Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Abdom Radiol (NY) ; 45(12): 4260-4270, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32696213

RESUMEN

PURPOSE: To subjectively and quantitatively compare the quality of 3 Tesla magnetic resonance imaging of the prostate acquired with a novel flexible surface coil (FSC) and with a conventional endorectal coil (ERC). METHODS: Six radiologists independently reviewed 200 pairs of axial, high-resolution T2-weighted and diffusion-weighted image data sets, each containing one examination acquired with the FSC and one with the ERC, respectively. Readers selected their preferred examination from each pair and assessed every single examination using six quality criteria on 4-point scales. Signal-to-noise ratios were measured and compared. RESULTS: Two readers preferred FSC acquisition (36.5-45%) over ERC acquisition (13.5-15%) for both sequences combined, and four readers preferred ERC acquisition (41-46%). Analysis of pooled responses for both sequences from all readers shows no significant preference for FSC or ERC. Analysis of the individual sequences revealed a pooled preference for the FSC in T2WI (38.7% vs 17.8%) and for the ERC in DWI (50.9% vs 19.6%). Patients' weight was the only weak predictor of a preference for the ERC acquisition (p = 0.04). SNR and CNR were significantly higher in the ERC acquisitions (p<0.001) except CNR differentiating tumor lesions from benign prostate (p=0.1). CONCLUSION: Although readers have strong individual preferences, comparable subjective image quality can be obtained for prostate MRI with an ERC and the novel FSC. ERC imaging might be particularly valuable for sequences with inherently lower SNR as DWI and larger patients whereas the FSC is generally preferred in T2WI. FSC imaging generates a lower SNR than with an ERC.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Humanos , Imagen por Resonancia Magnética , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Relación Señal-Ruido
2.
Br J Radiol ; 85(1019): 1446-56, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22932061

RESUMEN

Pulmonary hypertension (PH) is a progressive disease that leads to substantial morbidity and eventual death. Pulmonary multidetector CT angiography (MDCTA), pulmonary MR angiography (MRA) and MR-derived pulmonary perfusion (MRPP) imaging are non-invasive imaging techniques for the differential diagnosis of PH. MDCTA is considered the gold standard for the diagnosis of pulmonary embolism, one of the most common causes of PH. MRA and MRPP are promising techniques that do not require the use of ionising radiation or iodinated contrast material, and can be useful for patients for whom such material cannot be used. This review compares the imaging aspects of pulmonary MRA and 64-row MDCTA in patients with chronic thromboembolic or idiopathic PH.


Asunto(s)
Angiografía/métodos , Hipertensión Pulmonar/diagnóstico por imagen , Angiografía por Resonancia Magnética , Tomografía Computarizada por Rayos X/métodos , Diagnóstico Diferencial , Hipertensión Pulmonar Primaria Familiar , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/patología , Angiografía por Resonancia Magnética/métodos , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA