1.
Artículo en Inglés | MEDLINE | ID: mdl-38978283

RESUMEN

INTRODUCTION: The QDOT MICROTM Ablation Catheter is a next-generation ablation catheter that allows for high-power ablation up to 90 watts. METHODS: We aimed to assess AE associated with the QDOT MICROTM catheter using the MAUDE database. A MAUDE database search was conducted on May 25, 2024, to capture all AEs (since FDA approval) associated with this ablation catheter. RESULTS: A total of 302 AEs from November 23, 2022, to April 30, 2024, were reported including 148 (49%) catheter-related issues and 154 (51%) clinical complications. Among the catheter-related issues, physical catheter damage (74.3%, n = 110) was most common, followed by communication or display issue (10.8%, n = 16), irrigation issue (9.5%, n = 14), signal issue or artifact (3.4%, n = 5), and inaccurate temperature measurement (2.0%, n = 3). Regarding clinical complications, the most common AE was pericardial effusion (43.5%, n = 67), followed by char formation (11.7%, n = 18), catheter thrombosis (7.1%, n = 11), stroke (7.1%, n = 11), pericarditis (7.1%, n = 11), esophageal complications (6.5%, n = 10), phrenic nerve palsy (3.9%, n = 6), cardiac arrest (3.9%, n = 6), significant AV block (3.9%, n = 6), pulmonary vein stenosis (3.2%, n = 5), coronary artery spasm (1.3%, n = 2), and pulmonary embolism (0.6%, n = 1). There were 11 deaths (five related to esophageal complications, five related to cardiac arrest, and one related to pericardial effusion with cardiac tamponade). CONCLUSION: As high-power ablation strategy with novel ablation catheters is becoming more widely utilized, operators must be aware of potential catheter-related issues and clinical complications that may arise. More data are needed to further evaluate risks of these complications to improve the catheter's safety and efficacy.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38887842

RESUMEN

INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38443707

RESUMEN

INTRODUCTION: Cardiac implantable electronic device (CIED) functions are susceptible to electromagnetic interference (EMI) from electromagnetic fields (EMF). Data on EMI risks from new-generation electronic appliances (EA) are limited. OBJECTIVE: We performed a systematic literature review on the mechanisms of EMI, current evidence, and recently published trials evaluating the effect of EMF on CIEDs from electric vehicles (EV), smartphone, and smartwatch technology and summarize its safety data. METHODS: Electronic databases, including PubMed and EMBASE, were searched for in vivo studies evaluating EMF strength and incidence between CIEDs and commercial EVs, new-generation smartphones, and new-generation smartwatches. RESULTS: A total of ten studies (three on EVs, five on smartphones, one on smartphones, one on smartphones and smartwatches) were included in our systematic review. There was no report of EMI incidence associated with EVs or smartwatches. Magnet-containing smartphones (iPhone 12) can cause EMI when placed directly over CIEDs - thereby triggering the magnet mode; otherwise, no report of EMI was observed with other positions or smartphone models. CONCLUSION: Current evidence suggests CIED recipients are safe from general interaction with EVs/HEVs, smartphones, and smartwatches. Strictly, results may only be applied to commercial brands or models tested in the published studies. There is limited data on EMI risk from EVs wireless charging and smartphones with MagSafe technology.

7.
Circ Arrhythm Electrophysiol ; 17(4): e012717, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38390748

RESUMEN

BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5-25 g), high (26-50 g), and very high (51-80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA-and their integration in the PF index equation-on lesion size (study characterization). Then, 3 different PF index thresholds-300, 450, and 600-were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r2=0.66; P<0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


Asunto(s)
Ablación por Catéter , Porcinos , Animales , Ablación por Catéter/efectos adversos , Ventrículos Cardíacos/cirugía , Catéteres , Diseño de Equipo
10.
Circ Arrhythm Electrophysiol ; 16(12): 663-671, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37994554

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) has emerged as an alternative to radiofrequency ablation. However, data on focal point-by-point PFA are scarce. The aim of this study was to compare lesion durability and collateral damage between focally delivered unipolar/biphasic PFA versus radiofrequency in swine. METHODS: Eighteen swine were randomized to low-dose PFA, high-dose PFA, and radiofrequency using a multimodality generator. Radiofrequency delivered by market-available generator served as control group. A contact force-sensing catheter was used to focally deliver PFA/radiofrequency at the pulmonary veins and other predefined sites in the atria. Animals were remapped postprocedurally and 28 days postablation to test lesion durability followed by gross necroscopy and histology. RESULTS: All targeted sites were successfully ablated (contact force value, 13.9±4.1 g). Follow-up remapping showed persistent pulmonary vein isolation in all animals (100%) with lesion durability at nonpulmonary vein sites proven in most (98%). Regardless of the energy source used, the lesion size was similar across the study groups. Transmurality was achieved in 95% of targeted sites and 100% at pulmonary veins. On histology, PFA animals showed more mature scar formation than their radiofrequency counterpart without myocardial necrosis or inflammation. Finally, no sign of collateral damage was observed in any of the groups. CONCLUSIONS: In a randomized preclinical study, focally delivered unipolar/biphasic PFA guided by contact force values was associated with durable lesions on chronic remapping and with mature scar formation on histology without signs of collateral injury on necroscopy. Further studies are needed to investigate the long-term feasibility of this new approach to atrial fibrillation treatment.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Ablación por Radiofrecuencia , Animales , Catéteres , Cicatriz , Porcinos , Resultado del Tratamiento
11.
Artículo en Inglés | MEDLINE | ID: mdl-37885380

RESUMEN

New ablation catheters have continuously developed to improve the safety and efficacy of ablation procedures. The TactiFlex Ablation Catheter Sensor Enabled (Abbott, Minneapolis, MN) is a novel open-irrigation radiofrequency ablation catheter that has contact force-sensing technology and flexible tip, allowing real-time contact force assessment with directionality. This case report reported a loss of contact force vector and directionality with the TactiFlex SE ablation catheter during de novo atrial fibrillation (AF) ablation.

12.
Am J Cardiol ; 208: 153-155, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37839459

RESUMEN

Evidence regarding racial disparities in leadless pacemaker (LP) utilization and outcomes is limited. We aimed to explore ethnicity-based disparities in LP utilization and clinical outcomes of patients who underwent LP implantation. All consecutive patients who underwent LP between January 2019 and January 2023 at our institution were included. Charts were reviewed for baseline characteristics and clinical outcomes. The primary outcomes were procedure-related complications, cardiac rehospitalization, worsening heart failure (HF) or HF hospitalization, and all-cause mortality. All statistical analyses were performed using SPSS Statistics 22 (IBM Corp., Armonk, NY). The p <0.05 was considered statistically significant. A total of 196 adult patients underwent LP implantation during the study period (48% Caucasians, 36.2% Hispanic, 8.2% Asians, and 7.7% African-American). The groups were balanced with respect to baseline demographics, clinical characteristics, and procedure-related complications. During the median follow-up of 104 days (interquartile range 24 to 382), no statistically significant differences were observed in worsening HF or HF hospitalization or all-cause mortality among the ethnic groups. After multivariable logistic regression, Asian individuals had higher odds of cardiac readmissions (odds ratio 4.1, 95% confidence interval 1.4 to 12.3, p = 0.01). Patients from racial and ethnic minorities face significant inequities in arrhythmia care, including patients who have undergone LP implantation. Awareness and a system-based approach (understanding cultural preferences, effective application of evidence-based guidelines, and population-based policies) are crucial to lessen disparities in health care among minorities.


Asunto(s)
Etnicidad , Disparidades en Atención de Salud , Marcapaso Artificial , Grupos Raciales , Adulto , Humanos , Estados Unidos
13.
J Cardiovasc Electrophysiol ; 34(11): 2382-2385, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37679961

RESUMEN

BACKGROUND: Dual occlusive closure mechanism (disc and lobe type), Amulet device (Abbott; a second-generation device that has replaced Amplatzer Cardiac Plug) was approved by the Food and Drug Administration (FDA) in August 2021 for percutaneous left atrial appendage occlusion (LAAO). However, real-world safety data on the delivery system (Amplatzer Cardiac Plug and Amplatzer Amulet device) are lacking. OBJECTIVE: We sought to assess the type of adverse events associated with the Amplatzer LAAO delivery system using the FDA Manufacturer and User Facility Device Experience (MAUDE) database. METHODS: A MAUDE database search was conducted on March 31, 2023, for reports received between February 2013 and March 2023 to capture all adverse events. RESULTS: A total of 59 adverse events were reported, of which 58 were sheath-related events, and one was a wire-related event. The most commonly encountered issue was air embolism (19%, 11 events), followed by sheath thrombosis (13.8%, eight events, two of which were also associated with device thrombosis), kinked sheath (10.3%, six events), and sheath deformation (8.6%, five events). Patient-related adverse events included pericardial effusion requiring pericardiocentesis (22.4%, 13 events), vascular complications (20.7%, 12 events), and device dislodgement (5.2%, three events). CONCLUSION: LAAO-related adverse events are increasingly being reported using the Amplatzer LAAO delivery sheath. It is anticipated that improvements in device technology, the advent of steerable sheaths, and operator experience will minimize these complications.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Trombosis , Estados Unidos , Humanos , Apéndice Atrial/diagnóstico por imagen , United States Food and Drug Administration , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco/efectos adversos , Trombosis/etiología , Resultado del Tratamiento , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Dispositivo Oclusor Septal/efectos adversos
14.
J Cardiovasc Electrophysiol ; 34(8): 1761-1763, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37354447

RESUMEN

BACKGROUND: Swallowing-associated arrhythmias are rare and most commonly present as atrial tachycardias. METHODS: We present a case of a 45-year-old female who experienced frequent episodes of palpitations and dyspnea occurring immediately after swallowing solid food. She was noted to have atrial tachycardia with deglutition that was recorded on the 12-lead electrocardiogram. She underwent fluoroscopic esophagram that demonstrated atrial tachycardia as the barium passed through the distal esophagus and gastroesophageal junction. CONCLUSION: Swallowing induced arrhythmias occur rarely and can be confirmed by EKG obtained during deglutition. Gastroesophageal evaluation is required to rule out primary esophageal disorders. Treatment of such arrhythmias is required if symptoms are intractable and can include pharmacotherapy and radiofrequency ablation.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Femenino , Humanos , Persona de Mediana Edad , Deglución , Taquicardia Supraventricular/cirugía , Arritmias Cardíacas/cirugía , Electrocardiografía , Esófago/cirugía
15.
J Cardiovasc Electrophysiol ; 34(6): 1469-1471, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37209414

RESUMEN

BACKGROUND: Leadless pacemaker (LP) offers an innovative approach for treating bradyarrhythmia, thus avoiding pacemaker pocket and lead-related complications. The Food and Drug Administration (FDA) has recently approved the Aveir™ leadless pacing system (screw-in type LP). METHODS: We queried the FDA MAUDE database to study the safety profile and assess the types of complications with this relatively novel device technology. A MAUDE database search was conducted on January 20, 2023, for reports received post-FDA approval to capture all adverse events. RESULTS: A total of 98 medical device report were reported for Aveir™ LP. After excluding duplicate, programmer-related, or introducer-sheath-related entries (n = 34), 64 entries were included. The most commonly encountered problem was high threshold/noncapture (28.1%, 18 events), followed by stretched helix (17.2%, 11 events) and device dislodgement (15.6%, ten events-5 intraprocedural, while 5 in the postoperative Day 1). Other reported events included high impedance (14.1%, nine events), sensing issues (12.5%, eight events), bent/broken helix (7.8%, five events), premature separation (4.7%, three events), interrogation problem (3.1%, two events), low impedance (3.1%, two events), premature battery depletion (1.6%, one event) and inadvertent MRI mode switch (1.6%, one event) and miscellaneous (15.6%, n = 10). There were eight serious patient injury events-pericardial effusion requiring pericardiocentesis (7.8%, five events) due to cardiac perforation that resulted in two deaths (3.1%) followed by sustained ventricular arrhythmias (4.6%, n = 3). CONCLUSION: In our study assessing the real-world safety profile of the Aveir™ LP, serious adverse events have been reported-life-threatening ventricular arrhythmias, pericardial effusion, device explantation/reimplantation, and death.


Asunto(s)
Marcapaso Artificial , Derrame Pericárdico , Realidad Virtual , Estados Unidos , Humanos , United States Food and Drug Administration , Derrame Pericárdico/etiología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Marcapaso Artificial/efectos adversos
17.
Tissue Cell ; 82: 102053, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36907044

RESUMEN

The present study evaluated healing potential of bone marrow-derived mesenchymal stem cells (BM-MSCs) and BM-MSCs-conditioned medium (BM-MSCs-CM) for acute and subacute injuries in the rabbit peripheral nerve injury model. The regenerative capacity of MSCs was evaluated in 40 rabbits divided into eight groups, four groups each for acute and subacute injury models. BM-MSCs and BM-MSCS-CM were prepared by isolating allogenic bone marrow from the iliac crest. After inducing sciatic nerve crush injury, different treatments consisting of PBS, Laminin, BM-MSCs + laminin, and BM-MSCS-CM + laminin were used on the day of injury in the acute injury model and after ten days of crush injury in the subacute groups. The parameters studied included: pain, total neurological score, gastrocnemius muscle weight and volume ratio, histopathology of the sciatic nerve and gastrocnemius muscle, and scanning electron microscopy (SEM). Findings indicate that BM-MSCs and BM-MSCS-CM have augmented the regenerative capacity in acute and subacute injury groups with a slightly better improvement in the subacute groups than the animals in acute injury groups. Histopathology data revealed different levels of regenerative process undergoing in the nerve. Neurological observations, gastrocnemius muscle evaluation, muscle histopathology, and the SEM results depicted better healing in animals treated with BM-MSCs and BM-MSCS-CM. With this data, it could be concluded that BM-MSCs support the healing of injured peripheral nerves, and the BM-MSCS-CM does accelerate the healing of acute and subacute peripheral nerve injuries in rabbits. However, stem cell therapy may be indicated during the subacute phase for better results.


Asunto(s)
Células Madre Mesenquimatosas , Traumatismos de los Nervios Periféricos , Animales , Conejos , Medios de Cultivo Condicionados/farmacología , Traumatismos de los Nervios Periféricos/terapia , Laminina , Médula Ósea
18.
J Interv Card Electrophysiol ; 66(3): 561-566, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35469052

RESUMEN

BACKGROUND: There has been increasing interest in physiologic pacing techniques that directly activate the specialized conduction system. We aimed to assess outcomes of conduction system pacing (CSP) in patients with prosthetic heart valves. METHODS: This systematic review was performed according to PRISMA guidelines. Freeman-Tukey double arcsine transformation with the random-effect model was used to summarize the data. Outcomes studied were 1) implant success (defined as ability to recruit the His-Purkinje system or the distal Purkinje system); (2) lead parameters at implant and follow-up; and (3) procedure-related complications. RESULTS: This systematic review of 7 studies included 267 unique patients in whom CSP was attempted with either HBP or LBBAP for pacing indications after a prosthetic valve. HBP was attempted in 38% (n = 108), while LBBAP in 62% (n = 175) patients. The overall success rate of CSP was 87%, while in patients post-TAVR, the overall success rate was 83.2%. In the subgroup analysis, LBBAP had a significant higher overall success rate compared to HBP (94.3% vs. 76.5%, p interaction = 0.02) and post-TAVR patients (94.3 vs. 66.9%, p interaction < 0.01), respectively. The LBBAP thresholds were significantly lower compared to HBP both at implant (0.67 ± 0.4 @ 0.44 ms vs. 1.35 ± 1 @ 0.85 ms, p interaction < 0.01) and at a mean follow-up of 12.4 ± 8 months (0.73 ± 0.1 @ 0.44 ms vs. 1.39 ± 1 @ 0.85 ms, p interaction < 0.01), respectively. CONCLUSION: CSP is safe and feasible in patients with a prosthetic valve, with a significantly higher success rate and superior lead parameters with LBBAP than HBP, especially in patients post-TAVR.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Humanos , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco , Válvulas Cardíacas , Resultado del Tratamiento
19.
J Cardiovasc Electrophysiol ; 34(1): 219-224, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36335616

RESUMEN

BACKGROUND: Monomorphic ventricular tachycardia (VT) is rare in patients with hypertrophic cardiomyopathy (HCM), management of which is challenging. Limited data exists on the utility of catheter ablation for the treatment of VT in this population. OBJECTIVES: We aimed to assess clinical outcomes of catheter ablation for VT in HCM patients. METHODS: A systematic search, without language restriction, using PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov was performed. The meta-analysis was performed using a meta-package for R version 4.0/RStudio version 1.2 and Freeman Tukey double arcsine method to establish the variance of raw proportions. Outcomes measured included (1) acute procedure success (defined as noninducible for clinical VT), (2) freedom from VT at follow-up, (3) mortality. RESULTS: This systematic review of six studies (three from the United States and three from Japan) incorporated a total of 68 drug-refractory HCM patients who underwent VT radiofrequency catheter ablation (mean age 57.6 ± 13.3 years, mean LVEF 45.8 ± 15.4%, 85% men, maximum septal wall thickness 17.4 ± 4.6 mm, and 32.3% with an apical aneurysm). Acute procedural success was achieved in 84.5% patients (95% confidence interval [CI]: 70.6%-95.2%) with 27.9% patients had recurrent VT requiring multiple ablations (median 1, IQR 1-3). During the follow-up period (18.3 ± 11.7 months), the pooled incidence of freedom from recurrent VT after index procedure was 70.2% (95% CI: 51.9%-86.2%), while after the last ablation was 82.8% (95% CI: 57%-99.2%). There were two deaths during follow-up, one from heart failure and one from SCD 0.8% (95% CI: 0%-5.8%). CONCLUSION: The results of our pooled analysis demonstrated that catheter ablation for VT in HCM patients was associated with high acute procedural success, and reduced VT recurrence-findings comparable to previously published reports in other disease substrates.


Asunto(s)
Cardiomiopatía Hipertrófica , Ablación por Catéter , Insuficiencia Cardíaca , Taquicardia Ventricular , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Femenino , Recurrencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ablación por Catéter/métodos , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento