Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
2.
Artículo en Inglés | MEDLINE | ID: mdl-38652393

RESUMEN

Transposition of the great arteries (TGA) is a cyanotic congenital heart disease characterized by ventriculoarterial discordance and atrioventricular concordance with the great arteries in a parallel relationship. Prenatal diagnosis of TGA has implications for postnatal outcomes, allowing for planned delivery and perinatal management. Three-dimensional virtual or physical models of fetal TGA allow better understanding of fetal cardiac anomalies by parents and interactive discussion among the multidisciplinary team (obstetricians, pediatricians, maternal-fetal specialists, pediatric cardiologists, and cardiovascular surgeons), as well as continuing medical education.

3.
J Clin Ultrasound ; 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38619183

RESUMEN

Three-dimensional reconstructions provide a spatial view of the congenital heart disease with a better understanding of the pathology for parents and allow interactive discussion among the medical team (maternal-fetal medicine specialist, neonatology, pediatric cardiology, and cardiovascular surgeon) and improve both objective knowledge and learner satisfaction for medical students.

4.
Echocardiography ; 41(4): e15806, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38549419

RESUMEN

3D virtual and physical models from ultrasound scan data allow a 3D spatial view of congenital heart anomalies, interactive discussion among a multidisciplinary team, and improved parental counseling. To the best of our knowledge, this is the first description of 3D physical and virtual models of a fetal Ebstein anomaly.


Asunto(s)
Anomalía de Ebstein , Cardiopatías Congénitas , Embarazo , Femenino , Humanos , Anomalía de Ebstein/diagnóstico por imagen , Ultrasonografía Prenatal
5.
PLoS One ; 19(3): e0297975, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38551934

RESUMEN

BACKGROUND: This study evaluated the long-term effects of percutaneous intervention in children and adolescents with transplant renal artery stenosis (TRAS). METHODS: Twenty patients had significant stenosis (>50%) and underwent percutaneous transluminal angioplasty (PTA/stenting) (TRAS group-intervention); 14 TNS (non-significant group -control) patients did not have significant stenosis (≤50%) and were treated clinically. The combined primary endpoints were death from all causes and late graft failure. The secondary endpoints were serum creatinine (SCr), systolic blood pressure (SBP), and diastolic blood pressure (DBP). RESULTS: No statistically significant difference was found between TRAS-Intervention(N = 20) and TNS groups-Control (N = 14) for these clinical parameters: deaths, 1 (5.0%) vs. 0 (0.0%) (p = 1.000) and graft loss, 4 (20.0%) vs. 2 (14.3%) (p = 1.000). For the secondary endpoints, after 1 month and 1 year the values of SCr, SBP, and DBP were similar between the two groups but not statistically significant. DISCUSSION: In the TRAS group (intervention), the stent implantation was beneficial for treating refractory hypertension and reducing blood pressure (BP) in children and adolescents. Despite the outcomes being similar in the two groups, it can be inferred that the patients in the TRAS group (intervention) would have had a worse outcome without the percutaneous intervention. CONCLUSION: TRAS treatment with stenting can be considered for children and adolescents. Because the sample in the present study comprised of only a specific population, further studies are needed for generalization. TRIAL REGISTRATION: The trial was registered at clinictrials.gov with trial registration number NCT04225338.


Asunto(s)
Angioplastia de Balón , Trasplante de Riñón , Obstrucción de la Arteria Renal , Niño , Humanos , Adolescente , Angioplastia de Balón/efectos adversos , Arteria Renal , Trasplante de Riñón/efectos adversos , Estudios Retrospectivos , Constricción Patológica/complicaciones , Resultado del Tratamiento , Obstrucción de la Arteria Renal/cirugía , Obstrucción de la Arteria Renal/etiología , Riñón , Hospitales Públicos , Stents/efectos adversos
6.
Rev Assoc Med Bras (1992) ; 70(2): e20230700, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38451573

RESUMEN

OBJECTIVE: This study aimed to evaluate cardiac contractility in fetuses from pregestational diabetes mellitus pregnancies by three-dimensional ultrasound using spatiotemporal image correlation in rendering mode. METHODS: A retrospective cross-sectional study was performed on 40 fetuses from nondiabetic pregnancies and 28 pregestational diabetic pregnancies between 20 and 33 weeks and 6 days. Cardiac contractility was assessed by measuring the ventricular myocardial area in diastole subtracted from the ventricular myocardial area in systole. RESULTS: Pregestational diabetic pregnancies had a lower maternal age than nondiabetic pregnancies (26.7 vs. 39.9 years, p=0.019). Cardiac contractility in fetuses from diabetic and nondiabetic pregnancies was similar (p=0.293). A moderately positive and significant correlation was observed between gestational age and cardiac contractility (r=0.46, p=0.0004). A 1-week increase in gestational age was responsible for a 0.1386 cm2 increase in cardiac contractility. CONCLUSION: Cardiac contractility as evaluated by three-dimensional ultrasound using spatiotemporal image correlation in rendering mode showed no significant differences across fetuses with and without pregestational diabetes.


Asunto(s)
Diabetes Mellitus , Embarazo en Diabéticas , Femenino , Embarazo , Humanos , Estudios Transversales , Estudios Retrospectivos , Feto , Embarazo en Diabéticas/diagnóstico por imagen
8.
Cardiol Young ; 34(2): 319-324, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37408451

RESUMEN

OBJECTIVE: To assess the impact of overweight and obesity in the second and third trimesters of pregnancy on fetal cardiac function parameters. METHODS: We performed a prospective cohort study of 374 singleton pregnant women between 20w0d and 36w6d divided into three groups: 154 controls (body mass index - BMI < 25 kg/m2), 140 overweight (BMI 25-30 kg/m2) and 80 obese (BMI ≥ 30 kg/m2). Fetal left ventricular (LV) modified myocardial performance index (Mod-MPI) was calculated according to the following formula: (isovolumetric contraction time + isovolumetric relaxation time)/ejection time. Spectral tissue Doppler was used to determine LV and right ventricular (RV) myocardial performance index (MPI'), peak myocardial velocity during systole (S'), early diastole (E'), and late diastole (A'). RESULTS: We found significant differences between the groups in maternal age (p < 0.001), maternal weight (p < 0.001), BMI (p < 0.001), number of pregnancies (p < 0.001), parity (p < 0.001), gestational age (p = 0.013), and estimated fetal weight (p = 0.003). Overweight pregnant women had higher LV Mod-MPI (0.046 versus 0.044 seconds, p = 0.009) and LV MPI' (0.50 versus 0.47 seconds, p < 0.001) than the control group. Obese pregnant women had higher RV E' than control (6.82 versus 6.33 cm/sec, p = 0.008) and overweight (6.82 versus 6.46 cm/sec, p = 0.047) groups. There were no differences in 5-min APGAR score < 7, neonatal intensive care unit admission, hypoglycemia and hyperglobulinemia between the groups. CONCLUSIONS: We observed fetal myocardial dysfunction in overweight and obese pregnant women with higher LV Mod-MPI, LV MPI' and RV E' compared to fetuses from normal weight pregnant women.


Asunto(s)
Ecocardiografía Doppler , Corazón Fetal , Recién Nacido , Embarazo , Femenino , Humanos , Tercer Trimestre del Embarazo , Corazón Fetal/diagnóstico por imagen , Estudios Prospectivos , Sobrepeso/complicaciones , Sobrepeso/epidemiología , Obesidad/complicaciones , Obesidad/epidemiología , Ultrasonografía Prenatal
9.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 70(2): e20230700, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1535096

RESUMEN

SUMMARY OBJECTIVE: This study aimed to evaluate cardiac contractility in fetuses from pregestational diabetes mellitus pregnancies by three-dimensional ultrasound using spatiotemporal image correlation in rendering mode. METHODS: A retrospective cross-sectional study was performed on 40 fetuses from nondiabetic pregnancies and 28 pregestational diabetic pregnancies between 20 and 33 weeks and 6 days. Cardiac contractility was assessed by measuring the ventricular myocardial area in diastole subtracted from the ventricular myocardial area in systole. RESULTS: Pregestational diabetic pregnancies had a lower maternal age than nondiabetic pregnancies (26.7 vs. 39.9 years, p=0.019). Cardiac contractility in fetuses from diabetic and nondiabetic pregnancies was similar (p=0.293). A moderately positive and significant correlation was observed between gestational age and cardiac contractility (r=0.46, p=0.0004). A 1-week increase in gestational age was responsible for a 0.1386 cm2 increase in cardiac contractility. CONCLUSION: Cardiac contractility as evaluated by three-dimensional ultrasound using spatiotemporal image correlation in rendering mode showed no significant differences across fetuses with and without pregestational diabetes.

10.
Diagnostics (Basel) ; 13(23)2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-38066750

RESUMEN

The purpose of this article is to describe the evaluation of a variety of congenital heart diseases (CHDs) using three-dimensional (3D) ultrasound with different software, such as Cristal Vue, Realistic Vue, LumiFlow, and Spatiotemporal Image Correlation (STIC), with HDlive and HDlive Flow Silhouette modes. These technologies provide realistic images of the fetal heart and cardiac vessels using a fixed virtual light source that allows the operator to freely select a better light source position to enhance the cardiovascular anatomical details. In addition, Fetal Intelligent Navigation Echocardiography (FINE) technology, also known as "5D Heart" or "5D", is a technology that enables the automatic reconstruction of the nine standard fetal echocardiographic views and can alert non-specialists to suspected CHD. Through the use of artificial intelligence, an ultrasound machine is able to perform automatic anatomical and functional measurements. In addition, hese technologies enable the reconstruction of fetal cardiac structures in realistic images, improving the depth perception and resolution of anatomic cardiac details and blood vessels compared to those of standard two-dimensional (2D) ultrasound.

11.
Radiol. bras ; 56(5): 282-286, Sept.-Oct. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1529312

RESUMEN

Abstract Hypoplastic left heart syndrome (HLHS) is characterized by underdevelopment of the left-sided heart structures. The prenatal diagnosis of this congenital heart disease is crucial because a newborn with undiagnosed HLHS often presents with clinical signs of low cardiac output once the ductus arteriosus begins to close. With that in mind, the aim of this article was to perform a non-systematic review focusing on the key ultrasound features that can be used in the prenatal diagnosis of HLHS. Severe forms of HLHS are characterized by a markedly abnormal four-chamber view of the fetal heart (small left atrium, hypoplastic left ventricle, or abnormal mitral valve). The left ventricular outflow tract view allows the degree of hypoplasia in the tract to be evaluated and the diameter of the ascending aorta to be measured. The Z-scores are intended to aid in the diagnosis and follow-up of HLHS. In mild forms of HLHS, a right ventricle/left ventricle length ratio > 1.28 was the strongest predictor of a univentricular outcome.


Resumo A síndrome do coração esquerdo hipoplásico (SCEH) é caracterizada pelo subdesenvolvimento das estruturas cardíacas do lado esquerdo. O diagnóstico pré-natal dessa cardiopatia congênita é crucial, uma vez que recém-nascido com SCEH não diagnosticado apresenta, frequentemente, sinais clínicos de baixo débito cardíaco, quando o canal arterial começa a se fechar. Por isso, o objetivo deste artigo foi realizar uma revisão não sistemática sobre as principais características ultrassonográficas que podem ser usadas no diagnóstico pré-natal da SCEH. As formas graves de SCEH são caracterizadas por plano de quatro câmaras marcadamente anormal (átrio esquerdo pequeno, ventrículo esquerdo hipoplásico, válvula mitral anormal) do coração fetal. A visualização da via de saída do ventrículo esquerdo permite a avaliação do grau de hipoplasia dessa via e a mensuração da aorta ascendente. Os escores Z têm como objetivo auxiliar no diagnóstico e acompanhamento da SCEH. Nas formas leves da SCEH, a relação comprimento do ventrículo direito/comprimento do ventrículo esquerdo > 1,28 foi a variável mais forte para identificar o desfecho univentricular.

12.
J Matern Fetal Neonatal Med ; 36(1): 2203791, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37080921

RESUMEN

OBJECTIVE: This study aimed to analyze prenatal diagnosis, perinatal outcomes, and postnatal follow-up in fetuses with ectopia cordis (EC). METHODS: This retrospective analysis accessed 31 patients with EC who were either diagnosed or referred to a tertiary Fetal Medicine centers for EC diagnosis in Brazil, Germany, Italy, and Poland. We analyzed prenatal diagnosis, perinatal outcomes, and follow-up in these patients. RESULTS: Our study included a cohort of 31 fetuses with EC, 4 and 27 of whom had partial and complete protrusion of the heart through a ventral defect in the thoracoabdominal wall, respectively. EC was diagnosed by fetal echocardiography at a mean gestational age of 20.3 ± 8.6 weeks (range, 8-35 weeks). Of the four cases, in which the karyotype was performed, all of them had a normal result (1 - 46,XX and 3 - 46,XY). Five patients showed conotruncal abnormalities and six ventricular septal defects. Termination of pregnancy (TOP) was performed in 15 cases (48%) and seven pregnant women had spontaneous fetal demise (22.5%). Of the seven fetuses that were born alive, four of them died, and three infants underwent surgery. Among these three infants, all of them survived, one was 5 months, 13 years old and 29 years old at the time of study completion. CONCLUSIONS: Ectopia cordis is associated with high mortality rates and intracardiac/extra-cardiac defects. Ventricular septal defects and conotruncal anomalies were the more common intracardiac defects associated with EC. However, in this cohort of fetuses with EC the incidence of PC was lower than reported in the literature.


Asunto(s)
Ectopía Cordis , Cardiopatías Congénitas , Defectos del Tabique Interventricular , Lactante , Humanos , Embarazo , Femenino , Adolescente , Ectopía Cordis/diagnóstico por imagen , Estudios Retrospectivos , Estudios de Seguimiento , Ultrasonografía Prenatal , Diagnóstico Prenatal , Cardiopatías Congénitas/diagnóstico
13.
Rev Assoc Med Bras (1992) ; 69(4): e20221215, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37075365

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the right ventricular myocardial performance index) based on echocardiography in very low birth weight premature neonates, close to hospital discharge. METHODS: This was a prospective cross-sectional study that included premature neonates with birth weight <1,500 g and gestational age <37 weeks at the Intermediate Neonatal Unit of Bonsucesso Federal Hospital from July 2005 to July 2006. The infants underwent two-dimensional color Doppler echocardiography, being the right ventricular myocardial performance index evaluated close to hospital discharge. We compared the neonatal and echocardiographic variables in neonates with and without bronchopulmonary dysplasia. RESULTS: A total of 81 exams were analyzed. The mean birth (standard deviation) weight and gestational age were 1,140 (235) g and 30 (2.2) weeks, respectively. The incidence of bronchopulmonary dysplasia was 32%. The mean right ventricle myocardial performance index (standard deviation) of the sample was 0.13 (0.06). We found a significant difference in aortic diameter [non-bronchopulmonary dysplasia 0.79 (0.07) vs. bronchopulmonary dysplasia 0.87 (0.11) cm, p=0.003], left ventricle in diastole [non-bronchopulmonary dysplasia 1.4 (0.19) vs. bronchopulmonary dysplasia 1.59 (0.21) cm, p=0.0006], ventricular septal thickness [non-bronchopulmonary dysplasia 0.23 (0.03) vs. bronchopulmonary dysplasia 0.26 (0.05) cm, p=0.032], and "a" measurement [(= sum of the isovolumetric contraction time, ejection time, and isovolumetric relaxation time) when calculating the myocardial performance index (p=0.01)]. CONCLUSION: Higher "a" interval in neonates with bronchopulmonary dysplasia suggests right ventricle diastolic dysfunction. We conclude that the right ventricle myocardial performance index is an important indicator both of ventricular function and for serial follow-up testing of very low birth weight premature neonates, especially those with bronchopulmonary dysplasia.


Asunto(s)
Displasia Broncopulmonar , Ventrículos Cardíacos , Recién Nacido , Lactante , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Estudios Prospectivos , Estudios Transversales , Recien Nacido Prematuro , Ecocardiografía Doppler/métodos , Displasia Broncopulmonar/diagnóstico por imagen , Recién Nacido de muy Bajo Peso
16.
J Perinat Med ; 51(6): 805-814, 2023 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-36584322

RESUMEN

OBJECTIVES: To determine reference curves for fetal aortic and pulmonary valve annulus area by three-dimensional ultrasonography using the spatio-temporal image correlation (STIC) in the rendering mode, and to ascertain its applicability in congenital heart disease (CHD). METHODS: We performed a retrospective cross-sectional study of 328 normal fetuses and 42 fetuses with CHD between 20 and 33 weeks 6 days of gestation. The outflow plane view of the great vessels was used to measure the areas of the valvar annuli, and the measurements were performed in systole. A linear regression model adjusted according to the determination coefficient (R2) was utilized to construct the reference intervals. The concordance correlation coefficient (CCC) was used to calculate the reproducibility of the mitral and tricuspid valve areas. RESULTS: The mean ± standard deviation (SD) of the aortic and pulmonary valve annulus areas ranged from 6.6 ± 1.2 to 32.9 ± 1.1 mm2 and 10.7 ± 1.3 to 40.3 ± 1.2 mm2, respectively. We observed a linear relationship and strong positive correlation between the area of the aortic and pulmonary valve annuli with r=0.97 and 0.96, respectively. Good intra (CCC=0.99) and interobserver agreement (CCC=0.98) was observed for the measurement of the aortic valve annulus area. A good intra (CCC=0.99) and interobserver (CCC=0.97) agreement was also observed for the measurement of the pulmonary valve annulus area. The mean ± SD of the difference of the areas of the aortic and pulmonary valve annuli between the normal fetuses and those with CHD were -1.801 ± 1.429 mm2 (p=0.208) and -1.033 ± 1.467 mm2 (p<0.0001), respectively. CONCLUSIONS: The reference curves for the areas of the aortic and pulmonary valve annuli of fetal hearts were determined, and showed good inter and intraobserver reproducibility. The constructed reference curves showed applicability in different types of CHD.


Asunto(s)
Cardiopatías Congénitas , Válvula Pulmonar , Femenino , Embarazo , Humanos , Válvula Pulmonar/diagnóstico por imagen , Estudios Transversales , Reproducibilidad de los Resultados , Estudios Retrospectivos , Ultrasonografía Prenatal/métodos , Corazón Fetal/diagnóstico por imagen , Ultrasonografía , Cardiopatías Congénitas/diagnóstico por imagen
17.
Int J Cardiovasc Imaging ; 39(3): 531-539, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36334212

RESUMEN

To determine reference values for the foramen ovale (FO) area of fetal hearts by three-dimensional (3D) ultrasound using spatio-temporal image correlation (STIC) method in the rendering mode, as well as applicability in fetuses with congenital heart disease (CHD). A retrospective and prospective study was performed of 242 normal fetuses and 36 fetuses with CHD between 20 and 33 + 6 weeks of gestation. The FO area was determined in the four-chamber view with manual delineation. To determine the reference curve of the FO area as a function of gestational age (GA), a linear regression model was utilized with an adjusted coefficient of determination (R2). For intra- and interobserver reproducibility calculations, the concordance correlation coefficient (CCC) was used. The mean ± standard deviation (SD) of the FO measurement area was 21.2 ± 1.8 and 48.1 ± 1.9 mm2 at 20 and 33 weeks' gestation, respectively. A linear correlation was observed between the FO area and GA (1.924*GA - 17.95; R2 = 0.91). Good intra- (CCC = 0.97) and interobserver (CCC = 0.94) agreement was observed for the FO area measurement. The mean difference in FO area between normal and CHD fetuses was - 14.4 mm2 (p < 0.001). Reference values for the FO area of fetal hearts were determined by 3D ultrasound using STIC in the rendering mode. This method showed good intra- and interobserver reproducibility and could be used to assess different CHD types.


Asunto(s)
Ecocardiografía Tridimensional , Foramen Oval , Cardiopatías Congénitas , Femenino , Embarazo , Humanos , Ecocardiografía Tridimensional/métodos , Valores de Referencia , Estudios Prospectivos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Ultrasonografía Prenatal/métodos , Valor Predictivo de las Pruebas , Corazón Fetal/diagnóstico por imagen , Edad Gestacional
18.
J Clin Ultrasound ; 51(2): 225-239, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36468264

RESUMEN

This study aims to explore ultrasound (US) cardiac and echocardiographic features that may enable the early diagnosis of various major congenital heart diseases (CHDs). Focusing on providing useful US tools for this assessment, high resolution of US cardiac images of various CHDs, such as hypoplastic left heart syndrome, conotruncal anomalies, and univentricular heart, were evaluated. Results show that early US detection of most major CHDs is feasible during first-trimester ultrasonography cardiac evaluation. Concerns about safety issues, findings on early fetal cardiovascular hemodynamics, and cardiac lesions that can progress during the course of pregnancy were also discussed.


Asunto(s)
Cardiopatías Congénitas , Ultrasonografía Prenatal , Embarazo , Femenino , Humanos , Primer Trimestre del Embarazo , Ultrasonografía Prenatal/métodos , Diagnóstico Prenatal/métodos , Ecocardiografía/métodos , Ultrasonografía , Cardiopatías Congénitas/diagnóstico por imagen , Corazón Fetal/diagnóstico por imagen
19.
Radiol Bras ; 56(5): 282-286, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38204904

RESUMEN

Hypoplastic left heart syndrome (HLHS) is characterized by underdevelopment of the left-sided heart structures. The prenatal diagnosis of this congenital heart disease is crucial because a newborn with undiagnosed HLHS often presents with clinical signs of low cardiac output once the ductus arteriosus begins to close. With that in mind, the aim of this article was to perform a non-systematic review focusing on the key ultrasound features that can be used in the prenatal diagnosis of HLHS. Severe forms of HLHS are characterized by a markedly abnormal four-chamber view of the fetal heart (small left atrium, hypoplastic left ventricle, or abnormal mitral valve). The left ventricular outflow tract view allows the degree of hypoplasia in the tract to be evaluated and the diameter of the ascending aorta to be measured. The Z-scores are intended to aid in the diagnosis and follow-up of HLHS. In mild forms of HLHS, a right ventricle/left ventricle length ratio > 1.28 was the strongest predictor of a univentricular outcome.


A síndrome do coração esquerdo hipoplásico (SCEH) é caracterizada pelo subdesenvolvimento das estruturas cardíacas do lado esquerdo. O diagnóstico pré-natal dessa cardiopatia congênita é crucial, uma vez que recém-nascido com SCEH não diagnosticado apresenta, frequentemente, sinais clínicos de baixo débito cardíaco, quando o canal arterial começa a se fechar. Por isso, o objetivo deste artigo foi realizar uma revisão não sistemática sobre as principais características ultrassonográficas que podem ser usadas no diagnóstico pré-natal da SCEH. As formas graves de SCEH são caracterizadas por plano de quatro câmaras marcadamente anormal (átrio esquerdo pequeno, ventrículo esquerdo hipoplásico, válvula mitral anormal) do coração fetal. A visualização da via de saída do ventrículo esquerdo permite a avaliação do grau de hipoplasia dessa via e a mensuração da aorta ascendente. Os escores Z têm como objetivo auxiliar no diagnóstico e acompanhamento da SCEH. Nas formas leves da SCEH, a relação comprimento do ventrículo direito/comprimento do ventrículo esquerdo > 1,28 foi a variável mais forte para identificar o desfecho univentricular.

20.
J Med Ultrasound ; 31(4): 298-304, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38264598

RESUMEN

Background: The objective of this study was to assess the ascending and descending aorta area measurements by three-dimensional (3D) ultrasound using spatiotemporal image correlation (STIC) in the rendering mode comparing these measurements with pregestational diabetic mothers and assessing the reproducibility of the method. Methods: We carried out a retrospective cross-sectional study with 58 normal and nine fetuses from pregestational diabetic mothers between 20 and 33 + 6 weeks of gestation. Fetal heart volumes were acquired at the level of four-chamber view to obtain the reconstructed planes for the ascending and descending aorta areas in the rendering mode. Linear regression was performed to assess the correlation between the fetal aorta areas and gestational age (GA). To assess the intra- and interobserver reproducibility, we used the concordance correlation coefficient (CCC). Results: The mean ascending and descending aorta areas were 0.12 (0.02-0.48) and 0.11 (0.04-0.39) cm2 in normal fetuses, respectively. There was a moderate positive correlation between GA and ascending aorta area measurements (0.005676*GA - 0.01283; r = 0.53, P < 0.0001) and strong positive correlation between GA and descending aorta area (0.01095*GA - 0.1581; r = 0.68, P < 0.0001). We observed a weak intra- and interobserver reproducibility with CCC ranging from 0.05 to 0.91. The mean difference in the ascending and descending aorta area measurements of normal and fetuses of pregestational diabetic mothers was -0.03 cm2 (P = 0.276) and -0.03 cm2 (P = 0.231), respectively. Conclusion: The fetal ascending and descending aorta area measurements obtained by 3D ultrasound using STIC in the rendering mode increased with GA in normal fetuses. The method showed weak intra- and interobserver reproducibility.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA