Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Hand Ther ; 33(3): 314-319, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32088082

RESUMEN

STUDY DESIGN: A prospective cohort single-center study. INTRODUCTION: Self-efficacy (SE) refers to beliefs in ones capabilities to organize and execute the courses of action required to produce given goals. High SE is an important factor for recovery from injury/illness; people who believe in their capability will more likely reach a good outcome. PURPOSE OF THE STUDY: The aim of this study was to examine if SE has an effect to physical functioning, pain and patient-rated wrist function three months postoperatively in patients undergoing plating due to a distal radius fracture. METHODS: Sixty-seven patients undergoing plating for a distal radius fracture rated SE at the first appointment with the physiotherapist. At the three-month follow-up, the following assessments were administered: Patient-Rated Wrist Evaluation (PRWE), pain-scores, hand grip strength, and range of motion. RESULTS: The group with a high SE showed significantly better range of motion for flexion (P = .046) and supination (P = .045), hand grip strength (P = .001) and PRWE scores (P = .04). The NRS pain during activity was lower, although not significantly lower (P = .09). Using Spearman's rank correlation coefficient, there was a moderate correlation between SE and pain during activity, wrist flexion, and PRWE score. DISCUSSION: SE corresponds to wrist function after combined plating of distal radius fractures. CONCLUSION: Measurement of SE could possibly be useful to identify patients in special need of support during the postoperative rehabilitation.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas del Radio/psicología , Fracturas del Radio/cirugía , Autoeficacia , Articulación de la Muñeca/fisiopatología , Adulto , Anciano , Femenino , Fuerza de la Mano , Humanos , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Pronación , Estudios Prospectivos , Fracturas del Radio/rehabilitación , Rango del Movimiento Articular , Recuperación de la Función , Supinación , Resultado del Tratamiento
2.
Anal Bioanal Chem ; 405(8): 2607-17, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23292043

RESUMEN

An efficient method for analyzing illegal and medicinal drugs in whole blood using fully automated sample preparation and short ultra-high-performance liquid chromatography-tandem mass spectrometry (MS/MS) run time is presented. A selection of 31 drugs, including amphetamines, cocaine, opioids, and benzodiazepines, was used. In order to increase the efficiency of routine analysis, a robotic system based on automated liquid handling and capable of handling all unit operation for sample preparation was built on a Freedom Evo 200 platform with several add-ons from Tecan and third-party vendors. Solid-phase extraction was performed using Strata X-C plates. Extraction time for 96 samples was less than 3 h. Chromatography was performed using an ACQUITY UPLC system (Waters Corporation, Milford, USA). Analytes were separated on a 100 mm × 2.1 mm, 1.7 µm Acquity UPLC CSH C(18) column using a 6.5 min 0.1 % ammonia (25 %) in water/0.1 % ammonia (25 %) in methanol gradient and quantified by MS/MS (Waters Quattro Premier XE) in multiple-reaction monitoring mode. Full validation, including linearity, precision and trueness, matrix effect, ion suppression/enhancement of co-eluting analytes, recovery, and specificity, was performed. The method was employed successfully in the laboratory and used for routine analysis of forensic material. In combination with tetrahydrocannabinol analysis, the method covered 96 % of cases involving driving under the influence of drugs. The manual labor involved in preparing blood samples, solvents, etc., was reduced to a half an hour per batch. The automated sample preparation setup also minimized human exposure to hazardous materials, provided highly improved ergonomics, and eliminated manual pipetting.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Cromatografía Líquida de Alta Presión/estadística & datos numéricos , Drogas Ilícitas/sangre , Preparaciones Farmacéuticas/sangre , Extracción en Fase Sólida/métodos , Detección de Abuso de Sustancias/métodos , Espectrometría de Masas en Tándem/métodos , Automatización , Humanos , Drogas Ilícitas/aislamiento & purificación , Drogas Ilícitas/metabolismo , Preparaciones Farmacéuticas/aislamiento & purificación , Preparaciones Farmacéuticas/metabolismo
3.
J Biomol Screen ; 15(6): 671-9, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20581078

RESUMEN

15-Lipoxygenase-1 catalyzes the introduction of molecular oxygen into polyunsaturated fatty acids to form a lipid hydroperoxide. The authors have developed an assay for the detection of lipid hydroperoxides formed by human 15-lipoxygenase (15-LO) in enzyme or cellular assays using either a 96-well or a 384-well format. The assays described take advantage of the ability of lipid hydroperoxides to oxidize nonfluorescent diphenyl-1-pyrenylphosphine (DPPP) to a fluorescent phosphine oxide. Oxidation of DPPP yields a fluorescent compound, which is not sensitive to temperature and is stable for more than 2 h. The assay is sensitive toward inhibition and robust with a Z' value of 0.79 and 0.4 in a 96- and 384-well format, respectively, and thus amenable for high-throughput screening. The utility of DPPP as a marker for 15-lipoxygenase activity was demonstrated with both enzyme- and cell-based assays for the identification of hits and to determine potency by IC(50) determinations.


Asunto(s)
Araquidonato 15-Lipooxigenasa/metabolismo , Ensayos Analíticos de Alto Rendimiento/métodos , Antioxidantes/farmacología , Araquidonato 15-Lipooxigenasa/aislamiento & purificación , Bioensayo , Línea Celular Tumoral , Cromatografía Liquida , Clonación Molecular , Pruebas de Enzimas , Fluorescencia , Humanos , Concentración 50 Inhibidora , Peróxidos Lipídicos/metabolismo , Compuestos Organofosforados/química , Compuestos Organofosforados/metabolismo , Oxidación-Reducción/efectos de los fármacos , Pirenos/química , Pirenos/metabolismo , Reproducibilidad de los Resultados , Bibliotecas de Moléculas Pequeñas/análisis , Bibliotecas de Moléculas Pequeñas/farmacología
4.
Anal Bioanal Chem ; 396(7): 2393-401, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19921510

RESUMEN

A high-performance liquid chromatography (LC)-tandem mass spectrometry (MS/MS) method has been developed and validated for the determination of 19 drugs of abuse and metabolites and used in whole blood. The following compounds were included: amphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethamphetamine, methamphetamine, cocaine, benzoylecgonine, morphine, 6-acetylmorphine, codeine, methadone, buprenorphine, norbuprenorphine, ketobemidone, tramadol, O-desmethyltramadol, zaleplone, zolpidem, and zopiclone. The sample pretreatment consisted of solid-phase extraction using mixed-mode columns (Isolute Confirm HCX). Deuterated analogues were used as internal standards for all analytes, except for ketobemidone and O-desmethyltramadol. The analytes were separated by a methanol/ammonium formate gradient using high-performance LC (Agilent HPLC 1100) with a 3 mm x 100 mm Varian Pursuit 3 C(18) column, 3-microm particle size, and were quantified by MS/MS (Waters Quattro micro tandem quadrupole mass spectrometer) using multiple reaction monitoring in positive mode. Two transitions were used for all analytes, except for tramadol and O-desmethyltramadol. The run time of the method was 35 min including the equilibration time. For all analytes, responses were linear over the range investigated, with R(2) > 0.99. One-point calibration was found to be adequate by validation, thereby saving analysis of multiple calibrators. The limits of quantification (LOQs) for the analytes ranged from 0.0005 to 0.01 mg/kg. Absolute recoveries of the analytes were from 34 to 97%, except for zaleplone (6%). Both the interday precision and the intraday precision were less than 15% (20% at the LOQ) for all analytes, except buprenorphine, norburprenorphine, and zaleplone (less than 18%). Accuracy (bias) was within +/-15% (+/-20% at the LOQ) for all analytes, except MDMA and O-desmethyltramadol (within +/-19%). No ion suppression or enhancement was seen nor was suppression from coeluted analytes seen. Matrix effects were found to be less than 23% for all analytes, except zopiclone (64%). High-concentration and low-concentration quality control samples gave acceptable values, and the method has been tried in international proficiency test schemes with good results. The present LC-MS/MS method provides a simple, specific, and sensitive solution for the quantification of some of the most frequent drugs of abuse and their metabolites in whole blood. The quantification by LC-MS/MS was successfully applied to 412 forensic cases from October 2008 to mid February 2009, where 267 cases were related to zero-tolerance traffic legislation.


Asunto(s)
Análisis Químico de la Sangre/métodos , Cromatografía Líquida de Alta Presión/métodos , Mezclas Complejas/análisis , Drogas Ilícitas/sangre , Espectrometría de Masas/métodos , Detección de Abuso de Sustancias/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS