1.
Appl Radiat Isot ; 166: 109363, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32877863

RESUMEN

The E_LIBANS project (INFN) aims at producing neutron facilities for interdisciplinary irradiation purposes among which pre-clinical research for BNCT. After the successful setting-up of the thermal neutron source based on a medical LINAC, a similar apparatus for epithermal neutrons has been developed. Both structures are based on an Elekta 18 MV coupled with a photoconverter-moderator system which deploys the (γ,n) reaction to convert the X-rays into neutrons. This communication describes the two neutron sources and the results obtained in their characterization.


Asunto(s)
Terapia por Captura de Neutrón de Boro/instrumentación , Neutrones , Aceleradores de Partículas/instrumentación , Animales , Terapia por Captura de Neutrón de Boro/estadística & datos numéricos , Simulación por Computador , Diseño de Equipo , Humanos , Italia
2.
Appl Radiat Isot ; 142: 38-41, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30248587

RESUMEN

CSYP (CYlindrical SPectrometer) is a directional neutron spectrometer based on a single moderator embedding multiple thermal neutron detectors. Similarly to Bonner Spheres, CYSP responds from thermal up to GeV neutrons and the spectrum is obtained via few-channel unfolding methods. CYSP has the shape of a polyethylene cylinder with diameter 50 cm and height 65 cm. Owing on a thick collimator and on a specifically designed shielding structure, the internal detectors only respond to neutrons coming from a known direction. Internal thermal neutron detectors are one-cm2 6LiF-covered silicon diodes. Un upgraded version of CYPS was developed to work in low intensity applications, such as cosmic field measurements. It is called CYSP-HS (High-Sensitivity) and is equipped with large area 6LiF-covered silicon diodes (LATND, Large Area Thermal Neutron Detectors). Compared with the former CYSP, the sensitivity increased approximately by an order of magnitude. This paper presents CYSP-HS focusing on the new internal detectors, the response matrix and its verification in a reference field of Am-Be available at the Politecnico di Milano.

3.
Radiat Prot Dosimetry ; 180(1-4): 70-74, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29385623

RESUMEN

This article describes the purpose, the proposed problems and the reference solutions of an international comparison on neutron spectra unfolding in Bonner spheres spectrometry, organised within the activities of EURADOS working group 6: computational dosimetry. The exercise considered four realistic situations: a medical accelerator, a workplace field, an irradiation room and a skyshine scenario. Although a detailed analysis of the submitted solutions is under preparation, the preliminary discussion of some physical aspects of the problem, e.g. the changes in the unfolding results due to the perturbation of the neutron field by the Bonner spheres, is presented.


Asunto(s)
Neutrones , Monitoreo de Radiación/instrumentación , Monitoreo de Radiación/métodos , Protección Radiológica/instrumentación , Simulación por Computador , Diseño de Equipo , Dosis de Radiación
4.
Radiat Prot Dosimetry ; 180(1-4): 273-277, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29309701

RESUMEN

The e_LiBANS project aims at producing intense thermal neutron fields for diverse interdisciplinary irradiation purposes. It makes use of a reconditioned medical electron LINAC, recently installed at the Physics Department and INFN in Torino, coupled to a dedicated photo-converter, developed within this collaboration, that uses (γ,n) reaction within high Z targets. Produced neutrons are then moderated to thermal energies and concentrated in an irradiation volume. To measure and to characterize in real time the intense field inside the cavity new thermal neutron detectors were designed with high radiation resistance, low noise and very high neutron-to-photon discrimination capability. This article offers an overview of the e_LiBANS project and describes the results of the benchmark experiment.


Asunto(s)
Neutrones , Aceleradores de Partículas , Fotones , Dosis de Radiación , Radiometría/instrumentación , Electrones , Diseño de Equipo , Rayos gamma , Investigación Interdisciplinaria , Modelos Lineales
5.
Radiat Prot Dosimetry ; 180(1-4): 304-308, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29361156

RESUMEN

Radiation-resistant, gamma-insensitive, active thermal neutron detectors were developed to monitor the thermal neutron cavity of the E_LIBANS project. Silicon and silicon carbide semiconductors, plus vented air ion chambers, were chosen for this purpose. This communication describes the performance of these detectors, owing on the results of dedicated measurement campaigns.


Asunto(s)
Compuestos Inorgánicos de Carbono/química , Neutrones , Monitoreo de Radiación/instrumentación , Monitoreo de Radiación/métodos , Protección Radiológica/instrumentación , Semiconductores/normas , Compuestos de Silicona/química , Silicio/química , Simulación por Computador , Diseño de Equipo , Dosis de Radiación , Temperatura
6.
Appl Radiat Isot ; 127: 68-72, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28527348

RESUMEN

HOTNES (HOmogeneous Thermal NEutron Source) is a thermal neutron irradiation facility with extended and very uniform irradiation area. A 241Am-B radionuclide neutron source with nominal strenght 3.5×106 s-1 is located on bottom of a large cylindrical cavity (30cm diameter, 70cm in height) delimited by polyethylene walls. The upper part of this volume (30cm diameter, 40cm in height) is used to irradiate samples. A polyethylene cylinder, acting as shadowing object, prevents fast neutrons to directly reach the irradiation volume. Indeed neutrons can only reach the irradiation volume after multiple scattering with the cavity walls. The facility was designed trough extensive calculations with MCNPX. Irradiation planes are disks with 30cm diameter, centred on the cavity axis, and parallel to the cavity bottom. The value of thermal fluence in a given irradiation plane is as uniform as 1-2%. The value of thermal fluence rate simply depends on the height from the cavity bottom. Values of thermal fluence rate in the range 700-1000cm-2s-1 are available, depending on the irradiation plane chosen. The fraction of thermal neutrons is in the order of 90%, also depending on the irradiation plane. The angular distribution of thermal neutrons is roughly isotropic. Taking advantage of the HOTNES design, even large devices can be uniformly irradiated. This work presents HOTNES's design and describes the neutron field in the irradiation volume in terms of spatial, energy and direction distributions.

7.
Appl Radiat Isot ; 123: 32-35, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28214683

RESUMEN

One of the major causes of secondary malignancies after radiotherapy treatments are peripheral doses, known to increase for some newer techniques (such as IMRT or VMAT). For accelerators operating above 10MV, neutrons can represent important contribution to peripheral doses. This neutron contamination can be measured using different passive or active techniques, available in the literature. As far as active (or direct-reading) procedures are concerned, a major issue is represented by their parasitic photon sensitivity, which can significantly affect the measurement when the point of test is located near to the field-edge. This work proposes a simple method to estimate the unwanted photon contribution to these neutrons. As a relevant case study, the use of a recently neutron sensor for "in-phantom" measurements in high-energy machines was considered. The method, called "Dual Energy Photon Subtraction" (DEPS), requires pairs of measurements performed for the same treatment, in low-energy (6MV) and high energy (e.g. 15MV) fields. It assumes that the peripheral photon dose (PPD) at a fixed point in a phantom, normalized to the unit photon dose at the isocenter, does not depend on the treatment energy. Measurements with ionization chamber and Monte Carlo simulations were used to evaluate the validity of this hypothesis. DEPS method was compared to already published correction methods, such as the use of neutron absorber materials. In addition to its simplicity, an advantage of DEPs procedure is that it can be applied to any radiotherapy machine.


Asunto(s)
Neutrones Rápidos , Fotones , Radiometría/métodos , Dosificación Radioterapéutica , Simulación por Computador , Neutrones Rápidos/efectos adversos , Humanos , Método de Montecarlo , Neoplasias Inducidas por Radiación/etiología , Neoplasias Primarias Secundarias/etiología , Fantasmas de Imagen , Fotones/efectos adversos , Radiometría/instrumentación , Radiometría/estadística & datos numéricos , Radioterapia de Intensidad Modulada/efectos adversos , Dispersión de Radiación
8.
Radiat Prot Dosimetry ; 173(1-3): 104-110, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28100670

RESUMEN

This communication describes two new instruments, based on multiple active thermal neutron detectors arranged within a single moderator, that permit to unfold the neutron spectrum (from thermal to hundreds of MeV) and to determine the corresponding integral quantities with only one exposure. This makes them especially advantageous for neutron field characterisation and workplace monitoring in neutron-producing facilities. One of the devices has spherical geometry and nearly isotropic response, the other one has cylindrical symmetry and it is only sensitive to neutrons incident along the cylinder axis. In both cases, active detectors have been specifically developed looking for the criteria of miniaturisation, high sensitivity, linear response and good photon rejection. The calculated response matrix has been validated by experimental irradiations in neutron reference fields with a global uncertainty of 3%. The measurements performed in realistic neutron fields permitted to determine the neutron spectra and the integral quantities, in particular H*(10).


Asunto(s)
Monitoreo de Radiación , Protección Radiológica , Lugar de Trabajo , Diseño de Equipo , Humanos , Neutrones , Fotones , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Appl Radiat Isot ; 115: 49-54, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27337649

RESUMEN

The increasing interest of the medical community to radioinduced second malignancies due to photoneutrons in patients undergoing high-energy radiotherapy, has stimulated in recent years the study of peripheral doses, including the development of some dedicated active detectors. Although these devices are designed to respond to neutrons only, their parasitic photon response is usually not identically zero and anisotropic. The impact of these facts on measurement accuracy can be important, especially in points close to the photon field-edge. A simple method to estimate the photon contribution to detector readings is to cover it with a thermal neutron absorber with reduced secondary photon emission, such as a borated rubber. This technique was applied to the TNRD (Thermal Neutron Rate Detector), recently validated for thermal neutron measurements in high-energy photon radiotherapy. The positive results, together with the accessibility of the method, encourage its application to other detectors and different clinical scenarios.


Asunto(s)
Neutrones , Radiometría , Radioterapia de Alta Energía , Humanos , Fotones
10.
Radiat Prot Dosimetry ; 170(1-4): 326-30, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26276808

RESUMEN

This communication describes a recently developed single-exposure neutron spectrometer, based on multiple active thermal neutron detectors located within a moderating sphere, which have been developed jointly by CIEMAT (Spain), INFN (Italy) and Politecnico di Milano (Italy) in the framework of Italian and Spanish collaboration projects. The fabricated prototypes permit to achieve spectrometric resolution with nearly isotropic response for neutron with energies from thermal to 100-200 MeV, thus being able to characterise the complete neutron spectrum in only one exposure by unfolding the measured responses of the detectors. This makes it especially advantageous for characterising neutron fields and workplace monitoring purposes in neutron-producing facilities.


Asunto(s)
Exposición Profesional/análisis , Dosis de Radiación , Dosímetros de Radiación , Monitoreo de Radiación/instrumentación , Protección Radiológica/instrumentación , Análisis Espectral/instrumentación , Calibración , Humanos , Italia , Neutrones , Exposición Profesional/prevención & control , Fotones , Polietileno , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Reproducibilidad de los Resultados , España , Lugar de Trabajo
11.
Appl Radiat Isot ; 107: 171-176, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26516990

RESUMEN

A new thermal neutron irradiation facility based on an (241)Am-Be source embedded in a polyethylene moderator has been designed, and is called ETHERNES (Extended THERmal NEutron Source). The facility shows a large irradiation cavity (45 cm × 45 cm square section, 63 cm in height), which is separated from the source by means of a polyethylene sphere acting as shadowing object. Taking advantage of multiple scattering of neutrons with the walls of this cavity, the moderation process is especially effective and allows obtaining useful thermal fluence rates from 550 to 800 cm(-2) s(-1) with a source having nominal emission rate 5.7×10(6) s(-1). Irradiation planes parallel to the cavity bottom have been identified. The fluence rate across a given plane is as uniform as 3% (or better) in a disk with 30 cm (or higher) diameter. In practice, the value of thermal fluence rate simply depends on the height from the cavity bottom. The thermal neutron spectral fraction ranges from 77% up to 89%, depending on the irradiation plane. The angular distribution of thermal neutrons is roughly isotropic, with a slight prevalence of directions from bottom to top of the cavity. The mentioned characteristics are expected to be attractive for the scientific community involved in neutron metrology, neutron dosimetry and neutron detector testing.

12.
Appl Radiat Isot ; 107: 330-334, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26595777

RESUMEN

Active thermal neutron detectors are used in a wide range of measuring devices in medicine, industry and research. For many applications, the long-term stability of these devices is crucial, so that very well controlled neutron fields are needed to perform calibrations and repeatability tests. A way to achieve such reference neutron fields, relying on a 3 MV Tandem Pelletron accelerator available at the CNA (Seville, Spain), is reported here. This paper shows thermal neutron field production and reproducibility characteristics over few days.


Asunto(s)
Neutrones , Aceleradores de Partículas , Calibración , Diseño de Equipo , Humanos , Radiometría/instrumentación , Radiometría/estadística & datos numéricos , Reproducibilidad de los Resultados , España
13.
Med Phys ; 41(11): 112105, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25370656

RESUMEN

PURPOSE: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. METHODS: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. RESULTS: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. CONCLUSIONS: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an easy implementation of specific peripheral neutron dose models for any type of treatment and facility.


Asunto(s)
Neutrones , Radiometría/instrumentación , Radiometría/métodos , Radioterapia/métodos , Antropometría , Calibración , Estudios de Cohortes , Diseño de Equipo , Humanos , Modelos Estadísticos , Neoplasias/diagnóstico , Neoplasias/diagnóstico por imagen , Neoplasias/radioterapia , Fantasmas de Imagen , Dosis de Radiación , Radiografía , Dosificación Radioterapéutica , Análisis de Regresión , Reproducibilidad de los Resultados , Medición de Riesgo
14.
Radiat Prot Dosimetry ; 161(1-4): 46-52, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24442664

RESUMEN

This work compares the results of four different unfolding codes, MSANDB, MAXED, FRUIT and BONMA, which are based on different unfolding techniques. Additionally, Bayesian parameter estimation is also considered. All unfolding codes were supplied with the same set of input data acquired at the Environmental Research Station 'Schneefernerhaus' on the Zugspitze mountain, corresponding to continuous measurements of secondary neutrons from cosmic radiation. The HMGU high-energy extended Bonner sphere spectrometer (BSS), consisting of 16 measuring channels with (3)He proportional counters, was used as a reference BSS. The differences in the neutron spectra obtained with the different unfolding codes are discussed, and the uncertainties of integral quantities, like neutron fluence and ambient dose equivalent, are quantified.


Asunto(s)
Neutrones , Espectrofotometría/métodos , Algoritmos , Teorema de Bayes , Radiación Cósmica , Dosis de Radiación , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Programas Informáticos
15.
Radiat Prot Dosimetry ; 161(1-4): 37-40, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24255174

RESUMEN

NESCOFI@BTF is a 3-y project (2011-13) supported by the Scientific Commission 5 of INFN (Italy). The target is the development of neutron spectrometers similar to the Bonner spheres, in terms of response energy interval and accuracy, but able to determine the neutron spectrum in only one exposure. These devices embed multiple (10 to 30) thermal neutron detectors (TNDs) within a single moderator. Two prototypes, called SPherical SPectrometer (SP(2)) and cylindrical spectrometer (CYSP), have been set up. Whilst SP(2) has spherical geometry and nearly isotropic response, the CYSP has cylindrical geometry and is intended to be used as a directional spectrometer. Suitable active TNDs will be embedded in the final version of the devices. The resulting instruments could be used as real-time neutron spectrometers in neutron-producing facilities. This communication describes the design criteria, numerical analysis, experimental issues, state-of-the-art and future developments connected with the development of these instruments.


Asunto(s)
Neutrones , Espectrofotometría/instrumentación , Espectrofotometría/métodos , Diseño de Equipo , Italia , Método de Montecarlo , Polietileno/química , Desarrollo de Programa , Dosis de Radiación , Monitoreo de Radiación/instrumentación , Protección Radiológica/métodos , Reproducibilidad de los Resultados
16.
Radiat Prot Dosimetry ; 161(1-4): 229-32, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24277874

RESUMEN

In the framework of the NESCOFI@BTF project of the Italian Institute of Nuclear Physics, different types of active thermal neutron sensors were studied by coupling semiconductor devices with a suitable radiator. The objective was to develop a detector of small dimensions with a proper sensitivity to use at different positions in a novel moderating assembly for neutron spectrometry. This work discusses the experimental activity carried out in the framework of the ERINDA program (PAC 3/9 2012) to characterise the performance of a thermal neutron pulse detector based on (6)Li.


Asunto(s)
Neutrones , Radiometría/instrumentación , Espectrofotometría/métodos , Aceleración , Berilio/química , Diseño de Equipo , Italia , Litio/química , Fotones , Protones , Radiometría/métodos , Reproducibilidad de los Resultados , Conteo por Cintilación , Semiconductores , Espectrofotometría/instrumentación , Temperatura
17.
Radiat Prot Dosimetry ; 161(1-4): 241-4, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24345462

RESUMEN

This communication presents the main results about the design and in-house fabrication of a new solid-state neutron detector, which produces a DC output signal proportional to the thermal neutron fluence rate. The detector has been developed within the framework of the 3-y project NESCOFI@BTF of INFN (CSN V). Due to its sensitivity, photon rejection, low cost and minimum size, this device is suited to be used in moderator-based spectrometers.


Asunto(s)
Neutrones , Radiometría/instrumentación , Espectrofotometría/métodos , Algoritmos , Cesio , Simulación por Computador , Diseño de Equipo , Calor , Miniaturización , Método de Montecarlo , Fotones , Radiometría/métodos , Reproducibilidad de los Resultados
18.
Phys Med Biol ; 57(19): 6167-91, 2012 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-22971664

RESUMEN

Neutron peripheral contamination in patients undergoing high-energy photon radiotherapy is considered as a risk factor for secondary cancer induction. Organ-specific neutron-equivalent dose estimation is therefore essential for a reasonable assessment of these associated risks. This work aimed to develop a method to estimate neutron-equivalent doses in multiple organs of radiotherapy patients. The method involved the convolution, at 16 reference points in an anthropomorphic phantom, of the normalized Monte Carlo neutron fluence energy spectra with the kerma and energy-dependent radiation weighting factor. This was then scaled with the total neutron fluence measured with passive detectors, at the same reference points, in order to obtain the equivalent doses in organs. The latter were correlated with the readings of a neutron digital detector located inside the treatment room during phantom irradiation. This digital detector, designed and developed by our group, integrates the thermal neutron fluence. The correlation model, applied to the digital detector readings during patient irradiation, enables the online estimation of neutron-equivalent doses in organs. The model takes into account the specific irradiation site, the field parameters (energy, field size, angle incidence, etc) and the installation (linac and bunker geometry). This method, which is suitable for routine clinical use, will help to systematically generate the dosimetric data essential for the improvement of current risk-estimation models.


Asunto(s)
Neutrones/efectos adversos , Sistemas en Línea , Órganos en Riesgo/efectos de la radiación , Dosis de Radiación , Radioterapia Asistida por Computador/efectos adversos , Radioterapia Asistida por Computador/instrumentación , Aceleración , Humanos , Método de Montecarlo , Fantasmas de Imagen , Terapia de Protones/efectos adversos , Terapia de Protones/instrumentación , Dosificación Radioterapéutica
19.
Sci Rep ; 1: 91, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22355609

RESUMEN

Prompt γ-ray emissions from gamma-ray bursts (GRBs) exhibit a vast range of extremely complex temporal structures with a typical variability time-scale significantly short - as fast as milliseconds. This work aims to investigate the apparent randomness of the GRB time profiles making extensive use of nonlinear techniques combining the advanced spectral method of the Singular Spectrum Analysis (SSA) with the classical tools provided by the Chaos Theory. Despite their morphological complexity, we detect evidence of a non stochastic short-term variability during the overall burst duration - seemingly consistent with a chaotic behavior. The phase space portrait of such variability shows the existence of a well-defined strange attractor underlying the erratic prompt emission structures. This scenario can shed new light on the ultra-relativistic processes believed to take place in GRB explosions and usually associated with the birth of a fast-spinning magnetar or accretion of matter onto a newly formed black hole.


Asunto(s)
Rayos gamma , Dinámicas no Lineales , Análisis Espectral
20.
Radiat Prot Dosimetry ; 131(1): 7-14, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18782783

RESUMEN

Within the scope of CONRAD (A Coordinated Action for Radiation Dosimetry) Work Package 4 on Computational Dosimetry jointly collaborated with the other research actions on internal dosimetry, complex mixed radiation fields at workplaces and medical staff dosimetry. Besides these collaborative actions, WP4 promoted an international comparison on eight problems with their associated experimental data. A first set of three problems, the results of which are herewith summarised, dealt only with the expression of the stochastic uncertainties of the results: the analysis of the response function of a proton recoil telescope detector, the study of a Bonner sphere neutron spectrometer and the analysis of the neutron spectrum and dosimetric quantity H(p)(10) in a thermal neutron facility operated by IRSN Cadarache (the SIGMA facility). A second paper will summarise the results of the other five problems which dealt with the full uncertainty budget estimate. A third paper will present the results of a comparison on in vivo measurements of the (241)Am bone-seeker nuclide distributed in the knee. All the detailed papers will be presented in the WP4 Final Workshop Proceedings.


Asunto(s)
Radiometría , Radioterapia Asistida por Computador , Humanos , Modelos Teóricos , Neutrones , Protones , Radiometría/instrumentación , Radioterapia Asistida por Computador/instrumentación , Procesos Estocásticos