Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
2.
J Clin Med ; 13(19)2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39407972

RESUMEN

Currently, pulmonary vein isolation (PVI) is the gold standard in catheter ablation for atrial fibrillation (AF). However, PVI alone may be insufficient in the management of persistent AF, and complementary methods are being explored. One such method takes an anatomical approach-improving both its success rate and lesion durability may lead to improved treatment outcomes. An additional approach complementary to the anatomical one is also attracting attention, one that focuses on epicardial conduction. This involves ethanol ablation of the vein of Marshall (VOM) and can be very effective in blocking epicardial conduction related to Marshall structure; it is becoming incorporated into standard treatment. However, the pitfall of this "Marshall-PLAN", a method that combines an anatomical approach with ethanol infusion within the VOM (Et-VOM), is that Et-VOM and other line creations are not always successfully completed. This has led to cases of AF and/or atrial tachycardia (AT) recurrence even after completing this lesion set. Investigating effective adjunctive methods will enable us to complete the lesion set with the aim to lower the rates of recurrence of AF and/or AT in the future.

3.
Eur Heart J ; 2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39299922

RESUMEN

BACKGROUND AND AIMS: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90 days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e. within 3 months of hospital discharge) has not yet been specifically evaluated in post-myocardial infarction patients with impaired LVEF. Such was the aim of this retrospective study. METHODS: Data analysis was based on a nationwide registry of 1032 consecutive patients with LVEF ≤ 35% after acute myocardial infarction who were implanted with an ICD after being prescribed a wearable cardioverter-defibrillator (WCD) for a period of 3 months upon discharge from hospital after the index infarction. RESULTS: ICDs were implanted either because a sustained VA occurred while on WCD (VA+/WCD, n = 72) or because LVEF remained ≤35% at the end of the early post-infarction phase (VA-/WCD, n = 960). The median follow-up was 30.9 months. Sustained VAs occurred within 1 year after ICD implantation in 22.2% and 3.5% of VA+/WCD and VA-/WCD patients, respectively (P < .0001). The adjusted multivariable analysis showed that sustained VAs while on WCD independently predicted recurrence of sustained VAs at 1 year (adjusted hazard ratio [HR] 6.91; 95% confidence interval [CI] 3.73-12.81; P < .0001) and at the end of follow-up (adjusted HR 3.86; 95% CI 2.37-6.30; P < .0001) as well as 1-year mortality (adjusted HR 2.86; 95% CI 1.28-6.39; P = .012). CONCLUSIONS: In patients with LVEF ≤ 35%, sustained VA during the early post-infarction phase is predictive of recurrent sustained VAs and 1-year mortality.

7.
Arch Cardiovasc Dis ; 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39232887

RESUMEN

BACKGROUND: Although guidelines recommend screening patients for atrial fibrillation (AF) after stroke, the optimal timing and combination of screening tools remain unclear. AIMS: We evaluated the suitability of a sequential combination of screening techniques for AF detected after stroke (AFDAS). We also compared patient characteristics according to the timing of AFDAS. METHODS: Patients without previous AF admitted for acute ischaemic stroke were prospectively enrolled. After a stepwise screening approach for AFDAS based on electrocardiogram, telemetry monitoring and in-hospital long-term Holter, patients with cryptogenic stroke underwent implantation of an implantable cardiac monitor (ICM). Early AFDAS was defined as AF diagnosed during hospitalization and late AFDAS as AF diagnosed on an ICM. RESULTS: Of the 240 patients included, 104 (43.3%) had a documented cause of stroke not related to AF. Among the 136 remaining patients, AFDAS was detected in 82 (60.3%) during the acute screening phase or during the 3-year follow-up by ICM. Early AFDAS was diagnosed by ECG, telemetry and in-hospital long-term Holter monitoring in 17 (20.7%), 25 (30.5%) and 18 (22.0%) patients, respectively. Among 76 patients who had an ICM implanted for cryptogenic stroke, AF was detected in 22 patients (28.9%). Except for age and stroke location, patients with early AFDAS did not differ from those with late AFDAS, particularly with regard to the prevalence of atrial cardiomyopathy markers. CONCLUSION: A stepwise approach to AFDAS screening allows early detection of AF in a considerable number of patients during their hospitalization. ICMs remain complementary to non-invasive screening tools for the detection of remote episodes of AF.

8.
JAMA Cardiol ; 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39110449

RESUMEN

This case report discusses progressive cardiogenic shock in a man aged 78 years after catheter ablation for ventricular tachycardia.

9.
Artículo en Inglés | MEDLINE | ID: mdl-39093275

RESUMEN

BACKGROUND: Electrical storm (ES) is a life-threatening condition, associated with substantial early and subacute mortality. Catheter ablation (CA) is a well-established therapy for ES. However, data regarding the impact of CA on the short-term and midterm survival of patients admitted for ES remain unclear. OBJECTIVES: This multicenter study aimed to investigate the impact of CA of ES on survival outcomes, while accounting for key patient characteristics associated with treatment selection. METHODS: A propensity score-matching (PSM) analysis was performed on 780 consecutive patients admitted for ES in 4 tertiary centers. PSM (1:1) based on the main characteristics associated with the use of CA or medical therapy alone was performed, resulting in 2 groups of 288 patients. RESULTS: After PSM, patients who underwent CA (n = 288) and those treated with medical therapy alone (n = 288) did not present any significant differences in the main demographic characteristics, ES presentation, and management. Compared with medical therapy alone, CA was associated with a significantly lower rate of ES recurrence at 1 year (5% vs 26%; P < 0.001). Similarly, CA was associated with a higher 1-year (91% vs 81%; P < 0.001) and 3-year (78% vs 71%; P = 0.017) survival after discharge. In subgroup analyses, effect of ablation therapy remained consistent in patients older than 70 years of age (HR: 0.39; 95% CI: 0.24-0.66), with substantial efficacy in patients with a LVEF <35% (HR: 0.39; 95% CI: 0.27-0.59). CONCLUSIONS: In propensity-matched analyses, this large study shows that CA-based management of patients admitted for ES is associated with a reduction in mortality compared with medical treatment, particularly in patients with a low ejection fraction.

10.
JACC Clin Electrophysiol ; 10(9): 1982-1994, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38970599

RESUMEN

BACKGROUND: Idiopathic ventricular fibrillation (IVF) can be associated with undetected distinct conditions such as microstructural cardiomyopathic alterations (MiCM) or Purkinje (Purk) activities with structurally normal hearts. OBJECTIVES: This study sought to evaluate the characteristics of recurrent VF recorded on implantable defibrillator electrograms, associated with these substrates. METHODS: This was a multicenter collaboration study. At 32 centers, we selected patients with an initial diagnosis of IVF and recurrent arrhythmia at follow-up without antiarrhythmic drugs, in whom mapping demonstrated Purk or MiCM substrate. We analyzed variables related to previous ectopy, sinus rate preceding VF, trigger, and initial VF cycle lengths. Logistic regression with cross validation was used to evaluate the performance of criteria to discriminate Purk or MiCM substrates. RESULTS: Among 95 patients (35 women, age 35 ± 11 years) meeting the inclusion criteria, IVF was associated with MiCM in 41 and Purk in 54 patients. A total of 117 arrhythmia recurrences including 91% VF were recorded on defibrillator. Three variables were mostly discriminant. Sinus tachycardia (≤570 ms) was more frequent in MiCM (35.9% vs 13.4%, P = 0.014) whereas short-coupled (<350 ms) triggers were most frequent in Purk-related VF (95.5% vs 23.1%, P = 0.001), which also had shorter VFCLs (182 ± 15 ms vs 215 ± 24 ms, P < 0.001).The multivariable combination provided the highest prediction (accuracy = 0.93 ± 0.05, range 0.833-1.000), discriminating 81% of IVF substrates with a high probability (>80%). Ectopy were inconsistently present before VF. CONCLUSIONS: Characteristics of arrhythmia recurrences on implantable cardioverter- defibrillator provide phenotypic markers of the distinct and hidden substrates underlying IVF. These findings have significant clinical and genetic implications.


Asunto(s)
Desfibriladores Implantables , Fibrilación Ventricular , Humanos , Femenino , Fibrilación Ventricular/terapia , Fibrilación Ventricular/fisiopatología , Masculino , Adulto , Persona de Mediana Edad , Recurrencia , Cardiomiopatías/fisiopatología , Cardiomiopatías/terapia , Cardiomiopatías/complicaciones , Ramos Subendocárdicos/fisiopatología , Electrocardiografía
11.
Artículo en Inglés | MEDLINE | ID: mdl-39079606

RESUMEN

Quinidine, the first antiarrhythmic drug, was widely used during the 20th century. Multiple studies have been conducted to provide insights into the pharmacokinetics and pleiotropic effects of Class Ia antiarrhythmic drugs. However, safety concerns and the emergence of new drugs led to a decline in their use during the 1990s. Despite this, recent studies have reignited the interest in quinidine, particularly for ventricular arrhythmias, where other antiarrhythmics have failed. In conditions such as Brugada syndrome, idiopathic ventricular fibrillation, early repolarization syndrome, short QT syndrome, and electrical storms, quinidine remains a valuable asset. Starting from the European and American recommendations, this comprehensive review aimed to explore the various indications for quinidine and the studies that support its use. We also discuss the potential future of quinidine, including the necessary research to optimize its use and patient selection. Additionally, it addresses the imperative task of mitigating the iatrogenic burden associated with quinidine usage and confronts the challenge of ensuring drug accessibility.

14.
Heart Rhythm O2 ; 5(4): 234-242, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38690147

RESUMEN

Background: Cardiac radioablation is a new treatment for patients with refractory ventricular tachycardia (VT). The target for cardiac radioablation is subject to cardiorespiratory motion (CRM), the heart's movement with breathing and cardiac contraction. Data regarding the magnitude of target CRM are limited but are highly important for treatment planning. Objectives: The study sought to assess CRM amplitude by using ablation catheter geometrical data. Methods: Electroanatomic mapping data of patients undergoing catheter ablation for VT at 3 academic centers were exported. The spatial position of the ablation catheter as a function of time while in contact with endocardium was analyzed and used to quantify CRM. Results: Forty-four patients with ischemic and nonischemic cardiomyopathy and VT contributed 1364 ablation lesions to the analysis. Average cardiac and respiratory excursion were 1.62 ± 1.21 mm and 12.12 ± 4.10 mm, respectively. The average ratio of respiratory to cardiac motion was approximately 11:1. CRM was greatest along the craniocaudal axis (9.66 ± 4.00 mm). Regional variations with respect to respiratory and cardiac motion were observed: basal segments had smaller displacements vs midventricular and apical segments. Patient characteristics (previous cardiac surgery, height, weight, body mass index, and left ventricular ejection fraction) had a statistically significant, albeit clinically moderate, impact on CRM. Conclusion: CRM is primarily determined by respiratory displacement and is modulated by the location of the target and the patient's biometric characteristics. The patient-specific quantification of CRM may allow to decrease treatment volume and reduce radiation exposure of surrounding organs at risk while delivering the therapeutic dose to the target.

15.
Hellenic J Cardiol ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38663567

RESUMEN

BACKGROUND: Long-term data showed that up to 27% of pulmonary veins are reconnected using cryoballoon ablation. This study aimed to evaluate the efficacy of the latest 4th-generation cryoballoon catheters using ultra high-resolution mapping. METHODS: In patients with atrial fibrillation, a standard pulmonary vein isolation (PVI) with the latest 4th-generation cryoballoon catheter (Arctic Front Advance PRO, Medtronic Minneapolis, USA) and the spiral mapping catheter (Achieve Advance, Medtronic, Minneapolis, MN, USA) was performed. Subsequently, high-resolution mapping was achieved using the novel multipolar grid mapping catheter (Advisor HD Grid SE, Abbott Laboratories, USA). Follow-up was obtained after 6 months by means of a 7-day Holter electrocardiogram. RESULTS: In our study, acute PVI was successfully achieved in all 31 patients. The latest 4th-generation cryoballoon catheter is safe in the acute phase of PVI. Additional high-resolution mapping (mean points per map 21,001 ± 4911) using the multipolar grid mapping catheter enabled us to identify residual gaps only in the carina pulmonary vein region; therefore, no additional ablation was performed. Three of 31 patients (10%) presented with atrial arrhythmia recurrence always related with pulmonary vein reconnection; using high-resolution mapping had no additional benefit in identifying pulmonary veins in which reconnection will occur. CONCLUSION: The utility of additional high-density mapping, facilitated by the HD Grid catheter after PVI with the 4th-generation cryoballoon catheter do not substantiate a discernible advantage over conventional mapping methodologies, particularly, the spiral mapping catheter. Residual carinal conduction was observed in a substantial cohort of patients (48%), highlighting a persistent challenge in achieving complete electrical isolation.

17.
Artículo en Inglés | MEDLINE | ID: mdl-38555030
19.
Trends Cardiovasc Med ; 34(7): 488-496, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38191005

RESUMEN

Patients treated with cardiac stereotactic body radiation therapy (radioablation) for refractory ventricular arrhythmias are patients with advanced structural heart disease and significant comorbidities. However, data regarding 1-year mortality after the procedure are scarce. This systematic review and pooled analysis aimed at determining 1-year mortality after cardiac radioablation for refractory ventricular arrhythmias and investigating leading causes of death in this population. MEDLINE/EMBASE databases were searched up to January 2023 for studies including patients undergoing cardiac radioablation for the treatment of refractory ventricular arrhythmias. Quality of included trials was assessed using the NIH Tool for Case Series Studies (PROSPERO CRD42022379713). A total of 1,151 references were retrieved and evaluated for relevance. Data were extracted from 16 studies, with a total of 157 patients undergoing cardiac radioablation for refractory ventricular arrhythmias. Pooled 1-year mortality was 32 % (95 %CI: 23-41), with almost half of the deaths occurring within three months after treatment. Among the 157 patients, 46 died within the year following cardiac radioablation. Worsening heart failure appeared to be the leading cause of death (52 %), although non-cardiac mortality remained substantial (41 %) in this population. Age≥70yo was associated with a significantly higher 12-month all-cause mortality (p<0.022). Neither target volume size nor radiotherapy device appeared to be associated with 1-year mortality (p = 0.465 and p = 0.199, respectively). About one-third of patients undergoing cardiac stereotactic body radiation therapy for refractory ventricular arrhythmias die within the first year after the procedure. Worsening heart failure appears to be the leading cause of death in this population.


Asunto(s)
Causas de Muerte , Radiocirugia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Progresión de la Enfermedad , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Radiocirugia/efectos adversos , Radiocirugia/mortalidad , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA