1.
Sci Rep ; 14(1): 10409, 2024 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-38710782

RESUMEN

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X , Aorta/diagnóstico por imagen , Aorta/cirugía , Resultado del Tratamiento , Prótesis Valvulares Cardíacas , Estudios Retrospectivos
2.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599692

RESUMEN

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Estudios de Seguimiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos
3.
Cardiovasc Revasc Med ; 55: 22-27, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37076413

RESUMEN

BACKGROUND: TAVR is an established treatment for patients with severe symptomatic aortic stenosis. Different THV platforms are nowadays available, each of them with its inherent limitations and others are under development aiming at overcoming such limitations. We thus sought to investigate the performance and 1-year clinical outcome of a new generation, balloon expandable, THV: the Myval™ (Meril Life Sciences Pvt. Ltd., Vapi, Gujarat, India). METHODS: This registry included the first 100 consecutive patients (mean age 80.7 ± 7.7; STS 4.3 ± 3.3 %), who underwent transcatheter aortic valve implantation for severe stenosis of the native aortic valve from May 2020 to December 2020, in two Italian Centers. Clinical and procedural outcomes were defined according to VARC-3 criteria. RESULTS: Transfemoral Myval THV was successfully implanted in all patients, with no intra-hospital mortality (technical success 100 %): vascular access complications were all "minor" (16 %), and managed by compression/balloon inflation; no cases of annular rupture or coronary obstruction occurred; 5 % of patients required an in-hospital pacemaker implantation (PM). Device success was 99 %. Overall and cardiovascular mortality were 6 % (CI 5 %-7 %) and 4 % (CI 2 %-5 %) at 1- year, while 12 % (CI 9 %-14 %) and 7 % (6-9 %) at 2 years. A total of 9 % of the patients required a PM within 12 months, and no further PM implantation occurred afterwards. No cerebrovascular events, renal failure and myocardial infarction occurred between discharge and 2-year follow-up. No events of structural valve deterioration but a sustained improvement of echocardiographic parameters were observed. CONCLUSION: The Myval THV has a promising safety/efficacy profile at 2 year follow up. This performance should be further evaluated in the context of randomized trials to better elucidate its potential.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Sistema de Registros , Diseño de Prótesis
4.
Front Cardiovasc Med ; 9: 931207, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35966561

RESUMEN

Background: A severe prosthesis-patient mismatch (PPM) is associated with adverse outcomes following transcatheter aortic valve replacement (TAVR) for de novo aortic stenosis or a failed surgical bioprosthesis. The impact of severe PPM in patients undergoing TAV-in-TAVR is unknown. Aim: We sought to investigate the incidence and 1-year outcomes of different grades of PPM in patients undergoing TAV-in-TAVR. Materials and methods: The TRANSIT-PPM is an international registry, including cases of degenerated TAVR treated with a second TAVR. PPM severity, as well as in-hospital, 30-day, and 1-year outcomes were defined according to the Valve Academic Research Consortium-3 (VARC-3) criteria. Results: Among 28 centers, 155 patients were included. Severe PPM was found in 6.5% of patients, whereas moderate PPM was found in 14.2% of patients. The rate of severe PPM was higher in patients who underwent TAV-in-TAVR with a second supra-annular self-expanding (S-SE) TAVR (10%, p = 0.04). Specifically, the rate of severe PPM was significantly higher among cases of a SE TAVR implanted into a balloon-expandable (BE) device (19%, p = 0.003). At 1-year follow-up, the rate of all-cause mortality, and the rate of patients in the New York Heart Association (NYHA) class III/IV were significantly higher in the cohort of patients with severe PPM (p = 0.016 and p = 0.0001, respectively). Almost all the patients with a severe PPM after the first TAVR had a failed < 23 mm BE transcatheter heart valve (THV): the treatment with an S-SE resolved the severe PPM in the majority of the cases. Conclusion: After TAV-in-TAVR, in a fifth of the cases, a moderate or severe PPM occurred. A severe PPM is associated with an increased 1-year all-cause mortality. Clinical trial registration: [https://clinicaltrials.gov], identifier [NCT04500964].

6.
Cardiovasc Revasc Med ; 35: 19-26, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33933374

RESUMEN

PURPOSE: To compare in-hospital outcome of Evolut-R 34 mm vs. smaller Evolut-R devices and to identify predictors of paravalvular leak (PVL) and deep implantation specific for Evolut-R 34 mm. METHODS: This single-center retrospective study included 359 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with Evolut-R 34 mm (N = 84,23.4%) and Evolut-R 23/26/29 mm (N = 275,76.6%) between 2016 and 2019. RESULTS: Patients in Evolut-R 34 mm group were more frequently males, had lower STS score, ejection fraction, and mean aortic gradient compared to the Evolut-R 23/26/29 mm group. Horizontal aorta and large LVOT were more frequent findings in the Evolut-R 34 mm group, whereas calcium volume was comparable among the groups. During TAVR, mean implantation depth and contrast volume were greater in the Evolut-R 34 mm group, compared to the Evolut 23/26/29 mm group. Post-procedurally, 30-day mortality, ≥moderate PVL, device success and pacemaker implantation (PM) rates were comparable between groups. Among independent predictors of ≥moderate PVL, calcium volume (OR:1.04; p < 0.001) was predictive with different thresholds in both groups, whereas aortic angulation (OR:1.40; p = 0.005) was predictive only in Evolut-R 34 mm group at a cutoff of 60° (AUC:0.73; p = 0.043). Body weight (OR:1.03; p = 0.027), left ventricular outflow tract (LVOT) diameter (OR:1.34; p = 0.001), and mean aortic gradient (OR:0.96; p = 0.006) were independent predictors of deep implantation (mean depth ≥ 6 mm), with LVOT>27 mm being predictive specifically for Evolut-R 34 mm (AUC:0.66; p = 0.024). CONCLUSIONS: TAVR with Evolut-R 34 mm and Evolut-R 23/26/29 mm showed comparable in-hospital outcome. Aortic angulation >60° and LVOT >27 mm were predictive respectively of ≥moderate PVL and deep implantation specifically in Evolut-R 34 mm patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hospitales , Humanos , Masculino , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 99(4): 1277-1286, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34939726

RESUMEN

OBJECTIVES: To evaluate the prognostic impact of baseline tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio, as an expression of the right ventricle-pulmonary artery (RV-PA) coupling, in patients with mitral regurgitation (MR) treated with the MitraClip. BACKGROUND: Impaired RV to PA coupling is considered a marker of RV dysfunction. METHODS: From February 2016 to February 2020, a total of 165 patients were evaluated and stratified in two groups according to a prespecified value of TAPSE/PASP ratio ≤ 0.36. RESULTS: The median patients' age was 79 (men: 62.4%). Sixty-three patients (38.1%) presented TAPSE/PASP ≤ 0.36 and were then compared with patients with TAPSE/PASP > 0.36. Functional MR etiology was more frequent in TAPSE/PASP ≤ 0.36 (71.4%; p = 0.046). Acute technical success was achieved in 92.7% of the population, without any significant difference between the two groups of study and with sustained results at 30-day (device success: 85.5%; procedural success: 84.8%). On multivariate Cox regression analysis, after correction for body mass index, chronic kidney disease and left ventricle ejection fraction ≥30% but <50%, TAPSE/PASP ≤ 0.36 remained a sustained predictor of mortality and hospitalization for heart failure at one year after MitraClip (hazard ratio: 3.87; 95% confidence interval: 1.83-8.22; p ≤ 0.001). Kaplan-Meier all-cause mortality and heart failure hospitalization rates at one year were consequently higher in patients with TAPSE/PASP ≤ 0.36 (39.4% vs. 14.8%; log-rank p ≤ 0.001). CONCLUSION: Baseline TAPSE/PASP ratio seems independently associated with all-cause mortality and heart failure hospitalization after MitraClip both in functional and degenerative MR.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Disfunción Ventricular Derecha , Ventrículos Cardíacos , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Pronóstico , Arteria Pulmonar/diagnóstico por imagen , Resultado del Tratamiento , Función Ventricular Derecha
8.
J Mech Behav Biomed Mater ; 123: 104772, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34481297

RESUMEN

Computational simulations of Transcatheter Aortic Valve Implantation (TAVI) have reached a high level of complexity and accuracy for the prediction of possible implantation scenarios during the decision-making process. However, when focusing on the prosthetic device, currently different devices are available on the market which not only have different geometries, but also different material properties. The present work focuses on the calibration of Nitinol constitutive parameters of four self-expandable devices starting from experimental radial force tests on the prosthetic samples. Beside providing optimal material properties for each specific device, we also perform a patient-specific simulation, comparing the results obtained using both "literature" and calibrated parameters with the aim of investigating the impact of metallic frame parameters choice on simulation results.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica , Simulación por Computador , Análisis de Elementos Finitos , Humanos , Fenómenos Mecánicos , Diseño de Prótesis , Resultado del Tratamiento
9.
G Ital Cardiol (Rome) ; 22(9 Suppl 1): 21S-28S, 2021 09.
Artículo en Italiano | MEDLINE | ID: mdl-34590621

RESUMEN

Transcatheter aortic valve implantation (TAVI) has become an established alternative to surgery in patients with calcific aortic stenosis. Broad implementation of devices and increased experience have led operators to explore the feasibility of TAVI in off-label indication such as pure native aortic valve regurgitation. Given the technical issues related to the absence of leaflet calcification and aortic root or ascending aorta dilation, this procedure is typically performed in patients in whom surgical risk is deemed prohibitive. Although recently published data have shown encouraging results in patients treated with new generation prostheses, new iteration of transcatheter valves, specifically designed for the treatment of aortic regurgitation, is needed. Nowadays, with no dedicated system on the horizon and in order to guarantee the best results, efforts should be made to improve patient selection.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Resultado del Tratamiento
10.
J Cardiovasc Dev Dis ; 8(9)2021 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-34564131

RESUMEN

BACKGROUND: TAVR is a safe alternative to surgical aortic valve replacement (SAVR); however, sex-related differences are still debated. This research aimed to examine gender differences in a real-world transcatheter aortic valve replacement (TAVR) cohort. METHODS: All-comer aortic stenosis (AS) patients undergoing TAVR with a Medtronic valve across 19 Italian sites were prospectively included in the Italian Clinical Service Project (NCT01007474) between 2007 and 2019. The primary endpoint was 1-year mortality. We also investigated 3-year mortality, and ischemic and hemorrhagic endpoints, and we performed a propensity score matching to assemble patients with similar baseline characteristics. RESULTS: Out of 3821 patients, 2149 (56.2%) women were enrolled. Compared with men, women were older (83 ± 6 vs. 81 ± 6 years, p < 0.001), more likely to present severe renal impairment (GFR ≤ 30 mL/min, 26.3% vs. 16.3%, p < 0.001) but had less previous cardiovascular events (all p < 0.001), with a higher mean Society of Thoracic Surgeons (STS) score (7.8% ± 7.1% vs. 7.2 ± 7.5, p < 0.001) and a greater mean aortic gradient (52.4 ± 15.3 vs. 47.3 ± 12.8 mmHg, p < 0.001). Transfemoral TAVR was performed more frequently in women (87.2% vs. 82.1%, p < 0.001), with a higher rate of major vascular complications and life-threatening bleeding (3.9% vs. 2.4%, p = 0.012 and 2.5% vs. 1.4%, p = 0.024). One-year mortality differed between female and male (11.5% vs. 15.0%, p = 0.002), and this difference persisted after adjustment for significant confounding variables (Adj.HR1yr 1.47, 95%IC 1.18-1.82, p < 0.001). Three-year mortality was also significantly lower in women compared with men (19.8% vs. 24.9%, p < 0.001) even after adjustment for age, STS score, eGFR, diabetes and severe COPD (Adj.HR3yr 1.42, 95%IC 1.21-1.68, p < 0.001). These results were confirmed in 689 pairs after propensity score matching. CONCLUSION: Despite higher rates of peri-procedural complications, women presented better survival than men. This better adaptive response to TAVR may be driven by sex-specific factors.

12.
Circ Cardiovasc Interv ; 14(6): e010440, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34092097

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has determined a paradigm shift in the treatment of patients with severe aortic stenosis. However, the durability of bioprostheses is still a matter of concern, and little is known about the management of degenerated TAV. We sought to evaluate the outcomes of patients with a degenerated TAV treated by means of a second TAVR. METHODS: The TRANSIT is an international registry that included cases of degenerated TAVR from 28 centers. Among around 40 000 patients treated with TAVR in the participating centers, 172 underwent a second TAVR: 57 (33%) for a mainly stenotic degenerated TAV, 97 (56%) for a mainly regurgitant TAV, and 18 (11%) for a combined degeneration. Overall, the rate of New York Heart Association class III/IV at presentation was 73.5%. RESULTS: Valve Academic Research Consortium 2 device success rate was 79%, as a consequence of residual gradient (14%) or regurgitation (7%). At 1 month, the overall mortality rate was 2.9%, while rates of new hospitalization and New York Heart Association class III/IV were 3.6% and 7%, respectively, without significant difference across the groups. At 1 year, the overall mortality rate was 10%, while rates of new hospitalization and New York Heart Association class III/IV were 7.6% and 5.8%, respectively, without significant difference across the groups. No cases of valve thrombosis were recorded. CONCLUSIONS: Selected patients with a degenerated TAV may be safely and successfully treated by means of a second TAVR. This finding is of crucial importance for the adoption of the TAVR technology in a lower risk and younger population. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04500964.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 98(6): E847-E854, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-33960624

RESUMEN

AIMS: The aim of this proof-of-concept study was to investigate safety and efficacy of a CT-scan based patient-specific algorithm to maximize coronary clearance and secondarily to achieve anatomically correct commissural alignment with the Acurate Neo device. METHOD AND RESULTS: A total of 45 consecutive patients undergoing TAVR with the Acurate Neo THV were prospectively enrolled in the study. Mean age was 81.6 ± 5.5 years, mean STS score was 6.1 ± 3.7. Device success rate was 100%. Aim of the technique was to rotationally deploy the TAVR device with a commissure lying on the bisector between the coronary ostia as calculated on the pre-procedural CT-scan. At post-TAVR CT-scan, coronary clearance was achieved in 98% of patients with no cases of severe coronary artery overlap. In 42 out of 45 patients, THV was aligned or, at most, mildly misaligned; there were 2 cases of moderate misalignment without any case of severe misalignment. Post-TAVR selective coronary artery engagement was attempted and succeeded in all patients (100%). CONCLUSION: Our CT-scan based patient-specific algorithm is safe and proven to be effective in avoiding coronary artery overlap and providing commissural alignment with Acurate Neo in all treated patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Algoritmos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Resultado del Tratamiento
14.
Future Cardiol ; 17(4): 619-624, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33599132

RESUMEN

The new iteration of the Portico transcatheter heart valve delivery system, the FlexNav, has been designed to enhance procedural safety and accuracy of the platform. Major technological advancements were the significant reduction of the insertion profile, allowing a transfemoral access down to 5.0 mm vessels, and the addition of a stability layer, improving deployment accuracy and thus potentially reducing implantation depth and permanent pacemaker implantation rate. Published data on patients undergoing Portico transcatheter heart valve implantation with the new FlexNav delivery system confirms excellent procedural and 30-day safety profile.


Lay abstract Transcatheter aortic valve replacement, a minimally invasive alternative to surgical aortic valve replacement, has become an established treatment option for patients with severe aortic stenosis approved across the entire spectrum of risk, from patient's ineligible for surgery to those at low risk. With the rapid spread of transcatheter aortic valve replacement to younger patients, researchers are focusing on reducing procedural adverse events rates, such as pacemaker implantation or access site-related complication, and increase procedural accuracy. The new FlexNav delivery system, employed to implant the Portico transcatheter heart valve, had recently proved its procedural safety and, with its major technological advancements encompassing a reduced insertion profile and an improved device stability during implant, may significantly reduce pacemaker implantation and access site-related complication rate.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 97(1): E135-E145, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32400068

RESUMEN

OBJECTIVES: To investigate paravalvular leak (PVL) and devices success rates according to aortic angle (AA) in patients undergoing transcatheter aortic valve implantation (TAVI) with three new-generation self-expanding devices. BACKGROUND: The impact of aortic angle (AA) on TAVI device success and PVL rates is controversial. METHODS: This retrospective study included 392 patients submitted to TAVI for severe aortic stenosis with Portico, Evolut-R and Acurate-NEO, and available AA measurements at computed tomography (CT) angiography. AA was calculated from the implantation projection and was defined as the angle between the plane of aortic annulus and an ideal horizontal plane. Aorta was defined horizontal if AA>57° (75th percentile). RESULTS: In the horizontal group, the rates of moderate/severe PVL was higher in the Evolut-R group (20.8%), which was also characterized by a lower implant compared to that of Acurate-NEO, whereas device success was comparable among the three devices. AA was a significant predictor of moderate/severe PVLs (AUC 0.72, p = .002) only in the Evolut-R population. On multivariate analysis, calcium volume 850HU, bicuspid aortic valve, and implantation depth at the level of left coronary cusp were independent predictors of moderate/severe PVL. On univariate analysis in the horizontal aorta population, implantation depth was confirmed among the most significant predictors of moderate/severe PVL. CONCLUSIONS: Despite comparable device success rates, horizontal aorta represented a technical challenge only in the Evolut-R subgroup, which showed higher rates of moderate/severe PVL than Portico and Acurate-NEO, and was associated with a low implant.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Aorta , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Complicaciones Posoperatorias , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Interact Cardiovasc Thorac Surg ; 32(1): 20-28, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33201993

RESUMEN

OBJECTIVES: To compare device success and paravalvular leak rates of 3 new-generation transcatheter aortic valve replacement devices in patients with bicuspid aortic valve stenosis and to test their biomechanical performance in a computer-based simulation model of aortic root with increasing ellipticity. METHODS: This retrospective multicentre study included 56 bicuspid aortic valve patients undergoing transcatheter aortic valve replacement with new-generation devices: Lotus/Lotus Edge (N = 15; 27%), Evolut-R (N = 20; 36%) and ACURATE neo (N = 21; 37%). Three virtual simulation models of aortic root with increasing index of eccentricity (0-0.25-0.5) were implemented. Stress distribution, stent-root contact area and paravalvular orifice area were computed. RESULTS: Device success was achieved in 43/56 patients (77%) with comparable rates among Lotus (87%), Evolut-R (60%) and ACURATE neo (86%; P = 0.085). Moderate paravalvular leak rate was significantly lower in the Lotus group as compared to Evolut-R group (0% vs 30%; P = 0.027) and comparable to the ACURATE neo group (0% vs 10%; P = 0.33). By index of eccentricity = 0.5, Lotus showed a uniform and symmetric pattern of stress distribution with absent paravalvular orifice area, ACURATE neo showed a mild asymmetry with small paravalvular orifice area (1.1 mm2), whereas a severely asymmetric pattern was evident with Evolut-R, resulting in a large paravalvular orifice area (12.0 mm2). CONCLUSIONS: Transcatheter aortic valve replacement in bicuspid aortic valve patients with new-generation devices showed comparable device success rates. Lotus showed moderate paravalvular leak rate comparable to that of ACURATE neo and significantly lower than Evolut-R. On simulation, Lotus and ACURATE neo showed optimal adaptability to elliptic anatomies as compared to Evolut-R.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Constricción Patológica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Aorta/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Humanos , Masculino , Estudios Retrospectivos , Stents , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 98(1): E145-E152, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33155757

RESUMEN

OBJECTIVE: This study sought to investigate the procedural and mid-term outcomes of transcatheter aortic valve implantation for failed surgical bioprostheses (TAVI-ViV) with Portico device. BACKGROUND: Limited evidence coming from early experience on Portico system does not allow to fully assess safety and efficacy of this device in this ViV patients. METHODS: From January 2016 up to June 2019, 56 consecutive patients undergoing TAVI-ViV with Portico were prospectively included in our institutional TAVI database. RESULTS: The prevalent mechanism of failure was stenosis (58.9%); true internal diameter (ID) was <21 mm in 71.4% of cases. Device success rate were 69.6% with 14 (25%) patients showing a residual gradient ≥20 mmHg, 2 (3.6%) a PVL ≥ moderate and 1 (1.8%) required a second THV implantation due to device embolization. At 1-year follow-up 5 patients (8.9%) died whereas moderate SVD was reported in 2 (3.6%). Patients with a post-procedural mean gradient ≥20 mmHg showed a significantly higher rate of CV hospitalization (21.4% vs. 2.4%, p = .02) whereas no differences in procedural and 1-year outcomes were noticed according to true ID diameter or degeneration mode. Chimney stenting (ChT) was performed in 23 (41%) patients without significant differences in procedural and 1-year outcomes compared to non-ChT group. CONCLUSIONS: TAVI-ViV with Portico valve was associated with good procedural and 1-year outcomes, even in patients with features of high procedural and anatomical complexity.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
Eur Heart J ; 41(20): 1876-1886, 2020 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-31904800

RESUMEN

AIMS: In the last decade, transcatheter aortic valve (TAV) replacement determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis. Data on long-term TAV performance are still limited. We sought to evaluate the clinical and haemodynamic outcomes of the CoreValve self-expandable valve up to 8-year follow-up (FU). METHODS AND RESULTS: Nine hundred and ninety inoperable or high-risk patients were treated with the CoreValve TAV in eight Italian Centres from June 2007 to December 2011. The median FU was 4.4 years (interquartile range 1.4-6.7 years). Longest FU reached 11 years. A total of 728 died within 8-year FU (78.3% mortality from Kaplan-Meier curve analysis). A significant functional improvement was observed in the majority of patients and maintained over time, with 79.3% of surviving patients still classified New York Heart Association class ≤ II at 8 years. Echocardiographic data showed that the mean transprosthetic aortic gradient remained substantially unchanged (9 ± 4 mmHg at discharge, 9 ± 5 mmHg at 8 years, P = 0.495). The rate of Grade 0/1 paravalvular leak was consistent during FU with no significant change from post-procedure to FU ≥5 years in paired analysis (P = 0.164). Structural valve deterioration (SVD) and late bioprosthetic valve failure (BVF) were defined according to a modification of the 2017 EAPCI/ESC/EACTS criteria. In cumulative incidence functions at 8 years, moderate and severe SVD were 3.0% [95% confidence interval (CI) 2.1-4.3%] and 1.6% (95% CI 0.6-3.9%), respectively, while late BVF was 2.5% (95% CI 1.2-5%). CONCLUSION: While TAVs are questioned about long-term performance and durability, the results of the present research provide reassuring 8-year evidence on the CoreValve first-generation self-expandable bioprosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
20.
Am Heart J ; 217: 32-41, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31473325

RESUMEN

Limited evidence is available on 5-year clinical outcomes after percutaneous edge-to-edge mitral valve repair. METHODS: The Getting Reduction of mitrAl inSufficiency by Percutaneous clip implantation in ITaly (GRASP-IT) is a multicenter registry including 304 consecutive patients undergoing Mitraclip between October 2008 and October 2013 at 4 Italian centers. Primary end point (all-cause mortality) and secondary end point (all-cause mortality or heart failure [HF] hospitalization) were evaluated up to 5 years and between 1 and 5 years. RESULTS: Cumulative incidence of the primary and secondary end points at 1, 2, 3, 4, and 5 years were 15.1%, 26.4%, 35.5%, 42.1%, and 47.3% and 29.1%, 41.7%, 49.8%, 56%, and 62.3%, respectively. Landmark analysis between 1 and 5 years showed an incidence of primary and secondary end point of 37.9% and 46.8%, respectively. Five-year event rates were significantly higher in patients with functional ischemic mitral regurgitation (MR) compared to other etiologies. MR recurrence and left ventricular ejection fraction <30% were associated with an increased risk of both primary and secondary end points. EuroSCORE II >5% was associated with an increased risk of 5-year mortality. Ischemic etiology of MR, baseline serum creatinine >1.5 mg/dL, chronic obstructive pulmonary disease, and previous HF hospitalizations were independent predictors of 5-year secondary end point. CONCLUSIONS: At 5-year follow-up after Mitraclip, nearly half of patients died and almost two thirds died or were admitted for HF. MR recurrence, ischemic etiology, high comorbidity burden (ie, EuroSCORE II >5%, chronic obstructive pulmonary disease), and advanced cardiomyopathy (ie, left ventricular ejection fraction <30%, prior HF admission, creatinine >1.5 mg/dL) significantly increase the relative risk of 5-year clinical events.


Asunto(s)
Insuficiencia Cardíaca/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Complicaciones Posoperatorias/epidemiología , Anciano , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Causas de Muerte , Femenino , Insuficiencia Cardíaca/etiología , Hospitalización/estadística & datos numéricos , Humanos , Incidencia , Italia , Masculino , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/mortalidad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Recurrencia , Sistema de Registros/estadística & datos numéricos , Estudios Retrospectivos , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda