. 6.24 ± 4.9 min, p = 0.03). Median procedure time was similar in both groups (ICFS, 108.0 (87.5-131.5) min vs. NI, 100.0 (85.0-125.0) min; p = 0.2). Ablation was required in closer proximity to the His region in the NI group compared to the ICFS group (14.4 ± 5.9 vs. 16.7 ± 6.4 mm, respectively, p = 0.01). AVNRT was rendered noninducible in all patients, and there was no arrhythmia recurrence during follow-up in both groups. Catheter ablation was complicated by AV block in one patient in the NI group. CONCLUSION: Slow pathway modification for catheter ablation of AVNRT using an ICFS RFA catheter is feasible, safe, and may facilitate shorter duration ablation while avoiding ablation in close proximity to the His region.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Estudios Retrospectivos , Catéteres
18.
J Cardiovasc Electrophysiol ; 34(4): 800-807, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36738147

RESUMEN

INTRODUCTION: Radiofrequency ablation technology for treating atrial fibrillation (AF) has evolved rapidly over the past decade. We investigated the impact of technological and procedural advances on procedure times and ablation outcomes at a major academic medical center over a 10-year period. METHODS: Clinical data was collected from patients who presented to NYU Langone Health between 2011 and 2021 for a first-time AF ablation. Time to redo AF ablation or direct current cardioversion (DCCV) for recurrent AF during a 3-year follow-up period was determined and correlated with ablation technology and practices, antiarrhythmic medications, and patient comorbid conditions. RESULTS: From 2011 to 2021, the cardiac electrophysiology lab adopted irrigated-contact force ablation catheters, high-power short duration ablation lesions, steady-pacing, jet ventilation, and eliminated stepwise linear ablation for AF ablation. During this time the number of first time AF ablations increased from 403 to 1074, the percentage of patients requiring repeat AF-related intervention within 3-years of the index procedure dropped from 22% to 14%, mean procedure time decreased from 271 ± 65 to 135 ± 36 min, and mean annual major adverse event rate remained constant at 1.1 ± 0.5%. Patient comorbid conditions increased during this time period and antiarrhythmic use was unchanged. CONCLUSION: Rates of redo-AF ablation or DCCV following an initial AF ablation at a single center decreased 36% over a 10-year period. Procedural and technological changes likely contributed to this improvement, despite increased AF related comorbidities.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Antiarrítmicos/uso terapéutico , Factores de Tiempo , Ablación por Catéter/métodos
19.
Int J Cardiovasc Imaging ; 39(1): 145-152, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36598692

RESUMEN

Although PVCs commonly lead to degraded cine cardiac MRI (CMR), patients with PVCs may have relatively sharp cine images of both normal and ectopic beats ("double beats") when the rhythm during CMR is ventricular bigeminy, and only one beat of the pair is detected for gating. MRI methods for directly imaging premature ventricular contractions (PVCs) are not yet widely available. Localization of PVC site of origin with images may be helpful in planning ablations. The contraction pattern of the PVCs in bigeminy provides a "natural experiment" for investigating the potential utility of PVC imaging for localization. The purpose of this study was to evaluate the correlation of the visually assessed site of the initial contraction of the ectopic beats with the site of origin found by electroanatomic mapping. Images from 7 of 86 consecutive patients who underwent CMR prior to PVC ablation were found to include clear cine images of bigeminy. The visually apparent site of origin of the ectopic contraction was determined by three experienced, blinded CMR readers and correlated with each other, and with PVC site of origin determined by 3D electroanatomic mapping during catheter ablation. Blinded ascertainment of visually apparent initial contraction pattern for PVC localization was within 2 wall segments of PVC origin by 3D electroanatomic mapping 76% of the time. Our data from patients with PVCs with clear images of the ectopic beats when in bigeminy provide proof-of-concept that CMR ectopic beat contraction patterns analysis may provide a novel method for localizing PVC origin prior to ablation procedures. Direct imaging of PVCs with use of newer cardiac imaging methods, even without the presence of bigeminy, may thus provide valuable data for procedural planning.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Humanos , Complejos Prematuros Ventriculares/diagnóstico por imagen , Complejos Prematuros Ventriculares/cirugía , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Ablación por Catéter/métodos , Electrofisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA