Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Clin Imaging ; 101: 137-141, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37336169

RESUMEN

PURPOSE: To evaluate the complexity of diagnostic radiology reports across major imaging modalities and the ability of ChatGPT (Early March 2023 Version, OpenAI, California, USA) to simplify these reports to the 8th grade reading level of the average U.S. adult. METHODS: We randomly sampled 100 radiographs (XR), 100 ultrasound (US), 100 CT, and 100 MRI radiology reports from our institution's database dated between 2022 and 2023 (N = 400). These were processed by ChatGPT using the prompt "Explain this radiology report to a patient in layman's terms in second person: ". Mean report length, Flesch reading ease score (FRES), and Flesch-Kincaid reading level (FKRL) were calculated for each report and ChatGPT output. T-tests were used to determine significance. RESULTS: Mean report length was 164 ± 117 words, FRES was 38.0 ± 11.8, and FKRL was 10.4 ± 1.9. FKRL was significantly higher for CT and MRI than for US and XR. Only 60/400 (15%) had a FKRL <8.5. The mean simplified ChatGPT output length was 103 ± 36 words, FRES was 83.5 ± 5.6, and FKRL was 5.8 ± 1.1. This reflects a mean decrease of 61 words (p < 0.01), increase in FRES of 45.5 (p < 0.01), and decrease in FKRL of 4.6 (p < 0.01). All simplified outputs had FKRL <8.5. DISCUSSION: Our study demonstrates the effective use of ChatGPT when tasked with simplifying radiology reports to below the 8th grade reading level. We report significant improvements in FRES, FKRL, and word count, the last of which requires modality-specific context.


Asunto(s)
Comprensión , Radiología , Adulto , Humanos , Radiografía , Imagen por Resonancia Magnética , Bases de Datos Factuales
2.
Cardiovasc Intervent Radiol ; 46(7): 870-879, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37217649

RESUMEN

BACKGROUND: Examine the association of metformin use and overall survival (OS) in patients with HCC undergoing image-guided liver-directed therapy (LDT): ablation, transarterial chemoembolization (TACE), or Yttrium-90 radioembolization (Y90 RE). METHODS: Using National Cancer Institute Surveillance, Epidemiology, and End Results registry and Medicare claims databases between 2007 and 2016, we identified patients ≥ 66 years who underwent LDT within 30 days of HCC diagnosis. Patients with liver transplant, surgical resection, and other malignancies were excluded. Metformin use was identified by at least two prescription claims within 6 months before LDT. OS was measured by time between first LDT and death or last Medicare observation. Comparisons were performed between both all and diabetic patients on and not on metformin. RESULTS: Of 2746 Medicare beneficiaries with HCC undergoing LDT, 1315 (47.9%) had diabetes or diabetes-related complications. Among all and diabetic patients, 433(15.8%) and 402 (30.6%) were on metformin respectively. Median OS was greater for patients on metformin (19.6 months, 95% CI 17.1-23.0) vs those not (16.0 months, 15.0-16.9; p = 0.0238). Patients on metformin had lower risk of death undergoing ablation (HR 0.70; 0.51-0.95; p = 0.0239) and TACE (HR 0.76, 0.66-0.87; p = 0.0001), but not Y90 RE (HR1.22, 0.89-1.69; p = 0.2231). Among diabetics, OS was greater for those on metformin vs those not (HR 0.77, 0.68-0.88; p < 0.0001). Diabetic patients on metformin had longer OS undergoing TACE (HR 0.71, 0.61-0.83; p < 0.0001), but not ablation (HR 0.74, 0.52-1.04; p = 0.0886) or Y90 RE (HR 1.26, 0.87-1.85; p = 0.2217). CONCLUSION: Metformin use is associated with improved survival in HCC patients undergoing TACE and ablation.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Anciano , Humanos , Estados Unidos/epidemiología , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Quimioembolización Terapéutica/métodos , Resultado del Tratamiento , Medicare , Sistema de Registros , Estudios Retrospectivos
3.
Med Phys ; 50(6): 3459-3474, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36906877

RESUMEN

BACKGROUND: Approximately 500 000 patients present with critical limb ischemia (CLI) each year in the U.S., requiring revascularization to avoid amputation. While peripheral arteries can be revascularized via minimally invasive procedures, 25% of cases with chronic total occlusions are unsuccessful due to inability to route the guidewire beyond the proximal occlusion. Improvements to guidewire navigation would lead to limb salvage in a greater number of patients. PURPOSE: Integrating ultrasound imaging into the guidewire could enable direct visualization of routes for guidewire advancement. In order to navigate a robotically-steerable guidewire with integrated imaging beyond a chronic occlusion proximal to the symptomatic lesion for revascularization, acquired ultrasound images must be segmented to visualize the path for guidewire advancement. METHODS: The first approach for automated segmentation of viable paths through occlusions in peripheral arteries is demonstrated in simulations and experimentally-acquired data with a forward-viewing, robotically-steered guidewire imaging system. B-mode ultrasound images formed via synthetic aperture focusing (SAF) were segmented using a supervised approach (U-net architecture). A total of 2500 simulated images were used to train the classifier to distinguish the vessel wall and occlusion from viable paths for guidewire advancement. First, the size of the synthetic aperture resulting in the highest classification performance was determined in simulations (90 test images) and compared with traditional classifiers (global thresholding, local adaptive thresholding, and hierarchical classification). Next, classification performance as a function of the diameter of the remaining lumen (0.5 to 1.5 mm) in the partially-occluded artery was tested using both simulated (60 test images at each of 7 diameters) and experimental data sets. Experimental test data sets were acquired in four 3D-printed phantoms from human anatomy and six ex vivo porcine arteries. Accuracy of classifying the path through the artery was evaluated using microcomputed tomography of phantoms and ex vivo arteries as a ground truth for comparison. RESULTS: An aperture size of 3.8 mm resulted in the best-performing classification based on sensitivity and Jaccard index, with a significant increase in Jaccard index (p < 0.05) as aperture diameter increased. In comparing the performance of the supervised classifier and traditional classification strategies with simulated test data, sensitivity and F1 score for U-net were 0.95 ± 0.02 and 0.96 ± 0.01, respectively, compared to 0.83 ± 0.03 and 0.41 ± 0.13 for the best-performing conventional approach, hierarchical classification. In simulated test images, sensitivity (p < 0.05) and Jaccard index both increased with increasing artery diameter (p < 0.05). Classification of images acquired in artery phantoms with remaining lumen diameters ≥ 0.75 mm resulted in accuracies > 90%, while mean accuracy decreased to 82% when artery diameter decreased to 0.5 mm. For testing in ex vivo arteries, average binary accuracy, F1 score, Jaccard index, and sensitivity each exceeded 0.9. CONCLUSIONS: Segmentation of ultrasound images of partially-occluded peripheral arteries acquired with a forward-viewing, robotically-steered guidewire system was demonstrated for the first-time using representation learning. This could represent a fast, accurate approach for guiding peripheral revascularization.


Asunto(s)
Arterias , Humanos , Animales , Porcinos , Microtomografía por Rayos X , Ultrasonografía
4.
Cardiovasc Intervent Radiol ; 46(1): 60-68, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36450996

RESUMEN

PURPOSE: To evaluate the relationship between non-tumor liver (NTL) dose and adverse events (AE) in patients with hepatocellular carcinoma (HCC) treated with glass-based Yttrium-90 radioembolization (Y90-RE). MATERIALS AND METHODS: A retrospective analysis of patients with HCC treated with Y90-RE between 2013 and 2018 was performed. Baseline characteristics including demographics and Y90-RE treatment approach were captured. Common Terminology Criteria for Adverse Events v5 was assessed at months 3 and 6 post-treatment. Using voxel-based dosimetry with MIM Software V. 6.9, dose-volume histograms of treated area of liver were created. Receiver operator characteristic curve was used to determine NTL dose threshold predicting AEs. Multivariate analysis was used to determine independent clinical factors of predicting severe AEs. Chi-square analysis was used to compare proportions. RESULTS: Two hundred and twenty-nine consecutive patients (115(50.2%) lobar and 114(49.8%) segmental) were included. At 3 months, there was a lower rate of any grade AE (55(46%) segmental and 36(31%) lobar, p = 0.009) and increased rate of severe AEs for lobar compared to segmental (2(2%) segmental and 9(8%) lobar, p = 0.029). At 6 months, severe AEs were greater for lobar than segmental (1(1%) segmental vs 10(9%) lobar, p = 0.005). For lobar Y90-RE, mean NTL dose of 112 Gy predicted severe AE (89% sensitivity and 91% specificity (AUC = 0.95, p = < 0.0001) at 3 and 6 months. For the segmental group, no significant association was found between NTL dose and severe treatment-related AE at 3 and 6 months. CONCLUSION: In patients with HCC undergoing glass-based lobar Y90-RE, NTL dose of > 112 Gy is associated with severe treatment-related AEs at 3-6 months.


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Estudios Retrospectivos , Radioisótopos de Itrio/efectos adversos , Embolización Terapéutica/efectos adversos , Resultado del Tratamiento , Microesferas
6.
Radiographics ; 42(2): 594-608, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35148246

RESUMEN

Osteoarthritis (OA) of the shoulder and hip is a leading cause of physical disability and mental distress. Traditional nonsurgical management alone is often unable to completely address the associated chronic joint pain. Moreover, a large number of patients are not eligible for joint replacement surgery owing to comorbidities or cost. Radiofrequency ablation (RFA) of articular sensory nerve fibers can disrupt the transmission of nociceptive signals by neurolysis, thereby providing long-term pain relief. A subtype of RFA, cooled RFA (CRFA), utilizes internally cooled electrodes to generate larger ablative zones compared with standard RFA techniques. Given the complex variable innervation of large joints such as the glenohumeral and hip joints, a larger ablative treatment zone, such as that provided by CRFA, is desired to capture a greater number of afferent nociceptive fibers. The suprascapular, axillary, and lateral pectoral nerve articular sensory branches are targeted during CRFA of the glenohumeral joint. The obturator and femoral nerve articular sensory branches are targeted during CRFA of the hip. CRFA is a promising tool in the interventionalist's arsenal for management of OA-related pain and symptoms, particularly in patients who cannot undergo, have long wait times until, or have persistent pain following joint replacement surgery. An invited commentary by Tomasian is available online. ©RSNA, 2022.


Asunto(s)
Dolor Crónico , Osteoartritis , Ablación por Radiofrecuencia , Artralgia , Dolor Crónico/etiología , Dolor Crónico/cirugía , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Ablación por Radiofrecuencia/métodos , Hombro , Resultado del Tratamiento
7.
Artículo en Inglés | MEDLINE | ID: mdl-35143395

RESUMEN

Peripheral artery disease (PAD) affects more than 200 million people globally. Minimally invasive endovascular procedures can provide relief and salvage limbs while reducing injury rates and recovery times. Unfortunately, when a calcified chronic total occlusion is encountered, ~25% of endovascular procedures fail due to the inability to advance a guidewire using the view provided by fluoroscopy. To enable a sub-millimeter, robotically steerable guidewire to cross these occlusions, a novel single-element, dual-band transducer is developed that provides simultaneous multifrequency, forward-viewing imaging with high penetration depth and high spatial resolution while requiring only a single electrical connection. The design, fabrication, and acoustic characterization of this device are described, and proof-of-concept imaging is demonstrated in an ex vivo porcine artery after integration with a robotically steered guidewire. Measured center frequencies of the developed transducer were 16 and 32 MHz, with -6 dB fractional bandwidths of 73% and 23%, respectively. When imaging a 0.2-mm wire target at a depth of 5 mm, measured -6 dB target widths were 0.498 ± 0.02 and 0.268 ± 0.01 mm for images formed at 16 and 32 MHz, respectively. Measured SNR values were 33.3 and 21.3 dB, respectively. The 3-D images of the ex vivo artery demonstrate high penetration for visualizing vessel morphology at 16 MHz and ability to resolve small features close to the transducer at 32 MHz. Using images acquired simultaneously at both frequencies as part of an integrated forward-viewing, guidewire-based imaging system, an interventionalist could visualize the best path for advancing the guidewire to improve outcomes for patients with PAD.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Acústica , Animales , Arterias , Diseño de Equipo , Humanos , Fantasmas de Imagen , Porcinos , Transductores
8.
Semin Intervent Radiol ; 38(4): 405-411, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34629706

RESUMEN

Thoughtful and accurate dosimetry is critical to obtain the safest and most efficacious yttrium-90 (Y90) radioembolization of primary and secondary liver cancers. Three dosimetry models are currently used in clinical practice, namely, body surface area model, medical internal radiation dose model, and the partition model. The objective of this review is to briefly outline the history behind Y90 dosimetry and the difference between the aforementioned models. When applying these three models to a single case, the differences between them are further demonstrated. Each dosimetry model in clinical practice has its own benefits and limitations. Therefore, it is incumbent upon practicing interventional radiologists to be aware of these differences to optimize treatment outcomes for their patients.

9.
World J Gastrointest Oncol ; 13(5): 440-452, 2021 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-34040704

RESUMEN

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has made it more challenging for patients to undergo yttrium-90 (Y-90) radioembolization (RE). Same day Y-90 RE provides an opportunity to minimize logistical challenges and infection risk associated with COVID-19, thus improving patient access. AIM: To describe the use of same day Y-90 RE with routine single photon emission computed tomography/computed tomography (SPECT/CT) in order to optimize therapy. METHODS: All patients were selected for Y-90 RE through a multidisciplinary tumor board, and were screened and tested for COVID-19 infection per institutional protocol. A same day procedure was developed, consisting of angiography, imaging, and Y-90 resin particle delivery. Routine SPECT/CT after technetium-99m macroaggregated albumin (Tc-99m MAA) administration was performed for assessment of arterial supply, personalized dosimetry, and extrahepatic activity. Post-treatment Y-90 bremsstrahlung SPECT/CT was performed for confirmation of particle delivery, by utilization of energy windowing to limit signal from previously administered Tc-99m MAA particles. RESULTS: A total of 14 patients underwent same day Y-90 RE between March and June 2020. Mean lung shunt fraction was 6.13% (range 3.5%-13.1%). Y-90 RE was performed for a single lesion in 7 patients, while the remaining 7 patients had treatment of multifocal lesions. The largest lesion measured 8.3 cm. All patients tolerated the procedure well and were discharged the same day. CONCLUSION: Same day Y-90 RE with resin-based microspheres is feasible, and provides an opportunity to mitigate infection risk and logistical challenges associated with the COVID-19 pandemic and beyond. We recommend consideration of SPECT/CT, especially among patients with complex malignancies, for the potential to improve outcomes and eligibility of patients to undergo same day Y-90 RE.

10.
Curr Probl Diagn Radiol ; 50(5): 623-628, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32561153

RESUMEN

PURPOSE: To compare vascular plugs to coil embolization of the proximal splenic artery and evaluate differences in radiation exposure to the patients. METHODS: An electronic literature search was performed for relevant studies from January 2000 to July 2018 that compared the efficacy of vascular plugs vs coils in splenic artery embolization. Only studies that investigated coil or vascular plug use, without combination with other embolic agents, were included. Meta-analysis was performed using a fixed effects model approach with the inverse variance-weighted average method to determine pooled differences in time to vessel occlusion, procedure time, fluoroscopy time, total number of devices used, and radiation exposure. Heterogeneity was assessed using the I square statistic. Pooled outcomes were compared, and quality assessments were evaluated using the Newcastle Ottawa Scale. RESULTS: Eight studies met inclusion criteria. 81 patients were embolized with vascular plugs and 52 patients with coils only. The most common indication for splenic artery embolization was trauma. Time to vessel occlusion was shorter in the vascular plug group by 7.11 minutes (P = 0.003). Fluoroscopy time was shorter by 13.82 minutes in the vascular plug cohort, and these patients received less radiation (-439 mGy) compared to the coil group (P = 0.006 and P = 0.02, respectively). The number of devices was significantly fewer in the vascular plug group (-3.54; P < 0.001). Procedure time was not statistically significant. CONCLUSION: Our data supports the vascular plug is superior to coils for embolization of the proximal splenic artery with respect to occlusion time, fluoroscopy time, patient radiation exposure, and number occlusive devices used.


Asunto(s)
Embolización Terapéutica , Exposición a la Radiación , Humanos , Estudios Retrospectivos , Bazo , Arteria Esplénica/diagnóstico por imagen , Resultado del Tratamiento
11.
Acad Radiol ; 28(8): 1081-1085, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32527708

RESUMEN

RATIONALE AND OBJECTIVES: Historically, patients undergoing image-guided percutaneous gastrostomy tube placement have been admitted overnight with feeds commencing 12-24 hours postprocedure. With new expedited feeding protocols starting 3-4 hours postprocedure, same-day discharge is now possible. The purpose of this study was to evaluate the safety and cost of image-guided percutaneous gastrostomy tube placement as an outpatient procedure. MATERIALS AND METHODS: In this retrospective study, 131 patients (age 63.9 ± 11.6; 34% female) underwent gastrostomy tube placement as an outpatient procedure with expedited feeding protocol versus 40 patients (age 61.3 ± 12.6; 38% female) who were hospitalized overnight with feeds starting at 12-24 hours, primarily based on operator preference. The two groups were compared regarding complications within 90 days of procedure. Using a subgroup of 33 consecutive patients, procedural costs (total combined insurer and patient payments for professional and hospital services) for outpatients vs. hospitalized patients were compared. RESULTS: Complication rates were similar (p = 0.64) for gastrostomy tubes placed on outpatients (0.17 complications/procedure: 4 bleeding, 2 aspiration pneumonia, 1 abdominal abscess, 4 significant pain, 6 cellulitis, 1 surgical consult, 4 malpositioned/fractured tubes) and hospitalized patients (0.20 complications/procedure: 1 aspiration pneumonia, 1 significant pain, 3 cellulitis, 1 surgical consult, 2 fractured tubes). Total combined insurer and patient payments were similar ($2193/outpatient vs $2701/hospitalized patient; p= 0.52). CONCLUSION: Outpatient image-guided percutaneous gastrostomy tube placement with an expedited feeding protocol is a safe and cost-comparable alternative to historic overnight hospitalization. Further prospective investigation with a larger sample is warranted.


Asunto(s)
Gastrostomía , Pacientes Ambulatorios , Anciano , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
IEEE Trans Biomed Eng ; 68(7): 2222-2232, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33264091

RESUMEN

OBJECTIVE: The current standard of care for peripheral chronic total occlusions involves the manual routing of a guidewire under fluoroscopy. Despite significant improvements in recent decades, navigation remains clinically challenging with high rates of procedural failure and iatrogenic injury. To address this challenge, we present a proof-of-concept robotic guidewire system with forward-viewing ultrasound imaging to allow visualization and maneuverability through complex vasculature. METHODS: A 0.035" guidewire-specific ultrasound transducer with matching layer and acoustic backing was designed, fabricated, and characterized. The effect of guidewire motion on signal decorrelation was assessed with simulations and experimentally, driving the development of a synthetic aperture beamforming approach to form images as the transducer is steered on the robotic guidewire. System performance was evaluated by imaging wire targets in water. Finally, proof-of-concept was demonstrated by imaging an ex vivo artery. RESULTS: The designed custom transducer was fabricated with a center frequency of 15.7 MHz, 45.4% fractional bandwidth, and 31 dB SNR. In imaging 20 µm wire targets at a depth of 6 mm, the lateral -6 dB target width was 0.25 ± 0.03 mm. The 3D artery reconstruction allowed visualization of vessel wall structure and lumen. CONCLUSION: Initial proof-of-concept for an ultrasound transducer-tipped steerable guidewire including 3D image formation without an additional sensor to determine guidewire position was demonstrated for a sub-mm system with an integrated ultrasound transducer and a robotically-steered guidewire. SIGNIFICANCE: The developed forward-viewing, robotically-steered guidewire may enable navigation through occluded vascular regions that cannot be crossed with current methods.


Asunto(s)
Tecnología , Transductores , Diseño de Equipo , Fantasmas de Imagen , Ultrasonografía
14.
Spine (Phila Pa 1976) ; 45(15): E927-E932, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32675605

RESUMEN

STUDY DESIGN: Retrospective review. OBJECTIVE: To ascertain impact of preprocedural magnetic resonance imaging (MRI) or nuclear medicine Tc99m-DMP scintigraphy on the treatment plan when compared with plain films and/or computed tomography prior to vertebral augmentation procedures. SUMMARY OF BACKGROUND DATA: Over 1 million vertebral compression fractures (VCFs) occur in the United States annually with over 150,000 individuals hospitalized each year. Physical examination and history are essential to the workup of VCFs, but imaging remains necessary for confirming the diagnosis. VCFs can be imaged with various modalities and there is limited data on the comparative effectiveness of different imaging modalities. METHODS: Six hundred fifty consecutive patients treated with vertebral augmentation at a single institution between May of 2013 and April of 2018 were reviewed. Preprocedure imaging of the spine obtained within 30 days prior to the procedure were reviewed. Preprocedure imaging results were cross-referenced against the levels treated by vertebral augmentation to determine whether there was a change in the levels treated after receiving an MRI or NM imaging study. RESULTS: Three hundred sixty-three patients had adequate imaging for inclusion. One hundred fifty-four of these 363 patients (42.4%) had an alteration of their treatment plan based upon the MR or NM imaging. Fewer vertebral levels were treated in 33, different levels were treated in 41, and more levels were treated in 80 patients. CONCLUSION: MRI or nuclear medicine bone scan imaging prior to vertebral augmentation altered the location and number of levels treated in a large percentage of patients, adding specificity to treatment over findings on radiographs or computed tomography alone. LEVEL OF EVIDENCE: 3.


Asunto(s)
Fracturas por Compresión/diagnóstico por imagen , Cifoplastia/métodos , Imagen por Resonancia Magnética/métodos , Fracturas de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Vertebroplastia/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fracturas por Compresión/metabolismo , Fracturas por Compresión/cirugía , Humanos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Cintigrafía/métodos , Estudios Retrospectivos , Fracturas de la Columna Vertebral/cirugía , Compuestos de Sulfhidrilo , Agregado de Albúmina Marcado con Tecnecio Tc 99m
15.
Am J Hosp Palliat Care ; 37(8): 619-623, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32602380

RESUMEN

OBJECTIVES: The purpose of this report is to describe the effect of computed tomography-guided bilateral pudendal nerve cryoablations on pain and time to discharge in the setting of acute hospitalizations secondary to refractory pelvic pain from cancer. METHODS: Investigators queried the medical record for patients who underwent pudendal nerve cryoablation using the Category III Current Procedural Technology code assignment 0442T or Category I code 64640 for cases prior to 2015. The resulting list was reviewed, and procedures performed on inpatients for intractable pelvic pain related to neoplasm were selected. The final cohort was then analyzed with regard to patient demographics, procedure details, technical success, safety, pain scores, and time to discharge. RESULTS: Ten patients underwent cryoablation by 3 operators for palliation of painful pelvic neoplasms between June 2014 and January 2019. All probes were satisfactorily positioned and freeze cycles undertaken without difficulty. There were no procedure-related complications or adverse events. The mean difference in pre- and posttreatment worst pain scores was significant (n = 5.20, P = .003). The mean time to discharge following the procedure was 2.3 days. CONCLUSION: Computed tomography-guided percutaneous cryoablation of the bilateral pudendal nerves may represent a viable option in the setting of acute hospitalization secondary to intractable pain in patients with pelvic neoplasms.


Asunto(s)
Dolor en Cáncer/cirugía , Criocirugía/métodos , Dolor Intratable/cirugía , Cuidados Paliativos/métodos , Neoplasias Pélvicas/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Alta del Paciente , Estudios Retrospectivos , Factores Socioeconómicos
16.
Cardiovasc Intervent Radiol ; 43(7): 1006-1014, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32367230

RESUMEN

PURPOSE: To investigate timing of Yttrium-90 radioembolization (Y90) during treatment course, genomics, and other clinical factors as predictors of overall survival (OS) in colorectal liver metastasis (CRLM) that have progressed on at least one line of chemotherapy. MATERIALS AND METHODS: This was a retrospective study from 2013 to 2018 of patients with CRLM and genomic analysis prior to Y90 at a multihospital tertiary referral center. OS from liver metastasis diagnosis and predictors of OS were analyzed using Kaplan-Meier estimation with log-rank and Cox regression analyses. RESULTS: Overall, 58 patients with CRLM who progressed on at least one line of chemotherapy who had genomic analysis prior to Y90 were identified. Median OS after hepatic metastasis was 29.9 months. Of these, 16 (28%) patients received Y90 after failure of the first-line systemic chemotherapy. There was significantly prolonged OS in patients receiving Y90 immediately following failure of the first-line chemotherapy folinic acid, fluorouracil, oxaliplatin ((FOLFOX) ± bevacizumab) versus following multiple lines of chemotherapy (median OS of 46.3 vs. 26.6 months, P = 0.005). The presence of genetic mutation in tumor, MAPK pathway wild type, left-sided primary tumor, low MELD score, and non-diffuse unilobar disease were also found to be predictors prolonged survival on log-rank analysis (P's < 0.05). On multivariate analysis, receiving Y90 after failure of the first line of chemotherapy, low baseline MELD score, and baseline ECOG performance score of 0 were all found to be independent predictors of prolonged OS from the time of metastatic disease diagnosis (P's < 0.05). CONCLUSION: In patients with CRLM, receiving Y90 after failing the first line of chemotherapy, lack of genetic mutation, low MELD score, and lower tumor burden appear to be independent predictors of prolonged OS. LEVEL OF EVIDENCE: Level 4, case-control study.


Asunto(s)
Braquiterapia/métodos , Neoplasias Colorrectales/patología , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundario , Mutación/genética , Radioisótopos de Itrio/uso terapéutico , Anciano , Estudios de Casos y Controles , Femenino , Genómica , Humanos , Estimación de Kaplan-Meier , Neoplasias Hepáticas/genética , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Retrospectivos , Análisis de Supervivencia , Factores de Tiempo , Carga Tumoral
17.
J Vasc Interv Radiol ; 31(6): 925-933, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32307310

RESUMEN

PURPOSE: To determine predictors of survival after transarterial radioembolization of hepatic metastases from breast cancer. MATERIALS AND METHODS: Twenty-four patients with chemotherapy-refractory hepatic metastases from breast cancer who underwent radioembolization from 2013 to 2018 were evaluated based on various demographic and clinical factors before and after treatment. Overall survival (OS) was estimated by Kaplan-Meier method. Log-rank analysis was performed to determine predictors of prolonged OS from the time of first radioembolization and first hepatic metastasis diagnosis. RESULTS: Median OS times were 35.4 and 48.6 months from first radioembolization and time of hepatic metastasis diagnosis, respectively. Radioembolization within 6 months of hepatic metastasis diagnosis was a positive predictor of survival from first radioembolization, with median OS of 38.9 months vs 22.1 months for others (P = .033). Estrogen receptor (ER)-positive status predicted prolonged survival (38.6 months for ER+ vs 5.4 months for ER-; P = .005). The presence of abdominal pain predicted poor median OS: 12.8 months vs 38.6 months for others (P < .001). The presence of ascites was also a negative predictor of OS (1.7 months vs 35.4 months for others; P = .037), as was treatment-related grade ≥ 2 toxicity at 3 months (5.4 months vs 38.6 months for others; P = .017). CONCLUSIONS: In patients with metastatic breast cancer, radioembolization within 6 months of hepatic metastasis diagnosis and ER+ status appear to be positive predictors of prolonged survival. Conversely, baseline abdominal pain, baseline ascites, and treatment-related grade ≥ 2 toxicity at 3 months after treatment appear to be negative predictors of OS.


Asunto(s)
Neoplasias de la Mama/terapia , Embolización Terapéutica , Neoplasias Hepáticas/radioterapia , Radiofármacos/administración & dosificación , Radioisótopos de Itrio/administración & dosificación , Adulto , Anciano , Neoplasias de la Mama/mortalidad , Neoplasias de la Mama/patología , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/secundario , Persona de Mediana Edad , Radiofármacos/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Radioisótopos de Itrio/efectos adversos
18.
Curr Probl Diagn Radiol ; 49(3): 154-156, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32273147

RESUMEN

RATIONALE AND OBJECTIVES: To assess the prevalence and structure of mentorship programs in interventional radiology (IR) residency programs. MATERIALS AND METHODS: A 12-question anonymous survey was distributed via email to all 78 program directors (PDs) of United States IR residency programs. The survey included information about the presence or absence of a formal mentorship program at their institution, how the program functions, potential barriers to implementation, and future plans for mentorship. RESULTS: Twenty-three of 78 integrated IR residency PDs completed the survey (response rate 29.5%). Thirteen of 23 reports that they currently have a formal mentorship program in place and 11 of 13 report no direct departmental support for mentorship. Of those that do not have a mentorship program in place, 5 of 10 report that implementation is underway. These programs report that the absence of a mentorship program is due to a lack of dedicated time and financial support. While 8 of 23 PDs were unaware of the Society of Interventional Radiology Mentor Match program, 6of 23 were registered as mentors through it. Nearly all PDs reported interest in receiving mentoring resources from SIR with the most popular choices being a dedicated mentorship educational course at the SIR annual meeting and regular mentorship articles and practical tips in publications such as IR quarterly. CONCLUSIONS: Despite involvement of many IR PDs in mentorship, numerous residency programs lack a formal mentorship program. Of those with a program, most don't receive direct departmental support and those without a program cite lack of time and financial support as barriers to effective implementation.


Asunto(s)
Internado y Residencia/métodos , Tutoría/métodos , Tutoría/estadística & datos numéricos , Radiología Intervencionista/educación , Actitud del Personal de Salud , Docentes Médicos , Humanos , Encuestas y Cuestionarios/estadística & datos numéricos , Estados Unidos
19.
Semin Intervent Radiol ; 37(1): 35-43, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32139969

RESUMEN

Trauma remains one of the leading causes of death in the United States in patients younger than 45 years. Blunt trauma is most commonly a result of high-speed motor vehicular collisions or high-level fall. The liver and spleen are the most commonly injured organs, with the liver being the most commonly injured organ in adults and the spleen being the most affected in pediatric blunt trauma. Liver injuries incur a high level of morbidity and mortality mostly secondary to hemorrhage. Over the past 20 years, angiographic intervention has become a mainstay of treatment of hepatic trauma. As there is an increasing need for the interventional radiologists to embolize active hemorrhage in the setting of blunt and penetrating hepatic trauma, this article aims to review the current level of evidence and contemporary management of hepatic trauma from the perspective of interventional radiologists. Embolization techniques and associated outcome and complications are also reviewed.

20.
JACC Case Rep ; 2(1): 64-68, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34316966

RESUMEN

This report describes the case of a previously healthy 30-year-old woman who presented with uncontrolled hypertension and renal failure. This case emphasizes the importance of considering renal artery disease. The differential diagnosis for renal artery stenosis is discussed, and the diagnosis and management of Takayasu's arteritis in this patient are highlighted. (Level of Difficulty: Beginner.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA