1.
Eur Radiol ; 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38573340

RESUMEN

OBJECTIVES: Hysterosalpingography (HSG) is widely used for evaluating the fallopian tubes; however, controversies regarding the use of water- or oil-based iodine-based contrast media (CM) remain. The aim of this work was (1) to discuss reported pregnancy rates related to the CM type used, (2) to validate the used CM in published literature, (3) to discuss possible complications and side effects of CM in HSG, and (4) to develop guidelines on the use of oil-based CM in HSG. METHODS: A systematic literature search was conducted for original RCT studies or review/meta-analyses on using water-based and oil-based CM in HSG with fertility outcomes and complications. Nine randomized controlled trials (RCTs) and 10 reviews/meta-analyses were analyzed. Grading of the literature was performed based on the Oxford Centre for Evidence-Based Medicine (OCEBM) 2011 classification. RESULTS: An approximately 10% higher pregnancy rate is reported for oil-based CM. Side effects are rare, but oil-based CM have potentially more side effects on the maternal thyroid function and the peritoneum. CONCLUSIONS: 1. HSG with oil-based CM gives approximately 10% higher pregnancy rates. 2. External validity is limited, as in five of nine RCTs, the CM used is no longer on the market. 3. Oil-based CM have potentially more side effects on the maternal thyroid function and on the peritoneum. 4. Guideline: Maternal thyroid function should be tested before HSG with oil-based CM and monitored for 6 months after. CLINICAL RELEVANCE STATEMENT: Oil-based CM is associated with an approximately 10% higher chance of pregnancy compared to water-based CM after HSG. Although side effects are rare, higher iodine concentration and slower clearance of oil-based CM may induce maternal thyroid function disturbance and peritoneal inflammation and granuloma formation. KEY POINTS: • It is unknown which type of contrast medium, oil-based or water-based, is the optimal for HSG. • Oil-based contrast media give a 10% higher chance of pregnancy after HSG, compared to water-based contrast media. • From the safety perspective, oil-based CM can cause thyroid dysfunction and an intra-abdominal inflammatory response in the patient.

2.
Radiol Med ; 129(4): 536-548, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38512611

RESUMEN

Although contrast-enhanced ultrasound (CEUS) is a widespread and easily manageable technique, image interpretation errors can occur due to the operator's inexperience and/or lack of knowledge of the frequent pitfalls, which may cause uncertain diagnosis and misdiagnosis. Indeed, knowledge of the basic physical and technical principles of ultrasound is needed both to understand sonographic image findings and to evaluate the potential and limits of the method. Like the B-mode ultrasound, the quality of the CEUS examination is also subject not only to the adequate manual skill of the operator but also to his/her deep knowledge of the technique which improves the quality of the image helping avoid misleading artifacts. In this review, the main parameters influencing a CEUS examination will be described by taking into account the most common errors and pitfalls and their possible solutions.


Asunto(s)
Artefactos , Medios de Contraste , Humanos , Masculino , Femenino , Ultrasonografía/métodos , Errores Diagnósticos
4.
Eur Radiol ; 34(4): 2512-2523, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37823923

RESUMEN

The pharmacokinetics of contrast media (CM) will determine how long safe waiting intervals between successive CT or MRI examinations should be. The Contrast Media Safety Committee has reviewed the data on pharmacokinetics of contrast media to suggest safe waiting intervals between successive contrast-enhanced imaging studies in relation to the renal function of the patient. CLINICAL RELEVANCE STATEMENT: Consider a waiting time between elective contrast-enhanced CT and (coronary) angiography with successive iodine-based contrast media administrations in patients with normal renal function (eGFR > 60 mL/min/1.73 m2) of optimally 12 h (near complete clearance of the previously administered iodine-based contrast media) and minimally 4 h (if clinical indication requires rapid follow-up). KEY POINTS: • Pharmacokinetics of contrast media will guide safe waiting times between successive administrations. • Safe waiting times increase with increasing renal insufficiency. • Iodine-based contrast media influence MRI signal intensities and gadolinium-based contrast agents influence CT attenuation.


Asunto(s)
Yodo , Insuficiencia Renal , Humanos , Medios de Contraste/efectos adversos , Listas de Espera , Angiografía Coronaria
5.
Eur Radiol ; 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38092951

RESUMEN

OBJECTIVES: It is uncertain whether modern iodine-based or gadolinium-based contrast media (CM) administration can lead to increased symptoms in patients with myasthenia gravis. METHODS: A systematic search in Medline was conducted for studies describing the symptomatology of myasthenia gravis patients before and after receiving intravenous (IV) CM and having a matched control group of myasthenia gravis patients who did not receive IV CM. RESULTS: Three retrospective studies were selected with a total of 374 myasthenia gravis patients who received iodine-based CM and a total of 313 myasthenia gravis patients who underwent unenhanced CT and served as controls. Pooling of the data from the three retrospective studies showed that in 23 of 374 patients, increased symptoms after iodine-based CM administration were described (6.1%). Increased symptomatology also occurred in 11 of 313 patients after unenhanced CT (3.5%). When looking more deeply into the data of the three studies, conflicting results were found, as two articles did not find any relationship between CM and myasthenia gravis symptoms. The remaining study only found a significant increase in symptomatology within 1 day after CT scanning: seven patients (6.3%) in the contrast-enhanced CT group and one patient (0.6%) in the unenhanced CT group (p = 0.01). CONCLUSIONS: There is limited evidence on the relationship between CM and myasthenia gravis symptoms. In the vast majority of myasthenia gravis patients, CM are safe. Probably, in less than 5% of the patients, iodine-based CM administration may lead to increased severity of the symptoms within the first 24 h after administration. CLINICAL RELEVANCE STATEMENT: Be aware that intravenous administration of iodine-based contrast media can lead to an increase of symptoms in patients with myasthenia gravis within the first 24 h. This can probably happen in less than 5% of the patients. KEY POINTS: • It is unclear whether modern contrast media can lead to increased symptoms in myasthenia gravis patients after intravenous administration. • There seems to be a small risk of increased myasthenia gravis symptoms within 24 h after intravenous administration of iodine-based contrast media, probably in less than 5% of the administrations. • Gadolinium-based contrast media are safe for patients with myasthenia gravis.

6.
Eur Radiol ; 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38060004

RESUMEN

The Contrast Media Safety Committee of the European Society of Urogenital Radiology has, together with the Preanalytical Phase Working Group of the EFLM Science Committee, reviewed the literature and updated its recommendations to increase awareness and provide insight into these interferences. CLINICAL RELEVANCE STATEMENT: Contrast Media may interfere with clinical laboratory tests. Awareness of potential interference may prevent unwanted misdiagnosis. KEY POINTS: • Contrast Media may interfere with clinical laboratory tests; therefore awareness of potential interference may prevent unwanted misdiagnosis. • Clinical Laboratory tests should be performed prior to radiological imaging with contrast media or alternatively, blood or urine collection should be delayed, depending on kidney function.

7.
Cancers (Basel) ; 15(22)2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-38001591

RESUMEN

BACKGROUND: Ultrasonography (US) represents the gold standard imaging method for the assessment of testicular lesions (TL). The gray-scale (GSUS) and color-Doppler (CDUS) ultrasound examination allow sonographers to investigate the size, margins, echotexture, and vascular features of TLs with the aim to differentiate benign from malignant lesions. Recently, the use of contrast-enhanced US (CEUS) and sonoelastography (SE) has led to further improvements in the differential diagnosis of TL. Although GSUS and CDUS are often sufficient to suggest the benign or malignant nature of the TL, CEUS can be decisive in the differential diagnosis of unclear findings, while SE can help to strengthen the diagnosis. The contemporary combination of GSUS, CDUS, CEUS, and SE has led to a new diagnostic paradigm named multiparametric US (mp-US), which is able to provide a more detailed characterization of TLs than single techniques alone. This narrative and pictorial review aimed to describe the mp-US appearance of several TLs. METHODS: An extensive Medline search was performed to identify studies in the English language focusing on the mp-US evaluation of TLs. RESULTS: A practical mp-US "identity card" and iconographic characterization of several benign and malignant TLs is provided herein. CONCLUSIONS: The mp-US characterization of TL reported herein can be useful in daily clinical practice.

8.
Cancers (Basel) ; 15(19)2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37835403

RESUMEN

It is time for a change. CEUS is an established method that should be much more actively included in renal cyst monitoring strategies. This review compares the accuracies, strengths, and weaknesses of CEUS, CECT, and MRI in the classification of renal cysts. In order to avoid overstaging by CEUS, a further differentiation of classes IIF, III, and IV is required. A further development in the refinement of the CEUS-Bosniak classification aims to integrate CEUS more closely into the monitoring of renal cysts and to develop new and complex monitoring algorithms.

9.
Insights Imaging ; 14(1): 158, 2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37749287

RESUMEN

Penile traumatic injuries are rare with potentially severe consequences, with clinical assessment challenging due to pain and swelling. Ultrasound is the primary imaging modality for assessing the penis. It has a high spatial resolution and rapid availability and is portable. Contrast enhanced ultrasound is an advanced ultrasound technique that adds real-time dynamic vascular imaging safely, increasing diagnostic precision and confidence, allowing for better therapeutic management of traumatic penile injuries. Contrast enhanced ultrasound helps to delineate the extent of a haematoma, distinguishing this from the herniated corpus cavernosum, detecting the point of rupture of the tunica albuginea, showing vascular abnormalities, localising a dislocated penis and determining penile viability. The integrity of the urethra may be assessed with intracavitary contrast enhanced ultrasound. Additionally, contrast enhanced ultrasound allows monitoring of the response to endovascular and surgical treatment. This review aims to detail the anatomy and pathogenesis of penile trauma, to give guidance on optimising the contrast enhanced ultrasound technique and to obtain diagnostic examinations. Illustration of the spectrum of aspects of penile trauma will be complemented with a literature review.Critical relevance statement Contrast enhanced ultrasound is a safe and efficient imaging modality that allows for highly accurate diagnoses, helping achieve more successful and conservative treatments of penile trauma complications.Key points• Ultrasound is an accurate and safe imaging test for penile trauma.• CEUS adds dynamic vascular imaging in real-time increasing diagnostic confidence.• CEUS can delineate penile haematomas, locate fractures and demonstrate vessel integrity.• CEUS potentially allows for more conservative treatment of penile trauma complications.

10.
Int J Impot Res ; 2023 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-37179422

RESUMEN

Assigned female at birth with anorgasmia possess a smaller clitoral glans and clitoral components farther from the vagina lumen than women with normal orgasmic function. There are no studies evaluating this correlation in operated transgender women. We evaluated whether differences in MRI measurements of neoclitoris volume and distance between the neoclitoris and the neovagina were correlated with differences in sexual function. We recruited for a prospective survey study 40 operated male to female patients (oMtF) who had undergone genital gender affirming surgery and postoperative pelvic MRI. Individual pelvic MRIs were reviewed by two blinded investigators, the three axes of the neoclitoris were measured and the volume was calculated using the ellipsoid formula. The distance between the neoclitoris and the neovagina was also measured. Sexual functioning was assessed using the Female Sexual Function Index (FSFI) and the operated Male to Female Sexual Function Index (oMtFSFI). Mean scores differences in FSFI, oMtFSFI were examined; associations with clitoral size, location, sexual functioning and demographical variables were investigated as well. The response rate was 55%, 11 MtFs operated with pubic neoclitoris technique (PNT) and 11 with neo-urethroclitoroplasty according to Petrovic (NCP). The NCP group presented a neoclitoris mean volume of 1.04 (SD 0.39) cc vs 1.31 (SD 0.78) cc of the other group (p = 0.55). The mean distance between neoclitoris and neovagina was 4.20 (SD 0.57) cm in the PNT group and 2.55 (SD 0.45) in the NCP group (p < 0.001). Patients who had undergone NCP achieved a higher FSFI and oMtFSFI mean Total Score than those operated with the previous technique (FSFI 25.81 SD 3.02 vs 18.62 SD 9.92 p = 0.08; oMtFSFI 37.63 SD 8.28 vs 43.36 SD 13.02 p = 0.23). According to pelvic MRI measurements, this study suggests a correlation between neoclitoral location and oMtF sexual satisfaction.

11.
J Ultrasound ; 26(3): 725-731, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37147558

RESUMEN

Extrahepatic biliary tract and gallbladder neoplastic lesions are relatively rare and hence are often underrepresented in the general clinical recommendations for the routine use of ultrasound (US). Dictated by the necessity of updated summarized review of current literature to guide clinicians, this paper represents an updated position of the Italian Society of Ultrasound in Medicine and Biology (SIUMB) on the use of US and contrast-enhanced ultrasound (CEUS) in extrahepatic biliary tract and gallbladder neoplastic lesions such as extrahepatic cholangiocarcinoma, gallbladder adenocarcinoma, gallbladder adenomyomatosis, dense bile with polypoid-like appearance and gallbladder polyps.


Asunto(s)
Adenocarcinoma , Enfermedades de la Vesícula Biliar , Neoplasias de la Vesícula Biliar , Humanos , Neoplasias de la Vesícula Biliar/diagnóstico por imagen , Neoplasias de la Vesícula Biliar/patología , Adenocarcinoma/patología , Ultrasonografía
12.
Minerva Urol Nephrol ; 75(3): 289-296, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36940164

RESUMEN

INTRODUCTION: A Doppler ultrasound (US) of the scrotum is commonly used to improve the diagnostic confidence for testicular torsion in an emergency setting. However, the sensitivity of this investigation to identify torsion varies largely. This is due, in part, to a lack of guidelines on how-to perform the US and therefore training is necessary. EVIDENCE ACQUISITION: The Scrotal and Penile Imaging Working Group of the European Society of Urogenital Radiology (ESUR-SPIWG) and the Section of Urological Imaging of the European Association of Urology (ESUI) established a joint panel of experts to standardize Doppler US investigation of patients with testicular torsion. The panel reviewed the available literature, identified accumulated knowledge and limitations, and released recommendations on how-to perform Doppler US in patients with acute scrotal pain. EVIDENCE SYNTHESIS: Diagnosis of testicular torsion is based on clinical evaluation and investigation of the cord, the testis, and the paratesticular structures. A preliminary clinical evaluation, including history and palpation, is necessary. Grey scale US, color Doppler US and spectral analysis must be performed by a sonologist with at least level 2 competence. Modern equipment with adequate grey-scale and Doppler capabilities are required. CONCLUSIONS: Standardization of Doppler US in suspicious testicular torsion is presented, with the aim to obtain comparable results among different centres, prevent unnecessary operations, and improve patient management.


Asunto(s)
Enfermedades de los Genitales Masculinos , Torsión del Cordón Espermático , Masculino , Humanos , Torsión del Cordón Espermático/diagnóstico , Torsión del Cordón Espermático/cirugía , Testículo/diagnóstico por imagen , Escroto/diagnóstico por imagen , Ultrasonografía Doppler en Color/métodos
15.
Eur Urol Focus ; 9(2): 361-370, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36257887

RESUMEN

CONTEXT: Unlike palpable lumps, a large number of nonpalpable testicular lesions found incidentally at ultrasound in asymptomatic postpuberal males are either benign tumours or non-neoplastic lesions. The prevalence of malignancy, however, is appraised based on small case series. Dedicated studies report a large number of patients, and systematic review articles are lacking. OBJECTIVE: This systematic review is aimed to assess, from the analysis of the pooled data of the available literature, the incidence of benign tumours, malignant tumours, and non-neoplastic lesions, and to identify predictive characteristics for malignancy. EVIDENCE ACQUISITION: A systematic review of PubMed, Scopus, Google Scholar, Turning Research Into Practice (TRIP) database, and the Cochrane Library was conducted on January 6, 2022, according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement. Studies were retrieved reporting on adult asymptomatic men, with single, incidentally identified small testicular lesions, either fertile or infertile, with negative tumour markers and without specific risk factors for malignancy. Lesions ≤20 mm were considered small. Seventy-four studies were selected for inclusion in this analysis. Twenty-six additional publications have been retrieved by the bibliography quoted in the selected articles. EVIDENCE SYNTHESIS: Pooled data of 1348 lesions in 1348 patients were collected. Of these lesions, 408 could be retrieved individually, 44.6% were benign, 27.2% were malignant, and 20.8% were non-neoplastic. Virtually all lesions <3 mm and 86.6% of lesions <5 mm were benign. Lesions >10 mm have a 38.14% probability of being benign. Hyperechoic lesions are likely benign. Fertility status does not affect the risk of malignancy. CONCLUSIONS: Very small (<3 mm) and small (<5 mm) incidentally detected testicular lesions in asymptomatic postpuberal men with normal tumour markers could be frequently benign. More prospective studies are needed to better support this finding. Management strategies should be developed for these patients to reduce overtreatment. PATIENT SUMMARY: Small testicular lesions are incidentally founded at ultrasound. It is not easy to distinguish a benign lesion from a malignant one. Results of this study are reporting a higher incidence of benign lesions with a diameter of <5 mm. More studies are needed to better understand the biology and the management strategy for small testicular lesions.


Asunto(s)
Infertilidad , Neoplasias Testiculares , Masculino , Humanos , Adulto , Neoplasias Testiculares/diagnóstico por imagen , Neoplasias Testiculares/epidemiología , Neoplasias Testiculares/patología , Ultrasonografía , Estudios Prospectivos
16.
Clin Genitourin Cancer ; 20(6): e506-e511, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35965197

RESUMEN

INTRODUCTION: Percutaneous microwave ablation (MWA) of renal masses (RM) is still considered experimental as opposed to established procedures such as cryoablation (CA). We aimed to compare perioperative, functional and oncological outcomes of patients with RM treated with CA and MWA. MATERIALS AND METHODS: Data from 116 (69.9%) and 50 (30.1%) patients treated with CA and MWA for RM were analyzed. Patients' demographics and perioperative data were collected including nephrometry scores, complications, pre- and postprocedural renal function. Tumor persistence and recurrence were recorded. Descriptive statistics compared functional outcomes between groups. Cox regression analyses tested risk factors associated with recurrence. RESULTS: Groups were similar in terms of RM diameter, nephrometry scores and histology distribution. Median follow-up was 26 (13-46) and 24 (14-36) months for CA and MWA, respectively. The rate of overall (36.2% for CA vs. 24% for MWA, P= .1) and major (Clavien ≥ 3a) complications (1.7% vs. 5.4%, P = .1) were similar among groups. The median decline of renal function after 6 months follow-up did not differ between CA and MWA (P = .8). Tumor persistence [4.3% vs. 12%] and recurrence [9.5% and 7.1%] rates were similar for CA and MWA. Three years recurrence free and overall survival were 91% versus 95% (log-rank P = .77) and 80 versus 88% (log-rank P = .23) in the CA and MWA groups, respectively. At Cox analysis no predictors were found associated with recurrence. CONCLUSION: Despite being considered still experimental, MWA showed comparable outcomes relative to CA in terms of safety, preservation of renal function and oncological efficacy.


Asunto(s)
Ablación por Catéter , Criocirugía , Humanos , Criocirugía/efectos adversos , Estudios Transversales , Microondas/uso terapéutico , Oncología Médica
17.
Medicina (Kaunas) ; 58(8)2022 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-36013508

RESUMEN

Background and Objectives: To assess efficacy and safety of Percutaneous Cryoablation (PCA) of small renal masses (SRMs) using Trifecta outcomes in a large cohort of patients who were not eligible for surgery. Materials and methods: All PCAs performed in four different centers between September 2009 and September 2019 were retrospectively evaluated. Patients were divided in two different groups depending on masses dimensional criteria: Group-A: diameter ≤ 25 mm and Group-B: diameter > 25 mm. Complications rates were reported and classified according to the Clavien−Dindo system. The estimate glomerular filtration rate (eGFR) was calculated before PCA and during follow-up schedule. Every patient received a Contrast Enhanced Ultrasound (CEUS) evaluation on the first postoperative day. Radiological follow-up was taken at 3, 6, and 12 months for the first year, then yearly. Radiological recurrence was defined as a contrast enhancement persistence and was reported in the study. Finally, Trifecta outcome, which included complications, RFS, and preservation of eGFR class, was calculated for every procedure at a median follow-up of 32 months. Results: The median age of the patients was 74 years. Group-A included 200 procedures while Group-B included 140. Seventy-eight patients were eligible for Trifecta evaluation. Trifecta was achieved in 69.6% of procedures in Group-A, 40.6% in Group-B (p = 0.02). We observed an increased rate of complication in Group-B (13.0% vs. 28.6; p < 0.001). However, 97.5% were

Asunto(s)
Criocirugía , Neoplasias Renales , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Tasa de Filtración Glomerular , Humanos , Neoplasias Renales/cirugía , Nefrectomía/métodos , Estudios Retrospectivos , Resultado del Tratamiento
18.
Medicina (Kaunas) ; 58(5)2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35630091

RESUMEN

The role of imaging in healthcare has become more and more significant in the last decades [...].


Asunto(s)
Infecciones Urinarias , Sistema Urinario , Predicción , Humanos , Riñón/diagnóstico por imagen , Sistema Urinario/diagnóstico por imagen
19.
Diagnostics (Basel) ; 12(5)2022 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-35626364

RESUMEN

BACKGROUND: To evaluate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in characterizing between malignant and benign renal lesions confirmed by histological examination. METHODS: Overall, 110 patients, for a total of 118 renal masses previously identified at CT and MRI underwent CEUS. An expert radiologist evaluated morphological, qualitative and quantitative parameters. Acquired data were analyzed to assess the value of each parameter to differentiate between malignant and benign lesions. RESULTS: Histological results of 118 renal masses showed 88 (75%) malignant lesions and 30 (25%) benign lesions. Among morphological features, inhomogeneous echogenicity was the best predictor of malignancy depicting a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 76%, 76%, 88% and 57%, respectively. Among qualitative parameters, the most reliable parameter was the presence of pseudo-capsule. Here, sensitivity, specificity, positive PPV and NPV were 85%, 86%, 94% and 71%, respectively. Among quantitative parameters, the most reliable parameters were peak intensity (PI) and the area under the (AUC) with sensitivity, specificity, PPV and NPV values of 94%, 92%, 96% and 87% and 99%, 92%, 97% and 97%, respectively. Finally, the most reliable parameters were combined to distinguish between benign and malignant lesions. The best combination obtained was restricted to CEUS parameters (PI and AUC). Here, sensitivity, specificity, PPV, NPV and accuracy rate were 93%, 100%, 100%, 83% and 93%, respectively. CONCLUSIONS: CEUS increases the US accuracy to discriminate between benign and malignant renal lesions.

20.
Eur J Radiol ; 150: 110267, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35325773

RESUMEN

PURPOSE: To investigate the inter-reader agreement of the Prostate imaging quality (PI-QUAL) for multiparametric magnetic resonance imaging (mpMRI). METHODS: We included 66 men who underwent 1.5 T mpMRI in June 2020-July 2020 in center 1, with no exclusion criteria. mpMRI included multiplanar T2-weighted imaging (T2WI), Diffusion-weighted imaging (DWI), and dynamic contrast-enhanced imaging (DCE). Two readers from center 2 (experience <1000 to >1500 examinations), blinded to clinical history but not to acquisition parameters, independently assessed PI-QUAL qualitative/anatomical items of each mpMRI sequence, final PI-QUAL score (1-5), and the Prostate imaging reporting and data system version 2.1 (PI-RADSv2.1) category of the index lesion. Cohen's kappa statistics (k) or prevalence-adjusted-bias-adjusted kappa (PABAK) were used to calculate the inter-reader agreement in assessing the PI-QUAL (1-to-5 scale and 1-2 versus 3 versus 4-5), the diagnostic quality of each mpMRI sequence, qualitative/anatomical items, and PI-RADSv2.1 category. RESULTS: The inter-reader agreement for PI-QUAL category was moderate upon 1-5 scale (k = 0.55; 95%CI 0.39-0.71) or 1-3 scale (k = 0.51; 95%CI 0.29-0.72), with 90.9% examinations categorized PI-QUAL ≥ 3 by readers. The agreement in assessing a sequence as diagnostic was higher for T2WI (k = 0.76) than DCE (PABAK = 0.61) and DWI (k = 0.46), ranging moderate-to-substantial for most of the items. Readers provided comparable PI-RADSv2.1 categorization (k = 0.88 [excellent agreement]; 95%CI 0.81-0.96), with most PI-RADSv2.1 ≥ 3 assignments found in PI-QUAL ≥ 3 examinations (43/46 by reader 1, and 47/47 by reader 2). CONCLUSIONS: The reproducibility of PI-QUAL was moderate. Higher PI-QUAL scores were associated with excellent inter-reader agreement for PI-RADSv2.1 categorization.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Humanos , Imagen por Resonancia Magnética , Masculino , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA