Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 217
Filtrar
1.
Gastro Hep Adv ; 3(7): 1012-1019, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39309370

RESUMEN

Background and Aims: In 2013, the Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) steering group published recommendations to standardize reporting quality in randomized controlled trials (RCTs). We aim to assess adherence to SPIRIT reporting guidelines in RCTs on endoscopic colorectal cancer (CRC) screening and participants' adherence to trial protocols. Methods: We searched databases for RCTs evaluating flexible sigmoidoscopy or colonoscopy for CRC screening published in English language through September 2023. Each eligible study was evaluated using the 8 core SPIRIT statement areas, totaling 51 points. Each item received 1 point if it met the criteria and 0 points if it did not. Adherence to SPIRIT items was calculated, and participant adherence to RCT protocols was assessed as the proportion of participants screened compared to those invited. Results: Five RCTs, including 4 on flexible sigmoidoscopy and 1 on colonoscopy, were analyzed. Adherence to SPIRIT guidance ranged from 82.4% to 92.2%. The most missed recommendation was item 2b (trial registrations), scored 0 across all studies. Additionally, item 32 (informed consent materials) scored 20%, and items 17a & b (blinding) scored 40% each. In total, 587,572 participants were randomized across the 5 RCTs. Of these, 37% (200,610) underwent CRC screening, with 69.8% (139,983/200,610) adhering to the protocol. The Nordic-European Initiative on Colorectal Cancer (NordICC) trial, employing a unique invitation method, had a lower adherence rate of 42%. Excluding this trial would raise the adherence rate to 74.3% (128,050/172,390). Conclusion: The published CRC screening trials have acceptable adherence to the SPIRIT reporting guidelines. However, reporting appended consent form materials and disclosing all WHO trial registration data can be improved.

4.
Clin Endosc ; 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39188119

RESUMEN

Background/Aims: Cold snare polypectomy (CSP) is routinely performed for small colorectal polyps (≤10 mm). However, challenges include insufficient resection depth and immediate bleeding, hindering precise pathological evaluation. We aimed to compare the outcomes of cold endoscopic mucosal resection (CEMR) with that of CSP for colorectal polyps ≤10 mm, using data from randomized controlled trials (RCTs). Methods: Multiple databases were searched in December 2023 for RCTs reporting outcomes of CSP versus CEMR for colorectal polyps ≤10 mm in size. Our primary outcomes were rates of complete and en-bloc resections, while our secondary outcomes were total resection time (seconds) and adverse events, including immediate bleeding, delayed bleeding, and perforation. Results: The complete resection rates did not significantly differ (CSP, 91.8% vs. CEMR 94.6%), nor did the rates of en-bloc resection (CSP, 98.9% vs. CEMR, 98.3%) or incomplete resection (CSP, 6.7% vs. CEMR, 4.8%). Adverse event rates were similarly insignificant in variance. However, CEMR had a notably longer mean resection time (133.51 vs. 91.30 seconds). Conclusions: Our meta-analysis of seven RCTs showed that while both CSP and CEMR are equally safe and effective for resecting small (≤10 mm) colorectal polyps, the latter is associated with a longer resection time.

5.
Gastroenterology ; 2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-39098510
9.
J Clin Gastroenterol ; 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39008570

RESUMEN

GOALS: This systematic review aims to evaluate the risk factors, clinical features, and outcomes of bowel perforation caused by stent migration after endoscopic retrograde cholangiopancreatography (ERCP). BACKGROUND: Distal migration of biliary stents can occur after ERCP. Upon migration, most stents pass through the intestine without adverse events; however, bowel perforation has been reported. STUDY: A comprehensive literature search of PubMed, EMBASE, and Cochrane databases was conducted through October 2023 for articles that reported bowel perforation because of stent migration. Cases of incomplete stent migration and proximal stent migration were excluded. We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines to identify full-length articles in English reporting. RESULTS: Of 2041 articles retrieved on the initial search, 92 met the inclusion criteria. A total of 132 cases of bowel perforation occurred due to stent migration after ERCP (56.1% female; average age: 66 y). The median time from initial ERCP to perforation was 44.5 days (IQR 12.5-125.5). Most cases of perforation occurred in the small bowel (64.4%) compared with the colon (34.8%). Stents were mostly plastic (87.1%) with a median diameter of 10 Fr (IQR 8.5-10) and median length of 10.3 cm (IQR 715). Surgical management was pursued in 52.3% and endoscopic management in 42.4%. Bowel resection was required for 25.8% of patients. The overall mortality rate was 17.4%. CONCLUSION: In summary, this study demonstrates that bowel perforation after ERCP stent migration primarily occurs within 44.5 days and most frequently with a 10 Fr plastic biliary stent. The overall mortality rate was 17.4%. It is important for endoscopists to be mindful of this rare but serious adverse event.

10.
Surg Endosc ; 38(8): 4186-4197, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38987483

RESUMEN

BACKGROUND AND AIMS: Biliary drainage is vital in managing malignant biliary obstruction (MBO). Suprapapillary stenting has emerged as a viable alternative to transpapillary stenting and is performed using inside plastic (iPS) or metal stents (iMS). This meta-analysis aims to evaluate the outcomes of suprapapillary stent placement for MBO. METHODS: The Embase, PubMed, and Web of Science databases were systematically searched to include all studies published before September 31, 2023, that reported on the outcomes of suprapapillary stents placed for MBO. Using the random-effect model, the pooled, weight-adjusted event rate estimate for the clinical outcomes was calculated with 95% confidence intervals (CIs). RESULTS: Twenty-eight studies were included, with a total of 1401 patients. The pooled clinical success rate was 98.9%. A subgroup analysis yielded non-significant differences between the iPS and iMS groups (99.3% vs. 98.6%, respectively; P = 0.44). The pooled incidence rate of adverse events (AE) with suprapapillary stents was 9.5%. In a subgroup analysis, the incidence of AEs with iPS was 10.7% compared to 9% in the iMS group without a statistical difference (P = 0.32). The most common adverse event was cholangitis (2.2%), followed by pancreatitis (1.1%), cholecystitis (0.5%), and bleeding (0.12%). CONCLUSION: When technically feasible, suprapapillary stenting for MBO is a viable endoscopic option with a high clinical success rate and acceptable adverse event rates. Both iPS and iMS exhibit similar efficacy.


Asunto(s)
Colestasis , Plásticos , Stents , Humanos , Colestasis/cirugía , Colestasis/etiología , Stents/efectos adversos , Metales , Neoplasias de los Conductos Biliares/complicaciones , Neoplasias de los Conductos Biliares/cirugía , Drenaje/métodos , Drenaje/instrumentación , Resultado del Tratamiento
11.
Am J Gastroenterol ; 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39016372

RESUMEN

INTRODUCTION: While ubiquity of glucagon-like peptide receptor agonists (GLP1-RAs) is rising, guidance from the gastroenterology societies and American Society of Anesthesiologist (ASA) remains in conflict on recommendations regarding preoperative holding before endoscopy. The aim of this study was to address this by evaluating the effect of GLP1-RAs on gastric retention during upper endoscopy. METHODS: This multicenter cross-sectional study included patients on confirmed GLP1-RAs receiving an endoscopy from 2021 to 2023. Demographics, prescribing practices, and procedure outcomes were captured. GLP1-RA management of preoperative holding was retroactively classified per ASA guidance. Multivariable logistic regression was performed to assess factors influencing retained gastric contents. RESULTS: Of 815 patients, 70 (8.7%) had retained gastric contents on endoscopy of whom 65 (93%) had type 2 diabetes mellitus. Only 1 (1.4%) of these patients required unplanned intubation, and none had aspiration events. Those with GLP1-RA held per ASA guidance (406, 49.8%) were less likely to have retained contents (4.4% vs 12.7%, P < 0.001), but there were no significant differences to intubation (0% vs 2%, P = 0.53) or aborting procedure rates (28% vs 18%, P = 0.40) due to gastric retention. On multivariable analysis, likelihood of food retention increased 36% (95% confidence interval 1.15-1.60) for every 1% increase in hemoglobin A1C after adjusting for GLP1-RA type and preoperative medication hold. DISCUSSION: In this multicenter study, very low rates of retained gastric contents were seen during endoscopy in patients on GLP1-RAs and most were in patients with type 2 diabetes mellitus. Our findings suggest an individualized approach rather than universal preoperative holding of medications before endoscopy.

12.
J Clin Med ; 13(13)2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38999449

RESUMEN

Background/Objectives: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) has emerged as an alternative option for biliary drainage in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). Limited data exist on the safety and efficacy of EUS-HGS. In this comprehensive meta-analysis, we aim to study the safety and efficacy of EUS-HGS in cases of failed conventional ERCP. Methods: Embase, PubMed, and Web of Science databases were searched to include all studies that evaluated the efficacy and safety of EUS-HGS. Using the random effect model, the pooled weight-adjusted event rate estimate for clinical outcomes in each group were calculated with 95% confidence intervals (CIs). The primary outcomes were technical and clinical success rates. Secondary outcomes included overall adverse events (AEs), rates of recurrent biliary obstruction (RBO), and rates or re-intervention. Results: Our analysis included 70 studies, with a total of 3527 patients. The pooled technical and clinical success rates for EUS-HGS were 98.1% ([95% CI, 97.5-98.7]; I2 = 40%) and 98.1% ([95% CI, 97.5-98.7]; I2 = 40%), respectively. The pooled incidence rate of AEs with EUS-HGS was 14.9% (95% CI, 12.7-17.1), with bile leakage being the most common (2.4% [95% CI, 1.7-3.2]). The pooled incidence of RBO was 15.8% [95% CI, 12.2-19.4], with a high success rate for re-intervention (97.5% [95% CI, 94.7-100]). Conclusions: Our analysis showed high technical and clinical success rates of EUS-HGS, making it a feasible and effective alternative to ERCP. The ongoing development of dedicated devices and techniques is expected to make EUS-HGS more accessible and safer for patients in need of biliary drainage.

13.
Dig Dis Sci ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926222

RESUMEN

BACKGROUND AND AIM: Luminal strictures, common in inflammatory bowel disease (IBD), especially Crohn's disease (CD), are typically treated with endoscopic balloon dilatation (EBD). The newer endoscopic stricturotomy (ESt) approach shows promise, but data is limited. This systematic review and meta-analysis assess the effectiveness and safety of ESt in IBD-related strictures. METHODS: A comprehensive literature search was conducted until November 2023 for studies assessing ESt efficacy and safety in IBD. Primary outcomes were clinical and technical success, with secondary endpoints covering adverse events, subsequent stricture surgery, additional endoscopic treatments (ESt or EBD), medication escalation, disease-related emergency department visits, and hospitalization post-ESt. Technical success was defined as passing the scope through the stricture, and clinical success was defined as symptom improvement. Single-arm meta-analysis (CMA version 3) calculated the event rate per patient with a 95% confidence interval (CI). Heterogeneity was evaluated using I2. RESULTS: Nine studies were included, involving 640 ESt procedures on 287 IBD patients (169 CD, 118 ulcerative colitis). Of these, 53.3% were men, with a mean age of 43.3 ± 14.3 years and a mean stricture length of 1.68 ± 0.84 cm. The technical success rate was 96.4% (95% CI 92.5-98.3, p-value < 0.0001), and the clinical success rate was 62% (95% CI 52.2-70.9, p-value = 0.017, I2 = 34.670). The bleeding rate was 10.5% per patient, and the perforation rate was 3.5%. After an average follow-up of 0.95 ± 1.1 years, 16.4% required surgery for strictures post-ESt, while 44.2% needed additional endoscopic treatment. The medication escalation rate after ESt was 14.7%. The disease-related emergency department visit rate was 14.7%, and the disease-related hospitalization rate post-procedure was 21.3%. CONCLUSION: Our analysis shows that ESt is safe and effective for managing IBD-related strictures, making it a valuable addition to the armamentarium of endoscopists. Formal training efforts should focus on ensuring its widespread adoption.

14.
Endosc Int Open ; 12(6): E750-E756, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38847016

RESUMEN

Inadequate bowel preparation is common despite various preprocedure interventions. There is a need for an intervention at the time of colonoscopy to combat poor preparation. In this retrospective, observational study of 46 patients, we evaluated the clinical efficacy and feasibility of implementing the third generation of the Pure-Vu EVS System, a US Food and Drug Administration-cleared over-the-scope-based intraprocedural cleansing device, into our practice at the Minneapolis VA Medical Center (Minneapolis, Minnesota, United States). To study clinical efficacy, we measured bowel preparation adequacy before and after using the device, as measured by the Boston Bowel Preparation Score, and reviewed colonoscopy surveillance interval recommendations. Technical success and feasibility of using the device were measured by procedure success rates and duration. We found that BBPS scores increased from 4.4 to 7.9 when using the device. Technical success was achieved 78.3% of the time (36/46 cases). Median colonoscopy duration was 46 minutes, although there was a trend toward shorter procedures over time. This is the first clinical evaluation of the third generation of an intraprocedural cleansing device. We found the device efficacious and easy to use with low procedure failure rates, but it does come with a learning curve. We suspect that adoption of this device mutually will benefit patients and health systems with the potential to improve resource utilization.

15.
J Clin Med ; 13(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38731022

RESUMEN

Background/Objectives: This study aimed to investigate the association between colorectal cancer (CRC) and the risk of breakthrough respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in vaccinated patients with CRC. Methods: This retrospective cohort study used the TriNetX research network to identify vaccinated patients with CRC. Patients were matched using propensity score matching (PSM) and divided into patients with CRC and control (without history of CRC) groups. The primary outcome was the risk of breakthrough SARS-CoV-2 in vaccinated patients. The secondary outcome was a composite of all-cause emergency department (ED) visits, hospitalization, and death during the follow-up period after the diagnosis of COVID-19. Results: A total of 15,416 vaccinated patients with CRC were identified and propensity matched with 15,416 vaccinated patients without CRC. Patients with CRC had a significantly increased risk for breakthrough infections compared to patients without CRC (aOR = 1.78; [95% CI: 1.47-2.15]). Patients with CRC were at increased risk of breakthrough SARS-CoV-2 infections after two doses (aOR = 1.71; [95% CI: 1.42-2.06]) and three doses (aOR = 1.36; [95% CI: 1.09-1.69]) of SARS-CoV-2 vaccine. Vaccinated patients with CRC were at a lower risk of COVID-19 infection than unvaccinated CRC patients (aOR = 0.342; [95% CI: 0.289-0.404]). The overall composite outcome (all-cause ED visits, all-cause hospitalization, and all-cause death) was 51.6% for breakthrough infections, which was greater than 44.3% for propensity score-matched patients without CRC (aOR = 1.79; [95% CI: 1.29-2.47]). Conclusions: This cohort study showed significantly increased risks for breakthrough SARS-CoV-2 infection in vaccinated patients with CRC. Breakthrough SARS-CoV-2 infections in patients with CRC were associated with significant and substantial risks for hospitalizations.

16.
Dig Dis Sci ; 69(6): 2018-2025, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38580887

RESUMEN

INTRODUCTION: Pancreatic duct stents (PDS) are widely used for the prevention of post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis. However, there is a paucity of data regarding the adverse events associated with PDS placement. This study aims to investigate the reported adverse events and device failures related to PDS, utilizing the Manufacturer and User Facility Device Experience (MAUDE) database maintained by the U.S. Food and Drug Administration (FDA). METHODS: Post-marketing surveillance data from January 2013 to December 8, 2023, were extracted from the FDA's MAUDE database to analyze the reports pertaining to the use of commonly used PDS. The primary outcomes of interest were device issues and patient-related adverse events. Statistical analysis was performed using Microsoft Excel 2010, with the calculation of pooled numbers and percentages for each device and patient adverse event. RESULTS: A total of 579 device issues and 194 patient-related adverse events were identified. Device issues were primarily attributed to stent deformation (n = 72; 12.4%), followed by migration of the device into the pancreatic duct or expulsion out of the duct (n = 60; 10.4%), and stent fracture/breakage (n = 55; 9.4%). Among the patient-reported adverse events, inflammation was the most common (n = 26; 13.4%), followed by reports of stents becoming embedded in tissue (n = 21; 10.8%) and stent occlusion/obstruction (n = 16; 8.2%). The most prevalent device failures associated with Advanix stents were material deformation, with perforation (n = 3, 30%) being the most frequently reported adverse event. Concerning Geenen stents, migration or expulsion of the device (n = 34, 16.9%) constituted the most common device-related adverse events, while inflammation (n = 20, 16.7%) was the most frequently reported patient-related issue. For Zimmon stents, migration or expulsion of the device (n = 22, 8.8%) were the most frequently reported device-related problems, whereas perforation (n = 7, 10.9%) and bleeding (n = 7, 10.9%) were the most frequent patient-related adverse events. CONCLUSION: Our findings highlight important device and patient adverse events that endoscopists and referring providers should be aware of before considering pancreatic stent placement.


Asunto(s)
Bases de Datos Factuales , Conductos Pancreáticos , Vigilancia de Productos Comercializados , Falla de Prótesis , Stents , United States Food and Drug Administration , Humanos , Estados Unidos/epidemiología , Stents/efectos adversos , Conductos Pancreáticos/cirugía , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colangiopancreatografia Retrógrada Endoscópica/instrumentación , Pancreatitis/etiología , Pancreatitis/epidemiología , Pancreatitis/prevención & control , Falla de Equipo/estadística & datos numéricos , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/epidemiología , Migración de Cuerpo Extraño/prevención & control
18.
ACG Case Rep J ; 11(4): e01320, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38560015

RESUMEN

Acute pancreatitis is a common gastroenterological condition that can occur due to several causes. While not required for diagnosis, imaging is often performed and may reveal unexpected findings such as pancreatic masses. Malignancies such as lymphoma are uncommon causes of acute pancreatitis, especially as the initial presentation of malignancy. We present a case of a young patient with acute pancreatitis caused by diffuse large B-cell lymphoma with extranodal disease secondarily involving the pancreas. Our case highlights the importance of keeping a broad differential for acute pancreatitis and considering rare etiologies such as pancreatic lymphoma in patients without another obvious culprit.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA