RESUMEN
PURPOSE: This study compared mid-term outcomes of two anterior cruciate ligament (ACL) restoration techniques within an early total surgical care of acute knee dislocation: repair with additional internal bracing (ACLIB) and reconstruction with autograft (ACLR). Initial results at 12 months demonstrated that ACLR offered superior stability compared to ACLIB. METHODS: Retrospective clinical study of patients with acute type III or IV KD. ACLIB or ACLR procedures were performed accompanied by simultaneous suture and internal bracing of the posterior cruciate ligament (PCL) and repair with lateral augmentation of the medial and lateral complex injuries utilizing Arciero's reconstruction technique. Patient-reported outcome measurements (PROMs), instrumental stability assessment via the Rolimeter-Test, and stress radiographs were analyzed. RESULTS: The study involved 20 patients (5 IIIM, 5 IIIL, and 10 IV injuries) with an average follow-up of 35.2 ± 7.4 months. Notable differences in anterior tibial translation on stress radiography favouring ACLR persisted at 24-month follow-up in side-to-side difference (SSD) (ACLIB 2.8 ± 2.5 mm vs. ACLR 0.3 ± 2.6 mm; p = 0.0487), but Rolimeter test variance diminished (SSD ACLIB 2.5 ± 0.9 mm vs. ACLR 1.8 ± 1.7 mm). Both groups showed excellent PROMs (Lysholm Score: ACLIB 84.4 ± 15.8 vs. ACLR 89.9 ± 9.0; IKDC Score: ACLIB 77.1 ± 16.2 vs. ACLR 77.7 ± 8.6). CONCLUSION: Our results indicate improved anterior stability at 12 months, which persisted at 24 months after ACL reconstruction compared with ACL repair by stress radiography. Both groups showed favourable patient-reported outcomes throughout the follow-up period. Notable rates of postoperative knee stiffness were observed in both groups. These were successfully managed with early, one-time arthroscopic arthrolysis within the first seven months of treatment, resulting in no major range of motion limitations at the 24-month follow-up. LEVEL OF EVIDENCE: Retrospective cohort study, III.
RESUMEN
PURPOSE: To characterize and compare the quality of regenerative cartilage tissue (ReCT) after conventional minced cartilage (CMC) and arthroscopic minced cartilage (AMC), in terms of cell viability, gene expression, and matrix synthesis and to investigate the influence of different shaver types. METHODS: Chondral tissue was harvested from the knees of 8 porcine donors. Porcine specimens were euthanized one day before harvest. AMC was created with 2 shaver blades in 2 operating modes (oscillating vs forward) and compared with a scalpel-fragmented CMC control. Before histologic analysis, 50% of the tissue was digested to prevent dedifferentiation of chondrocytes to fibroblasts. Cells were cultured and analyzed for cell viability, gene expression of cartilage-specific markers (aggrecan [ACAN], collagen type II, alpha1 [COL2A1], collagen type I, alpha1 [COL1A1], fibronectin-1 [FN1]), and matrix synthesis (Alcian-blue). RESULTS: AMC tissue contained fewer viable chondrocytes (41%-54% vs 91%; P = .001-.048) compared with CMC. After culture, CMC showed greater expressions of ACAN (27 virtual copy numbers [VCN]/housekeeping gene) and COL2A1 (30 VCN) compared with AMC (ACAN 2-9 VCN, COL2A1 2-7 VCN, P = .001-.039). AMC presented greater expressions of COL1A1 (9-21 VCN) and FN1 (12-17 VCN) than CMC (1 and 6 VCN, P = .001-.050). The signal intensity of the cartilage matrix formed by CMC (86/mm2) was greater than by AMC (7-10 mm2, P = .001-.032). CONCLUSIONS: CMC contained high numbers of viable chondrocytes, resulting in high-quality, hyaline-like ReCT. In contrast, AMC showed impaired chondrocyte quantity and viability, showing greater expressions of fibroblast markers and a decreased formation of mature cartilage matrix in porcine samples. The high chondrogenic potential of CMC to form hyaline-like ReCT was not confirmed for AMC. CLINICAL RELEVANCE: On the basis of our findings, arthroscopic harvest of minced cartilage leads to reduced chondrocyte viability and ReCT quality. Accordingly, CMC and AMC cannot be regarded as synonymous techniques, as arthroscopic techniques seem to be less efficacious.
RESUMEN
PURPOSE: The study aims to investigate the influence of patient- and fracture-specific factors on the occurrence of complications after osteosynthesis of patella fractures and to compare knee joint function, activity, and subjective pain levels after a regular postoperative course and after complications in the medium term. METHODS: This retrospective, multicenter cohort study examined patients who received surgery for patella fracture at level 1 trauma centers between 2013 and 2018. Patient demographics and fracture-specific variables were evaluated. Final follow-up assessments included patient-reported pain scores (NRS), subjective activity and knee function scores (Tegner Activity Scale, Lysholm score, IKDC score), complications, and revisions. RESULTS: A total of 243 patients with a mean follow-up of 63.4 ± 21.3 months were included. Among them, 66.9% of patients underwent tension band wiring (TBW), 19.0% received locking plate osteosynthesis (LPO), and 14.1% underwent screw osteosynthesis (SO). A total of 38 patients (15.6%) experienced complications (TBW: 16.7%; LPO: 15.2%; SO: 11.8%). Implant-related complications of atraumatic fragment dislocation and material insufficiency/dislocation, accounted for 50% of all complications, were significantly more common after TBW than LPO (p = 0.015). No patient-specific factor was identified as a general cause for increased complications. Overall, particularly following complications such as limited range of motion or traumatic refracture, functional knee scores were significantly lower and pain levels were significantly higher at the final follow-up when a complication occurred. Implant-related complications, however, achieved functional scores comparable to a regular postoperative course without complications after revision surgery. CONCLUSION: The present study demonstrated that implant-related complications occurred significantly more often after TBW compared to LPO. The complication rates were similar in all groups.
Asunto(s)
Fijación Interna de Fracturas , Fracturas Óseas , Rótula , Complicaciones Posoperatorias , Humanos , Fijación Interna de Fracturas/efectos adversos , Masculino , Femenino , Estudios Retrospectivos , Rótula/lesiones , Rótula/cirugía , Complicaciones Posoperatorias/epidemiología , Persona de Mediana Edad , Fracturas Óseas/cirugía , Adulto , Anciano , Placas Óseas , Tornillos Óseos , Fractura de RótulaRESUMEN
Tibial plateau fractures are mostly complex and surgically demanding joint fractures, which require a comprehensive understanding of the fracture morphology, ligamentous and neurovascular injuries, as well as the diagnostic and therapeutic options for an optimal clinical outcome. Therefore, a standardised and structured approach is required. The success of the treatment of tibial plateau fractures relies on the interdisciplinary cooperation between surgical and conservative physicians in an outpatient and inpatient setting, physical therapists, patients and service providers (health insurance companies, statutory accident insurance, pension providers). On behalf of the German Society for Orthopaedics and Trauma Surgery (DGOU), the German Trauma Society (DGU) and the Society for Arthroscopy and Joint Surgery (AGA), under the leadership of the Fracture Committee of the German Knee Society (DKG), a guideline for tibial plateau fractures was created, which was developed in several voting rounds as part of a Delphi process. Based on the current literature, this guideline is intended to make clear recommendations and outline the most important treatment steps in diagnostics, therapy and follow-up treatment. Additionally, 25 statements were revised by the authors in several survey rounds using the Likert scale in order to reach a final consensus.
RESUMEN
AIMS: Visualization of the subtalar joint surface in surgical management of calcaneal factures remains a big challenge and anatomic reduction of the articular surface is essential for a good clinical outcome. We hypothesize that video-assistance can provide superior fracture reduction compared to fluoroscopy and that nanoscopy (NSC) achieves more extensive visualization compared to fracturoscopy (FSC). METHODS: Ten human cadaveric feet with artificially pre-fractured intraarticular calcaneal fractures with involvement of the posterior facet were treated via a minimal invasive subtalar approach. After initial control of reduction by 2D fluoroscopy, the reduction was further analyzed intraoperatively by FSC and NSC. 3D Scan served as gold standard control of reduction. Need of revision of reduction after the different visualization techniques was recorded and the extent of visualization of the subtalar joint surface in the medio-lateral dimension was compared for FSC and NSC. To quantify access and visualization of the medial and posterior facet, a depth gauge was used to measure from laterally at the clinically widest portion of the calcaneus targeted to the sustentaculum tali. The distance in millimetres was referred to the complete medio-lateral distance seen on paracoronal CT at the widest portion of the calcaneus. RESULTS: Fracture analysis in preoperative CT-scans according to Sanders classification revealed four type IC, two IIA, three IIC and one IIIAC fractures. Mean visualization of the medial and posterior facet was significantly improved with NSC (30.4 ± 3.78 mm) compared to FSC (23.6 ± 6.17 mm) (p = 0.008). An imperfect reduction requiring revision was more often required with NSC compared to FSC. Insufficient reduction using video-assistance was found in two cases. CONCLUSION: In order to optimize subtalar joint reduction and congruency, video-assisted techniques, especially NSC, provide superior visualization and thus can improve reduction in the surgical treatment of intraarticular calcaneal fractures.
Asunto(s)
Traumatismos del Tobillo , Calcáneo , Fracturas Óseas , Fracturas Intraarticulares , Traumatismos de la Rodilla , Humanos , Artroscopía/métodos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Fracturas Intraarticulares/diagnóstico por imagen , Fracturas Intraarticulares/cirugía , Calcáneo/diagnóstico por imagen , Calcáneo/cirugía , Calcáneo/lesiones , Cadáver , Resultado del TratamientoRESUMEN
PURPOSE: The purpose of this study was to evaluate the osseointegration and radiological outcomes in patients after total hip arthroplasty, hypothesizing different load patterns with one cementless stem design and different CCD angles (CLS Spotorno femoral stem 125° vs 135°). METHODS: All cases of degenerative hip osteoarthritis fulfilling strict inclusion criteria were treated with cementless hip arthroplasty between 2008 and 2017. Ninety-two out of one hundred six cases were clinically and radiologically examined three and 12 months after implantation. Two groups with each 46 patients were rendered prospectively and compared in clinical (Harris Hip Score) and radiological outcome. RESULTS: At final follow-up, no significant difference regarding Harris Hip Score was detected between the two groups (mean 99.2 ± 3.7 vs. 99.3 ± 2.5; p = 0.73). Cortical hypertrophy was found in none of the patients. Stress shielding was seen in a total of 52 hips (n = 27 vs. n = 25; 57% of the 92 hips). No significant difference regarding stress shielding was detected when comparing both groups (p = 0.67). Significant bone density loss was detected in Gruen zone one and two in the 125° group. The 135° group showed significant radiolucency in Gruen zone seven. No overall radiological loosening or subsidence of the femoral component was observed. CONCLUSION: According to our results, the use of a femoral component with a 125° CCD angle versus a 135° CCD did not result in a different osseointegration and load transfer with a clinically relevant significance.
Asunto(s)
Artroplastia de Reemplazo de Cadera , Enfermedades Óseas Metabólicas , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Oseointegración , Prótesis de Cadera/efectos adversos , Estudios Prospectivos , Estudios de Seguimiento , Resultado del Tratamiento , Diseño de Prótesis , Enfermedades Óseas Metabólicas/etiologíaRESUMEN
INTRODUCTION: The aim of this study was to compare the reduction quality of the anterolateral (AL) and modified posterolateral approach (PL) in lateral tibial plateau fractures involving the posterior column and central segments. METHODS: Matched pairs of pre-fractured cadaveric tibial plateau fractures were treated by either AL approach (supine position) or PL approach (prone position). Reduction was controlled by fluoroscopy and evaluated as satisfying or unacceptable. Afterwards, the reduction was examined by 3D scan. RESULTS: 10 specimens (3 pairs 41B3.1, 2 pairs 41C3.3) were evaluated. PL approach achieved significantly (p 0.00472) better fracture reduction results (0.4 ± 0.7 mm) of the posterior column compared to the AL group (2.1 ± 1.4 mm). Fracture steps involving the central area of the lateral plateau were insufficiently reduced after fluoroscopy using both approaches. CONCLUSION: Optimal reduction of displaced tibial plateau fractures involving the posterolateral column necessitates a posterior approach, which can be conducted in prone or lateral positioning. The anterolateral approach is indicated in fractures with minor displacement of the posterolateral rim but fracture extension in the latero-central segments. In these cases, an additional video-assisted reduction or extended approaches are helpful.
Asunto(s)
Fracturas de la Tibia , Fracturas de la Meseta Tibial , Humanos , Fijación Interna de Fracturas , Placas Óseas , Tibia , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Cadáver , Resultado del TratamientoRESUMEN
Varus malalignment combined with an increased posterior tibial slope (PTS) in the ACL deficient knee is a frequent pathology; yet, treatment for this condition remains challenging. The presented biplanar osteotomy technique allows to simultaneously address both components of malalignment in a single step. A detailed preoperative planning is best achieved by means of a digital planning software and constant intraoperative imaging is performed to verify the correction angle. A bony wedge is resected along with the extension osteotomy according to the preoperative planning and the medial-opening tibial osteotomy site is filled with bone allograft. Two bicortical lag screws are placed in anterior-posterior direction to secure the extension osteotomy, whereas a plate fixation is used for the medial-open osteotomy.
Asunto(s)
Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía , Osteotomía/métodos , Placas ÓseasRESUMEN
(1) Background: In treating medial unicompartmental gonarthrosis, medial open wedge high tibial osteotomy (mOWHTO) reduces pain and is intended to delay a possible indication for joint replacement by relieving the affected compartment. This study aimed to investigate the influence of the osteotomy height with different hinge points in HTO in genu varum on the leg axis. (2) Methods: Fifty-five patients with varus lower leg alignment obtained full-weight bearing long-leg radiographs were analyzed. Different simulations were performed: Osteotomy height was selected at 3 and 4 cm distal to the tibial articular surface, and the hinge points were selected at 0.5 cm, 1 cm, and 1.5 cm medial to the fibular head, respectively. The target of each correction was 55% of the tibial plateau measured from the medial. Then, the width of the opening wedge was measured. Intraobserver and interobserver reliability were calculated. (3) Results: Statistically significant differences in wedge width were seen at an osteotomy height of 3 cm below the tibial plateau when the distance of the hinge from the fibular head was 0.5 cm to 1.5 cm (3 cm and 0.5 cm: 8.9 +/- 3.88 vs. 3 cm and 1.5 cm: 11.6 +/- 4.39 p = 0.012). Statistically significant differences were also found concerning the wedge width between the distances 0.5 to 1.5 cm from the fibular head at the osteotomy height of 4 cm below the tibial plateau. (4 cm and 0.5 cm: 9.0 +/- 3.76 vs. 4 cm and 1.5 cm: 11.4 +/- 4.27 p = 0.026). (4) Conclusion: A change of the lateral hinge position of 1 cm results in a change in wedge width of approximately 2 mm. If hinge positions are chosen differently in preoperative planning and intraoperatively, the result can lead to over- or under-correction.
RESUMEN
(1) The malposition of the femoral tunnel in medial patellofemoral ligament (MPFL) reconstruction can lead to length changes in the MPFL graft, and an increase in medial peak pressure in the patellofemoral joint. It is the cause of 36% of all MPFL revisions. According to Schöttle et al., the creation of the drill canal should be performed in a strictly lateral radiograph. In this study, it was hypothesized that positioning the image receptor to the knee during intraoperative fluoroscopy would lead to a relevant mispositioning of the femoral tunnel, despite an always adjusted true-lateral view. (2) A total of 10 distal femurs were created from 10 knee CT scans using a 3D printer. First, true-lateral fluoroscopies were taken from lateral to medial at a 25 cm (LM25) distance from the image receptor, then from medial to lateral at a 5 cm (ML5) distance. Using the method from Schöttle, the femoral origin of the MPFL was determined when the femur was positioned distally, proximally, superiorly, and inferiorly to the image receptor. (3) The comparison of the selected MPFL insertion points according to Schöttle et al. revealed that the initial determination of the point in the ML5 view resulted in a distal and posterior shift of the point by 5.3 mm ± 1.2 mm when the point was checked in the LM25 view. In the opposite case, when the MPFL insertion was initially determined in the LM25 view and then redetermined in the ML5 view, there was a shift of 4.8 mm ± 2.2 mm anteriorly and proximally. The further positioning of the femur (distal, proximal, superior, and inferior) showed no relevant influence. (4) For fluoroscopic identification of the femoral MPFL, according to Schöttle et al., attention should be paid to the position of the fluoroscopy in addition to a true-lateral view.
RESUMEN
BACKGROUND: Fractures of the patella can lead to substantial functional impairments due to its crucial function in the extensor mechanism of the knee joint. Patellar fractures are associated with a comparatively high complication rate depending on the osteosynthesis procedure used. Despite established diagnostics and various osteosynthesis procedures they are still a therapeutic challenge. OBJECTIVE: This article gives an overview of the change in the treatment of patellar fractures and highlights the importance of comprehensive diagnostics and fracture-adapted treatment, especially for the increasing fractures in old age. MATERIAL AND METHODS: Evaluation of the current literature, discussion of biomechanical and clinical studies and expert recommendations (guidelines) RESULTS: Tension band wiring is still the most commonly used procedure; however, it is associated with a high rate of implant-related complications and failure rates. In particular, multifragmented comminuted fractures can often not be adequately treated by tension band wiring. Anterior locking plates seem to be biomechanically and clinically superior. CONCLUSION: For a good functional result after a patellar fracture, the fracture morphology must be completely understood and the optimal choice of the osteosynthesis method is crucial. Distal (or proximal) pole fractures and the increasing number of osteoporotic fractures of old patients due to the demographic change, remain a therapeutic challenge and require special consideration in the selection of the osteosynthesis procedure.
Asunto(s)
Fracturas Óseas , Fracturas Conminutas , Traumatismos de la Rodilla , Hilos Ortopédicos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Fracturas Conminutas/cirugía , Humanos , Traumatismos de la Rodilla/cirugía , Rótula/cirugía , Complicaciones PosoperatoriasRESUMEN
BACKGROUND: The treatment of patella fractures is technically demanding. Although the radiological results are mostly satisfactory, this often does not correspond to the subjective assessment of the patients. The classical treatment with tension band wiring with Kwires has several complications. Fixed-angle plate osteosynthesis seems to be biomechanically advantageous. OBJECTIVE: Who is treating patella fractures in Germany? What is the current standard of treatment? Have modern forms of osteosynthesis become established? What are the most important complications? MATERIAL AND METHODS: The members of the German Society for Orthopedics and Trauma Surgery and the German Knee Society were asked to participate in an online survey. RESULTS: A total of 511 completed questionnaires were evaluated. Most of the respondents are specialized in trauma surgery (51.5%), have many years of professional experience and work in trauma centers. Of the surgeons 50% treat ≤5 patella fractures annually. In almost 40% of the cases preoperative imaging is supplemented by computed tomography. The classical tension band wiring with Kwires is still the preferred form of osteosynthesis for all types of fractures (transverse fractures 52%, comminuted fractures 40%). In the case of comminuted fractures 30% of the surgeons choose fixed-angle plate osteosynthesis. If the inferior pole is involved a McLaughlin cerclage is used for additional protection in 60% of the cases. DISCUSSION: The standard of care for patella fractures in Germany largely corresponds to the updated S2e guidelines. Tension band wiring is still the treatment of choice. Further (long-term) clinical studies are needed to verify the advantages of fixed-angle plates.
Asunto(s)
Fracturas Óseas , Fracturas Conminutas , Tornillos Óseos , Hilos Ortopédicos , Fijación Interna de Fracturas , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Alemania , Humanos , Rótula/diagnóstico por imagen , Rótula/cirugíaRESUMEN
PURPOSE: Given that tibial plateau fractures (TPF) are rare, they may pose a challenge to the treating surgeon due to their variety of complex fracture patterns. Numerous studies have identified potential fracture-specific, surgery-related, and patient-related risk factors for impaired patient outcomes. However, reports on the influence of bone metabolism on functional outcomes are missing. METHODS: In a retrospective multicenter cohort study, 122 TPF of 121 patients were analyzed with respect to radiological and clinical outcomes (Rasmussen) with a mean follow-up of 35.7 ± 24.9 months. The risk factor assessment included bone metabolism-affecting comorbidities and medication. RESULTS: The findings showed that 95.9% of the patients reported a good-to-excellent clinical outcome, and 97.4% reported a good-to-excellent radiological outcome. Logistic regression revealed that potentially impaired bone metabolism (IBM) was an independent risk factor for the clinical (p = 0.016) but not the radiological outcome (Table 4). Patients with 41-type B fractures and a potential IBM had a seven times higher risk to present a fair-to-poor clinical outcome [OR 7.45, 95 CI (4.30, 12.92)]. The most common objective impairment was a limited range of motion in 16.4% of the patients, especially in 41-type C fractures (p = 0.06). The individual failure analysis additionally identified surgery-related options for improvement. CONCLUSION: This study demonstrated that potential IBM was an independent risk factor for a poor-to-fair clinical outcome.
Asunto(s)
Fijación Interna de Fracturas/métodos , Articulación de la Rodilla/cirugía , Fracturas de la Tibia/metabolismo , Fracturas de la Tibia/cirugía , Adulto , Femenino , Curación de Fractura , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Fracturas de la Tibia/diagnóstico por imagenRESUMEN
PURPOSE: Longitudinal imaging studies are important in the translational process of stem cell-based therapies. Small animal imaging models are widely available and practical but insufficiently depict important morphologic detail. In contrary, large animal models are logistically challenging and costly but offer greater imaging quality. In order to combine the advantages of both, we developed an intermediate-sized rabbit animal model for cartilage imaging studies. PROCEDURES: Rabbit mesenchymal stem cells (rMSC) were isolated as primary cultures from the bone marrow of New Zealand white rabbits. rMSC were subsequentially transduced lentivirally with eGFP and magnetically labeled with the iron oxide ferucarbotran. eGFP expression was evaluated by flow cytometry and iron uptake was analyzed by isotope dilution mass spectrometry and Prussian blue staining. Fluorescence microscopy of eGFP-transduced rMSC was performed. Viability and induction of apoptosis were assessed by XTT and caspase-3/-7 measurements. The chondrogenic potential of labeled cells was quantified by glycosaminoglycan contents in TGF-ß3 induced pellet cultures. Labeled and unlabeled cells underwent magnetic resonance imaging (MRI) at 1.5 T before and after differentiation using T1-, T2-, and T2*-weighted pulse sequences. Relaxation rates were calculated. rMSCs were implanted in fibrin clots in osteochondral defects of cadaveric rabbit knees and imaged by 7 T MRI. T2* maps were calculated. Statistical analyses were performed using multiple regression models. RESULTS: Efficiency of lentiviral transduction was greater than 90 %. Fluorescence signal was dose dependent. Cellular iron uptake was significant for all concentrations (p < 0.05) and dose dependent (3.3-56.5 pg Fe/cell). Labeled rMSC showed a strong, dose-dependent contrast on all MR pulse sequences and a significant decrease in T2 and T2* relaxation rates. Compared with non-transduced or unlabeled controls, there were no adverse effects on cell viability, rate of apoptosis, or chondrogenic differentiation. MRI of labeled rMSCs in osteochondral defects showed a significant signal of the transplant with additional high-resolution anatomical information. CONCLUSIONS: This intermediate-sized rabbit model and its bifunctional labeling technique allow for improved depiction of anatomic detail for noninvasive in vivo rMSC tracking with MRI and for immunohistological correlation by fluorescence microscopy.
Asunto(s)
Imagen por Resonancia Magnética , Células Madre Mesenquimatosas/citología , Microscopía Fluorescente , Animales , Cartílago/patología , Diferenciación Celular , Supervivencia Celular , Condrocitos/citología , Medios de Contraste , Dextranos/química , Compuestos Férricos/química , Proteínas Fluorescentes Verdes/química , Lentivirus/metabolismo , Nanopartículas de Magnetita/química , Conejos , Coloración y EtiquetadoRESUMEN
Cartilage defects represent an increasing pathology among active individuals that affects the ability to contribute to sports and daily life. Cell therapy, such as autologous chondrocyte implantation (ACI), is a widespread option to treat larger cartilage defects still lacking standardization of in vitro cell culture parameters. We hypothesize that mRNA expression of cytokines and proteases before and after ACI is influenced by in vitro parameters: cell-passage, cell-density and membrane-holding time. Knee joint articular chondrocytes, harvested from rabbits (n = 60), were cultured/processed under varying conditions: after three different cell-passages (P1, P3, and P5), cells were seeded on 3D collagen matrices (approximately 25 mm³) at three different densities (2 × 105/matrix, 1 × 106/matrix, and 3 × 106/matrix) combined with two different membrane-holding times (5 h and two weeks) prior autologous transplantation. Those combinations resulted in 18 different in vivo experimental groups. Two defects/knee/animal were created in the trochlear groove (defect dimension: ∅ 4 mm × 2 mm). Four identical cell-seeded matrices (CSM) were assembled and grouped in two pairs: One pair giving pre-operative in vitro data (CSM-i), the other pair was implanted in vivo and harvested 12 weeks post-implantation (CSM-e). CSMs were analyzed for TNF-α, IL-1ß, MMP-1, and MMP-3 via qPCR. CSM-i showed higher expression of IL-1ß, MMP-1, and MMP-3 compared to CSM-e. TNF-α expression was higher in CSM-e. Linearity between CSM-i and CSM-e values was found, except for TNF-α. IL-1ß expression was higher in CSM-i at higher passage and longer membrane-holding time. IL-1ß expression decreased with prolonged membrane-holding time in CSM-e. For TNF-α, the reverse was true. Lower cell-passages and lower membrane-holding time resulted in stronger TNF-α expression. Prolonged membrane-holding time resulted in increased MMP levels among CSM-i and CSM-e. Cellular density was of no significant effect. We demonstrated cytokine and MMP expression levels to be directly influenced by in vitro culture settings in ACI. Linearity of expression-patterns between CSM-i and CSM-e may predict ACI regeneration outcome in vivo. Cytokine/protease interaction within the regenerate tissue could be guided via adjusting in vitro culture parameters, of which membrane-holding time resulted the most relevant one.
Asunto(s)
Condrocitos/citología , Condrocitos/trasplante , Matriz Extracelular/metabolismo , Inflamación/metabolismo , Inflamación/patología , Animales , Células Cultivadas , Condrocitos/metabolismo , Citocinas/metabolismo , Modelos Animales de Enfermedad , Mediadores de Inflamación/metabolismo , Metaloproteinasas de la Matriz/metabolismo , ARN Mensajero/genética , ARN Mensajero/metabolismo , Conejos , Trasplante AutólogoRESUMEN
BACKGROUND: Developmental hip dysplasia is the most common cause of secondary hip osteoarthritis. Due to severe acetabular bone deficiency, cup positioning in total hip arthroplasty (THA) of dysplastic hips remains a surgical challenge. The aim was to analyze the functional outcome of far proximal cup positions in primary THA. METHODS: Fifty patients (61 hips) with THA for severe dysplastic osteoarthritis and a far proximal cup position were included. Patients were divided according to the heights of the implanted cups with increasing vertical distance from the interteardrop line (group A: 55-65 mm, group B: 65-75 mm, group C: >75 mm). Functional outcome was assessed at latest follow-up (38 ± 16 months) by Lower Extremity Functional Score, Tegner Activity Score, and Harris Hip Score (HHS). Patients answered a Patient Satisfaction Questionnaire. Leg length discrepancy was estimated radiographically. RESULTS: The Lower Extremity Functional Score significantly decreased in C (45.3 ± 25) compared to A (66.7 ± 15.3) and B (67.9 ± 9.9). The Tegner Activity Score significantly increased in all subgroups from preoperative to postoperative (2.2 ± 1.3 to 4.1 ± 1.4; P < .05). The mean overall HHS was 89.3 ± 14.7 (A: 89.5 ± 14.3, B: 94.3 ± 6.5, C: 78.3 ± 22.1). The HHS domains of activity of daily life and gait were significantly reduced in C (P < .05). Patients described a high satisfaction level with the surgery. No significant differences were found with regard to preoperative and postoperative leg lengthening (P = .881). Neither dislocations, impingement problems nor neurologic complications were observed. CONCLUSION: Primary THA without any concomitant surgical interventions with a far proximal cup position offers a safe and effective treatment option in severe dysplastic hip osteoarthritis.
Asunto(s)
Artroplastia de Reemplazo de Cadera/rehabilitación , Luxación Congénita de la Cadera/cirugía , Osteoartritis de la Cadera/cirugía , Acetábulo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Femenino , Luxación de la Cadera/cirugía , Luxación Congénita de la Cadera/complicaciones , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/etiología , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: As dental imaging accounts for approximately 40â% of all X-ray examinations in Germany, profound knowledge of this topic is essential not only for the dentist but also for the clinical radiologist. This review focuses on basic imaging findings regarding the teeth. Therefore, tooth structure, currently available imaging techniques and common findings in conserving dentistry including endodontology, periodontology, implantology and dental trauma are presented. METHODS: Literature research on the current state of dental radiology was performed using Pubmed. RESULTS AND CONCLUSION: Currently, the most frequent imaging techniques are the orthopantomogram (OPG) and single-tooth radiograph, as well as computer tomography (CT) and cone beam CT mainly for implantology (planning or postoperative control) or trauma indications. Especially early diagnosis and correct classification of a dental trauma, such as dental pulp involvement, prevents from treatment delays or worsening of therapy options and prognosis. Furthermore, teeth are commonly a hidden focus of infection.Since radiologists are frequently confronted with dental imaging, either concerning a particular question such as a trauma patient or regarding incidental findings throughout head and neck imaging, further training in this field is more than worthwhile to facilitate an early and sufficient dental treatment. KEY POINTS: · This review focuses on dental imaging techniques and the most important pathologies.. · Dental pathologies may not only be locally but also systemically relevant.. · Reporting of dental findings is important for best patient care.. CITATION FORMAT: · Masthoff M, Gerwing M, Masthoff M etâal. Dental Imaging - A basic guide for the radiologist. Fortschr Röntgenstr 2019; 191: 192â-â198.
Asunto(s)
Enfermedades Dentales/diagnóstico por imagen , Traumatismos de los Dientes/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Caries Dental/diagnóstico por imagen , Caries Dental/terapia , Implantes Dentales , Pulpa Dental/diagnóstico por imagen , Pulpa Dental/lesiones , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Periodontitis/diagnóstico por imagen , Periodontitis/terapia , Periodoncio/diagnóstico por imagen , Radiografía Panorámica , Articulación Temporomandibular/diagnóstico por imagen , Diente/diagnóstico por imagen , Enfermedades Dentales/terapia , Traumatismos de los Dientes/terapiaRESUMEN
BACKGROUND: Quantitative Imaging of microcirculatory disorders is challenging. OBJECTIVE: To investigate the feasibility of 2D Fluorescence Optical Imaging (FOI) for characterization and quantification of microcirculatory disorders in peripheral arterial occlusive disease (PAOD) of the upper extremity. METHODS: 9 patients with various clinical presentations of PAOD of the upper extremity were included. Quantitative analysis of both hands was performed by assessing the fluorescence intensity of Indocyanine Green (ICG) dynamically over a time period of 360 seconds. Analysis of the signal intensity within multiple regions of both hands was calculated and time-dependent perfusion curves for each region of interest were plotted over time. RESULTS: Compared to the healthy, vascular non-impaired segments, pathological segments with an impaired tissue perfusion were identified through a decreased rate of early tissue enhancement (pâ=â0.02) and increased signal intensity of the optical perfusion agent per second (pâ<â0.001). The affected segments showed a decreased maximum signal intensity and a prolonged interval to reach the maximum signal intensity (time to peak). CONCLUSION: 2D FOI allows quantitative assessment of the peripheral microcirculation in various vascular pathophysiologies and is able to detect the impaired tissue perfusion in patients with vascular disorders of the upper extremity.
Asunto(s)
Fluorescencia , Microcirculación/genética , Imagen Óptica/métodos , Enfermedad Arterial Periférica/fisiopatología , Extremidad Superior/inervación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Extremidad Superior/patologíaRESUMEN
The distribution of intramyocardially injected rabbit MSCs, labeled with the near-infrared dye 1,1'-dioctadecyl-3,3,3',3'-tetramethylindotricarbo-cyanine-iodide (DiR) using hybrid Fluorescence Molecular Tomography-X-ray Computed Tomography (FMT-XCT) and Multispectral Optoacoustic Tomography (MSOT) imaging technologies, was investigated. Viability and induction of apoptosis of DiR labeled MSCs were assessed by XTT- and Caspase-3/-7-testing in vitro. 2 × 106, 2 × 105 and 2 × 104 MSCs labeled with 5 and 10 µg DiR/ml were injected into fresh frozen rabbit hearts. FMT-XCT, MSOT and fluorescence cryosection imaging were performed. Concentrations up to 10 µg DiR/ml did not cause apoptosis in vitro (p > 0.05). FMT and MSOT imaging of labeled MSCs led to a strong signal. The imaging modalities highlighted a difference in cell distribution and concentration correlated to the number of injected cells. Ex-vivo cryosectioning confirmed the molecular fluorescence signal. FMT and MSOT are sensitive imaging techniques offering high-anatomic resolution in terms of detection and distribution of intramyocardially injected stem cells in a rabbit model.
RESUMEN
OBJECTIVES: To assess labelling efficiency of rabbit mesenchymal stem cells (MSCs) using the near-infrared dye 1,1'-dioctadecyl-3,3,3',3'-tetramethylindotricarbocyanine iodide (DiR) and detection of labelled MSCs for osteochondral defect repair in a rabbit model using fluorescence molecular tomography-X-ray computed tomography (FMT-XCT). METHODS: MSCs were isolated from New Zealand White rabbits and labelled with DiR (1.25-20 µg/mL). Viability and induction of apoptosis were assessed by XTT- and Caspase-3/-7-testing. Chondrogenic potential was evaluated by measurement of glycosaminoglycans. Labelled cells and unlabeled controls (n = 3) underwent FMT-XCT imaging before and after chondrogenic differentiation. Osteochondral defects were created surgically in rabbit knees (n = 6). Unlabeled and labelled MSCs were implanted in fibrin-clots and imaged by FMT-XCT. Statistical analyses were performed using multiple regression models. RESULTS: DiR-labelling of MSCs resulted in a dose-dependent fluorescence signal on planar images in trans-illumination mode. No significant reduction in viability or induction of apoptosis was detected at concentrations below 10 µg DiR/mL (p > .05); the chondrogenic potential of MSCs was not affected (p > .05). FMT-XCT of labelled MSCs in osteochondral defects showed a significant signal of the transplant (p < .05) with additional high-resolution anatomical information about its osteochondral integration. CONCLUSIONS: FMT-XCT allows for detection of stem cell implantation within osteochondral regeneration processes. KEY POINTS: ⢠DiR-labelling of MSCs shows no toxic side effects or impairment of chondrogenesis. ⢠Fluorescence molecular tomography allows for detection of MSCs for osteochondral defect repair. ⢠FMT-XCT helps to improve evaluation of cell implantation and osteochondral regeneration processes.