Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
3.
Eur Heart J ; 45(10): 837-849, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-37956458

RESUMEN

BACKGROUND AND AIMS: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients. METHODS: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors. The primary efficacy outcome was a composite of stroke, systemic embolism, or cardiovascular death. The safety outcome was a composite of major bleeding and death. Key secondary outcomes were components of these outcomes and electrocardiogram (ECG)-diagnosed atrial fibrillation. RESULTS: Median follow-up of 2389 patients with core lab-verified AHRE was 1.8 years. AHRE ≥24 h were present at baseline in 259/2389 patients (11%, 78 ± 7 years old, 28% women, CHA2DS2-VASc 4). Clinical characteristics were not different from patients with shorter AHRE. The primary outcome occurred in 9/132 patients with AHRE ≥24 h (4.3%/patient-year, 2 strokes) treated with anticoagulation and in 14/127 patients treated with placebo (6.9%/patient-year, 2 strokes). Atrial high-rate episode duration did not interact with the efficacy (P-interaction = .65) or safety (P-interaction = .98) of anticoagulation. Analyses including AHRE as a continuous parameter confirmed this. Patients with AHRE ≥24 h developed more ECG-diagnosed atrial fibrillation (17.0%/patient-year) than patients with shorter AHRE (8.2%/patient-year; P < .001). CONCLUSIONS: This hypothesis-generating analysis does not find an interaction between AHRE duration and anticoagulation therapy in patients with device-detected AHRE and stroke risk factors. Further research is needed to identify patients with long AHRE at high stroke risk.


Asunto(s)
Fibrilación Atrial , Piridinas , Accidente Cerebrovascular , Tiazoles , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/diagnóstico , Atrios Cardíacos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/diagnóstico , Anticoagulantes/uso terapéutico
4.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38132643

RESUMEN

Unstable and symptomatic complete atrioventricular block represents a potentially fatal condition that requires prompt therapy while waiting for definitive pacemaker implantation. Although transcutaneous pacing is included in acute management, it could be a difficult approach due to its painfulness and the occasional failure of mechanical capture. Drug therapy is a feasible choice, and current guidelines encompass the use of atropine, dopamine, or epinephrine. Isoprenaline has never been investigated in this setting, and no specific indication of its use has been provided despite its potentially more favorable pharmacological profile. The study population included a consecutive series of patients who presented to the emergency department because of unstable third-degree atrioventricular block and were treated with either isoprenaline or dopamine infusion while waiting for definitive pacemaker implantation. Asymptomatic patients or those with reversible causes of complete atrioventricular block were excluded. The clinical response to the drug was deemed poor if, despite achieving a full drug dose, patients remained symptomatic and/or with hemodynamic instability, ventricular rate and rhythm did not improve or worsened, including if ventricular arrhythmias or asystolic pauses and/or irrepressible nausea/vomiting occurred. Isoprenaline infusion has proved to be safe and tolerated with no arrhythmia induction or hypotensive issues. Isoprenaline has also proven to be more satisfactory in achieving an effective clinical response in 84% of patients rather than dopamine (31%, p < 0.001), reducing the need for temporary artificial pacing. Our data point out the efficacy and safety of isoprenaline infusion and its greater tolerability over dopamine in the acute management of unstable third-degree AV block while waiting for definitive pacemaker implantation.

5.
N Engl J Med ; 389(13): 1167-1179, 2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37622677

RESUMEN

BACKGROUND: Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known. METHODS: We conducted an event-driven, double-blind, double-dummy, randomized trial involving patients 65 years of age or older who had AHREs lasting for at least 6 minutes and who had at least one additional risk factor for stroke. Patients were randomly assigned in a 1:1 ratio to receive edoxaban or placebo. The primary efficacy outcome was a composite of cardiovascular death, stroke, or systemic embolism, evaluated in a time-to-event analysis. The safety outcome was a composite of death from any cause or major bleeding. RESULTS: The analysis population consisted of 2536 patients (1270 in the edoxaban group and 1266 in the placebo group). The mean age was 78 years, 37.4% were women, and the median duration of AHREs was 2.8 hours. The trial was terminated early, at a median follow-up of 21 months, on the basis of safety concerns and the results of an independent, informal assessment of futility for the efficacy of edoxaban; at termination, the planned enrollment had been completed. A primary efficacy outcome event occurred in 83 patients (3.2% per patient-year) in the edoxaban group and in 101 patients (4.0% per patient-year) in the placebo group (hazard ratio, 0.81; 95% confidence interval [CI], 0.60 to 1.08; P = 0.15). The incidence of stroke was approximately 1% per patient-year in both groups. A safety outcome event occurred in 149 patients (5.9% per patient-year) in the edoxaban group and in 114 patients (4.5% per patient-year) in the placebo group (hazard ratio, 1.31; 95% CI, 1.02 to 1.67; P = 0.03). ECG-diagnosed atrial fibrillation developed in 462 of 2536 patients (18.2% total, 8.7% per patient-year). CONCLUSIONS: Among patients with AHREs detected by implantable devices, anticoagulation with edoxaban did not significantly reduce the incidence of a composite of cardiovascular death, stroke, or systemic embolism as compared with placebo, but it led to a higher incidence of a composite of death or major bleeding. The incidence of stroke was low in both groups. (Funded by the German Center for Cardiovascular Research and others; NOAH-AFNET 6 ClinicalTrials.gov number, NCT02618577; ISRCTN number, ISRCTN17309850.).


Asunto(s)
Anticoagulantes , Arritmias Cardíacas , Embolia , Inhibidores del Factor Xa , Anciano , Femenino , Humanos , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Embolia/tratamiento farmacológico , Embolia/etiología , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Hemorragia/inducido químicamente , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Electrodos Implantados , Método Doble Ciego , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Factores de Riesgo
6.
J Clin Med ; 12(14)2023 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-37510773

RESUMEN

Post-acute COVID-19 is characterized by the persistence of dyspnea, but the pathophysiology is unclear. We evaluated the prevalence of dyspnea during follow-up and factors at admission and follow-up associated with dyspnea persistence. After five months from discharge, 225 consecutive patients hospitalized for moderate to severe COVID-19 pneumonia were assessed clinically and by laboratory tests, echocardiography, six-minute walking test (6MWT), and pulmonary function tests. Fifty-one patients reported persistent dyspnea. C-reactive protein (p = 0.025, OR 1.01 (95% CI 1.00-1.02)) at admission, longer duration of hospitalization (p = 0.005, OR 1.05 (95% CI 1.01-1.10)) and higher body mass index (p = 0.001, OR 1.15 (95% CI 1.06-1.28)) were independent predictors of dyspnea. Absolute drop in SpO2 at 6MWT (p = 0.001, OR 1.37 (95% CI 1.13-1.69)), right ventricular (RV) global longitudinal strain (p = 0.016, OR 1.12 (95% CI 1.02-1.25)) and RV global longitudinal strain/systolic pulmonary artery pressure ratio (p = 0.034, OR 0.14 (95% CI 0.02-0.86)) were independently associated with post-acute COVID-19 dyspnea. In conclusion, dyspnea is present in many patients during follow-up after hospitalization for COVID-19 pneumonia. While higher body mass index, C-reactive protein at admission, and duration of hospitalization are predictors of persistent dyspnea, desaturation at 6MWT, and echocardiographic RV dysfunction are associated with this symptom during the follow-up period.

7.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37345804

RESUMEN

Atrial high-rate episodes (AHRE) are atrial tachyarrhythmias detected by continuous rhythm monitoring by pacemakers, defibrillators, or implantable cardiac monitors. Atrial high-rate episodes occur in 10-30% of elderly patients without atrial fibrillation. However, it remains unclear whether the presence of these arrhythmias has therapeutic consequences. The presence of AHRE increases the risk of stroke compared with patients without AHRE. Oral anticoagulation would have the potential to reduce the risk of stroke in patients with AHRE but is also associated with a rate of major bleeding of ∼2%/year. The stroke rate in patients with AHRE appears to be lower than the stroke rate in patients with atrial fibrillation. Wearables like smart-watches will increase the absolute number of patients in whom atrial arrhythmias are detected. It remains unclear whether anticoagulation is effective and, equally important, safe in patients with AHRE. Two randomized clinical trials, NOAH-AFNET6 and ARTESiA, are expected to report soon. They will provide much-needed information on the efficacy and safety of oral anticoagulation in patients with AHRE.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Factores de Riesgo , Anticoagulantes/uso terapéutico , Atrios Cardíacos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
8.
J Cardiovasc Dev Dis ; 10(4)2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37103058

RESUMEN

(1) Background: Emerging data regarding patients recovered from COVID-19 are reported in the literature, but cardiac sequelae have not yet been clarified. To quickly detect any cardiac involvement at follow-up, the aims of the research were to identify: elements at admission predisposing subclinical myocardial injury at follow up; the relationship between subclinical myocardial injury and multiparametric evaluation at follow-up; and subclinical myocardial injury longitudinal evolution. (2) Methods and Results: A total of 229 consecutive patients hospitalised for moderate to severe COVID-19 pneumonia were initially enrolled, of which 225 were available for follow-up. All patients underwent a first follow-up visit, which included a clinical evaluation, a laboratory test, echocardiography, a six-minute walking test (6MWT), and a pulmonary functional test. Of the 225 patients, 43 (19%) underwent a second follow-up visit. The median time to the first follow-up after discharge was 5 months, and the median time to the second follow-up after discharge was 12 months. Left ventricular global longitudinal strain (LVGLS) and right ventricular free wall strain (RVFWS) were reduced in 36% (n = 81) and 7.2% (n = 16) of the patients, respectively, at first the follow-up visit. LVGLS impairment showed correlations with patients of male gender (p 0.008, OR 2.32 (95% CI 1.24-4.42)), the presence of at least one cardiovascular risk factor (p < 0.001, OR 6.44 (95% CI 3.07-14.9)), and final oxygen saturation (p 0.002, OR 0.99 (95% CI 0.98-1)) for the 6MWTs. Subclinical myocardial dysfunction had not significantly improved at the 12-month follow-ups. (3) Conclusions: in patients recovered from COVID-19 pneumonia, left ventricular subclinical myocardial injury was related to cardiovascular risk factors and appeared stable during follow-up.

9.
Pacing Clin Electrophysiol ; 46(8): 960-968, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36951180

RESUMEN

BACKGROUND: Outcomes of transvenous lead extraction (TLE) are well reported in the general population, However, data on safety, efficacy of TLE in octogenarians with a long lead dwell time, using powered extraction tools are limited. The aim of this multicenter study was to evaluate the safety, effectiveness of TLE in octogenarians using the bidirectional rotational mechanical sheaths and mid-term outcome after TLE. METHODS: The study population comprised 83 patients (78.3% male; mean age 85 ± 3 years; [range 80-94 years]) with 181 target leads. All the leads (mean implant duration 112 ± 77 months [range 12-377]) were extracted exclusively using the Evolution RL sheaths (Cook Medical, Bloomington, IN, USA). RESULTS: The main indication for TLE was infection in 84.3% of cases. Complete procedural success rate, clinical success rate, per lead were 93.9% and 98.3%, respectively. Failure of lead extraction was seen in 1.7% of leads. The additional use of a snare was required in 8.4% of patients. Major complications occurred in one patient (1.2%). Thirty-day mortality after TLE was 6%. During a mean time follow-up of 22 ± 21 months, 24 patients (29%) died. No procedure-related mortality occurred. Predictors of mortality included ischemic cardiomyopathy (HR 4.35; 95% CI 1.87-10.13; p = .001), left ventricularejection fraction ≤35% (HR 7.89; 95% CI 3.20-19.48; p < .001), and TLE for systemic infection (HR 4.24; 95% CI 1.69-10.66; p = .002). CONCLUSIONS: At experienced centers bidirectional rotational mechanical sheaths combined with different mechanical tools and femoral approach allowreasonable success and safety in octogenarian with long lead dwell time. Patient's age should not influence the decision to extract or not the leads, although the 30-day and mid-term mortality are significant, especially in the present of specific comorbidities.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Anciano de 80 o más Años , Humanos , Masculino , Femenino , Desfibriladores Implantables/efectos adversos , Octogenarios , Resultado del Tratamiento , Comorbilidad , Remoción de Dispositivos/efectos adversos , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos
10.
Artículo en Inglés | MEDLINE | ID: mdl-36662384

RESUMEN

PURPOSE: The aim of the present study was to evaluate the outcome of patients underwent subcutaneous implantable cardioverter defibrillator (S-ICD) implantation with the intermuscular (IM) two-incision technique during 3-year follow-up. METHODS: the study population consisted of 105 consecutive patients (79 male; median 50 [13-77] years) underwent S-ICD implantation with the IM two-incision technique. The composite primary end point of the study consisted of device-related complications and inappropriate shocks (IAS). Secondary end points included the individual components of the primary end point, death from any cause, appropriate therapy, major adverse cardiac events, hospitalization for heart failure, and heart transplantation. RESULTS: According to the PRAETORIAN score, the risk of conversion failure was classified as low in 99 patients (94.3%), intermediate in 6 (5.7%).Ventricular fibrillation was successfully converted at ≤65 J in 97.4% of patients. During a median follow-up of 39 (16-53) months, 10 patients (9.5%) experienced device-related complications, and 9 (8.5%) patients reported IAS. Lead-associated complications were the most common (5 patients, 4.7%), including 2 cases of lead failure (1.9%). Pocket complications were reported in 2 patients (1.9%). Extra-cardiac oversensing (3.8%) represented the leading cause of IAS. No T-wave oversensing episodes were recorded. Twelve patients (11.4%) experienced appropriate shocks. Eight patients (7.6%) died during follow-up. IAS or device-related complications did not impact on mortality. CONCLUSIONS: The overall device-related complications and IAS rates over 3 years of follow-up were 9.5% and 8.5%, respectively. According to our findings, the IM two-incision technique allows for optimal positioning of the device achieving a low PRAETORIAN score with a high conversion rate. IM two-incision technique allows low incidence of pocket complications, shifting the type of complications towards lead-related complications, which represent the most common complications. The IM two-incision technique would not seem to impact the occurrence of IAS. Management of complications are safe without impact on the outcome.

11.
Clin Cardiol ; 46(2): 142-150, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36448243

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is an uncommon arrhythmia in young adults without structural heart disease, and cryoballoon pulmonary vein isolation (CB-PVI) is an important therapeutic strategy for rhythm control in patients with drug-refractory AF. The aim of this analysis was to evaluate efficacy and safety of CB-PVI in a large cohort of young patients in comparison with middle-aged adults in a real-world setting. METHODS: From 2012 to 2020, a total of 3033 patients with AF underwent CB-PVI and were followed prospectively in the framework of the 1STOP Clinical Service project, involving 34 Italian centers. Out of 3033 total 1STOP project subjects, a subgroup of 1318 patients were defined which included a YOUNG group (age ≤ 45 years; n = 368) and a MIDDLE-AGED group (age 60-65 years; n = 950). RESULTS: The acute success rate of PVI did not differ between the two cohorts (99.9 ± 1.3% vs. 99.8 ± 3.2%, p = 0.415). There was no difference in procedural characteristics, and periprocedural complication rates were similar among the two cohort (1.9% vs. 2.3%, p = 0.646). The 12-month freedom from AF recurrence was 88.9% (95% confidence interval [CI]: 84.7-92.0) in the YOUNG cohort and 85.6% (95% CI: 82.9-88.0) in the MIDDLE-AGED group. At 36-month follow-up, freedom from AF recurrence was 72.4% (65.5%-78.2%) and 71.8% (67.7%-75.6%), respectively with no significant difference among groups (p = 0.550). CONCLUSION: CB-PVI had similar efficacy and safety in YOUNG and MIDDLE-AGED patients. Younger age did not affect acute procedural results, complication rate, or AF recurrence after a single procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Cardiopatías , Venas Pulmonares , Persona de Mediana Edad , Adulto Joven , Humanos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Recurrencia , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
12.
Neurol Sci ; 44(3): 979-988, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36383264

RESUMEN

BACKGROUND: Subclinical atrial fibrillation (SCAF) may represent a cause of embolic stroke of undetermined source (ESUS) and its detection has important implications for secondary prevention with anticoagulation. Indications to implantable cardiac monitors (ICM) include SCAF detection. The aims of this study were to (1) evaluate the frequency of ICM-detected SCAF; (2) determine predictors of SCAF; and (3) identify patients who would benefit most from ICM implantation. METHODS: Between February 2017 and November 2020, all consecutive patients referred for ICM implantation after a diagnosis of ESUS and without previous history of atrial fibrillation or atrial flutter were included in this study. SCAF was diagnosed if the ICM electrogram demonstrated an episode of irregularly irregular rhythm without distinct P waves lasting > 2 min. RESULTS: We enrolled 109 patients (age 66, SD = 13 years; 36% females). During a median follow-up of 19.2 (IQR 11.0-27.5) months, SCAF episodes were detected in 36 (33%) patients. Only abnormal P wave terminal force in lead V1, left atrial end-systolic indexed volume > 34 ml/m2, and BMI > 25 kg/m2 were independently associated with an increased risk of SCAF (HR 2.44, 95% CI 1.14-5.21, p = 0.021; HR 2.39, 95% CI 1.11-5.13, p = 0.026; and HR 2.64, 95% CI 1.06-6.49, p = 0.036 respectively). The ROC curve showed that the presence of all three parameters had the best accuracy (74%) to predict SCAF detection (sensitivity 39%, specificity 91%). CONCLUSION: A multiparametric evaluation has the best accuracy to predict SCAF in ESUS patients and may help identifying those who would benefit most from ICM.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular Embólico , Accidente Cerebrovascular , Femenino , Humanos , Anciano , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Accidente Cerebrovascular Embólico/complicaciones , Factores de Riesgo , Electrocardiografía/efectos adversos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico
13.
J Cardiovasc Electrophysiol ; 34(3): 728-737, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36477909

RESUMEN

INTRODUCTION: Lead dwell time >10 years is a recognized predictor for transvenous lead extraction (TLE) failure and complications. Data on the efficacy and safety of TLE using the bidirectional rotational mechanical sheaths in patients with very old leads are lacking. In this multicenter study, we reported the outcomes of transvenous rotational mechanical lead extraction in patients with leads implanted for ≥10 years. METHODS: A total of 441 leads (median: 159 months [135-197]; range: 120-487) in 189 consecutive patients were removed with the Evolution RL sheaths (Cook Medical, Bloomingtom, IN, USA) and mechanical ancillary tools supporting the procedures. RESULTS: The main indication for TLE was infection in 74% of cases. Complete procedural success rate, clinical success rate, per lead were 94.8% and 98.2%, respectively. Failure of lead extraction was seen in 1.8% of leads. The additional use of a snare via the femoral approach was required in 9% of patients. Lead dwell time was the only predictor of incomplete led removal (odds ratio: 1.009; 95% confidence interval [CI]: 1.003-1.014; p = .002). Four major complication (2%) were encountered. During a mean time follow-up of 31 ± 27 months, 21 patients (11%) died. No procedure-related mortality occurred. Predictors of mortality included severe left ventricular systolic dysfunction (hazard ratio [HR]: 8.06; 95% CI: 2.99-21.73; p = .001), TLE for infection (HR: 8.0; 95% CI: 1.04-62.5; p = .045), diabetes (HR: 3.7; 95% CI: 1.48-9.5; p = .005), and previous systemic infection (HR: 3.1; 95% CI: 1.17-8.24; p = .022). Incomplete lead removal or failure lead extraction did not impact on survival during follow-up. CONCLUSION: Our findings demonstrated that the use of bidirectional rotational TLE mechanical sheaths combined with different mechanical tools and femoral approach allows reasonable success and safety in patients with very old leads at experienced specialized centers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Remoción de Dispositivos/métodos , Electrodos Implantados , Estudios Retrospectivos , Resultado del Tratamiento
15.
J Clin Med ; 11(15)2022 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-35956217

RESUMEN

When approaching infected lead removal in cardiac device-related infective endocarditis (CDRIE), a surgical consideration for large (>20 mm) vegetations is recommended. We report our experience with the removal of large CDRIE vegetations using the AngioVac system, as an alternative to conventional surgery. We retrospectively reviewed all infected lead extractions performed with a prior debulking using the AngioVac system, between October 2016 and April 2022 at our institution. A total of 13 patients presented a mean of 2(1) infected leads after a mean of 5.7(5.7) years from implantation (seven implantable cardioverter-defibrillators, four cardiac resynchronization therapy-defibrillators, and two pacemakers). The AngioVac system was used as a venous−venous bypass in six cases (46.2%), venous−venous ECMO-like circuit (with an oxygenator) in five (38.5%), and venous−arterial ECMO-like circuit in two cases (15.4%). Successful (>70%) aspiration of the vegetations was achieved in 12 patients (92.3%) and an intraoperative complication (cardiac perforation) only occurred in 1 case (7.7%). Subsequent lead extraction was successful in all cases, either manually (38.5%) or using mechanical tools (61.5%). The AngioVac system is a promising effective and safe option for large vegetation debulking in CDRIE. Planning the extracorporeal circuit design may represent the optimal strategy to enhance the tolerability of the procedure and minimize adverse events.

16.
Front Cardiovasc Med ; 9: 964694, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35935654

RESUMEN

Introduction: Predictors of late life-threatening arrhythmic events in Brugada syndrome (BrS) patients who received a prophylactic ICD implantation remain to be evaluated. The aim of the present long-term multicenter study was to assess the incidence and clinical-electrocardiographic predictors of late life-threatening arrhythmic events in BrS patients with a prophylactic implantable cardioverter defibrillator (ICD) and undergoing generator replacement (GR). Methods: The study population included 105 patients (75% males; mean age 45 ± 14years) who received a prophylactic ICD and had no arrhythmic event up to first GR. Results: The median period from first ICD implantation to last follow-up was 155 (128-181) months and from first ICD Implantation to the GR was 84 (61-102) months. During a median follow-up of 57 (38-102) months after GR, 10 patients (9%) received successful appropriate ICD intervention (1.6%/year). ICD interventions included shock on ventricular fibrillation (n = 8 patients), shock on ventricular tachycardia (n = 1 patient), and antitachycardia pacing on ventricular tachycardia (n = 1 patient). At survival analysis, history of atrial fibrillation (log-rank test; P = 0.02), conduction disturbances (log-rank test; P < 0.01), S wave in lead I (log-rank test; P = 0.01) and first-degree atrioventricular block (log-rank test; P = 0.04) were significantly associated with the occurrence of late appropriate ICD intervention. At Cox-regression multivariate analysis, S-wave in lead I was the only independent predictor of late appropriate ICD intervention (HR: 9.17; 95%CI: 1.15-73.07; P = 0.03). Conclusions: The present study indicates that BrS patient receiving a prophylactic ICD may experience late appropriate intervention after GR in a clinically relevant proportion of cases. S-wave in lead I at the time of first clinical evaluation was the only independent predictor of persistent risk of life-threatening arrhythmic events. These findings support the need for GR at the end of service regardless of previous appropriate intervention, mostly in BrS patients with conduction abnormalities.

17.
J Cardiovasc Med (Hagerstown) ; 23(8): 546-550, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35905001

RESUMEN

BACKGROUND: The 2020 severe acute respiratory syndrome coronavirus 2 outbreak entailed reduced availability of traditional (in-office) cardiology consultations. Remote monitoring is an alternative way of caring that may potentially mitigate the negative effects of the epidemic to the care of cardiovascular diseases. We evaluated the outcome of implantable cardioverter defibrillator (ICD) carriers followed up remotely in 2020 (epidemic period) versus 2019 (control). METHODS: We included all patients with an ICD who remained remotely monitored from the beginning to the end of each year. The combined end point included: new-onset atrial fibrillation; sustained ventricular tachycardia >170 bpm without ICD intervention; appropriate ICD intervention (either shock or antitachycardia pacing); any-cause death. Multiple events in the same patients were counted separately if occurring ≥48 h apart. RESULTS: In 2020, 52 end points occurred in 37 of 366 (10%) ICD carriers [0.14/patient (95% confidence interval [CI] = 0.11-0.19)] versus 43 end points in 32 of 325 (10%) ICD carriers in 2019 [0.13/patient (95% CI = 0.10-0.18) P  = 0.75]. There was no difference between the distribution of any individual end point in 2020 versus 2019 although a nonsignificant mortality increase was observed (from 2.8% to 4.6%, P  = 0.19). The lowest weekly event rate occurred during the national lock down in spring 2020 but a similar trend occurred also in 2019 suggesting that the effect may not be linked to social distancing measures. CONCLUSIONS: We did not observe an increase in a combined end point including arrhythmic events and mortality in ICD carriers who were remotely monitored in 2020, compared to 2019, despite the negative impact of the coronavirus disease 2019 outbreak on the healthcare system.


Asunto(s)
Cuidados Posteriores/métodos , COVID-19/epidemiología , Desfibriladores Implantables , Consulta Remota , SARS-CoV-2 , Cuidados Posteriores/normas , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/prevención & control , COVID-19/complicaciones , Control de Enfermedades Transmisibles/métodos , Control de Enfermedades Transmisibles/normas , Brotes de Enfermedades , Humanos , Consulta Remota/normas , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/prevención & control
18.
Artículo en Inglés | MEDLINE | ID: mdl-35831772

RESUMEN

BACKGROUND: Subcutaneous implantable cardioverter defibrillator (S-ICD) is a suitable alternative for transvenous ICD (TV-ICD) patients who have undergone transvenous lead extraction (TLE). Limited data are available on the outcome of S-ICD patients implanted after TLE. We assessed the safety, efficacy, and outcome of S-ICD implantation after TLE of TV-ICD. METHODS: The study population consisted of 36 consecutive patients with a median age of 52 (44-66) years who underwent S-ICD implantation after TLE of TV-ICD. RESULTS: Indications for TLE were infection (63.9%) and lead malfunction (36.1%). During a median follow-up of 31 months, 3 patients (8.3%) experienced appropriate therapy and 7 patients (19.4%) experienced complications including inappropriate therapy (n = 4; 11.1%), isolated pocket erosion (n = 2; 5.5%), and ineffective therapy (n = 1; 2.8%). No lead/hardware dysfunction was reported. Premature device explantation occurred in 4 patients (11%). Eight patients (22.2%) died during follow-up, six of them (75%) because of refractory heart failure (HF). There were no S-ICD-related deaths. Predictors of mortality included NYHA class ≥ 2 (HR 5.05; 95% CI 1.00-26.38; p = 0.04), hypertension (HR 22.72; 95% CI 1.05-26.31; p = 0.02), diabetes (HR 10.64; 95% CI 2.05-55.60; p = 0.001) and ischemic heart disease (HR 5.92; 95% CI 1.17-30.30; p = 0.01). CONCLUSION: Our study provides evidences on the use of S-ICD as an alternative after TV-ICD explantation for both infection and lead failure. Mortality of S-ICD patients who underwent TV-ICD explantation does not appear to be correlated with the presence of a prior infection, S-ICD therapy (appropriate or inappropriate), or S-ICD complications but rather to worsening of HF or other comorbidities.

19.
Pacing Clin Electrophysiol ; 45(1): 92-102, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34699079

RESUMEN

BACKGROUND: Recent studies have shown that Evolution RL bidirectional rotational mechanical sheath (Cook Medical, USA) is an effective and safe technique for transvenous lead extraction (TLE). We reported our experience with the bidirectional rotational mechanical tools using a multidisciplinary approach highlighting the value of a joint cardiac surgeon and electrophysiologist collaboration. METHODS: The study population comprised 84 patients (77% male; mean age 65 ± 18 years) undergoing TLE. After a multidisciplinary evaluation, a combined procedure was considered. RESULTS: The main indication for TLE was infection in 54 cases (64%). Overall, 152 leads were extracted with a mean implant duration of 94 ± 63 months (range 12-421). Complete procedural success rate, clinical success rate, and lead removal with clinical success rate were 91.6% (77/84), 97.6% (82/84), and 98.6% (150/152), respectively. Eighteen combined procedures were performed in 12 patients (14%), such as "hybrid approach" (n = 2) or TLE concomitant to: 1) transcatheter aspiration procedure for large vegetation (n = 8); 2) left ventricular assistance device implantation as bridge to cardiac transplantation (n = 1); 3) permanent pacing with epicardial leads (n = 6); 4) tricuspid valve replacement (n = 1). One major complication (1.2%) and 11 (13%) minor complications were encountered. No injury to the superior vena cava occurred and no procedure-related deaths were reported. During a mean time follow-up of 21 ± 18 months, 17 patients (20%) died. They were more often diabetics (p = .02), and they underwent TLE more often for infection (p = .004). CONCLUSIONS: Our results support the finding that excellent outcomes can be achieved in performing TLE of chronically implanted leads by using the Evolution RL bidirectional rotational mechanical sheath and a multidisciplinary team approach involving both electrophysiologist and cardiac surgeon as first line operators.


Asunto(s)
Cardiólogos , Remoción de Dispositivos/métodos , Electrodos Implantados , Relaciones Interprofesionales , Infecciones Relacionadas con Prótesis/terapia , Cirujanos , Anciano , Electrofisiología Cardíaca , Desfibriladores Implantables , Femenino , Humanos , Masculino , Marcapaso Artificial
20.
J Clin Med ; 10(23)2021 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-34884329

RESUMEN

From 2020, many countries have adopted several restrictions to limit the COVID-19 pandemic. The forced containment impacted on healthcare organizations and the everyday life of patients with heart disease. We prospectively analyzed data recorded from implantable defibrillators and/or cardiac resynchronization devices of Italian patients during the lockdown (LDP), post-lockdown period (PLDP) and a control period (CP) of the previous year. We analyzed device data of the period 9 March 2019-31 May 2020 of remotely monitored patients from 34 Italian centers. Patients were also categorized according to areas with high/low infection prevalence. Among 696 patients, we observed a significant drop in median activity in LDP as compared to CP that significantly increased in the PLDP, but well below CP (all p < 0.0001). The median day heart rate and heart rate variability showed a similar trend. This behavior was associated during LDP with a significant increase in the burden of atrial arrhythmias (p = 0.0150 versus CP) and of ventricular arrhythmias [6.6 vs. 1.5 per 100 patient-weeks in CP; p = 0.0026]; the latter decreased in PLDP [0.3 per 100 patient-weeks; p = 0.0035 vs. LDP]. No modifications were recorded in thoracic fluid levels. The high/low prevalence of COVID-19 infection had no significant impact. We found an increase in the arrhythmic burden in LDP coupled with a decrease in physical activity and heart rate variability, without significant modifications of transthoracic impedance, independent from COVID-19 infection prevalence. These findings suggest a negative impact of the COVID-19 pandemic, probably related to lockdown restrictions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA