Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Appl Oral Sci ; 30: e20220227, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36753069

RESUMEN

BACKGROUND: To evaluate the release of bisphenol-A glycidyl methacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA), bisphenol A (BPA), and phthalates of the composite resin used in the bonding of spurs applied in the treatment of children with anterior open bite and its effects on human keratinocytes. METHODOLOGY: Saliva samples of 22 children were collected before spur attachment (baseline) and 30 minutes (min) and 24 hours (h) after spur bonding. Analysis was performed using high-performance liquid chromatography (HPLC) coupled to tandem mass spectrometry (HPLC-MS/MS) and gas chromatography coupled to mass spectrometry (GC-MS). Standardized resin increments were added to three different dilutions of the cell culture medium. Keratinocytes (HaCaT) were cultivated in the conditioned media and evaluated for cell viability (MTT) and cell scratch assay. RESULTS: The levels of BisGMA (1.74±0.27 µg/mL), TEGDMA (2.29±0.36 µg/mL), and BPA (3.264±0.88 µg/L) in the saliva after 30 min, in comparison to baseline (0±0 µg/mL, 0±0 µg/mL, and 1.15±0.21 µg/L, respectively), presented higher numbers. After 24 h, the levels of the monomers were similar to the baseline. Phthalates showed no significant difference among groups. HaCat cells showed increased viability and reduced cell migration over time after exposure to methacrylate-based resin composites. CONCLUSION: Resin composites, used to attach spurs in children with anterior open bite during orthodontic treatment, release monomers after polymerization and can influence the behavior of human keratinocytes, even at very low concentrations. Orthodontists should be aware of the risks of the resinous compounds release and preventive procedures should be held to reduce patient exposure.


Asunto(s)
Mordida Abierta , Saliva , Niño , Humanos , Saliva/química , Espectrometría de Masas en Tándem , Ácidos Polimetacrílicos/química , Resinas Compuestas/química , Bisfenol A Glicidil Metacrilato/química , Metacrilatos/química , Polietilenglicoles/química , Ensayo de Materiales
2.
J. appl. oral sci ; 30: e20220227, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1421892

RESUMEN

Abstract To evaluate the release of bisphenol-A glycidyl methacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA), bisphenol A (BPA), and phthalates of the composite resin used in the bonding of spurs applied in the treatment of children with anterior open bite and its effects on human keratinocytes. Methodology Saliva samples of 22 children were collected before spur attachment (baseline) and 30 minutes (min) and 24 hours (h) after spur bonding. Analysis was performed using high-performance liquid chromatography (HPLC) coupled to tandem mass spectrometry (HPLC-MS/MS) and gas chromatography coupled to mass spectrometry (GC-MS). Standardized resin increments were added to three different dilutions of the cell culture medium. Keratinocytes (HaCaT) were cultivated in the conditioned media and evaluated for cell viability (MTT) and cell scratch assay. Results The levels of BisGMA (1.74±0.27 μg/mL), TEGDMA (2.29±0.36 μg/mL), and BPA (3.264±0.88 μg/L) in the saliva after 30 min, in comparison to baseline (0±0 μg/mL, 0±0 μg/mL, and 1.15±0.21 μg/L, respectively), presented higher numbers. After 24 h, the levels of the monomers were similar to the baseline. Phthalates showed no significant difference among groups. HaCat cells showed increased viability and reduced cell migration over time after exposure to methacrylate-based resin composites. Conclusion Resin composites, used to attach spurs in children with anterior open bite during orthodontic treatment, release monomers after polymerization and can influence the behavior of human keratinocytes, even at very low concentrations. Orthodontists should be aware of the risks of the resinous compounds release and preventive procedures should be held to reduce patient exposure.

3.
Food Chem ; 362: 129902, 2021 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-34175690

RESUMEN

This paper describes a fast, sensitive, environment-friendly method for the determination of 19 primary aromatic amines (PAAs) in cooking utensils by capillary zone electrophoresis coupled with tandem mass spectrometry. The best electrophoretic separation of PAAs was obtained in 0.1 mol l-1 formic acid (pH 2.4) as the background electrolyte, fused silica capillary (67 cm) with a run time below 6 min. The proposed method presented a linear calibration with correlation coefficients higher than 0.99 and reproducibility in a range of 1-25%. Limits of detection were in the range of 0.2-1.3 µg kg-1 and recoveries were in a range of 85-120% for all the PAAs. The validated method was employed to determine PAAs on 36 samples of cooking utensils using acetic simulant. The results showed that 4,4'-diaminodiphenylmethane and aniline being the most frequently found PAAs in these samples and 28% of cooking utensils were not compliant.


Asunto(s)
Aminas/análisis , Utensilios de Comida y Culinaria , Electroforesis Capilar , Espectrometría de Masas en Tándem , Compuestos de Anilina/análisis , Calibración , Electroforesis Capilar/métodos , Reproducibilidad de los Resultados
4.
Environ Sci Pollut Res Int ; 28(29): 39026-39034, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33742384

RESUMEN

The demand for healthier foods with high nutritional value has resulted in intensive fish farming. In this production system, high-frequency infections occur, and antibiotics are administrated for control. Only two antibiotics are allowed for use in Brazilian aquaculture, one of which is florfenicol. In this work, a bioconcentration assay was performed to assess the accumulation of florfenicol in the muscle of Nile tilapia (Oreochromis niloticus). Tilapia was evaluated as it is the most produced fish species in Brazil. The fish were exposed to florfenicol at a nominal concentration of 10 mg/L, through the water. Muscle and water were collected at 0, 1.5, 3, 6, 24, and 48 h during the exposure phase and at 1.5, 3, 6, 24, 48, and 120 h during the depuration phase. Quantification was performed using an LC-MS/MS. The results showed rapid absorption and elimination of the antibiotic (half-life, t1/2 = 5 h), with low potential for accumulation of florfenicol in tilapia muscles. The study was performed to determine the bioconcentration factor (BCF) and withdrawal period of florfenicol, being 0.05 mL/µg and 1.8 h, respectively. The results contribute to set protocols for the safe use of florfenicol in tilapia transport, avoiding residues in fish that may pose risks to human health.


Asunto(s)
Cíclidos , Tilapia , Animales , Antibacterianos , Bioacumulación , Brasil , Cromatografía Liquida , Humanos , Espectrometría de Masas en Tándem , Tianfenicol/análogos & derivados , Agua
5.
Braz. J. Pharm. Sci. (Online) ; 56: e17691, 2020. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1089208

RESUMEN

The present study aimed at the evaluation of Passiflora coccinea (Aubl.) antioxidant and photo protective in vitro activities, looking forward to their application as antiaging or sunscreen agents in cosmetic formulations. Methanolic and glycolic leaf extracts were prepared by three methods: ultrasound assisted extraction (UAE, 30 min.), maceration at room temperature (72 h) and maceration at 30 ºC (72 h). The antioxidant activities of the extracts were measured by DPPH and ORAC-FL assays and they were incorporated into a cosmetic emulsion to have their sun protection factor (SPF) measured spectrophotometricaly. The antioxidant activity of the emulsions were measured by DPPH and ORAC as well. C-glycosyl-flavones were identified in the extracts by ESI-MS/MS, in comparision with standards. The UAE methanolic extract and the maceration at 30 ºC glycolic extract were submmited to HPLC-DAD analysis and isovitexin was quantifyed in both by a validated method. The methanolic extract antioxidant activity was independent of the extraction method, higher than reported for other species of Passiflora and detectable when incorporated into the emulsion formulation. Maceration at 30oC was the most suitable method for glycolic extraction and its antioxidant activity was lower than the value presented by the methanolic extracts. None of the extracts exhibited a SPF value. Isovitexin in the UAE methanolic extract was 12.67 times higher than the most active glycolic extract, aside of their similar chromatographic profiles. Although a SPF value was not detected, the results indicate that P. coccinea can be a potential new source of antioxidants for topical antiaging formulations.

6.
Food Res Int ; 123: 189-197, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31284967

RESUMEN

Coconut oil (CO) from fifteen different varieties of coconuts (Cocos nucifera L.) and one CO processed on an industrial scale were analyzed by electrospray ionization mass spectrometry (ESI-MS) and the data processed using the chemometric tools principal component analysis and independent component analysis. ESI-MS fingerprinting of lipid compounds showed predominance of diacylglycerols and triacylglycerols, as confirmed by high-resolution MS measurements. Chemometric processing of the ESI-MS data differentiated the coconut oil samples, showing that different coconut varieties/cultivars produce oils with distinguishable abundances of lipidic compounds. Thus ESI-MS analysis followed by data treatment using chemometric tools offers a tool able to classify the industrial coconut oils in a fast, simple and effective way, as well as serving as a potential method to identify the coconut varieties by the CO origin, and the occurrence of any adulteration. The procedure may also be applied for quality control of the industrial processes.


Asunto(s)
Cocos/química , Análisis de Componente Principal , Espectrometría de Masa por Ionización de Electrospray , Aceite de Coco , Diglicéridos/análisis , Análisis de los Alimentos , Triglicéridos/análisis
7.
J Chromatogr A ; 1602: 217-227, 2019 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-31133424

RESUMEN

The aim of this paper is to develop and validate a methodology with potential for routine analysis that allows a fast and easy quantification of 19 primary aromatic amines (PAAs) in acid simulant (3% (w/v) acetic acid aqueous) in food contact materials (FCM). The main reason for studying these amines was the fact that some of them have a carcinogenic factor according to toxicological studies. To validate the method, the parameters linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy using an UPLC-MS/MS were evaluated. This study also analyzed 36 samples of kitchenware obtained from retail markets: 16 were made of polyamide (PA), one was made of polypropylene (PP) and 19 were made of silicone. The origins of samples were Brazil, China and Turkey. Eleven samples had levels of 4,4´-diaminodiphenylmethane higher than permitted by legislation and five samples showed values of aniline above the limit. Considering the Mood test for polyamides, there were significant differences between the samples from Brazil and China, as well as between the colors in the silicone samples. Regarding the polyamides, the Chinese samples showed higher amounts of PAAs than the Brazilian ones, being above that allowed by legislation. Three Chinese silicone samples presented values above the legislation limit. These were all from the same importer.


Asunto(s)
Aminas/análisis , Técnicas de Química Analítica/métodos , Cromatografía Liquida , Utensilios de Comida y Culinaria/normas , Contaminación de Alimentos/análisis , Espectrometría de Masas en Tándem , Compuestos de Anilina/análisis , Brasil , Carcinógenos/análisis , China , Contaminación de Alimentos/prevención & control , Límite de Detección , Nylons/química , Polipropilenos/química
8.
Artículo en Inglés | MEDLINE | ID: mdl-27825628

RESUMEN

Molecularly imprinted polymers (MIP) are stable polymers with molecular recognition abilities, provided by the presence of a template during their synthesis, and are excellent materials with high selectivity for sample preparation in bioanalytical methods. This short review discusses aspects of MIP preparation and its applications as a sorbent material in pharmaceutical and biomedical analysis. MIP in different extraction configurations, including classical solid-phase extraction, solid-phase microextraction, magnetic molecularly imprinted solid-phase extraction, microextraction by packed sorbent and solid-phase extraction in pipette tips, are used to illustrate the good performance of this type of sorbent for sample preparation procedures of complex matrices, especially prior to bioanalytical approaches.


Asunto(s)
Biomarcadores/análisis , Impresión Molecular , Extracción en Fase Sólida , Impresión Molecular/instrumentación , Impresión Molecular/métodos , Extracción en Fase Sólida/instrumentación , Extracción en Fase Sólida/métodos
9.
Food Chem ; 213: 616-624, 2016 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-27451226

RESUMEN

The use of pesticides is directly linked to improvements in productivity and to the preservation of coconut palms. However pesticide analysis is necessary to determine whether pesticide residues in the food products containing coconut are within the maximum residue limits (MRLs), ensuring the quality of these products. This work aimed to develop a method for multiresidue determination of ten pesticides in coconut water and pulp using QuEChERS and LC-MS/MS. The method was effective in terms of selectivity, linearity, matrix effect, accuracy and precision, providing LOD of 3µgkg(-1), LOQ of 10µgkg(-1) and recoveries between 70 and 120% with RSD lower than 20%. The developed method was applied to 36 samples in which residues of carbendazim, carbofuran, cyproconazole and thiabendazole were found below the LOQ in coconut water and pulp.


Asunto(s)
Cromatografía Liquida/métodos , Cocos/química , Plaguicidas/química , Espectrometría de Masas en Tándem/métodos , Agua/química , Plaguicidas/análisis , Agua/análisis
10.
J Appl Oral Sci ; 20(4): 444-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23032206

RESUMEN

OBJECTIVE: To detect the presence and concentration of methylparaben in cartridges of commercial Brazilian local anesthetics. MATERIAL AND METHODS: Twelve commercial brands (4 in glass and 8 in plastic cartridges) of local anesthetic solutions for use in dentistry were purchased from the Brazilian market and analyzed. Different lots of the commercial brands were obtained in different Brazilian cities (Piracicaba, Campinas and São Paulo). Separation was performed using high performance liquid chromatography (HPLC) with UV-Vis detector. The mobile phase used was acetonitrile:water (75:25 - v/v), pH 4.5, adjusted with acetic acid at a flow rate of 1.0 ml.min-1. RESULTS: When detected in the solutions, the methylparaben concentration ranged from 0.01% (m/v) to 0.16% (m/v). One glass and all plastic cartridges presented methylparaben. CONCLUSION: 1. Methylparaben concentration varied among solutions from different manufacturers, and it was not indicated in the drug package inserts; 2. Since the presence of methylparaben in dental anesthetics is not regulated by the Brazilian National Health Surveillance Agency (ANVISA) and this substance could cause allergic reactions, it is important to alert dentists about its possible presence.


Asunto(s)
Anestésicos Locales/química , Parabenos/análisis , Conservadores Farmacéuticos/análisis , Ácido Acético/química , Acetonitrilos/química , Brasil , Hipersensibilidad a las Drogas/etiología , Humanos , Indicadores y Reactivos/química , Soluciones/química , Factores de Tiempo
11.
J. appl. oral sci ; 20(4): 444-448, July-Aug. 2012. ilus
Artículo en Inglés | LILACS | ID: lil-650621

RESUMEN

OBJECTIVE: To detect the presence and concentration of methylparaben in cartridges of commercial Brazilian local anesthetics. MATERIAL AND METHODS: Twelve commercial brands (4 in glass and 8 in plastic cartridges) of local anesthetic solutions for use in dentistry were purchased from the Brazilian market and analyzed. Different lots of the commercial brands were obtained in different Brazilian cities (Piracicaba, Campinas and São Paulo). Separation was performed using high performance liquid chromatography (HPLC) with UV-Vis detector. The mobile phase used was acetonitrile:water (75:25 - v/v), pH 4.5, adjusted with acetic acid at a flow rate of 1.0 ml.min-1. RESULTS: When detected in the solutions, the methylparaben concentration ranged from 0.01% (m/v) to 0.16% (m/v). One glass and all plastic cartridges presented methylparaben. CONCLUSION: 1. Methylparaben concentration varied among solutions from different manufacturers, and it was not indicated in the drug package inserts; 2. Since the presence of methylparaben in dental anesthetics is not regulated by the Brazilian National Health Surveillance Agency (ANVISA) and this substance could cause allergic reactions, it is important to alert dentists about its possible presence.


Asunto(s)
Humanos , Anestésicos Locales/química , Parabenos/análisis , Conservadores Farmacéuticos/análisis , Ácido Acético/química , Acetonitrilos/química , Brasil , Hipersensibilidad a las Drogas/etiología , Indicadores y Reactivos/química , Soluciones/química , Factores de Tiempo
12.
Braz. j. pharm. sci ; 47(4): 779-785, Oct.-Dec. 2011. graf, tab
Artículo en Inglés | LILACS | ID: lil-618071

RESUMEN

Parabens, common food preservatives, were analysed by capillary electrochromatography, using a commercial C18 silica (3 µm, 40 cm × 100 µm i. d.) capillary column as separation phase. In order to optimise the separation of these preservatives, the effects of mobile phase composition on the separation were evaluated, as well as the applied voltage and injection conditions. The retention behavior of these analytes was strongly influenced by the level of acetonitrile in the mobile phase. An optimal separation of the parabens was obtained within 18.5 minutes with a pH 8.0 mobile phase composed of 50:50 v/v tris(hydroxymethyl)aminomethane buffer and acetonitrile. The method was successfully applied to the quantitative analysis of paraben preservatives in sweetener samples with direct injection.


Os parabenos, empregados como conservantes em alimentos, foram analisados por eletrocromatografia capilar, empregando uma coluna comercial recheada com partículas de sílica-C18 (3 µm, 40 cm × 100 µm d. i.) como fase estacionária de separação. Para otimizar a separação destes conservantes foram avaliados os efeitos da composição da fase móvel na separação, bem como a voltagem e as condições de injeção. O comportamento de retenção dos analitos foi fortemente influenciado pela proporção de acetonitrila na fase móvel. A separação dos parabenos foi alcançada em 18,5 min com uma fase móvel contendo tampão tris(hidroximetil)aminometano e acetonitrila na proporção 50:50 v/v. O método foi aplicado na análise quantitativa de parabenos em adoçantes empregando a injeção direta das amostras.


Asunto(s)
Parabenos/análisis , Electrocromatografía Capilar/métodos , Edulcorantes/farmacocinética , /análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA