Clin Biochem ; 125: 110731, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38360198

RESUMEN

BACKGROUND: An analytical benchmark for high-sensitivity cardiac troponin (hs-cTn) assays is to achieve a coefficient of variation (CV) of ≤ 10.0 % at the 99th percentile upper reference limit (URL) used for the diagnosis of myocardial infarction. Few prospective multicenter studies have evaluated assay imprecision and none have determined precision at the female URL which is lower than the male URL for all cardiac troponin assays. METHODS: Human serum and plasma matrix samples were constructed to yield hs-cTn concentrations near the female URLs for the Abbott, Beckman, Roche, and Siemens hs-cTn assays. These materials were sent (on dry ice) to 35 Canadian hospital laboratories (n = 64 instruments evaluated) participating in a larger clinical trial, with instructions for storage, handling, and monthly testing over one year. The mean concentration, standard deviation, and CV for each instrument type and an overall pooled CV for each manufacturer were calculated. RESULTS: The CVs for all individual instruments and overall were ≤ 10.0 % for two manufacturers (Abbott CVpooled = 6.3 % and Beckman CVpooled = 7.0 %). One of four Siemens Atellica instruments yielded a CV > 10.0 % (CVpooled = 7.7 %), whereas 15 of 41 Roche instruments yielded CVs > 10.0 % at the female URL of 9 ng/L used worldwide (6 cobas e411, 1 cobas e601, 4 cobas e602, and 4 cobas e801) (CVpooled = 11.7 %). Four Roche instruments also yielded CVs > 10.0 % near the female URL of 14 ng/L used in the United States (CVpooled = 8.5 %). CONCLUSIONS: The number of instruments achieving a CV ≤ 10.0 % at the female 99th-percentile URL varies by manufacturer and by instrument. Monitoring assay precision at the female URL is necessary for some assays to ensure optimal use of this threshold in clinical practice.


Asunto(s)
Infarto del Miocardio , Humanos , Masculino , Femenino , Estudios Prospectivos , Canadá , Infarto del Miocardio/diagnóstico , Bioensayo , Troponina , Troponina T , Biomarcadores , Valores de Referencia
3.
Pediatr Nephrol ; 39(4): 1169-1176, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37840039

RESUMEN

BACKGROUND: When applying Pierce U25 formula for estimating glomerular filtration rate (eGFR), we observed a higher proportion of eGFR < 90 mL/min/1.73 m2 (chronic kidney disease (CKD) stage 2). We compared agreement and accuracy of the Pierce U25 (ages 2-25), Pottel (ages 2-100), and CKD-EPI (ages 18-100) formulae to GFR measurements. METHODS: Post hoc analysis of the three eGFRs compared to 367 99m technetium-diethylene-triamine penta-acetic acid (99Tc DTPA) GFR measurements (240 patients) using 3 sampling points and Brockner/Mørtensen correction (body surface area calculation based on ideal weight) on simultaneous serum creatinine and cystatin C measurements. RESULTS: Overall, the U25 formula performed well with a Spearman r of 0.8102 (95% confidence interval 0.7706 to 0.8435, p < 0.0001) while diagnostic accuracy was low in patients with normal mGFR. The U25 formula reclassified 29.5% of patients with normal mGFR as CKD stage 2; whereas the average of the modified Schwartz formula based on serum creatinine and the Filler formula based on cystatin C, only over-diagnosed CKD stage 2 in 8.5%, 24.5% within 10% and 62.7% within 30%. We therefore combined both. The average Schwartz/Filler eGFR had 36.5% of results within 10%, 84.7% within 30%, and normal mGFR accuracy was 26.8%, 63.9% for 10% and 30%, respectively, outperforming the CKD-EPI and Pottel formulae. CONCLUSIONS: The Pierce U25 formula results correlated well with mGFR < 75 mL/min/1.73 m2. Over the entire GFR range, accuracy was better for patients with a higher mGFR, when averaging the combined Schwartz/Filler formulae. More work is needed to prospectively confirm our findings in other centers.


Asunto(s)
Cistatina C , Insuficiencia Renal Crónica , Humanos , Tasa de Filtración Glomerular , Estudios Transversales , Creatinina , Insuficiencia Renal Crónica/diagnóstico
4.
BMJ Open Qual ; 12(4)2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37931984

RESUMEN

A common practice exists in hospitals where extra tubes of blood are collected for possible add-on testing, this practice contributes to wastage of consumables. Baseline estimates from a 5-month local lab information system audit revealed that ~65 extra tubes per day were being collected, with an additional 2-week manual audit of all extra tubes received in the laboratory confirming the practice. The audits showed that the majority of the tubes (~99%) were being drawn from the adult emergency department (ED). Furthermore, only 5% of the extra tubes were being used for add-on testing, whereas the remaining tubes had no testing performed on them and were discarded at the end of the day. This translates to over 23 000 extra tubes being wasted annually.After initial discussion with ED leadership, the practice was identified as primarily nurse driven. An educational intervention was created and entitled 'Every Tube Counts', with the aim to reduce extra tube collections in the adult ED by 50% within the first month of intervention. First, a memo with initial findings and a request to stop the practice of extra tube collection was sent out to all ED staff. After 2 weeks of additional data collection, it was noticed that extra tubes were still being collected. A second intervention, which consisted of another communication and utilisation of nurse educators to disseminate the information to nursing staff, saw a remarkable ~80% reduction in collection of extra tubes in the following few months after the second intervention. The practice was followed for an additional 15 months, which saw a slight increase of extra tube collections over time with a levelling off towards the latter period of the study. However, the target goal was maintained over the entire study period.


Asunto(s)
Servicio de Urgencia en Hospital , Hospitales , Adulto , Humanos , Comunicación , Recolección de Datos
5.
Front Med (Lausanne) ; 10: 1272900, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37937142

RESUMEN

Background: Urinary stone disease (USD) historically has affected older men, but studies suggest recent increases in women, leading to a near identical sex incidence ratio. USD incidence has doubled every 10 years, with disproportionate increases amongst children, adolescent, and young adult (AYA) women. USD stone composition in women is frequently apatite (calcium phosphate), which forms in a higher urine pH, low urinary citrate, and an abundance of urinary uric acid, while men produce more calcium oxalate stones. The reasons for this epidemiological trend are unknown. Methods: This perspective presents the extent of USD with data from a Canadian Province and a North American institution, explanations for these findings and offers potential solutions to decrease this trend. We describe the economic impact of USD. Findings: There was a significant increase of 46% in overall surgical interventions for USD in Ontario. The incidence rose from 47.0/100,000 in 2002 to 68.7/100,000 population in 2016. In a single United States institution, the overall USD annual unique patient count rose from 10,612 to 17,706 from 2015 to 2019, and the proportion of women with USD was much higher than expected. In the 10-17-year-old patients, 50.1% were girls; with 57.5% in the 18-34 age group and 53.6% in the 35-44 age group. The roles of obesity, diet, hormones, environmental factors, infections, and antibiotics, as well as the economic impact, are discussed. Interpretation: We confirm the significant increase in USD among women. We offer potential explanations for this sex disparity, including microbiological and pathophysiological aspects. We also outline innovative solutions - that may require steps beyond typical preventive and treatment recommendations.

6.
Ann Clin Biochem ; : 45632231213746, 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-37903217

RESUMEN

BACKGROUND: Delayed time from collection to centrifugation may cause erroneously high lactate levels in vitro (from continued blood cell metabolism under anaerobic conditions in the collection tube) if not collected in appropriate collection devices, consequently increasing the risk for inappropriate patient care or harm. We undertook a study to determine the turnaround time for lactate testing in a tertiary care setting and also performed short- and long-term lactate stability studies in blood collected in sodium fluoride/potassium oxalate (NaF/KOx) collection tubes. METHODS: The hospital lab information system was mined for 6 months to determine patient samples that may have exceeded the time from collection-to-receival in lab of 15-min. Lactate stability was evaluated in unspun NaF/KOx collection tubes at 15 min intervals for to 2 h; and separately at 2, 6, 12, 24, and 48-h post-collection. RESULTS: A total of 8,929 plasma samples were collected in 6 months, and 1/3 were not received in the lab within 15 min from collection. In NaF/KOx additive, lactate levels had minor increases over 2 h, and incremental increases at an average rate of 0.0035 mmol/L/h over 48 h with maximum increase of 9.8% at 48 h. However, the average change across all time points were within local allowable performance goals (at ≤4 mmol/L ± 0.5 mmol/L; at >4 mmol/L ± 12%). CONCLUSION: A small proportion of lactate specimens may experience delay in processing. Although lactate levels may incrementally increase over 48-h at room temperature in unspun NaF/KOx collection tubes, the changes may not be clinically impactful.

7.
Clin Biochem ; 118: 110587, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37236296

RESUMEN

OBJECTIVE: The antibiotic metronidazole has been suggested to absorb light at a wavelength range commonly used in spectrophotometric assays. We sought to determine if any of the spectrophotometric assays used in our core laboratory would be susceptible to clinically significant interference from metronidazole in blood-based patient specimens. METHODS: Following characterization of the absorbance spectrum for metronidazole, spectrophotometric assays involving either main or subtraction wavelengths that might be susceptible to interference from metronidazole were identified. A total of 24 chemistry tests performed on Roche cobas c502 and/or c702 instruments were evaluated for interference from metronidazole. For each assay, two pools of leftover patient serum, plasma, or whole blood specimens containing the analyte of interest at clinically relevant concentrations were prepared. Each pool was spiked with metronidazole at a final concentration of 200 mg/L (1169 µmol/L) or 10 mg/L (58 µmol/L) or the same volume of water as a control, with triplicate samples for each group. The difference in the measured analyte concentration between experimental and control groups was then compared against the total allowable error for each assay to determine whether clinically significant interference had occurred. RESULTS: There was no significant interference observed with Roche chemistry tests due to the presence of metronidazole. CONCLUSION: This study provides reassurance that metronidazole is not interfering with the chemistry assays used in our core laboratory. Interference from metronidazole may be a historical problem and current spectrophotometric assays may not be susceptible due to improvements in assay design.


Asunto(s)
Laboratorios , Metronidazol , Humanos , Espectrofotometría
8.
J Appl Lab Med ; 8(4): 674-688, 2023 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-37207688

RESUMEN

BACKGROUND: Assessment of trace and toxic element status is important for the diagnosis and monitoring of several pediatric conditions. Elemental deficiency and toxicity have serious implications, particularly in pediatrics wherein risk is higher. Pediatric reference intervals (RIs) for trace elements and normal exposure limits for toxic elements are lacking on modern analytical systems. Herein, reference values were established for 13 plasma and 22 whole blood trace elements in the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) cohort of healthy children and adolescents. METHODS: Approximately 320 healthy children and adolescents were recruited with informed consent. Trace elements were measured in whole blood and plasma samples using 2 technologies: (a) triple quadrupole inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) (n = 172) and (b) high-resolution sector field ICPMS (HR-SF-ICPMS) (n =161). RIs and normal exposure limits were then established according to Clinical and Laboratory Standards Institute guidelines. RESULTS: Of all elements assessed, none required sex partitioning and 8 required age partitioning (e.g., copper, manganese, and cadmium). Reference value distributions determined via ICP-MS/MS and HR-SF-ICPMS demonstrated excellent concordance, with few exceptions (e.g., molybdenum, cobalt, and nickel). CONCLUSIONS: These data represent the first study wherein pediatric RIs and normal exposure limits were derived simultaneously on 2 different clinically validated MS platforms which provide urgently needed data to inform clinical decision-making for trace elements in pediatrics. Study findings suggest some trace elements require age-specific consideration for appropriate interpretation. Highly concordant observations across the 2 analytical methods also demonstrate the comparability and reliability of results obtained on both platforms.


Asunto(s)
Servicios de Laboratorio Clínico , Oligoelementos , Humanos , Niño , Adolescente , Oligoelementos/análisis , Valores de Referencia , Espectrometría de Masas en Tándem , Reproducibilidad de los Resultados
10.
Can J Neurol Sci ; 50(5): 766-768, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-35861111

RESUMEN

High anti-GAD65 levels associate with core manifestations of GAD65 neurological autoimmunity. ELISA cut-offs for high anti-GAD65 levels (>10,000 IU/ml in serum, >100 IU/ml in CSF) have been proposed that merit further evaluation. We reviewed patients who underwent anti-GAD65 ELISA for suspected autoimmune encephalitis and found values above these cut-offs to have a positive predictive value (PPV) for neurological autoimmunity of 88%. Anti-GAD65 values above proposed ELISA cut-offs have a reasonably high PPV for neurological autoimmunity in patients with suspected autoimmune encephalitis. Consideration of alternative diagnoses and corroboration with CSF can help flag potentially clinically irrelevant results and avoid patient misdiagnosis.


Asunto(s)
Enfermedades Autoinmunes del Sistema Nervioso , Autoinmunidad , Humanos , Autoanticuerpos , Valor Predictivo de las Pruebas , Ensayo de Inmunoadsorción Enzimática , Enfermedades Autoinmunes del Sistema Nervioso/diagnóstico , Glutamato Descarboxilasa
13.
Cell Rep Methods ; 1(2): 100011, 2021 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-34235498

RESUMEN

We have developed a rapid, accurate, and cost-effective serologic test for SARS-CoV-2 virus, which caused the COVID-19 pandemic, on the basis of antibody-dependent agglutination of antigen-coated latex particles. When validated using plasma samples that are positive or negative for SARS-CoV-2, the agglutination assay detected antibodies against the receptor-binding domain of the spike (S-RBD) or the nucleocapsid protein of SARS-CoV-2 with 100% specificity and ∼98% sensitivity. Furthermore, we found that the strength of the S-RBD antibody response measured by the agglutination assay correlated with the efficiency of the plasma in blocking RBD binding to the angiotensin-converting enzyme 2 in a surrogate neutralization assay, suggesting that the agglutination assay might be used to identify individuals with virus-neutralizing antibodies. Intriguingly, we found that >92% of patients had detectable antibodies on the day of a positive viral RNA test, suggesting that the agglutination antibody test might complement RNA testing for the diagnosis of SARS-CoV-2 infection.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Pandemias , COVID-19/diagnóstico , Anticuerpos Antivirales , Aglutinación
14.
JCI Insight ; 6(13)2021 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-34081630

RESUMEN

BACKGROUNDThe role of humoral immunity in COVID-19 is not fully understood, owing, in large part, to the complexity of antibodies produced in response to the SARS-CoV-2 infection. There is a pressing need for serology tests to assess patient-specific antibody response and predict clinical outcome.METHODSUsing SARS-CoV-2 proteome and peptide microarrays, we screened 146 COVID-19 patients' plasma samples to identify antigens and epitopes. This enabled us to develop a master epitope array and an epitope-specific agglutination assay to gauge antibody responses systematically and with high resolution.RESULTSWe identified linear epitopes from the spike (S) and nucleocapsid (N) proteins and showed that the epitopes enabled higher resolution antibody profiling than the S or N protein antigen. Specifically, we found that antibody responses to the S-811-825, S-881-895, and N-156-170 epitopes negatively or positively correlated with clinical severity or patient survival. Moreover, we found that the P681H and S235F mutations associated with the coronavirus variant of concern B.1.1.7 altered the specificity of the corresponding epitopes.CONCLUSIONEpitope-resolved antibody testing not only affords a high-resolution alternative to conventional immunoassays to delineate the complex humoral immunity to SARS-CoV-2 and differentiate between neutralizing and non-neutralizing antibodies, but it also may potentially be used to predict clinical outcome. The epitope peptides can be readily modified to detect antibodies against variants of concern in both the peptide array and latex agglutination formats.FUNDINGOntario Research Fund (ORF) COVID-19 Rapid Research Fund, Toronto COVID-19 Action Fund, Western University, Lawson Health Research Institute, London Health Sciences Foundation, and Academic Medical Organization of Southwestern Ontario (AMOSO) Innovation Fund.


Asunto(s)
Pruebas de Aglutinación/métodos , Formación de Anticuerpos/inmunología , Prueba Serológica para COVID-19/métodos , COVID-19/inmunología , Epítopos de Linfocito B/inmunología , SARS-CoV-2/inmunología , Secuencia de Aminoácidos , Anticuerpos Neutralizantes/sangre , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/sangre , Anticuerpos Antivirales/inmunología , Especificidad de Anticuerpos/inmunología , COVID-19/sangre , COVID-19/mortalidad , Epítopos/inmunología , Epítopos de Linfocito B/química , Epítopos de Linfocito B/genética , Humanos , Inmunidad Humoral , Análisis por Micromatrices/métodos , Nucleocápside/química , Nucleocápside/genética , Nucleocápside/inmunología , Péptidos/inmunología , SARS-CoV-2/genética , Índice de Severidad de la Enfermedad , Glicoproteína de la Espiga del Coronavirus/química , Glicoproteína de la Espiga del Coronavirus/genética , Glicoproteína de la Espiga del Coronavirus/inmunología
15.
Clin Biochem ; 95: 41-48, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34022172

RESUMEN

BACKGROUND: Coronavirus Disease 2019 (COVID-19) has variable clinical presentation, from asymptomatic to severe disease leading to death. Biochemical markers may help with management and prognostication of COVID-19 patients; however, their utility is still under investigation. METHODS: A retrospective study was conducted to evaluate alanine aminotransferase, C-reactive protein (CRP), ferritin, lactate, and high sensitivity troponin T (TnT) levels in 67 patients who were admitted to a Canadian tertiary care centre for management of COVID-19. Logistic, cause-specific Cox proportional-hazards, and accelerated failure time regression modelling were performed to assess the associations of initial analyte concentrations with in-hospital death and length of stay in hospital; joint modelling was performed to assess the associations of the concentrations over the course of the hospital stay with in-hospital death. RESULTS: Initial TnT and CRP concentrations were associated with length of stay in hospital. Eighteen patients died (27%), and the median initial TnT concentration was higher in patients who died (55 ng/L) than those who lived (16 ng/L; P < 0.0001). There were no survivors with an initial TnT concentration > 64 ng/L. While the initial TnT concentration was predictive of death, later measurements were not. Only CRP had prognostic value with both the initial and subsequent measurements: a 20% increase in the initial CRP concentration was associated with a 14% (95% confidence interval (CI): 1-29%) increase in the odds of death, and the hazard of death increased 14% (95% CI: 5-25%) for each 20% increase in the current CRP value. While the initial lactate concentration was not predictive of death, subsequent measurements were. CONCLUSION: CRP, lactate and TnT were associated with poorer outcomes and appear to be useful biochemical markers for monitoring COVID-19 patients.


Asunto(s)
Proteína C-Reactiva/metabolismo , COVID-19/sangre , Hospitalización/tendencias , Ácido Láctico/sangre , Centros de Atención Terciaria/tendencias , Troponina T/sangre , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Bioquímicos/fisiología , Biomarcadores/sangre , Análisis de los Gases de la Sangre/métodos , Análisis de los Gases de la Sangre/tendencias , COVID-19/diagnóstico , COVID-19/epidemiología , Canadá/epidemiología , Femenino , Humanos , Mediadores de Inflamación/sangre , Tiempo de Internación/tendencias , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
16.
Can J Neurol Sci ; 48(6): 859-863, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33557967

RESUMEN

Neural antibodies have emerged as useful biomarkers in suspected autoimmune encephalitis. We reviewed results of neural antibody testing (anti-N-methyl D-aspartate receptor (NMDAR), leucine-rich glioma-inactivated protein (LGI1), contactin-associated protein-like 2 (CASPR2), α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptor (AMPAR), γ-aminobutyric acid type B receptor (GABA(B)R), dipeptidyl-peptidase-like protein-6 (DPPX), IgLON family member 5 (IgLON5) and glutamic acid decarboxylase-65 (GAD65)) using cell-based assays (CBAs) and tissue indirect immunofluorescence (TIIF) at our centre. Our findings suggest increased clinical sensitivity of CBA compared to TIIF. However, this may come at some expense to clinical specificity, as evidenced by possible false-positive results when weak serum positivity by CBA was observed for certain antibodies (i.e. anti-NMDAR, CASPR2). In such cases, correlation with serum TIIF, as well as CSF CBA and TIIF, aids in identifying true-positive results.


Asunto(s)
Encefalitis , Enfermedad de Hashimoto , Autoanticuerpos , Canadá , Moléculas de Adhesión Celular Neuronal , Encefalitis/diagnóstico , Enfermedad de Hashimoto/diagnóstico , Humanos
17.
Acta Paediatr ; 110(3): 773-780, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32869283

RESUMEN

AIM: Review of current knowledge on assessing renal function in term and preterm neonates. METHODS: Literature review and analysis of own data. RESULTS: Prematurity, genetic, environmental and maternal factors may alter peak nephron endowment and life-long renal function. Nephrogenesis continues until 34-36 weeks of gestation, but it is altered with premature delivery. Variability of nephron endowment has a substantial impact on the clearance of renally excreted drugs. Postnatally, glomerular function rate (GFR) increases daily, doubles by two weeks, and slowly reaches full maturity at 18 months of age. Ideally, renal function biomarkers should be expressed as age-independent z-scores, and evidence suggests indexing these values to post-conceptual age rather than chronological age. Newborn and maternal serum creatinine correlate tightly for more than 72 hours after delivery, rendering this biomarker unsuitable for the assessment of neonatal renal function. Cystatin C does not cross the placenta and may be the preferred biomarker in the neonate. Here, we provide preliminary data on the natural evolution of the cystatin C eGFR in infancy. CONCLUSION: Cystatin C may be superior for GFR estimation in neonates, but the best approach to drug dosing of renally excreted drugs remains to be established.


Asunto(s)
Recién Nacido de Bajo Peso , Recien Nacido Prematuro , Biomarcadores , Creatinina , Femenino , Tasa de Filtración Glomerular , Humanos , Lactante , Recién Nacido , Embarazo
18.
Clin Chem ; 66(12): 1496-1509, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33221892

RESUMEN

BACKGROUND: Autoimmunity is an increasingly recognized cause of encephalitis with a similar prevalence to that of infectious etiologies. Over the past decade there has been a rapidly expanding list of antibody biomarker discoveries that have aided in the identification and characterization of autoimmune encephalitis. As the number of antibody biomarkers transitioning from the research setting into clinical laboratories has accelerated, so has the demand and complexity of panel-based testing. Clinical laboratories are increasingly involved in discussions related to test utilization and providing guidance on which testing methodologies provide the best clinical performance. CONTENT: To ensure optimal clinical sensitivity and specificity, comprehensive panel-based reflexive testing based on the predominant neurological phenotypic presentation (e.g., encephalopathy) is ideal in the workup of cases of suspected autoimmune neurological disease. Predictive scores based on the clinical workup can aid in deciding when to order a test. Testing of both CSF and serum is recommended with few exceptions. Appropriate test ordering and interpretation requires an understanding of both testing methodologies and performance of antibody testing in different specimen types. SUMMARY: This review discusses important considerations in the design and selection of neural antibody testing methodologies and panels. Increased collaboration between pathologists, laboratorians, and neurologists will lead to improved utilization of complex autoimmune neurology antibody testing panels.


Asunto(s)
Encefalitis , Enfermedad de Hashimoto , Autoanticuerpos , Encefalitis/diagnóstico , Enfermedad de Hashimoto/diagnóstico , Humanos
20.
BMJ Open Qual ; 9(1)2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32098778

RESUMEN

INTRODUCTION: Testing of 25-hydroxy (25-OH) vitamin D serum levels has increased drastically in recent years and much of it is considered inappropriate based on current guidelines. METHODS: In consultation with our physician groups (experts and frequent orderers), we modified existing guidelines and implemented a rational policy for 25-OH vitamin D testing and 1,25 dihydroxy (1,25 di-OH) vitamin D testing at a tertiary care centre. A computer decision support tool requiring selection of one of five acceptable testing indications was created for each test as part of a computerised physician order entry system. RESULTS: As a result of our intervention, we observed a 27% decrease in the average monthly test volume for 25-OH vitamin D from 504±62 (mean±SD) tests per month to 370±33 (p<0.001). 1,25 di-OH vitamin D testing decreased 58% from 71±18 to 30±10 (p<0.001). The departments ordering the tests were similar during the preintervention and postintervention periods, and further audits, patient chart reviews and individualised physician feedback were required to ensure appropriate ordering of 1,25 di-OH vitamin D. The most common ordering reasons selected were malabsorption/dietary concerns (46%) for 25-OH vitamin D and renal failure (42%) for 1,25 di-OH vitamin D. CONCLUSIONS: Limitations of our computer decision support tool include a dependence on an honour system in selecting the testing indication and an inability to limit ordering frequency. Periodic monitoring of test volumes will be required to ensure adherence to guidelines. Despite these limitations, we have improved appropriate utilisation of these tests and reduced costs by approximately $C60 375 per year.


Asunto(s)
Uso Excesivo de los Servicios de Salud/prevención & control , Vitamina D/análisis , Canadá , Humanos , Uso Excesivo de los Servicios de Salud/estadística & datos numéricos , Centros de Atención Terciaria/organización & administración , Centros de Atención Terciaria/estadística & datos numéricos , Vitamina D/sangre , Deficiencia de Vitamina D/sangre , Deficiencia de Vitamina D/diagnóstico