Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Lancet Infect Dis ; 19(2): 193-202, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30655049

RESUMEN

BACKGROUND: The clinical utility of interferon-γ release assays (IGRAs) for diagnosis of active tuberculosis is unclear, although they are commonly used in countries with a low incidence of tuberculosis. We aimed to resolve this clinical uncertainty by determining the accuracy and utility of commercially available and second-generation IGRAs in the diagnostic assessment of suspected tuberculosis in a low-incidence setting. METHODS: We did a prospective cohort study of adults with suspected tuberculosis in routine secondary care in England. Patients were tested for Mycobacterium tuberculosis infection at baseline with commercially available (T-SPOT.TB and QuantiFERON-TB Gold In-Tube [QFT-GIT]) and second-generation (incorporating novel M tuberculosis antigens) IGRAs and followed up for 6-12 months to establish definitive diagnoses. Sensitivity, specificity, positive and negative likelihood ratios, and predictive values of the tests were determined. FINDINGS: Of the 1060 adults enrolled in the study, 845 were included in the analyses and 363 were diagnosed with tuberculosis. Sensitivity of T-SPOT.TB for all tuberculosis diagnosis, including culture-confirmed and highly probable cases, was 81·4% (95% CI 76·6-85·3), which was higher than QFT-GIT (67·3% [62·0-72·1]). Second-generation IGRAs had a sensitivity of 94·0% (90·0-96·4) for culture-confirmed tuberculosis and 89·2% (85·2-92·2) when including highly probable tuberculosis, giving a negative likelihood ratio for all tuberculosis cases of 0·13 (95% CI 0·10-0·19). Specificity ranged from 86·2% (95% CI 82·3-89·4) for T-SPOT.TB to 80·0% (75·6-83·8) for second-generation IGRAs. INTERPRETATION: Commercially available IGRAs do not have sufficient accuracy for diagnostic evaluation of suspected tuberculosis. Second-generation tests, however, might have sufficiently high sensitivity, low negative likelihood ratio, and correspondingly high negative predictive value in low-incidence settings to facilitate prompt rule-out of tuberculosis. FUNDING: National Institute for Health Research.


Asunto(s)
Ensayos de Liberación de Interferón gamma/métodos , Ensayos de Liberación de Interferón gamma/normas , Mycobacterium tuberculosis/inmunología , Tuberculosis Pulmonar/diagnóstico , Tuberculosis Pulmonar/epidemiología , Adulto , Antígenos Bacterianos/inmunología , Proteínas Bacterianas/inmunología , Exactitud de los Datos , Inglaterra/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Tuberculosis Pulmonar/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA