Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur Radiol ; 25(8): 2310-7, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25913571

RESUMEN

OBJECTIVES: To prospectively evaluate image quality (IQ) and radiation dose of dual-source cardiac computed tomography (CCTA) using different imaging protocols. METHODS: CCTA was performed in 150 patients using the retrospective ECG-gated spiral technique (rECG) the prospective ECG-gated technique (pECG), or the prospective ECG-gated technique with systolic imaging and automated tube voltage selection (pECGsys). IQ was rated using a 16-segment coronary artery model. Techniques were compared for overall IQ, IQ of the large and the small coronary artery segments. Effective dose was used for comparison of radiation dose. RESULTS: Overall IQ and IQ of the large segments showed no differences between the groups. IQ analysis of the small segments showed lowered IQ in pECGsys compared to rECG (p = 0.02), but not to pECG (p = 0.6). Effective dose did not differ significantly between rECG and pECG (p = 0.13), but was significantly lower for pECGsys (p < 0.001 vs. rECG and pECG). CONCLUSION: Radiation dose of dual-source CCTA in heart transplant recipients is significantly reduced by using prospective systolic scanning and automated tube voltage selection, while overall IQ and IQ of the large coronary segments are maintained. IQ appears to be lower compared to retrospective techniques with regard to small coronary segments. KEY POINTS: • Cardiac computed tomography angiography is useful for cardiac allograft vasculopathy assessment. • Despite elevated heart rate, dose reduction in cardiac computed tomography is possible. • Prospective systolic gating and automated tube voltage selection enable 50 % dose reduction.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Vasos Coronarios/diagnóstico por imagen , Trasplante de Corazón , Complicaciones Posoperatorias/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Electrocardiografía/métodos , Femenino , Estudios de Seguimiento , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sístole , Tomografía Computarizada Espiral/métodos , Adulto Joven
2.
Radiologe ; 53(2): 136-40, 2013 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-23371433

RESUMEN

CLINICAL/METHODICAL ISSUE: Evaluation of the normal and pathological fetal brain. STANDARD RADIOLOGICAL METHODS: Magnetic resonance imaging (MRI). METHODICAL INNOVATIONS: Advanced MRI of the fetal brain. PERFORMANCE: Diffusion tensor imaging (DTI) is used in clinical practice, all other methods are used at a research level. ACHIEVEMENTS: Serving as standard methods in the future. PRACTICAL RECOMMENDATIONS: Combined structural and functional data for all gestational ages will allow more specific insight into the developmental processes of the fetal brain. This gain of information will help provide a common understanding of complex spatial and temporal procedures of early morphological features and their impact on cognitive and sensory abilities.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/anatomía & histología , Encéfalo/embriología , Imagen de Difusión Tensora/métodos , Diagnóstico Prenatal/métodos , Humanos
3.
AJNR Am J Neuroradiol ; 34(2): 424-31, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22821916

RESUMEN

BACKGROUND AND PURPOSE: The quality of spectroscopic studies may be limited because of unrestricted fetal movement. Sedation is recommended to avoid motion artefacts. However, sedation involves side effects. The aim of this study was to assess the feasibility and quality of brain (1)H-MR spectroscopy in unsedated fetuses and to evaluate whether quality is dependent on the type of spectra, fetal presentation, GA, and/or fetal pathology. MATERIALS AND METHODS: Seventy-five single-voxel spectroscopic studies of the fetal brain, performed at gestational weeks 19-38 at 1.5T, were evaluated retrospectively. A PRESS (TE = 144 or 35 ms) was used. Fetal presentation, GA, and kind of pathology were recorded. The quality of the spectra was assessed by reviewing the spectral appearance (line width, signal-to-noise) of the creatine resonance obtained relative to concentrations (ratios-to-creatine) of choline, myo-inositol, and NAA. RESULTS: Of 75 studies, 50 (66.6%) were rated as readable: short TE = 17/50 (34%), long TE = 33/50 (66%), cephalic presentation in 36/50 (72%) studies, breech in 10/50 (20%) studies, and "other" presentation in 4/50 (8%) studies (mean GA, 31.0 weeks). Twenty-eight of 50 fetuses (56%) showed normal development (short TE = 12/28, long TE = 16/28), and 22/50 (44%) showed pathology. Of the 75 studies, 25 (33.3%) were not readable: short TE = 14/25 (56%), long TE = 11/25 (44%), cephalic presentation in 20/25 (80%) studies, breech in 4/25 (16%) studies, and other presentation in 1 study (4%) (mean GA, 30.1 week). Thirteen of 25 fetuses (52%) showed normal development; 12/25 (48%) showed pathology. Statistical analysis revealed no impact of the different parameters on the quality of spectra. CONCLUSIONS: Single-voxel spectroscopy can be performed in approximately two-thirds of unsedated fetuses, regardless of the type of spectra, fetal presentation, GA, and pathology.


Asunto(s)
Encéfalo/embriología , Encéfalo/metabolismo , Sedación Consciente , Enfermedades Fetales/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/normas , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Encéfalo/anomalías , Colina/metabolismo , Creatina/metabolismo , Femenino , Enfermedades Fetales/patología , Retardo del Crecimiento Fetal/metabolismo , Edad Gestacional , Humanos , Inositol/metabolismo , Presentación en Trabajo de Parto , Movimiento , Embarazo , Diagnóstico Prenatal/métodos , Diagnóstico Prenatal/normas , Protones , Estudios Retrospectivos , Relación Señal-Ruido
4.
Eur J Surg Oncol ; 38(8): 670-6, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22652037

RESUMEN

OBJECTIVE: To compare the diagnostic value of gadoxetic acid-enhanced MRI at 3.0 T with 64-row MDCT in the detection of colorectal liver metastases in diffuse fatty infiltration of the liver after neoadjuvant chemotherapy. METHODS: Twenty-three patients with colorectal liver metastases and at moderate to severe steatosis (25-90%) underwent prospectively preoperative tri-phasic MDCT (Somatom Sensation 64, Siemens) and gadoxetic acid-enhanced MRI (3-T Magnetom Trio, Siemens). All patients underwent surgical resection of liver metastases. Intraoperative ultrasound (IOUS) was carried out, which served as the standard of reference, together with histopathology. RESULTS: Overall, 68 metastases (range, 0.4-6 cm; 31/68 metastases [46%] ≤ 1 cm) were found at histology. MDCT detected 49/68 lesions (72%), and MRI 66/68 (97%, p < 0.001). For lesions ≤ 1 cm, MDCT detected only 13/31 (41.9%) and MRI 29/31 (93%, p < 0.001). Eight false-positive lesions were detected by MDCT, seven small lesions by MRI. There was no statistically significant difference between the two modalities in the detection of lesions > 1 cm (p = 0.250). IOUS detected all metastases and revealed two false-positive diagnoses. CONCLUSION: Gadoxetic acid-enhanced 3.0 T MRI is superior to 64-row MDCT in detecting colorectal liver metastases ≤ 1 cm during preoperative staging in patients with liver steatosis. A combination of MRI and IOUS may further improve the outcome of surgical treatment.


Asunto(s)
Neoplasias Colorrectales/secundario , Hígado Graso/complicaciones , Gadolinio DTPA , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Monitoreo Intraoperatorio/métodos , Tomografía Computarizada Multidetector/métodos , Anciano , Anciano de 80 o más Años , Biopsia/métodos , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/cirugía , Medios de Contraste , Diagnóstico Diferencial , Hígado Graso/diagnóstico , Femenino , Estudios de Seguimiento , Hepatectomía , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA