Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39190065

RESUMEN

PURPOSE: The emergency treatment of unstable pelvic ring injuries is still a challenge and requires surgical and anesthesiological resuscitation. Emergency fixation of the unstable pelvic ring with percutaneous sacroiliac (SI) screws, also known as "Rescue Screws", is an established treatment method. The aim of our study was to compare the outcome and complication rates of "Rescue Screws" with elective SI-screw fixations. METHODS: A 1:1 ratio nearest-neighbor matched, retrospective cohort study of trauma patients with acute pelvic ring injuries at a level one trauma center was performed. Patients ≥ 15 years, treated with SI-screw fixation were included. EXCLUSION CRITERIA: pathologic fractures, missing consent and navigated procedures. The primary outcome parameters was defined as SI-screw revision operations. Patients were stratified according to treatment strategy (RS: Rescue Screws; EL: elective SI-screws). RESULTS: From 392 patients identified between 11/2014 and 08/2021, 186 met the inclusion criteria with 41 in the RS Group and 145 in the EL group. After matching, 41 patients were included in each group with similar baseline characteristics except persistent hemodynamic shock (RS: n = 22 (53.37%) vs. EL: n = 1 (4.3%), p < 0.001). Surgical characteristics were comparable in terms of instrumentation levels and insertion-sites. No significant differences were observed in the outcome parameters (revisions, reoperations, implant-associated complications, LOS and mortality) between both groups. CONCLUSION: Treatment of unstable pelvic ring fractures with Rescue Screws appears as a feasible treatment option for emergency stabilization. Rescue Screws are not associated with elevated revision rates and increased complications rates. This minimally invasive technique enables safe emergency stabilization of the posterior pelvic ring. Prospective or randomized clinical trials are required to directly compare Rescue Screws with other competing emergency stabilization techniques.

2.
Medicina (Kaunas) ; 60(6)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38929461

RESUMEN

Background and Objectives: Despite the established role of subtalar joint arthrodesis (SJA) for treatment of subtalar osteoarthritis, achieving bone union remains challenging, with up to 46% non-union rates. Adequate compression and stable fixation are crucial for successful outcomes, with internal screw fixation being the gold standard for SJA. The delta configuration, featuring highly divergent screws, offers stability, however, it can result in hardware irritation in 20-30% of patients. Solutions to solve this complication include cannulated compression screw (CCS) countersinking or cannulated compression headless screw (CCHS) application. The aim of this biomechanical study was to investigate the stability of a delta configuration for SJA utilizing either a combination of a posterior CCHS and an anterior CCS or a standard two-CCS combination. Materials and Methods: Twelve paired human cadaveric lower legs were assigned pairwise to two groups for SJA using either two CCSs (Group 1) or one posterior CCHS and one anterior CCS (Group 2). All specimens were tested under progressively increasing cyclic loading to failure, with monitoring of the talocalcaneal movements via motion tracking. Results: Initial stiffness did not differ significantly between the groups, p = 0.949. Talocalcaneal movements in terms of varus-valgus deformation and internal-external rotation were significantly bigger in Group 1 versus Group 2, p ≤ 0.026. Number of cycles until reaching 5° varus-valgus deformation was significantly higher in Group 2 versus Group 1, p = 0.029. Conclusions: A delta-configuration SJA utilizing a posterior CCHS and an anterior CCS is biomechanically superior versus a standard configuration with two CCSs. Clinically, the use of a posterior CCHS could prevent protrusion of the hardware in the heel, while an anterior CCS could facilitate less surgical time and thus less complication rates.


Asunto(s)
Artrodesis , Tornillos Óseos , Cadáver , Articulación Talocalcánea , Humanos , Artrodesis/métodos , Artrodesis/instrumentación , Articulación Talocalcánea/cirugía , Fenómenos Biomecánicos , Masculino , Femenino , Anciano , Osteoartritis/cirugía , Persona de Mediana Edad
3.
PLoS One ; 19(6): e0300256, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38829845

RESUMEN

PURPOSE: Due to the increase in life expectancy and high-energy traumas, anterior column acetabular fractures (ACFs) are also increasing. While open reduction and internal fixation (ORIF) is still the standard surgical procedure, minimally invasive, percutaneous fixation of osteoporotic acetabulum fractures (AF) are growing in popularity. The aim of this biomechanical study was to evaluate the biomechanical competence following antegrade fixation with a standard screw versus a cannulated compression headless screw. METHODS: Eight anatomical osteoporotic composite pelvises were given an anterior column fracture. Two groups of eight specimens each (n = 8) for fixation with either a 6.5 mm cannulated compression headless screw in group Anterior Acetabulum Canulated Compression Headless Screw (AACCH), or with a 6.5 mm partially threaded cannulated screw in group Anterior Acetabulum Standard Screw (AASS) where compared. Each specimen was biomechanically loaded cyclically at a rate of 2 Hz with monotonically increasing compressive load until failure. Motions were assessed by means of optical motion tracking. RESULTS: Initial construct stiffness trended higher in group AACCH at 152.4 ± 23.1 N/mm compared to group AASS at 118.5 ± 34.3 N/mm, p = 0.051. Numbers of cycles and corresponding peak load at failure, were significantly higher in group AACCH at 6734 ± 1669 cycles and 873.4 ± 166.9 N versus group AASS at 4440 ± 2063 cycles and 644.0 ± 206.3 N, p = 0.041. Failure modes were breakout of the screws around the proximal entry point. CONCLUSION: From a biomechanical perspective, group AACCH was associated with superior biomechanical competence compared to standard partially threaded cannulated screws and could therefore be considered as valid alternative for fixation of anterior acetabulum fractures.


Asunto(s)
Acetábulo , Tornillos Óseos , Fijación Interna de Fracturas , Acetábulo/cirugía , Acetábulo/lesiones , Humanos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Osteoporosis/cirugía , Osteoporosis/fisiopatología , Osteoporosis/complicaciones
4.
Front Med (Lausanne) ; 11: 1345310, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38646559

RESUMEN

Background: The aim of the study was to determine the impact that PHTLS® course participation had on self-confidence of emergency personnel, regarding the pre-hospital treatment of patients who had suffered severe trauma. Furthermore, the goal was to determine the impact of specific medical profession, work experience and prior course participation had on the benefits of PHTLS® training. Methods: A structured questionnaire study was performed. Healthcare providers from local emergency services involved in pre-hospital care in the metropolitan area of Zurich (Switzerland, Europe) who completed a PHTLS® course were included. Altered self-confidence, communication, and routines in the treatment of severe trauma patients were examined. The impact of prior course participation, work experience and profession on course benefits were evaluated. Results: The response rate was 76%. A total of 6 transport paramedics (TPs), 66 emergency paramedics (EPs) and 15 emergency doctors (EDs) were included. Emergency paramedics had significantly more work experience compared with EDs (respectively 7.1 ± 5.7 yrs. vs. 4.5 ± 2.1 yrs., p = 0.004). 86% of the participants reported increased self-confidence in the pre-hospital management of severe trauma upon PHTLS® training completion. Moreover, according to 84% of respondents, extramural treatment of trauma changed upon course completion. PHTLS® course participants had improved communication in 93% of cases. This was significantly more frequent in EPs than TPs (p = 0.03). Multivariable analysis revealed emergency paramedics benefit the most from PHTLS® course participation. Conclusion: The current study shows that PHTLS® training is associated with improved self-confidence and enhanced communication, with regards to treatment of severe trauma patients in a pre-hospital setting, among medical emergency personnel. Additionally, emergency paramedics who took the PHTLS® course improved in overall self-confidence. These findings imply that all medical personal involved in the pre-hospital care of trauma patients, in a metropolitan area in Europe, do benefit from PHTLS® training. This was independent of the profession, previous working experience or prior alternative course participation.

5.
J Trauma Acute Care Surg ; 96(6): 931-937, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38196119

RESUMEN

BACKGROUND: The timing of definitive surgery in multiple injured patients remains a topic of debate, and multiple concepts have been described. Although these included injury severity as a criterion to decide on the indications for surgery, none of them considered the influence of injury distributions. We analyzed whether injury distribution is associated with certain surgical strategies and related outcomes in a cohort of patients treated according to principles of early and safe fixation strategies. METHODS: In this retrospective cohort study, multiple injured patients were included if they were primarily admitted to a Level I trauma center, had an Injury Severity Score of ≥16 points, and required surgical intervention for major injuries and fractures. The primary outcome measure was treatment strategy. The treatment strategy was classified according to the timing of definitive surgery after injury: early total care (ETC, <24 hours), safe definitive surgery (SDS, <48 hours), and damage control (DC, >48 hours). Statistics included univariate and multivariate analyses of mortality and the association of injury distributions and surgical tactics. RESULTS: Between January 1, 2016, and December 31, 2022, 1,471 patients were included (mean ± SD age, 55.6 ± 20.4 years; mean Injury Severity Score, 23.1 ± 11.4). The group distribution was as follows: ETC, n = 85 (5.8%); SDS, n = 665 (45.2%); and DC, n = 721 (49.0%); mortality was 22.4% in ETC, 16.1% in SDS, and 39.7% in DC. Severe nonlethal abdominal injuries (odds ratio [OR], 2.2; 95% confidence interval [CI], 1.4-3.5) and spinal injuries (OR, 1.6; 95% CI, 1.2-2.2) were associated with ETC, while multiple extremity injuries were associated with SDS (OR, 1.7; 95% CI, 1.4-2.2). Severe traumatic brain injury was associated with DC (OR, 1.3; 95% CI, 1.1-1.4). When a correction for the severity of head, abdominal, spinal, and extremity injuries, as well as differences in the values of admission pathophysiologic parameters were undertaken, the mortality was 30% lower in the SDS group when compared with the DC group (OR, 0.3; 95% CI, 0.2-0.4). CONCLUSION: Major spinal injuries and certain abdominal injuries, if identified as nonlethal, trigger definitive surgeries in the initial setting. In contrast, severe TBI was associated with delayed fracture care. Patients with major fractures and other injuries were treated by SDS (definitive care, <48 hours) when the pathophysiological response was adequate. The choice of a favorable surgical treatment appears to depend on injury patterns and physiological patient responses. LEVEL OF EVIDENCE: Therapeutic/Care Management; Level IV.


Asunto(s)
Puntaje de Gravedad del Traumatismo , Traumatismo Múltiple , Centros Traumatológicos , Humanos , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Traumatismo Múltiple/cirugía , Traumatismo Múltiple/mortalidad , Centros Traumatológicos/estadística & datos numéricos , Adulto , Anciano , Tiempo de Tratamiento/estadística & datos numéricos
6.
Eur J Trauma Emerg Surg ; 50(3): 1119-1125, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38261076

RESUMEN

PURPOSE: Clinical assessment of the major trauma patient follows international validated guidelines without standardized trauma-specific assessment of the lower extremities for injuries. This study aimed to validate a novel clinical test for lower extremity evaluation during trauma resuscitation phase. METHODS: This diagnostic, prognostic observational cohort study was performed on trauma patient treated at one level I trauma center between Mar 2022 and Mar 2023. The Straight-Leg-Evaluation-Trauma (SILENT) test follows three steps during the primary survey: inspection for obvious fractures (e.g., open fracture), active elevation of the leg, and cautious elevation of the lower extremity from the heel. SILENT was considered positive when obvious fracture was present and painful or pathological mobility was observed. The SILENT test was compared with standardized radiographs (CT scan or X-ray) as the reference test for fractures. Statistical analysis included sensitivity, specificity, and receiver operating characteristic testing. RESULTS: 403 trauma bay patients were included, mean age 51.6 (SD 21.2) years with 83 fractures of the lower extremity and 27 pelvic/acetabular fractures. Overall sensitivity was 75% (95%CI 64 to 84%), and overall specificity was 99% (95%CI 97 to 100%). Highest sensitivity was for detection of tibia fractures (93%, 95%CI 77 to 99%). Sensitivity of SILENT was higher in the unconscious patient (96%, 95%CI 78 to 100%) with a near 100% specificity. AUC was highest for tibia fractures (0.96, 95%CI 0.92 to 1.0) followed by femur fractures (0.92, 95%CI 0.84 to 0.99). CONCLUSION: The SILENT test is a clinical applicable and feasible rule-out test for relevant injuries of the lower extremity. A negative SILENT test of the femur or the tibia might reduce the requirement of additional radiological imaging. Further large-scale prospective studies might be required to corroborate the beneficial effects of the SILENT test.


Asunto(s)
Centros Traumatológicos , Humanos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Fracturas Óseas/diagnóstico por imagen , Traumatismos de la Pierna/diagnóstico por imagen , Sensibilidad y Especificidad , Extremidad Inferior/lesiones , Extremidad Inferior/diagnóstico por imagen , Anciano , Examen Físico , Puntaje de Gravedad del Traumatismo
7.
J Shoulder Elbow Surg ; 33(2): 409-416, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37748530

RESUMEN

BACKGROUND: Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and a less prominent and optimized plate-to-bone fit design. On the other hand, minifragment plates in dual plating mode have demonstrated promising clinical results. The aim of the current study was to compare the biomechanical competence of single superior plating using the new-generation plate vs. dual plating using low-profile minifragment plates. METHODS: Sixteen paired human cadaveric clavicles were pairwise assigned to 2 groups for instrumentation with either a superior 2.7-mm variable-angle locking compression plate (group 1), or with one 2.5-mm anterior combined with one 2.0-mm superior matrix mandible plate (group 2). An unstable clavicle shaft fracture (AO/OTA 15.2C) was simulated by means of a 5-mm osteotomy gap. Specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis, and monitored via motion tracking. RESULTS: Initial construct stiffness was significantly higher in group 2 (9.28 ± 4.40 N/mm) compared to group 1 (3.68 ± 1.08 N/mm), P = .003. The amplitudes of interfragmentary motions in terms of axial and shear displacement, fracture gap opening and torsion, over the course of 12,500 cycles were significantly higher in group 1 compared to group 2, P ≤ .038. Cycles to 2 mm shear displacement were significantly lower in group 1 (22,792 ± 4346) compared to group 2 (27,437 ± 1877), P = .047. CONCLUSION: From a biomechanical perspective, low-profile 2.5/2.0-mm dual plates could be considered as a useful alternative for diaphyseal clavicle fracture fixation, especially in less common unstable fracture configurations.


Asunto(s)
Clavícula , Fracturas Óseas , Humanos , Clavícula/cirugía , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Tornillos Óseos , Placas Óseas
8.
J Orthop Res ; 42(4): 886-893, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37975265

RESUMEN

Dual plating of comminuted distal femoral fractures allows for early patient mobilization. An additional helically shaped medial plate avoids the medial vital structures of the thigh. The aim of this study is to investigate the biomechanical competence of an augmented lateral locking compression plate distal femur (LCP-DF) using an additional straight versus a helically shaped medial LCP of the same length. Ten pairs of human cadaveric femora were instrumented with a lateral anatomical 15-hole LCP-DF. Following, they were pairwise instrumented with either an additional medial straight 14-hole LCP (group 1) or a 90°-helical shape LCP (group 2). All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading until failure. Initial interfragmentary axial displacement and flexion under static compression were significantly smaller in group 1 (0.11 ± 0.12 mm and 0.21 ± 0.10°) versus group 2 (0.31 ± 0.14 mm and 0.68 ± 0.16°), p ≤ 0.007. Initial varus deformation under static compression remained not significantly different between group 1 (0.57 ± 0.23°) and group 2 (0.75 ± 0.34°), p = 0.085. Flexion movements during dynamic loading were significantly bigger in group 2 (2.51 ± 0.54°) versus group 1 (1.63 ± 1.28°), p = 0.015; however, no significant differences were observed in terms of varus, internal rotation, and axial and shear displacements between the groups, p ≥ 0.204. Cycles to failure and load at failure were higher in group 2 (25,172 ± 6376 and 3017 ± 638 N) compared to group 1 (22,277 ± 4576 and 2728 ± 458 N) with no significant differences between them, p = 0.195. From a biomechanical perspective, helical double plating may be considered a useful alternative to straight double plating, demonstrating ameliorated damping capacities during flexion deformation and safer application as the medial neurovascular structures of the thigh are avoided.


Asunto(s)
Fracturas del Fémur , Fijación Interna de Fracturas , Humanos , Fenómenos Biomecánicos , Fémur/cirugía , Placas Óseas , Extremidad Inferior
9.
Injury ; 55(2): 111214, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38029680

RESUMEN

BACKGROUND: 3D-navigation for percutaneous sacroiliac (SI) screw fixation is becoming increasingly common and several studies report great advantages of this technology. However, there is still limited clinical evidence on the efficacy regarding radiation exposure for patient and personnel. METHODS: This is a retrospective, single-center cohort study. All patients who underwent percutaneous sacroiliac screw fixation for an injury of the posterior pelvic ring from 2014 to 2021 were screened. Inclusion criteria were: conclusive radiation dosage reports, signed informed consent, a twelve month follow up and a complete data set. Patients were stratified in two groups (3D-navigation (Group 3D-N) vs. control (Group F)) based on the imaging modality used. Primary outcomes were radiation exposure for patient and personnel. Secondary outcomes were reoperations, complications, and intraoperative precision. RESULTS: Of 392 patients screened, 174 patients (3D-N: n = 50, F: n = 124) could be included for final analysis. We noted a significant reduction of the dose corresponding to potential radiation exposure for medical personnel (-15.3 mGy, 95 %CI: -2.1 to -28.5, p = 0.0232), but also a significant increase of the dose quantifying radiation exposure for patients (+77.0 mGy, 95 %CI: +53.3 to +100.6, p < 0.0001), when using navigation. In addition, the rate of radiographic malplacement was significantly reduced (F: 11.3% vs. 3D-N: 0 %, p = 0.0113) despite a substantial increase in transsacral screw placement (F: 19.4% vs. 3D-N: 76 %). CONCLUSION: Our data clearly suggests that the use of 3D-navigation for percutaneous SI screw fixation decreases radiation exposure for medical personnel, while increasing radiation exposure for patients. Furthermore, intraoperative precision is improved, even in more challenging operations.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Exposición a la Radiación , Cirugía Asistida por Computador , Humanos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Estudios de Cohortes , Estudios Retrospectivos , Cirugía Asistida por Computador/métodos , Tornillos Óseos , Exposición a la Radiación/prevención & control , Fluoroscopía/métodos , Huesos Pélvicos/lesiones
10.
Int Orthop ; 48(3): 643-649, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38015209

RESUMEN

PURPOSE: The number of seven required throws per knot was previously reported as providing sufficient security against slippage. A novel high-strength suture featuring dynamic tightening may allow for throw number reduction without compromising stability. The aims of this study were to (1) investigate the influence of the throw number and the effect of different ambient conditions on the knot security of two different high-strength sutures, and (2) compare their biomechanical competence. METHODS: Two sutures (FiberWire (FW) and DynaCord (DC)) were considered for preparing alternating surgical knots. The specimens were stratified for exposure to different media during biomechanical testing-namely air (dry), saline solution (wet), and fat (fatty-wet). A monotonic tensile ramp loading to failure was applied in each test run. For each suture and ambient condition, seven specimens with three to seven throws each were tested (n = 7), evaluating their slippage and ultimate force to failure. The minimum number of throws preventing suture unraveling was determined for each suture type and condition. RESULTS: For each suture type and condition, failure occurred via rupture in all specimens for the following minimum number of throws: FW-dry-7, wet-7, fatty-wet-7; DC-dry-6, wet-4, fatty-wet-5. When applying seven throws, FW demonstrated significantly larger slippage (6.5 ± 2.2 mm) versus DC (3.5 ± 0.4 mm) in wet (p = 0.004) but not in dry and fatty-wet conditions (p ≥ 0.313). CONCLUSIONS: The lower number of throws providing knot security of DC versus FW in the more realistic wet and fatty-wet conditions indicates that the novel DC suture may allow to decrease the foreign body volume and save surgical time without compromising the biomechanical competence.


Asunto(s)
Técnicas de Sutura , Suturas , Humanos , Ensayo de Materiales , Resistencia a la Tracción , Rotura , Técnicas de Sutura/efectos adversos
11.
Global Spine J ; : 21925682231216082, 2023 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-37963389

RESUMEN

STUDY DESIGN: Retrospective database analysis. OBJECTIVE: Polytraumatized patients with spinal injuries require tailor-made treatment plans. Severity of both spinal and concomitant injuries determine timing of spinal surgery. Aim of this study was to evaluate the role of spinal injury localization, severity and concurrent injury patterns on timing of surgery and subsequent outcome. METHODS: The TraumaRegister DGU® was utilized and patients, aged ≥16 years, with an Injury Severity Score (ISS) ≥16 and diagnosed with relevant spinal injuries (abbreviated injury scale, AIS ≥ 3) were selected. Concurrent spinal and non-spinal injuries were analysed and the relation between injury severity, concurrent injury patterns and timing of spinal surgery was determined. RESULTS: 12.596 patients with a mean age of 50.8 years were included. 7.2% of patients had relevant multisegmental spinal injuries. Furthermore, 50% of patients with spine injuries AIS ≥3 had a more severe non-spinal injury to another body part. ICU and hospital stay were superior in patients treated within 48 hrs for lumbar and thoracic spinal injuries. In cervical injuries early intervention (<48 hrs) was associated with increased mortality rates (9.7 vs 6.3%). CONCLUSIONS: The current multicentre study demonstrates that polytrauma patients frequently sustain multiple spinal injuries, and those with an index spine injury may therefore benefit from standardized whole-spine imaging. Moreover, timing of surgical spinal surgery and outcome appear to depend on the severity of concomitant injuries and spinal injury localization. Future prospective studies are needed to identify trauma characteristics that are associated with improved outcome upon early or late spinal surgery.

12.
Clin Biomech (Bristol, Avon) ; 110: 106119, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37832469

RESUMEN

BACKGROUND: Distal femoral fractures are commonly treated with lateral straight plates. However, the lateral approach may not always be desirable, and 180°-helical plates may be an alternative. AIM: To investigate the biomechanical competence of 180°-helical plating versus standard straight lateral plating of unstable fractures at the distal femur. METHODS: Twelve left artificial femora were instrumented with a 15-hole Locking Compression Plate-Distal Femur, using either 180°-helical plates (group 1) or conventional straight lateral plates (group 2). An unstable distal femoral fracture AO/OTA 33-A3.3 was simulated. All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading in internal rotation until failure. FINDINGS: Initial axial stiffness (N/mm) was significantly higher in group 1 (185.6 ± 50.1) compared to group 2 (56.0 ± 14.4), p < 0.001. Group 1 demonstrated significantly higher initial interfragmentary flexion (°) and significantly lower initial varus/valgus deformation (°) under 500 N static axial compression versus group 2 (2.76 ± 1.02 versus 0.87 ± 0.77 and 4.08 ± 1.49 versus 6.60 ± 0.47), p ≤ 0.005. Shear displacement (mm) under 6 Nm static torsion was significantly higher in group 1 versus group 2 in both internal (1.23 ± 0.28 versus 0.40 ± 0.42) and external (1.21 ± 0.40 versus 0.57 ± 0.33) rotation, p ≤ 0.013. Cycles to failure and failure load (N) (clinical/catastrophic) were significantly higher in group 1 (12,484 ± 2116/13,752 ± 1518 and 1748.4 ± 211.6/1875.2 ± 151.8) compared to group 2 (7853 ± 1262/9727 ± 836 and 1285.3 ± 126.2/1472.7 ± 83.6), p ≤ 0.001. INTERPRETATION: Although 180°-helical plating using a pre-contoured standard straight lateral plate was associated with higher shear and flexion movements, it demonstrated improved initial axial stability and resistance against varus/valgus deformation compared to straight lateral plating. Moreover, the helical plates were associated with significantly higher endurance to failure. From a biomechanical perspective, 180°-helical plating may be considered as a valuable alternative to standard straight lateral plating of unstable distal femoral fractures.


Asunto(s)
Fracturas Femorales Distales , Fracturas del Fémur , Humanos , Fracturas del Fémur/cirugía , Fenómenos Biomecánicos , Fijación Interna de Fracturas , Placas Óseas
13.
Clin Biomech (Bristol, Avon) ; 109: 106095, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37757678

RESUMEN

BACKROUND: The beneficial effects of unrestricted postoperative full weight bearing for elderly patients suffering hip fractures have been demonstrated. However, there is still existing disagreement regarding acetabular fractures.The aim of this biomechanical study was to evaluate the initial load bearing capabilities of different fixation constructs of anterior column fractures (ACFs) in osteoporotic bone. METHODS: Artificial pelvises with ACFs were assigned to three groups (n = 8) and fixed with either a 7.3 mm partially threaded antegrade cannulated screw (group AASS), an anteriorly placed 3.5 mm plate (group AAPF), or a press-fit acetabular cup with screw augmentation (group AACF). All specimens underwent ramped loading from 20 N preload to 200 N at a rate of 18 N/s, followed by progressively increasing cyclic testing at 2 Hz until failure performed at a rate of 0.05 N/cycle. Relative displacements of the bone fragments were monitored by motion tracking. FINDINGS: Initial stiffness (N/mm) was 118.5 ± 34.3 in group AASS, 100.4 ± 57.5 in group AAPF, and 92.9 ± 44.0 in group AACF, with no significant differences between the groups, p = 0.544. Cycles to failure were significantly higher in groups AACF (8364 ± 2243) and AAPF (7827 ± 2881) compared to group AASS (4440 ± 2063), p ≤ 0.041. INTERPRETATION: From a biomechanical perspective, the minimally invasive cup fixation with screw augmentation demonstrated comparable stability to plate osteosynthesis of ACFs in osteoporotic bone. The results of the present study do not allow to conclusively answer whether immediate full weight bearing following cup fixation shall be allowed. Given its similar performance to plate osteosynthesis, this remains rather an utopic wish and a more conservative approach deems more reasonable.


Asunto(s)
Fracturas Óseas , Fracturas de Cadera , Osteoporosis , Fracturas de la Columna Vertebral , Humanos , Anciano , Acetábulo/cirugía , Estudios de Factibilidad , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Fracturas de Cadera/cirugía , Tornillos Óseos , Placas Óseas
14.
Eur J Trauma Emerg Surg ; 49(6): 2569-2578, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37555991

RESUMEN

BACKGROUND/PURPOSE: The surgical fixation of a symphyseal diastasis in partially or fully unstable pelvic ring injuries is an important element when stabilizing the anterior pelvic ring. Currently, open reduction and internal fixation (ORIF) by means of plating represents the gold standard treatment. Advances in percutaneous fixation techniques have shown improvements in blood loss, surgery time, and scar length. Therefore, this approach should also be adopted for treatment of symphyseal injuries. The technique could be important since failure rates, following ORIF at the symphysis, remain unacceptably high. The aim of this biomechanical study was to assess a semi-rigid fixation technique for treatment of such anterior pelvic ring injuries versus current gold standards of plate osteosynthesis. METHODS: An anterior pelvic ring injury type III APC according to the Young and Burgess classification was simulated in eighteen composite pelvises, assigned to three groups (n = 6) for fixation with either a single plate, two orthogonally positioned plates, or the semi-rigid technique using an endobutton suture implant. Biomechanical testing was performed in a simulated upright standing position under progressively increasing cyclic loading at 2 Hz until failure or over 150,000 cycles. Relative movements between the bone segments were captured by motion tracking. RESULTS: Initial quasi-static and dynamic stiffness, as well as dynamic stiffness after 100,000 cycles, was not significantly different among the fixation techniques (p ≥ 0.054).). The outcome measures for total displacement after 20,000, 40,000, 60,000, 80,000, and 100,000 cycles were associated with significantly higher values for the suture technique versus double plating (p = 0.025), without further significant differences among the techniques (p ≥ 0.349). Number of cycles to failure and load at failure were highest for double plating (150,000 ± 0/100.0 ± 0.0 N), followed by single plating (132,282 ± 20,465/91.1 ± 10.2 N), and the suture technique (116,088 ± 12,169/83.0 ± 6.1 N), with significantly lower values in the latter compared to the former (p = 0.002) and no further significant differences among the techniques (p ≥ 0.329). CONCLUSION: From a biomechanical perspective, the semi-rigid technique for fixation of unstable pubic symphysis injuries demonstrated promising results with moderate to inferior behaviour compared to standard plating techniques regarding stiffness, cycles to failure and load at failure. This knowledge could lay the foundation for realization of further studies with larger sample sizes, focusing on the stabilization of the anterior pelvic ring.


Asunto(s)
Fracturas Óseas , Sínfisis Pubiana , Humanos , Sínfisis Pubiana/cirugía , Sínfisis Pubiana/lesiones , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Pelvis , Placas Óseas
15.
Medicina (Kaunas) ; 59(8)2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37629669

RESUMEN

Background and purpose: Cannulated screws are standard implants for percutaneous fixa-tion of posterior pelvis ring injuries. The choice of whether to use these screws in combination with a washer is still undecided. The aim of this study was to evaluate the biomechanical competence of S1-S2 sacroiliac (SI) screw fixation with and without using a washer across three different screw designs. Material and Methods: Twenty-four composite pelvises were used and an SI joint injury type APC III according to the Young and Burgess classification was simulated. Fixation of the posterior pelvis ring was performed using either partially threaded short screws, fully threaded short screws, or fully threaded long transsacral screws. Biomechanical testing was performed under progressively increasing cyclic loading until failure, with monitoring of the intersegmental and bone-implant movements via motion tracking. Results: The number of cycles to failure and the corresponding load at failure (N) were significantly higher for the fully threaded short screws with a washer (3972 ± 600/398.6 ± 30.0) versus its counterpart without a washer (2993 ± 527/349.7 ± 26.4), p = 0.026. In contrast, these two parameters did not reveal any significant differences when comparing fixations with and without a washer using either partially threaded short of fully threaded long transsacral screws, p ≥ 0.359. Conclusions: From a biomechanical perspective, a washer could be optional when using partially threaded short or fully threaded long transsacral S1-S2 screws for treatment of posterior pelvis ring injuries in young trauma patients. Yet, the omission of the washer in fully threaded short screws could lead to a significant diminished biomechanical stability.


Asunto(s)
Técnicas Histológicas , Pelvis , Humanos , Pacientes , Programas Informáticos , Tornillos Óseos
16.
Medicina (Kaunas) ; 59(7)2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37512026

RESUMEN

Background and Objectives: Minimally invasive surgeries for acetabulum fracture fixation are gaining popularity due to their known advantages versus open reduction and internal fixation. Antegrade or retrograde screw fixation along the long axis of the posterior column of the acetabulum is increasingly applied in surgical practice. While there is sufficient justification in the literature for the application of the anterior approach, there is a deficit of reports related to the posterior approach. The aim of this study was to evaluate the biomechanical competence of posterior column acetabulum fracture fixation through antegrade screw placement using either a standard cannulated screw or a cannulated compression headless screw (CCHS) via posterior approach. Materials and Methods: Eight composite pelvises were used, and a posterior column acetabulum fracture according to the Letournel Classification was simulated on both their left and right sides via an osteotomy. The sixteen hemi-pelvic specimens were assigned to two groups (n = 8) for either posterior column standard screw (group PCSS) or posterior column CCHS (group PCCH) fixation. Biomechanical testing was performed by applying steadily increased cyclic load until failure. Interfragmentary movements were investigated by means of motion tracking. Results: Initial stiffness demonstrated significantly higher values in PCCH (163.1 ± 14.9 N/mm) versus PCSS (133.1 ± 27.5 N/mm), p = 0.024. Similarly, cycles and load at failure were significantly higher in PCCH (7176.7 ± 2057.0 and 917.7 ± 205.7 N) versus PCSS (3661.8 ± 1664.5 and 566.2 ± 166.5 N), p = 0.002. Conclusion: From a biomechanical perspective, CCHS fixation demonstrates superior stability and could be a valuable alternative option to the standard cannulated screw fixation of posterior column acetabulum fractures, thus increasing the confidence in postoperative full weight bearing for both the patient and treating surgeon. Whether uneventful immediate postoperative full weight bearing can be achieved with CCHS fixation should primarily be investigated in further human cadaveric studies with a larger sample size.


Asunto(s)
Fracturas Óseas , Fracturas de Cadera , Fracturas de la Columna Vertebral , Humanos , Fracturas Óseas/cirugía , Acetábulo/cirugía , Fijación Interna de Fracturas , Tornillos Óseos , Fenómenos Biomecánicos
17.
PLoS One ; 18(6): e0284320, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37294793

RESUMEN

BACKGROUND: Geriatric trauma patients represent a special challenge in postoperative care and are prone to specific complications. The goal of this study was to analyse the predictive potential of a novel nursing assessment tool, the outcome-oriented nursing assessment for acute care (ePA-AC), in geriatric trauma patients with proximal femur fractures (PFF). METHODS: A retrospective cohort study of geriatric trauma patients aged ≥ 70 years with PFF was conducted at a level 1 trauma centre. The ePA-AC is a routinely used tool that evaluates pneumonia; confusion, delirium and dementia (CDD); decubitus (Braden Score); the risk of falls; the Fried Frailty index (FFI); and nutrition. Assessment of the novel tool included analysis of its ability to predict complications including delirium, pneumonia and decubitus. RESULTS: The novel ePA-AC tool was investigated in 71 geriatric trauma patients. In total, 49 patients (67.7%) developed at least one complication. The most common complication was delirium (n = 22, 44.9%). The group with complications (Group C) had a significantly higher FFI compared with the group without complications (Group NC) (1.7 ± 0.5 vs 1.2 ± 0.4, p = 0.002). Group C had a significantly higher risk score for malnutrition compared with Group NC (6.3 ± 3.4 vs 3.9 ± 2.8, p = 0.004). A higher FFI score increased the risk of developing complications (odds ratio [OR] 9.8, 95% confidence interval [CI] 2.0 to 47.7, p = 0.005). A higher CDD score increased the risk of developing delirium (OR 9.3, 95% CI 2.9 to 29.4, p < 0.001). CONCLUSION: The FFI, CDD, and nutritional assessment tools are associated with the development of complications in geriatric trauma patients with PFF. These tools can support the identification of geriatric patients at risk and might guide individualised treatment strategies and preventive measures.


Asunto(s)
Delirio , Fracturas Femorales Proximales , Humanos , Anciano , Estudios Retrospectivos , Delirio/etiología , Delirio/complicaciones , Factores de Riesgo , Estado Nutricional , Evaluación Geriátrica
18.
J Orthop Surg Res ; 18(1): 401, 2023 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-37268974

RESUMEN

PURPOSE: The incidence of acetabular fractures (AFs) is increasing in all industrial nations, with posterior column fractures (PCFs) accounting for 18.5-22% of these cases. Treating displaced AFs in elderly patients is a known challenge. The optimal surgical strategy implementing open reduction and internal fixation (ORIF), total hip arthroplasty (THA), or percutaneous screw fixation (SF), remains debated. Additionally, with either of these treatment methods, the post-surgical weight bearing protocols are also ambiguous. The aim of this biomechanical study was to evaluate construct stiffness and failure load following a PCF fixation with either standard plate osteosynthesis, SF, or using a screwable cup for THA under full weight bearing conditions. METHODS: Twelve composite osteoporotic pelvises were used. A PCF according to the Letournel Classification was created in 24 hemi-pelvis constructs stratified into three groups (n = 8) as follows: (i) posterior column fracture with plate fixation (PCPF); (ii) posterior column fracture with SF (PCSF); (iii) posterior column fracture with screwable cup fixation (PCSC). All specimens were biomechanically tested under progressively increasing cyclic loading until failure, with monitoring of the interfragmentary movements via motion tracking. RESULTS: Initial construct stiffness (N/mm) was 154.8 ± 68.3 for PCPF, 107.3 ± 41.0 for PCSF, and 133.3 ± 27.5 for PCSC, with no significant differences among the groups, p = 0.173. Cycles to failure and failure load were 7822 ± 2281 and 982.2 ± 428.1 N for PCPF, 3662 ± 1664 and 566.2 ± 366.4 N for PCSF, and 5989 ± 3440 and 798.9 ± 544.0 N for PCSC, being significantly higher for PCPF versus PCSF, p = 0.012. CONCLUSION: Standard ORIF of PCF with either plate osteosynthesis or using a screwable cup for THA demonstrated encouraging results for application of a post-surgical treatment concept with a full weight bearing approach. Further biomechanical cadaveric studies with larger sample size should be initiated for a better understanding of AF treatment with full weight bearing and its potential as a concept for PCF fixation.


Asunto(s)
Fracturas Óseas , Fracturas de Cadera , Fracturas de la Columna Vertebral , Humanos , Anciano , Acetábulo/cirugía , Acetábulo/lesiones , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Soporte de Peso , Placas Óseas , Fenómenos Biomecánicos
19.
BMC Musculoskelet Disord ; 24(1): 405, 2023 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-37210475

RESUMEN

BACKGROUND/PURPOSE: Impaired healing is a feared complication with devastating outcomes for each patient. Most studies focus on geriatric fracture fixation and assess well known risk factors such as infections. However, risk factors, others than infections, and impaired healing of proximal femur fractures in non-geriatric adults are marginally assessed. Therefore, this study aimed to identify non-infection related risk factors for impaired fracture healing of proximal femur fractures in non-geriatric trauma patients. METHODS: This study included non-geriatric patients (aged 69 years and younger) who were treated between 2013 and 2020 at one academic Level 1 trauma center due to a proximal femur fracture (PFF). Patients were stratified according to AO/OTA classification. Delayed union was defined as failed callus formation on 3 out of 4 cortices after 3 to 6 months. Nonunion was defined as lack of callus-formation after 6 months, material breakage, or requirement of revision surgery. Patient follow up was 12 months. RESULTS: This study included 150 patients. Delayed union was observed in 32 (21.3%) patients and nonunion with subsequent revision surgery occurred in 14 (9.3%). With an increasing fracture classification (31 A1 up to 31 A3 type fractures), there was a significantly higher rate of delayed union. Additionally, open reduction and internal fixation (ORIF) (OR 6.17, (95% CI 1.54 to 24.70, p ≤ 0.01)) and diabetes mellitus type II (DM) (OR 5.74, (95% CI 1.39 to 23.72, p = 0.016)), were independent risk factors for delayed union. The rate of nonunion was independent of fracture morphology, patient's characteristics or comorbidities. CONCLUSION: Increasing fracture complexity, ORIF and diabetes were found to be associated with delayed union of intertrochanteric femur fractures in non-geriatric patients. However, these factors were not associated with the development of nonunion.


Asunto(s)
Fracturas del Fémur , Fracturas Femorales Proximales , Adulto , Humanos , Curación de Fractura , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/epidemiología , Fracturas del Fémur/cirugía , Fémur , Factores de Riesgo , Estudios Retrospectivos , Fijación Interna de Fracturas/efectos adversos , Resultado del Tratamiento
20.
J Orthop Res ; 41(12): 2740-2748, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37246496

RESUMEN

Injuries of the posterior pelvic ring are predominantly associated with osteoporosis. Percutaneously placed screws transfixing the sacroiliac joint have become the gold standard for their treatment. However, screw cut-out, backing-out, and loosening are common complications. One promising option could be cerclage reinforcement of cannulated screw fixations. Therefore, the aim of this study was to evaluate the biomechanical feasibility of posterior pelvic ring injuries fixed with S1 and S2 transsacral screws augmented with cerclage. Twenty-four composite osteoporotic pelvises with posterior sacroiliac joint dislocation were stratified into four groups for S1-S2 transsacral fixation using either (1) fully threaded screws, (2) fully threaded screws with cable cerclage, (3) fully threaded screws with wire cerclage, or (4) partially threaded screws with wire cerclage. All specimens were biomechanically tested under progressively increasing cyclic loading until failure. Intersegmental movements were monitored by motion tracking. The transsacral partially threaded screw fixation with wire cerclage augmentation resulted in significantly less combined angular intersegmental movement in the transverse and coronal plane versus its fully threaded counterpart (p = 0.032), as well as in significantly less flexion versus all other fixations (p ≤ 0.029). Additional cerclage augmentation could be performed intraoperatively to improve the stability of posterior pelvic ring injuries treated with S1-S2 transsacral screw fixation. Further investigations should follow to consolidate the current results on real bones and possibly consider execution of a clinical study.


Asunto(s)
Fijación Interna de Fracturas , Sacro , Estudios de Factibilidad , Fijación Interna de Fracturas/métodos , Sacro/cirugía , Sacro/lesiones , Tornillos Óseos , Pelvis , Fenómenos Biomecánicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA