Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Otol Neurotol ; 45(5): 529-535, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693093

RESUMEN

OBJECTIVE: We assessed three cochlear implant (CI) suppliers: Advanced Bionics, Cochlear Limited, and MED-EL, for implant revision requiring reoperation after CI placement. STUDY DESIGN: Retrospective cohort study of integrated-health-system database between 2010 and 2021. Separate models were created for pediatric (age <18) and adult (age ≥18) cohorts. PATIENTS: Pediatric (age <18) and adult (age ≥18) patients undergoing cochlear implantation within our integrated healthcare system. MAIN OUTCOME MEASURE: Revision after CI placement. Cox proportional hazard regression was used to evaluate revision risk and adjust for confounding factors. Hazard ratios (HRs) and 95% confidence intervals (CIs) are presented. RESULTS: A total of 2,347 patients underwent a primary CI placement, and Cochlear Limited was most implanted (51.5%), followed by Advanced Bionics (35.2%) and MED-EL (13.3%). In the pediatric cohort, the 7-year crude revision rate was 10.9% for Advanced Bionics and 4.8% for Cochlear Limited, whereas MED-EL had insufficient cases. In adults, the rates were 9.1%, 4.5%, and 3.3% for Advanced Bionics, MED-EL, and Cochlear Limited, respectively. After 2 years of postoperative follow-up, Advanced Bionics had a significantly higher revision risk (HR = 8.25, 95% CI = 2.91-23.46); MED-EL had no difference (HR = 2.07, 95% CI = 0.46-9.25). CONCLUSION: We found an increased revision risk after 2 years of follow-up for adults with Advanced Bionics CI devices. Although we found no statistical difference between manufacturers in the pediatric cohort, after 2 years of follow-up, there were increasing trends in the revision probability for Advanced Bionics. Further research may determine whether patients are better suited for some CI devices.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Prestación Integrada de Atención de Salud , Reoperación , Humanos , Implantes Cocleares/estadística & datos numéricos , Reoperación/estadística & datos numéricos , Masculino , Estudios Retrospectivos , Femenino , Niño , Adulto , Implantación Coclear/estadística & datos numéricos , Implantación Coclear/tendencias , Adolescente , Prestación Integrada de Atención de Salud/estadística & datos numéricos , Persona de Mediana Edad , Preescolar , Adulto Joven , Anciano , Lactante , Estudios de Cohortes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA