Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
J Med Biochem ; 41(1): 115-121, 2022 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-35431650

RESUMEN

Background: von Willebrand factor (VWF) multimers (VWF:MM) methodologies are technically difficult, laborious, time consuming, non-standardized and results vary between laboratories. A new semi automated VWF:MM assay is available for routine use (Sebia). Due to lack of reference values for VWF:MM fractions, results interpretation can be challenging in some cases. The aim of this study was to determine reference intervals for low molecular weight (LMWM), intermediate molecular weight (IMWM) and high molecular weight (HMWM) multimers. Methods: By the international cooperation initiated between 4 countries (Estonia, Latvia, France, and USA) 131 samples of relatively healthy individuals were analyzed for VWF:MM (in total 51 males and 80 non-pregnant females aged 17-69 years). Reference intervals were calculated according to CLSI C28-A3 standard. Results: The proposed reference intervals for VWF:MM were calculated for LMWM 10.4-22.5%, IMWM 22.6-37.6%, HMWM 45.6-66.6%. Age related differences were seen in IMWM and HMWM (p<0.001 and 0.038). There was no gender related difference observed. Geographically LMWM results of France were different from the other regions (p<0.05). Conclusions: Quantification of VWF:MM fractions, in addition to qualitative assessment of VWF:MM patterns, has the potential to aid in differential diagnosis of von Willebrand disease (VWD) subtypes. The reference values calculated in this study can be used in future research to establish clinical decision limits.

2.
J Clin Lab Anal ; 32(6): e22416, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29453814

RESUMEN

BACKGROUND: The von Willebrand factor (VWF) multimer test is required to correctly subtype qualitative type 2 von Willebrand disease (VWD). The current VWF multimer assays are difficult, nonstandardized, and time-consuming. The purpose of this study was to evaluate the clinical utility of the commercial VWF multimer kit by Sebia (Lisses, France), an electrophoresis technique yielding same-day results. METHODS: Ten healthy volunteer plasma samples, in-house reference plasma (IRP) and commercial normal plasma (CNP) samples, 10 plasma samples from patients with a known VWD type, 1 hemophilia A plasma sample, and 7 external quality assurance (EQA) samples were analyzed using the commercial VWF multimer kit. Additional coagulation testing included measurements of VWF antigen (VWF:Ag), VWF activity (VWF:Ac), and FVIII activity (FVIII:C). RESULTS: The CNP results revealed a relative loss of the highest molecular weight multimers; therefore, IRP was preferred as the reference sample. The interpretations of 10 patients with a known VWD type could be successfully reproduced and agreed with previous VWF multimer results. In all EQA surveys, the multimer results and final VWD diagnosis agreed with expert opinion. CONCLUSIONS: The VWF multimer assay by Sebia is easy to perform and can be successfully implemented in any clinical laboratory for second-stage evaluation of VWD. The resolution power of multimer distribution is adequate to correctly classify VWD types 1, 2A, 2B, and 3.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA