Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 21(12): 206-218, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33219743

RESUMEN

The commissioning and benchmark of a Monte Carlo (MC) model of the 6-MV Brainlab-Mitsubishi Vero4DRT linear accelerator for the purpose of quality assurance of clinical dynamic wave arc (DWA) treatment plans is reported. Open-source MC applications based on EGSnrc particle transport codes are used to simulate the medical linear accelerator head components. Complex radiotherapy irradiations can be simulated in a single MC run using a shared library format combined with BEAMnrc "source20." Electron energy tuning is achieved by comparing measured vs simulated percentage depth doses (PDDs) for MLC-defined field sizes in a water phantom. Electron spot size tuning is achieved by comparing measured and simulated inplane and crossplane beam profiles. DWA treatment plans generated from RayStation (RaySearch) treatment planning system (TPS) are simulated on voxelized (2.5 mm3 ) patient CT datasets. Planning target volume (PTV) and organs at risk (OAR) dose-volume histograms (DVHs) are compared to TPS-calculated doses for clinically deliverable dynamic volumetric modulated arc therapy (VMAT) trajectories. MC simulations with an electron beam energy of 5.9 MeV and spot size FWHM of 1.9 mm had the closest agreement with measurement. DWA beam deliveries simulated on patient CT datasets results in DVH agreement with TPS-calculated doses. PTV coverage agreed within 0.1% and OAR max doses (to 0.035 cc volume) agreed within 1 Gy. This MC model can be used as an independent dose calculation from the TPS and as a quality assurance tool for complex, dynamic radiotherapy treatment deliveries. Full patient CT treatment simulations are performed in a single Monte Carlo run in 23 min. Simulations are run in parallel using the Condor High-Throughput Computing software1 on a cluster of eight servers. Each server has two physical processors (Intel Xeon CPU E5-2650 0 @2.00 GHz), with 8 cores per CPU and two threads per core for 256 calculation nodes.


Asunto(s)
Radioterapia de Intensidad Modulada , Humanos , Método de Montecarlo , Aceleradores de Partículas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
2.
Med Phys ; 40(2): 021707, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23387730

RESUMEN

PURPOSE: To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for rendering the phase-space data compatible with BEAMnrc/DOSXYZnrc simulation software package is presented. METHODS: Monte Carlo (MC) simulations were performed to benchmark the TrueBeam 6 MV FFF phase space data that have been released by the Varian MC Research team. The simulations to benchmark the phase space data were done in three steps. First, the original phase space which was created on a cylindrical surface was converted into a format that was compatible with BEAMnrc. Second, BEAMnrc was used to create field size specific phase spaces located underneath the jaws. Third, doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 × 1 to 40 × 40 cm(2). Calculated percent depth doses (PDD), transverse profiles, and output factors were compared with measurements for all the fields simulated. After completing the benchmarking study, three stereotactic body radiotherapy (SBRT) VMAT plans created with the Eclipse treatment planning system (TPS) were calculated with Monte Carlo. Ion chamber and film measurements were also performed on these plans. 3D gamma analysis was used to compare Monte Carlo calculation with TPS calculations and with film measurement. RESULTS: For the benchmarking study, MC calculated and measured values agreed within 1% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 × 1 cm(2). Agreements in the 80%-20% penumbra widths were better than 2 mm for all the fields that were compared. With the exception of the 1 × 1 cm(2) field, the agreement between measured and calculated output factors was within 1%. It is of note that excellent agreement in output factors for all field sizes including highly asymmetric fields was achieved without accounting for backscatter into the beam monitor chamber. For the SBRT VMAT plans, the agreement between Monte Carlo and ion chamber point dose measurements was within 1%. Excellent agreement between Monte Carlo, treatment planning system and Gafchromic film dose distribution was observed with over 99% of the points in the high dose volume passing the 3%, 3 mm gamma test. CONCLUSIONS: The authors have presented a method for making the Varian IAEA compliant 6 MV FFF phase space file of the TrueBeam linac compatible with BEAMnrc/DOSXYZnrc. After benchmarking the modified phase space against measurement, they have demonstrated its potential for use in MC based quality assurance of complex delivery techniques.


Asunto(s)
Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Radiocirugia , Reproducibilidad de los Resultados , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA