Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
1.
Radiol Med ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38935247

RESUMEN

PURPOSE: To determine the optimal window setting for virtual monoenergetic images (VMI) reconstructed from dual-layer spectral coronary computed tomography angiography (DE-CCTA) datasets. MATERIAL AND METHODS: 50 patients (30 males; mean age 61.1 ± 12.4 years who underwent DE-CCTA from May 2021 to June 2022 for suspected coronary artery disease, were retrospectively included. Image quality assessment was performed on conventional images and VMI reconstructions at 70 and 40 keV. Objective image quality was assessed using contrast-to-noise ratio (CNR). Two independent observers manually identified the best window settings (B-W/L) for VMI 70 and VMI 40 visualization. B-W/L were then normalized with aortic attenuation using linear regression analysis to obtain the optimized W/L (O-W/L) settings. Additionally, subjective image quality was evaluated using a 5-point Likert scale, and vessel diameters were measured to examine any potential impact of different W/L settings. RESULTS: VMI 40 demonstrated higher CNR values compared to conventional and VMI 70. B-W/L settings identified were 1180/280 HU for VMI 70 and 3290/900 HU for VMI 40. Subsequent linear regression analysis yielded O-W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40. VMI 40 O-W/L received the highest scores for each parameter compared to conventional (all p < 0.0027). Using O-W/L settings for VMI 70 and VMI 40 did not result in significant differences in vessel measurements compared to conventional images. CONCLUSION: Optimization of VMI requires adjustments in W/L settings. Our results recommend W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40.

2.
BMC Med Imaging ; 24(1): 145, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38872126

RESUMEN

BACKGROUND: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS: Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS: 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.


Asunto(s)
Implantes Cocleares , Tomografía Computarizada de Haz Cónico , Dosis de Radiación , Hueso Temporal , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Masculino , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Hueso Temporal/diagnóstico por imagen , Anciano , Adulto , Implantación Coclear/métodos
3.
Acad Radiol ; 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38862346

RESUMEN

RATIONALE AND OBJECTIVES: This retrospective study evaluates the efficacy and safety of Prostatic Artery Embolization (PAE) for the treatment of benign prostatic hyperplasia (BPH) over five years at a single center, conducted by an experienced interventional radiologist. MATERIALS AND METHODS: We analyzed 551 PAE interventions from January 2019 to July 2023. Key metrics included patient demographics, procedural details (radiation exposure, particle size), complication rates, pre- and post-interventional prostatic volume (PV), Prostate-specific Antigen (PSA) levels, International Prostate Symptom Score (IPSS), Quality of Life (QoL) scores and International Index of Erectile Function (IIEF) scores. We assessed data normality, performed group and paired sample comparisons, and evaluated correlations. RESULTS: For 551 men, the average patient age was 68.81 ± 8.61 years undergoing bilateral embolization. The particle size predominantly used was 100-300 µm (n = 441). PAE lead to significant (p < .001) reduction of both PV (-9.67 ± 14.52 mL) and PSA level (-2,65 ± 1.56 ng/mL) between pre- and three months after PAE. Substantial improvement were observed for IPSS (-9 points) and QoL scores (-2 points), with stable IIEF scores. Only minor complications (n = 16) were reported, and no major complications were observed. Between the first PAE in 2019 and the routinely performed PAE in 2023 significant (p < .0001) reductions in fluoroscopy (-25.2%), and procedural times (-26.1%) were observed. CONCLUSION: In conclusion, PAE is a safe and effective treatment for BPH, offering significant improvements in lower urinary tract symptoms (LUTS) and QoL while maintaining sexual function.

4.
Radiol Med ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38743319

RESUMEN

Dual-energy CT stands out as a robust and innovative imaging modality, which has shown impressive advancements and increasing applications in musculoskeletal imaging. It allows to obtain detailed images with novel insights that were once the exclusive prerogative of magnetic resonance imaging. Attenuation data obtained by using different energy spectra enable to provide unique information about tissue characterization in addition to the well-established strengths of CT in the evaluation of bony structures. To understand clearly the potential of this imaging modality, radiologists must be aware of the technical complexity of this imaging tool, the different ways to acquire images and the several algorithms that can be applied in daily clinical practice and for research. Concerning musculoskeletal imaging, dual-energy CT has gained more and more space for evaluating crystal arthropathy, bone marrow edema, and soft tissue structures, including tendons and ligaments. This article aims to analyze and discuss the role of dual-energy CT in musculoskeletal imaging, exploring technical aspects, applications and clinical implications and possible perspectives of this technique.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38762707

RESUMEN

An accurate diagnosis of venous thromboembolism (VTE) is crucial, given the potential for high mortality in undetected cases. Strategic D-dimer testing may aid in identifying low-risk patients, preventing overdiagnosis and reducing imaging costs. We conducted a retrospective, comparative analysis to assess the potential cost savings that could be achieved by adopting different approaches to determine the most effective D-dimer cut-off value in cancer patients with suspected VTE, compared to the commonly used rule-out cut-off level of 0.5 mg/L. The study included 526 patients (median age 65, IQR 55-75) with a confirmed cancer diagnosis who underwent D-dimer testing. Among these patients, the VTE prevalence was 29% (n = 152). Each diagnostic strategy's sensitivity, specificity, negative likelihood ratio (NLR), as well as positive likelihood ratio (PLR), and the proportion of patients exhibiting a negative D-dimer test result, were calculated. The diagnostic strategy that demonstrated the best balance between specificity, sensitivity, NLR, and PLR, utilized an inverse age-specific cut-off level for D-dimer [0.5 + (66-age) × 0.01 mg/L]. This method yielded a PLR of 2.9 at a very low NLR for the exclusion of VTE. We observed a significant cost reduction of 4.6% and 1.0% for PE and DVT, respectively. The utilization of an age-adjusted cut-off [patient's age × 0.01 mg/L] resulted in the highest cost savings, reaching 8.1% for PE and 3.4% for DVT. Using specified D-dimer cut-offs in the diagnosis of VTE could improve economics, considering the limited occurrence of confirmed cases among patients with suspected VTE.

6.
Diagnostics (Basel) ; 14(7)2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38611610

RESUMEN

(1) Background: Low bone mineral density (BMD) is a significant risk factor for complicated surgery and leads to the increased use of bone substitutes in patients with distal radius fractures (DRFs). No accepted model has yet been established to predict the use of bone substitutes to facilitate preoperative planning. (2) Methods: Unenhanced dual-energy CT (DECT) images of DRFs were retrospectively acquired between March 2016 and September 2020 using the internal PACS system. Available follow-up imaging and medical health records were reviewed to determine the use of bone substitutes. DECT-based BMD, trabecular Hounsfield units (HU), cortical HU, and cortical thickness ratio were measured in non-fractured segments of the distal radius. Diagnostic accuracy parameters were calculated for all metrics using receiver-operating characteristic (ROC) curves and associations of all metrics with the use of bone substitutes were evaluated using logistic regression models. (3) The final study population comprised 262 patients (median age 55 years [IQR 43-67 years]; 159 females, 103 males). According to logistic regression analysis, DECT-based BMD was the only metric significantly associated with the use of bone substitutes (odds ratio 0.96, p = 0.003). However, no significant associations were found for cortical HU (p = 0.06), trabecular HU (p = 0.33), or cortical thickness ratio (p = 0.21). ROC-curve analysis revealed that a combined model of all four metrics had the highest diagnostic accuracy with an area under the curve (AUC) of 0.76. (4) Conclusions: DECT-based BMD measurements performed better than HU-based measurements and cortical thickness ratio. The diagnostic performance of all four metrics combined was superior to that of the individual parameters.

7.
Diagnostics (Basel) ; 14(7)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38611654

RESUMEN

OBJECTIVES: The aim of this study is to evaluate the diagnostic accuracy of dual-energy computed tomography (DECT)-based Rho/Z maps in differentiating between metastases and benign liver lesions in patients diagnosed with malignant melanoma compared to conventional CT value measurements. METHODS: This retrospective study included 73 patients (mean age, 70 ± 13 years; 43 m/30 w) suffering from malignant melanoma who had undergone third-generation DECT as part of tumor staging between December 2017 and December 2021. For this study, we measured Rho (electron density) and Z (effective atomic number) values as well as Hounsfield units (HUs) in hypodense liver lesions. Values were compared, and diagnostic accuracy for differentiation was computed using receiver operating characteristic (ROC) curve analyses. Additional performed MRI or biopsies served as a standard of reference. RESULTS: A total of 136 lesions (51 metastases, 71 cysts, and 14 hemangiomas) in contrast-enhanced DECT images were evaluated. The most notable discrepancy (p < 0.001) between measured values and the highest diagnostic accuracy for distinguishing melanoma metastases from benign cysts was observed for the Z (0.992; 95% CI, 0.956-1) parameters, followed by Rho (0.908; 95% CI, 0.842-0.953) and finally HU120kV (0.829; 95% CI, 0.751-0.891). Conversely, when discriminating between liver metastases and hemangiomas, the HU120kV parameters showed the most significant difference (p < 0.001) and yielded the highest values for diagnostic accuracy (0.859; 95% CI, 0.740-0.937), followed by the Z parameters (0.790; 95% CI, 0.681-0.876) and finally the Rho values (0.621; 95% CI, 0.501-0.730). CONCLUSIONS: Rho and Z measurements derived from DECT allow for improved differentiation of liver metastases and benign liver cysts in patients with malignant melanoma compared to conventional CT value measurements. In contrast, in differentiation between liver hemangiomas and metastases, Rho/Z maps show inferior diagnostic accuracy. Therefore, differentiation between these two lesions remains a challenge for CT imaging.

8.
Emerg Radiol ; 31(3): 303-311, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38523224

RESUMEN

PURPOSE: Recent advancements in medical imaging have transformed diagnostic assessments, offering exciting possibilities for extracting biomarker-based information. This study aims to investigate the capabilities of a machine learning classifier that incorporates dual-energy computed tomography (DECT) radiomics. The primary focus is on discerning and predicting outcomes related to pulmonary embolism (PE). METHODS: The study included 131 participants who underwent pulmonary artery DECT angiography between January 2015 and March 2022. Among them, 104 patients received the final diagnosis of PE and 27 patients served as a control group. A total of 107 radiomic features were extracted for every case based on DECT imaging. The dataset was divided into training and test sets for model development and validation. Stepwise feature reduction identified the most relevant features, which were used to train a gradient-boosted tree model. Receiver operating characteristics analysis and Cox regression tests assessed the association of texture features with overall survival. RESULTS: The trained machine learning classifier achieved a classification accuracy of 0.94 for identifying patients with acute PE with an area under the receiver operating characteristic curve of 0.91. Radiomics features could be valuable for predicting outcomes in patients with PE, demonstrating strong prognostic capabilities in survival prediction (c-index, 0.991 [0.979-1.00], p = 0.0001) with a median follow-up of 130 days (IQR, 38-720). Notably, the inclusion of clinical or DECT parameters did not enhance predictive performance. CONCLUSION: In conclusion, our study underscores the promising potential of leveraging radiomics on DECT imaging for the identification of patients with acute PE and predicting their outcomes. This approach has the potential to improve clinical decision-making and patient management, offering efficiencies in time and resources by utilizing existing DECT imaging without the need for an additional scoring system.


Asunto(s)
Angiografía por Tomografía Computarizada , Aprendizaje Automático , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagen , Masculino , Femenino , Pronóstico , Persona de Mediana Edad , Angiografía por Tomografía Computarizada/métodos , Anciano , Biomarcadores/sangre , Valor Predictivo de las Pruebas , Estudios Retrospectivos
9.
Radiol Cardiothorac Imaging ; 6(2): e230096, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38546330

RESUMEN

Purpose To examine the clinical feasibility of workstation-based CT fractional flow reserve (CT-FFR) for coronary artery disease (CAD) evaluation during preprocedural planning in patients undergoing transcatheter aortic valve replacement (TAVR). Materials and Methods In this retrospective single-center study, 434 patients scheduled for TAVR between 2018 and 2020 were screened for study inclusion; a relevant proportion of patients (35.0% [152 of 434]) was not suitable for evaluation due to insufficient imaging properties. A total of 112 patients (mean age, 82.1 years ± 6.7 [SD]; 58 [52%] men) were included in the study. Invasive angiography findings, coronary CT angiography results, and Agatston score were acquired and compared with on-site CT-FFR computation for evaluation of CAD and prediction of major adverse cardiovascular events (MACE) within a 24-month follow-up. Results Hemodynamic relevant CAD, as suggested by CT-FFR of 0.80 or less, was found in 41 of 70 (59%) patients with stenosis of 50% or more. MACE occurred in 23 of 112 (20.5%) patients, from which 14 of 23 had stenoses with CT-FFR of 0.80 or less (hazard ratio [HR], 3.33; 95% CI: 1.56, 7.10; P = .002). CT-FFR remained a significant predictor of MACE after inclusion in a multivariable model with relevant covariables (HR, 2.89; 95% CI: 1.22, 6.86; P = .02). An Agatston score of 1000 Agatston units or more (HR, 2.25; 95% CI: 0.98, 5.21; P = .06) and stenoses of 50% or more determined via invasive angiography (HR, 0.94; 95% CI: 0.41, 2.17; P = .88) were not significant predictors of MACE. Conclusion Compared with conventional CAD markers, CT-FFR better predicted adverse outcomes after TAVR. A relevant portion of the screened cohort, however, was not suitable for CT-based CAD evaluation. Keywords: CT, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Coronary Arteries, Outcomes Analysis © RSNA, 2024 See also the commentary by Weir-McCall and Pugliese in this issue.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Constricción Patológica , Estudios Retrospectivos , Angiografía Coronaria
10.
Acad Radiol ; 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38461052

RESUMEN

RATIONALE AND OBJECTIVES: Bone non-union is a serious complication of distal radius fractures (DRF) that can result in functional limitations and persistent pain. However, no accepted method has been established to identify patients at risk of developing bone non-union yet. This study aimed to compare various CT-derived metrics for bone mineral density (BMD) assessment to identify predictive values for the development of bone non-union. MATERIALS AND METHODS: CT images of 192 patients with DRFs who underwent unenhanced dual-energy CT (DECT) of the distal radius between 03/2016 and 12/2020 were retrospectively identified. Available follow-up imaging and medical health records were evaluated to determine the occurrence of bone non-union. DECT-based BMD, trabecular Hounsfield unit (HU), cortical HU and cortical thickness ratio were measured in normalized non-fractured segments of the distal radius. RESULTS: Patients who developed bone non-union were significantly older (median age 72 years vs. 54 years) and had a significantly lower DECT-based BMD (median 68.1 mg/cm3 vs. 94.6 mg/cm3, p < 0.001). Other metrics (cortical thickness ratio, cortical HU, trabecular HU) showed no significant differences. ROC and PR curve analyses confirmed the highest diagnostic accuracy for DECT-based BMD with an area under the curve (AUC) of 0.83 for the ROC curve and an AUC of 0.46 for the PR curve. In logistic regression models, DECT-based BMD was the sole metric significantly associated with bone non-union. CONCLUSION: DECT-derived metrics can accurately predict bone non-union in patients who sustained DRF. The diagnostic performance of DECT-based BMD is superior to that of HU-based metrics and cortical thickness ratio.

11.
Acad Radiol ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38519304

RESUMEN

RATIONALE AND OBJECTIVES: Lumbar disk degeneration is a common condition contributing significantly to back pain. The objective of the study was to evaluate the potential of dual-energy CT (DECT)-derived collagen maps for the assessment of lumbar disk degeneration. PATIENTS AND METHODS: We conducted a retrospective analysis of 127 patients who underwent dual-source DECT and MRI of the lumbar spine between 07/2019 and 10/2022. The level of lumbar disk degeneration was categorized by three radiologists as follows: no/mild (Pfirrmann 1&2), moderate (Pfirrmann 3&4), and severe (Pfirrmann 5). Recall (sensitivity) and accuracy of DECT collagen maps were calculated. Intraclass correlation coefficient (ICC) was used to evaluate inter-reader reliability. Subjective evaluations were performed using 5-point Likert scales for diagnostic confidence and image quality. RESULTS: We evaluated a total of 762 intervertebral disks from 127 patients (median age, 69.7 (range, 23.0-93.7), female, 56). MRI identified 230 non/mildly degenerated disks (30.2%), 484 moderately degenerated disks (63.5%), and 48 severely degenerated disks (6.3%). DECT collagen maps yielded an overall accuracy of 85.5% (1955/2286). Recall (sensitivity) was 79.3% (547/690) for the detection of no/mild lumbar disk degeneration, 88.7% (1288/1452) for the detection of moderate disk degeneration, and 83.3% (120/144) for the detection of severe disk degeneration (ICC=0.9). Subjective evaluations of DECT collagen maps showed high diagnostic confidence (median 4) and good image quality (median 4). CONCLUSION: The use of DECT collagen maps to distinguish different stages of lumbar disk degeneration may have clinical significance in the early diagnosis of disk-related pathologies in patients with contraindications for MRI or in cases of unavailability of MRI.

12.
Rofo ; 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38479409

RESUMEN

PURPOSE: Due to the increasing number of COVID-19 infections since spring 2020 the patient care workflow underwent changes in Germany. To minimize face-to-face exposure and reduce infection risk, non-time-critical elective medical procedures were postponed. Since ultrasound examinations include non-time-critical elective examinations and often can be substituted by other imaging modalities not requiring direct patient contact, the number of examinations has declined significantly. The aim of this study is to quantify the baseline number of ultrasound examinations in the years before, during, and in the early post-pandemic period of the COVID-19 pandemic (since January 2015 to September 2023), and to measure the number of examinations at different German university hospitals. MATERIALS AND METHODS: The number of examinations was assessed based on a web-based database at all participating clinics at the indicated time points. RESULTS: N = 288 562 sonographic examinations from four sites were included in the present investigation. From January 2020 to June 2020, a significantly lower number of examinations of n = 591.21 vs. 698.43 (p = 0.01) per month and included center was performed. Also, excluding the initial pandemic period until June 2020, significantly fewer ultrasound examinations were performed compared to pre-pandemic years 648.1 vs. 698.4 (p < 0.05), per month and included center, while here differences between the individual centers were observed. In the late phase of the pandemic (n = 681.96) and in the post-pandemic phase (as defined by the WHO criteria from May 2023; n = 739.95), the number of sonographic examinations returned to pre-pandemic levels. CONCLUSION: The decline in the number of sonographic examinations caused by the COVID-19 pandemic was initially largely intentional and can be illustrated quantitatively. After an initial abrupt decline in sonographic examinations, the pre-pandemic levels could not be reached for a long time, which could be due to restructuring of patient care and follow-up treatment. In the post-pandemic phase, the pre-pandemic level has been achieved again. The reasons for a prolonged reduction in ultrasound examinations are discussed in this article. KEY POINTS: · During the pandemic, significantly fewer ultrasound examinations were performed in the included centers.. · The number of examinations could not be reach the pre-pandemic level for a long time, which could be due to restructuring of patient care and follow-up treatment.. · Identifying causes for sonographic exam reduction is crucial in pandemic preparedness to uphold healthcare quality and continuity for all patients.. · The prolonged decline in sonographic examinations during the pandemic does not represent a lasting trend, as evidenced by the return to pre-pandemic levels..

13.
Diagnostics (Basel) ; 14(5)2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38472939

RESUMEN

PURPOSE: To evaluate the diagnostic performance of a dual-energy computed tomography (DECT)-based material decomposition algorithm for iodine quantification and fat fraction analysis to detect lymph node metastases in breast cancer patients. MATERIALS AND METHODS: 30 female patients (mean age, 63.12 ± 14.2 years) diagnosed with breast cancer who underwent pre-operative chest DECT were included. To establish a reference standard, the study correlated histologic repots after lymphadenectomy or confirming metastasis in previous/follow-up examinations. Iodine concentration and fat fraction were determined through region-of-interest measurements on venous DECT iodine maps. Receiver operating characteristic curve analysis was conducted to identify the optimal threshold for differentiating between metastatic and non-metastatic lymph nodes. RESULTS: A total of 168 lymph nodes were evaluated, divided into axillary (metastatic: 46, normal: 101) and intramammary (metastatic: 10, normal: 11). DECT-based fat fraction values exhibited significant differences between metastatic (9.56 ± 6.20%) and non-metastatic lymph nodes (41.52 ± 19.97%) (p < 0.0001). Absolute iodine concentrations showed no significant differences (2.25 ± 0.97 mg/mL vs. 2.08 ± 0.97 mg/mL) (p = 0.7999). The optimal fat fraction threshold for diagnosing metastatic lymph nodes was determined to be 17.75%, offering a sensitivity of 98% and a specificity of 94%. CONCLUSIONS: DECT fat fraction analysis emerges as a promising method for identifying metastatic lymph nodes, overcoming the morpho-volumetric limitations of conventional CT regarding lymph node assessment. This innovative approach holds potential for improving pre-operative lymph node evaluation in breast cancer patients, offering enhanced diagnostic accuracy.

14.
Diagnostics (Basel) ; 14(5)2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38472968

RESUMEN

BACKGROUND: Despite a considerable amount of literature on dual-energy CT (DECT) iodine uptake of the head and neck, the physiologic iodine uptake of this region has not been defined yet. This study aims to establish reference values for the iodine uptake of healthy organs to facilitate clinical application. METHODS: Consecutive venous DECT scans of the head and neck were reviewed, and unremarkable exams were included (n = 617). A total of 35 region of interest measurements were performed in 16 anatomical regions. Iodine uptake was compared among different organs/tissues and subgroup analysis was performed (male (n = 403) vs. female (n = 214); young (n = 207) vs. middle-aged (n = 206) vs. old (n = 204); and normal weight (n = 314) vs. overweight (n = 196) vs. obese (n = 107)). RESULTS: Overall mean iodine uptake values ranged between 0.5 and 9.4 mg/mL. Women showed higher iodine concentrations in the cervical vessels and higher uptake for the parotid gland, masseter muscle, submandibular glands, sublingual glands, palatine tonsils, tongue body, thyroid gland, and the sternocleidomastoid muscle than men (p ≤ 0.04). With increasing age, intravascular iodine concentrations increased as well as iodine uptake for cerebellum and thyroid gland, while values for the tongue and palatine tonsils were lower compared to younger subjects (p ≤ 0.03). Iodine concentrations for parotid glands and sternocleidomastoid muscles decreased with a higher BMI (p ≤ 0.004), while normal-weighted patients showed higher iodine values inside the jugular veins, other cervical glands, and tonsils versus patients with a higher BMI (p ≤ 0.04). CONCLUSION: physiologic iodine uptake values of cervical organs and tissues show gender-, age-, and BMI-related differences, which should be considered in the clinical routine of head and neck DECT.

15.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38535045

RESUMEN

OBJECTIVES: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections. METHODS: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV. The corrected artifact burden, corrected image noise and artifact index were calculated. We also assessed subjective image quality on a Likert-scale. RESULTS: Our study showed a lower artifact burden and less noise in artifact-affected areas above the energy levels of 70 keV for hyperattenuation artifacts (conventional polychromatic CT images 1123 ± 625 HU vs. 70 keV VME 1089 ± 733 HU, p = 0.125) and above of 80 keV for hypoattenuation artifacts (conventional CT images -1166 ± 779 HU vs. 80 keV VME -1170 ± 851 HU, p = 0.927). Vascular structures were less hampered by metal artifacts than muscles (e.g., corrected artifact burden at 40 keV muscle 158 ± 125 HU vs. vessels -63 ± 158 HU p < 0.001), which was also reflected in the subjective image assessment, which showed better ratings at higher keV values and overall better ratings for vascular structures than for the overall artifact burden. CONCLUSIONS: Our research suggests 70 keV might be the best compromise for reducing metal artifacts affecting vascular structures and preventing vascular contrast if solely using VME reconstructions. VME imaging shows only significant effects on the general artifact burden. Vascular structures generally experience fewer metal artifacts than soft tissue due to their greater distance from the teeth, which are a common source of such artifacts.

17.
Acad Radiol ; 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38242733

RESUMEN

BACKGROUND: The advent of advanced computed tomography (CT) technology and the field of radiomics has opened up new avenues in diagnostic assessments. Increasingly, there is substantial evidence advocating for the incorporation of quantitative imaging biomarkers in the clinical decision-making process. This study aimed to examine the correlation between D-dimer levels and thrombus size in acute pulmonary embolism (PE) combining dual-energy CT (DECT) and radiomics and to investigate the diagnostic utility of a machine learning classifier based on dual-energy computed tomography (DECT) radiomics for identifying patients with a complicated course, defined as at least hospitalization at IMC. METHODS: The study was conducted including 136 participants who underwent pulmonary artery CT angiography from January 2015 to March 2022. Based on DECT imaging, 107 radiomic features were extracted for each patient using standardized image processing. After dividing the dataset into training and test sets, stepwise feature reduction based on reproducibility, variable importance and correlation analyses were performed to select the most relevant features; these were used to train and validate the gradient-boosted tree models.Receiver operating characteristics (ROC) analysis was utilized to evaluate the association between volumetric, laboratory data and adverse outcomes. RESULTS: In the central PE group, we observed a significant correlation between thrombus volumetrics and D-dimer levels (p = 0.0037), as well as between thrombus volumetrics and hospitalization at the Intermediate Care Unit (IMC) (p = 0.0001). In contrast, no statistically significant differences were identified in thrombus sizes between patients who experienced complications and those who had a favorable course (p = 0.3162). The trained machine learning classifier achieved an accuracy of 61% and 55% in identifying patients with a complicated course, as indicated by an area under the ROC curve of 0.63 and 0.58. CONCLUSION: In conclusion, our findings indicate a positive correlation between D-dimer levels and central PE's pulmonary embolic burden. Thrombus volumetrics may serve as an indicator for complications and outcomes in acute PE patients. Thus, thrombus volumetrics, as opposed to D-dimers, could be an additional marker for evaluating embolic disease severity. Moreover, DECT-derived radiomic feature models show promise in identifying patients with a complicated course, such as hospitalization at IMC.

18.
Diagnostics (Basel) ; 14(2)2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38248018

RESUMEN

This Special Issue of Diagnostics entitled "Leading Diagnosis on Chest Imaging" provides an overview of recent technical developments in chest imaging and their clinical relevance, with a special focus on dual-energy CT (DECT) imaging [...].

19.
Eur J Radiol ; 171: 111283, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38183896

RESUMEN

BACKGROUND: Dual-energy CT (DECT)-derived bone mineral density (BMD) of the distal radius and other CT-derived metrics related to bone health have been suggested for opportunistic osteoporosis screening and risk evaluation for sustaining distal radius fractures (DRFs). METHODS: The distal radius of patients who underwent DECT between 01/2016 and 08/2021 was retrospectively analyzed. Cortical Hounsfield Unit (HU), trabecular HU, cortical thickness, and DECT-based BMD were acquired from a non-fractured, metaphyseal area in all examinations. Receiver-operating characteristic (ROC) analysis was conducted to determine the area under the curve (AUC) values for predicting DRFs based on DECT-derived BMD, HU values, and cortical thickness. Logistic regression models were then employed to assess the associations of these parameters with the occurrence of DRFs. RESULTS: In this study, 263 patients (median age: 52 years; interquartile range: 36-64; 132 women; 192 fractures) were included. ROC curve analysis revealed a higher area under the curve (AUC) value for DECT-derived BMD compared to cortical HU, trabecular HU, and cortical thickness (0.91 vs. 0.61, 0.64, and 0.69, respectively; p <.001). Logistic regression models confirmed the association between lower DECT-derived BMD and the occurrence of DRFs (Odds Ratio, 0.83; p <.001); however, no influence was observed for cortical HU, trabecular HU, or cortical thickness. CONCLUSIONS: DECT can be used to assess the BMD of the distal radius without dedicated equipment such as calibration phantoms to increase the detection rates of osteoporosis and stratify the individual risk to sustain DRFs. In contrast, assessing HU-based values and cortical thickness does not provide clinical benefit.


Asunto(s)
Fracturas Óseas , Osteoporosis , Humanos , Femenino , Persona de Mediana Edad , Radio (Anatomía) , Absorciometría de Fotón , Estudios Retrospectivos , Osteoporosis/diagnóstico por imagen , Densidad Ósea , Tomografía Computarizada por Rayos X , Medición de Riesgo
20.
Eur J Clin Invest ; 54(4): e14139, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38063028

RESUMEN

BACKGROUND: Technological progress in the acquisition of medical images and the extraction of underlying quantitative imaging data has introduced exciting prospects for the diagnostic assessment of a wide range of conditions. This study aims to investigate the diagnostic utility of a machine learning classifier based on dual-energy computed tomography (DECT) radiomics for classifying pulmonary embolism (PE) severity and assessing the risk for early death. METHODS: Patients who underwent CT pulmonary angiogram (CTPA) between January 2015 and March 2022 were considered for inclusion in this study. Based on DECT imaging, 107 radiomic features were extracted for each patient using standardized image processing. After dividing the dataset into training and test sets, stepwise feature reduction based on reproducibility, variable importance and correlation analyses were performed to select the most relevant features; these were used to train and validate the gradient-boosted tree models. RESULTS: The trained machine learning classifier achieved a classification accuracy of .90 for identifying high-risk PE patients with an area under the receiver operating characteristic curve of .59. This CT-based radiomics signature showed good diagnostic accuracy for risk stratification in individuals presenting with central PE, particularly within higher risk groups. CONCLUSION: Models utilizing DECT-derived radiomics features can accurately stratify patients with pulmonary embolism into established clinical risk scores. This approach holds the potential to enhance patient management and optimize patient flow by assisting in the clinical decision-making process. It also offers the advantage of saving time and resources by leveraging existing imaging to eliminate the necessity for manual clinical scoring.


Asunto(s)
Embolia Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Radiómica , Reproducibilidad de los Resultados , Embolia Pulmonar/diagnóstico por imagen , Medición de Riesgo , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA