Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Clin Chem Lab Med ; 62(6): 1080-1091, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38205643

RESUMEN

OBJECTIVES: Current liquid chromatography-tandem mass spectrometry (LC-MS/MS) applications for circulating androgen measurements are technically diverse. Previously, variable results have been reported for testosterone. Data are scarce for androstenedione and absent for dehydroepiandrosterone sulfate (DHEAS). We assessed the agreement of androstenedione, DHEAS and testosterone LC-MS/MS measurements among nine European centers and explored benefits of calibration system unification. METHODS: Androgens were measured twice by laboratory-specific procedures in 78 patient samples and in EQA materials. Results were obtained by in-house and external calibration. Intra- and inter-laboratory performances were valued. RESULTS: Intra-laboratory CVs ranged between 4.2-13.2 % for androstenedione, 1.6-10.8 % for DHEAS, and 4.3-8.7 % and 2.6-7.1 % for female and male testosterone, respectively. Bias and trueness in EQA materials were within ±20 %. Median inter-laboratory CV with in-house vs. external calibration were 12.0 vs. 9.6 % for androstenedione (p<0.001), 7.2 vs. 4.9 % for DHEAS (p<0.001), 6.4 vs. 7.6 % for female testosterone (p<0.001) and 6.8 and 7.4 % for male testosterone (p=0.111). Median bias vs. all laboratory median with in-house and external calibration were -13.3 to 20.5 % and -4.9 to 18.7 % for androstenedione, -10.9 to 4.8 % and -3.4 to 3.5 % for DHEAS, -2.7 to 6.5 % and -11.3 to 6.6 % for testosterone in females, and -7.0 to 8.5 % and -7.5 to 11.8 % for testosterone in males, respectively. CONCLUSIONS: Methods showed high intra-laboratory precision but variable bias and trueness. Inter-laboratory agreement was remarkably good. Calibration system unification improved agreement in androstenedione and DHEAS, but not in testosterone measurements. Multiple components, such as commutability of calibrators and EQA materials and internal standard choices, likely contribute to inter-laboratory variability.


Asunto(s)
Androstenodiona , Sulfato de Deshidroepiandrosterona , Espectrometría de Masas en Tándem , Testosterona , Androstenodiona/sangre , Androstenodiona/análisis , Testosterona/sangre , Testosterona/análisis , Testosterona/normas , Humanos , Espectrometría de Masas en Tándem/normas , Espectrometría de Masas en Tándem/métodos , Calibración , Masculino , Femenino , Cromatografía Liquida/normas , Cromatografía Liquida/métodos , Sulfato de Deshidroepiandrosterona/sangre , Sulfato de Deshidroepiandrosterona/análisis , Sulfato de Deshidroepiandrosterona/normas , Persona de Mediana Edad , Cromatografía Líquida con Espectrometría de Masas
2.
Cureus ; 15(9): e44878, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37814730

RESUMEN

BACKGROUND: Salivary cortisol is a safe and non-invasive measure of hypothalamic-pituitary-adrenal axis function and is used as a biomarker of the human stress response. Natural environments are recognized to contribute to help reduce the effect of stress. OBJECTIVE: To determine the feasibility of a salivary cortisol collection protocol for acute severely brain-injured patients, and to explore the influence of exposure to natural settings on salivary cortisol concentration as an index of stress level. METHODS: An exploratory study on 17 acute patients with severe brain injury was performed. We collected salivary samples in a closed hospital ward and a therapeutic garden at the start of the session and after 30 minutes of rest time. Physiological parameters, level of communication, and subjective well-being were also assessed. RESULTS: The primary objectives regarding the feasibility of the protocol were met overall. We found no significant differences in cortisol values when including the whole population. However, cortisol values were significantly higher in the indoor environment in patients with communication attempts. CONCLUSIONS: A salivary collection protocol with brain-injured patients in the acute phase is feasible and safe, and this type of measurement could pave the way for future research supporting the benefits of nature as an additional resource in their neurorehabilitation.

4.
Clin Chem Lab Med ; 61(1): 67-77, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36288389

RESUMEN

OBJECTIVES: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) panels that include glucocorticoid-related steroids are increasingly used to characterize and diagnose adrenal cortical diseases. Limited information is currently available about reproducibility of these measurements among laboratories. The aim of the study was to compare LC-MS/MS measurements of corticosterone, 11-deoxycortisol and cortisone at eight European centers and assess the performance after unification of calibration. METHODS: Seventy-eight patient samples and commercial calibrators were measured twice by laboratory-specific procedures. Results were obtained according to in-house and external calibration. We evaluated intra-laboratory and inter-laboratory imprecision, regression and agreement against performance specifications derived from 11-deoxycortisol biological variation. RESULTS: Intra-laboratory CVs ranged between 3.3 and 7.7%, 3.3 and 11.8% and 2.7 and 12.8% for corticosterone, 11-deoxycortisol and cortisone, with 1, 4 and 3 laboratories often exceeding the maximum allowable imprecision (MAI), respectively. Median inter-laboratory CVs were 10.0, 10.7 and 6.2%, with 38.5, 50.7 and 2.6% cases exceeding the MAI for corticosterone, 11-deoxycortisol and cortisone, respectively. Median laboratory bias vs. all laboratory-medians ranged from -5.6 to 12.3% for corticosterone, -14.6 to 12.4% for 11-deoxycortisol and -4.0 to 6.5% for cortisone, with few cases exceeding the total allowable error. Modest deviations were found in regression equations among most laboratories. External calibration did not improve 11-deoxycortisol and worsened corticosterone and cortisone inter-laboratory comparability. CONCLUSIONS: Method imprecision was variable. Inter-laboratory performance was reasonably good. However, cases with imprecision and total error above the acceptable limits were apparent for corticosterone and 11-deoxycortisol. Variability did not depend on calibration but apparently on imprecision, accuracy and specificity of individual methods. Tools for improving selectivity and accuracy are required to improve harmonization.


Asunto(s)
Cortisona , Humanos , Cromatografía Liquida/métodos , Cortodoxona , Corticosterona , Espectrometría de Masas en Tándem/métodos , Reproducibilidad de los Resultados
5.
ACS Sens ; 7(9): 2721-2731, 2022 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-36054907

RESUMEN

The dysregulation of the hormone cortisol is related to several pathological states, and its monitoring could help prevent severe stress, fatigue, and mental diseases. While wearable antibody-based biosensors could allow real-time and simple monitoring of antigens, an accurate and low-cost antibody-based cortisol detection through electrochemical methods is considerably challenging due to its low concentration and the high ionic strength of real biofluids. Here, a label-free and fast sensor for cortisol detection is proposed based on antibody-coated organic electrochemical transistors. The developed devices show unprecedented high sensitivities of 50 µA/dec for cortisol sensing in high-ionic-strength solutions with effective cortisol detection demonstrated with real human sweat. The sensing mechanism is analyzed through impedance spectroscopy and confirmed with electrical models. Compared to existing methods requiring bulky and expensive laboratory equipment, these wearable devices enable point-of-care cortisol detection in 5 min with direct sweat collection for personalized well-being monitoring.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Anticuerpos/análisis , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Humanos , Hidrocortisona/análisis , Sudor/química
6.
Clin Chem Lab Med ; 60(5): 726-739, 2022 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-35172417

RESUMEN

OBJECTIVES: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is recommended for measuring circulating steroids. However, assays display technical heterogeneity. So far, reproducibility of corticosteroid LC-MS/MS measurements has received scant attention. The aim of the study was to compare LC-MS/MS measurements of cortisol, 17OH-progesterone and aldosterone from nine European centers and assess performance according to external quality assessment (EQA) materials and calibration. METHODS: Seventy-eight patient samples, EQA materials and two commercial calibration sets were measured twice by laboratory-specific procedures. Results were obtained by in-house (CAL1) and external calibrations (CAL2 and CAL3). We evaluated intra and inter-laboratory imprecision, correlation and agreement in patient samples, and trueness, bias and commutability in EQA materials. RESULTS: Using CAL1, intra-laboratory CVs ranged between 2.8-7.4%, 4.4-18.0% and 5.2-22.2%, for cortisol, 17OH-progesterone and aldosterone, respectively. Trueness and bias in EQA materials were mostly acceptable, however, inappropriate commutability and target value assignment were highlighted in some cases. CAL2 showed suboptimal accuracy. Median inter-laboratory CVs for cortisol, 17OH-progesterone and aldosterone were 4.9, 11.8 and 13.8% with CAL1 and 3.6, 10.3 and 8.6% with CAL3 (all p<0.001), respectively. Using CAL1, median bias vs. all laboratory-medians ranged from -6.6 to 6.9%, -17.2 to 7.8% and -12.0 to 16.8% for cortisol, 17OH-progesterone and aldosterone, respectively. Regression lines significantly deviated from the best fit for most laboratories. Using CAL3 improved cortisol and 17OH-progesterone between-method bias and correlation. CONCLUSIONS: Intra-laboratory imprecision and performance with EQA materials were variable. Inter-laboratory performance was mostly within specifications. Although residual variability persists, adopting common traceable calibrators and RMP-determined EQA materials is beneficial for standardization of LC-MS/MS steroid measurements.


Asunto(s)
Hidrocortisona , Progesterona , Aldosterona , Calibración , Cromatografía Liquida/métodos , Humanos , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/métodos
7.
Sci Adv ; 7(6)2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33536224

RESUMEN

The microbiome-produced enzyme bile salt hydrolase (BSH) plays a central role in human health, but its function remains unclear due to the lack of suitable methods for measuring its activity. Here, we have developed a novel optical tool based on ultrasensitive bioluminescent imaging and demonstrated that this assay can be used for quick and cost-effective quantification of BSH activity across a broad range of biological settings including pure enzymes and bacteria, intact fecal slurries, and noninvasive imaging in live animals, as well as for the assessment of BSH activity in the entire gastrointestinal tract of mice and humans. Using this assay, we showed that certain types of prebiotics are capable of increasing BSH activity of the gut microbiota in vivo and successfully demonstrated potential application of this assay as a noninvasive diagnostic test to predict the clinical status of inflammatory bowel disease (IBD) patients.


Asunto(s)
Amidohidrolasas , Microbioma Gastrointestinal , Amidohidrolasas/análisis , Amidohidrolasas/química , Animales , Bacterias , Ácidos y Sales Biliares , Microbioma Gastrointestinal/fisiología , Humanos , Mediciones Luminiscentes/métodos , Ratones , Prebióticos
8.
Sci Rep ; 11(1): 1636, 2021 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-33452333

RESUMEN

Creatine is an organic compound used as fast phosphate energy buffer to recycle ATP, important in tissues with high energy demand such as muscle or brain. Creatine is taken from the diet or endogenously synthetized by the enzymes AGAT and GAMT, and specifically taken up by the transporter SLC6A8. Deficit in the endogenous synthesis or in the transport leads to Cerebral Creatine Deficiency Syndromes (CCDS). CCDS are characterized by brain creatine deficiency, intellectual disability with severe speech delay, behavioral troubles such as attention deficits and/or autistic features, and epilepsy. Among CCDS, the X-linked creatine transporter deficiency (CTD) is the most prevalent with no efficient treatment so far. Different mouse models of CTD were generated by doing long deletions in the Slc6a8 gene showing reduced brain creatine and cognitive deficiencies or impaired motor function. We present a new knock-in (KI) rat model of CTD holding an identical point mutation found in patients with reported lack of transporter activity. KI males showed brain creatine deficiency, increased urinary creatine/creatinine ratio, cognitive deficits and autistic-like traits. The Slc6a8Y389C KI rat fairly enriches the spectrum of CTD models and provides new data about the pathology, being the first animal model of CTD carrying a point mutation.


Asunto(s)
Encéfalo/metabolismo , Proteínas del Tejido Nervioso/genética , Proteínas de Transporte de Neurotransmisores en la Membrana Plasmática/genética , Animales , Secuencia de Bases , Conducta Animal , Peso Corporal , Encefalopatías Metabólicas Innatas/genética , Encefalopatías Metabólicas Innatas/patología , Creatina/sangre , Creatina/deficiencia , Creatina/genética , Modelos Animales de Enfermedad , Femenino , Técnicas de Sustitución del Gen , Genotipo , Humanos , Masculino , Memoria a Corto Plazo , Discapacidad Intelectual Ligada al Cromosoma X/genética , Discapacidad Intelectual Ligada al Cromosoma X/patología , Mutación Missense , Proteínas del Tejido Nervioso/química , Proteínas del Tejido Nervioso/metabolismo , Proteínas de Transporte de Neurotransmisores en la Membrana Plasmática/química , Proteínas de Transporte de Neurotransmisores en la Membrana Plasmática/deficiencia , Proteínas de Transporte de Neurotransmisores en la Membrana Plasmática/metabolismo , Ratas
9.
J Pharm Biomed Anal ; 175: 112756, 2019 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-31387028

RESUMEN

In the context of hormonal contraception and hormone replacement therapy (HRT), many women are exposed to exogenous hormones. Current use of hormonal contraception with combined ethinyl estradiol and different progestins bestows a breast cancer relative risk (RR) of 1.2- while combined HRT has a RR of 2. Although these exposures present an important public health issue, little is known about the effects of individual progestins on the breast and other tissues. Increasing availability of large scale biobanks, high throughput analyses and data management tools enable ever expanding, sophisticated population studies. In order to address the impact of distinct progestins on various health indicators, it is desirable to accurately quantify progestins in clinical samples. Here we have developed and validated a high resolution liquid chromatography mass spectrometry (LC-MS) targeted method for the simultaneous quantification of 11 synthetic progestins widely used in oral contraceptives, gestodene, levonorgestrel, etonogestrel, chlormadinone acetate, cyproterone acetate, drospirenone, desacetyl norgestimate, medroxyprogesterone acetate, norethindrone, dienogest, nomegestrol acetate, and 4 endogenous steroid hormones, progesterone, testosterone, androstenedione, and cortisol in blood samples. This highly specific quantitative analysis with high resolution Orbitrap technology detects and quantifies 15 compounds using their internal standard counterparts in a single 12 min LC-MS run. Sensitivity is attained by the use of the instrument in targeted selected ion monitoring mode. Lower limit of quantitation ranges from 2.4 pg/ml for drospirenone to 78.1 pg/ml for chlormadinone acetate. The method provides comprehensive progestin panel measurements with as little as 50 µl of murine or human plasma.


Asunto(s)
Anticonceptivos/química , Progestinas/química , Esteroides/química , Animales , Cromatografía Liquida/métodos , Femenino , Humanos , Ratones , Ratones Endogámicos NOD , Espectrometría de Masas en Tándem/métodos
10.
Am J Physiol Endocrinol Metab ; 315(5): E833-E847, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29944388

RESUMEN

ß-Klotho (encoded by Klb) is an obligate coreceptor, mediating both fibroblast growth factor (FGF)15 and FGF21 signaling. Klb-/- mice are refractory to metabolic FGF15 and FGF21 action and exhibit derepressed (increased) bile acid (BA) synthesis. Here, we deeply phenotyped male Klb-/- mice on a pure C57BL/6J genetic background, fed a chow diet focusing on metabolic aspects. This aims to better understand the physiological consequences of concomitant FGF15 and FGF21 signaling deficiency, in particular on the gut-liver axis. Klb-/- mice present permanent growth restriction independent of adiposity and energy balance. Klb-/- mice also exhibit few changes in carbohydrate metabolism, combining normal gluco-tolerance, insulin sensitivity, and fasting response with increased gluconeogenic capacity and decreased glycogen mobilization. Livers of Klb-/- mice reveal pathologic features, including a proinflammatory status and initiation of fibrosis. These defects are associated to a massive shift in BA composition in the enterohepatic system and blood circulation featured by a large excess of microbiota-derived deoxycholic acid, classically known for its genotoxicity in the gastrointestinal tract. In conclusion, ß-Klotho is a gatekeeper of hepatic integrity through direct action (mediating FGF21 anti-inflammatory signaling) and indirect mechanisms (mediating FGF15 signaling that maintains BA level and composition).


Asunto(s)
Ácidos y Sales Biliares/metabolismo , Peso Corporal/fisiología , Tracto Gastrointestinal/metabolismo , Cirrosis Hepática/metabolismo , Hígado/metabolismo , Proteínas de la Membrana/metabolismo , Adiposidad/genética , Animales , Metabolismo Energético/genética , Factores de Crecimiento de Fibroblastos/metabolismo , Gluconeogénesis/fisiología , Cuerpos Cetónicos/sangre , Proteínas Klotho , Proteínas de la Membrana/genética , Ratones , Ratones Noqueados , Transducción de Señal/fisiología
11.
NPJ Syst Biol Appl ; 3: 33, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29138692

RESUMEN

The gut microbiome and lipid metabolism are both recognized as essential components in the maintenance of metabolic health. The mechanisms involved are multifactorial and (especially for microbiome) poorly defined. A strategic approach to investigate the complexity of the microbial influence on lipid metabolism would facilitate determination of relevant molecular mechanisms for microbiome-targeted therapeutics. E. coli is associated with obesity and metabolic syndrome and we used this association in conjunction with gnotobiotic models to investigate the impact of E. coli on lipid metabolism. To address the complexities of the integration of the microbiome and lipid metabolism, we developed transcriptomics-driven lipidomics (TDL) to predict the impact of E. coli colonization on lipid metabolism and established mediators of inflammation and insulin resistance including arachidonic acid metabolism, alterations in bile acids and dietary lipid absorption. A microbiome-related therapeutic approach targeting these mechanisms may therefore provide a therapeutic avenue supporting maintenance of metabolic health.

12.
JCI Insight ; 2(8)2017 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-28422755

RESUMEN

ß-Klotho (encoded by Klb) is the obligate coreceptor mediating FGF21 and FGF15/19 signaling. Klb-/- mice are refractory to beneficial action of pharmacological FGF21 treatment including stimulation of glucose utilization and thermogenesis. Here, we investigated the energy homeostasis in Klb-/- mice on high-fat diet in order to better understand the consequences of abrogating both endogenous FGF15/19 and FGF21 signaling during caloric overload. Surprisingly, Klb-/- mice are resistant to diet-induced obesity (DIO) owing to enhanced energy expenditure and BAT activity. Klb-/- mice exhibited not only an increase but also a shift in bile acid (BA) composition featured by activation of the classical (neutral) BA synthesis pathway at the expense of the alternative (acidic) pathway. High hepatic production of cholic acid (CA) results in a large excess of microbiota-derived deoxycholic acid (DCA). DCA is specifically responsible for activating the TGR5 receptor that stimulates BAT thermogenic activity. In fact, combined gene deletion of Klb and Tgr5 or antibiotic treatment abrogating bacterial conversion of CA into DCA both abolish DIO resistance in Klb-/- mice. These results suggested that DIO resistance in Klb-/- mice is caused by high levels of DCA, signaling through the TGR5 receptor. These data also demonstrated that gut microbiota can regulate host thermogenesis via conversion of primary into secondary BA. Pharmacologic or nutritional approaches to selectively modulate BA composition may be a promising target for treating metabolic disorders.

13.
J Clin Endocrinol Metab ; 99(11): 4328-35, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25137421

RESUMEN

OBJECTIVE: Prior to the implementation of the blood steroidal module of the Athlete Biological Passport, we measured the serum androgen levels among a large population of high-level female athletes as well as the prevalence of biochemical hyperandrogenism and some disorders of sex development (DSD). METHODS AND RESULTS: In 849 elite female athletes, serum T, dehydroepiandrosterone sulphate, androstenedione, SHBG, and gonadotrophins were measured by liquid chromatography-mass spectrometry high resolution or immunoassay. Free T was calculated. The sampling hour, age, and type of athletic event only had a small influence on T concentration, whereas ethnicity had not. Among the 85.5% that did not use oral contraceptives, 168 of 717 athletes were oligo- or amenorrhoic. The oral contraceptive users showed the lowest serum androgen and gonadotrophin and the highest SHBG concentrations. After having removed five doped athletes and five DSD women from our population, median T and free T values were close to those reported in sedentary young women. The 99th percentile for T concentration was calculated at 3.08 nmol/L, which is below the 10 nmol/L threshold used for competition eligibility of hyperandrogenic women with normal androgen sensitivity. Prevalence of hyperandrogenic 46 XY DSD in our athletic population is approximately 7 per 1000, which is 140 times higher than expected in the general population. CONCLUSION: This is the first study to establish normative serum androgens values in elite female athletes, while taking into account the possible influence of menstrual status, oral contraceptive use, type of athletic event, and ethnicity. These findings should help to develop the blood steroidal module of the Athlete Biological Passport and to refine more evidence-based fair policies and recommendations concerning hyperandrogenism in female athletes.


Asunto(s)
Androstenodiona/sangre , Atletas , Sulfato de Deshidroepiandrosterona/sangre , Hiperandrogenismo/epidemiología , Testosterona/sangre , Adolescente , Adulto , Femenino , Humanos , Hiperandrogenismo/sangre , Ciclo Menstrual/sangre , Persona de Mediana Edad , Prevalencia , Globulina de Unión a Hormona Sexual/metabolismo , Adulto Joven
14.
Anal Biochem ; 455: 20-5, 2014 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-24708936

RESUMEN

The discrepancy of results for the quantification of androstenedione in human serum between a radioimmunoassay (RIA) method and high performance liquid chromatography tandem-mass spectrometry (LC-MS/MS) was investigated. RIA overestimated concentrations compared to LC-MS/MS on 59 clinical samples (RIA=1.79×LC-MS/MS+0.94). RIA kit and LC-MS/MS calibrants were also determined by both methods. The RIA performed with improved accuracy on the calibrants (RIA=1.35×LC-MS/MS-0.28). Lipid, protein, electrolyte content, and pH of the two sets of calibrants were further investigated. The RIA calibrants contained little lipid material, while the LC-MS/MS calibrant material contained the same levels expected in normal serum/plasma. The pH and sex hormone binding globulin (SHBG) values were different between the RIA calibrants and the LC-MS/MS calibrant material (SHBG, 31±2 and 38±2nmol/l; pH, 8.27±0.18 and 8.66±0.03, respectively). No correlation was observed between androstenedione RIA and LC-MS/MS discrepancy and lipid or protein. LC-MS/MS sample preparation was tested for the removal of protein-bound material and recovery determined (99-108%). The corresponding RIA results overestimated androstenedione by 52-174% compared to LC-MS/MS. The results here demonstrate that LC-MS/MS is the more accurate method.


Asunto(s)
Androstenodiona/sangre , Cromatografía Líquida de Alta Presión/métodos , Radioinmunoensayo/métodos , Espectrometría de Masas en Tándem/métodos , Calibración , Humanos , Concentración de Iones de Hidrógeno , Globulina de Unión a Hormona Sexual/análisis
15.
J Nutr ; 143(6): 766-73, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23616503

RESUMEN

Epidemiological studies consistently find that diets rich in whole-grain (WG) cereals lead to decreased risk of disease compared with refined grain (RG)-based diets. Aside from a greater amount of fiber and micronutrients, possible mechanisms for why WGs may be beneficial for health remain speculative. In an exploratory, randomized, researcher-blinded, crossover trial, we measured metabolic profile differences between healthy participants eating a diet based on WGs compared with a diet based on RGs. Seventeen healthy adult participants (11 female, 6 male) consumed a controlled diet based on either WG-rich or RG-rich foods for 2 wk, followed by the other diet after a 5-wk washout period. Both diets were the same except for the use of WG (150 g/d) or RG foods. The metabolic profiles of plasma, urine, and fecal water were measured using (1)H-nuclear magnetic resonance spectroscopy and gas chromatography-mass spectrometry (plasma only). After 1 wk of intervention, the WG diet led to decreases in urinary excretion of metabolites related to protein catabolism (urea, methylguanadine), lipid (carnitine and acylcarnitines) and gut microbial (4-hydroxyphenylacetate, trimethylacetate, dimethylacetate) metabolism in men compared with the same time point during the RG intervention. There were no differences between the interventions after 2 wk. Urinary urea, carnitine, and acylcarnitine were lower at wk 1 of the WG intervention relative to the RG intervention in all participants. Fecal water short-chain fatty acids acetate and butyrate were relatively greater after the WG diet compared to the RG diet. Although based on a small population and for a short time period, these observations suggest that a WG diet may affect protein metabolism.


Asunto(s)
Biomarcadores/orina , Dieta , Grano Comestible , Intestinos/microbiología , Proteínas/metabolismo , Acetatos/análisis , Adulto , Bacterias/metabolismo , Biomarcadores/sangre , Carnitina/orina , Estudios Cruzados , Fibras de la Dieta , Metabolismo Energético , Heces/química , Femenino , Manipulación de Alimentos , Cromatografía de Gases y Espectrometría de Masas , Promoción de la Salud , Humanos , Metabolismo de los Lípidos , Espectroscopía de Resonancia Magnética , Masculino , Metaboloma , Metilaminas/análisis , Metilguanidina/orina , Persona de Mediana Edad , Ácidos Nicotínicos/análisis , Organofosfatos/análisis , Fenilacetatos/análisis , Factores Sexuales , Urea/orina
16.
Rapid Commun Mass Spectrom ; 27(1): 200-6, 2013 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-23239334

RESUMEN

RATIONALE: The aim of the work was to develop and validate a method for the quantification of vitamin D metabolites in serum using ultra-high-pressure liquid chromatography coupled to mass spectrometry (LC/MS), and to validate a high-resolution mass spectrometry (LC/HRMS) approach against a tandem mass spectrometry (LC/MS/MS) approach using a large clinical sample set. METHODS: A fast, accurate and reliable method for the quantification of the vitamin D metabolites, 25-hydroxyvitamin D2 (25OH-D2) and 25-hydroxyvitamin D3 (25OH-D3), in human serum was developed and validated. The C3 epimer of 25OH-D3 (3-epi-25OH-D3) was also separated from 25OH-D3. The samples were rapidly prepared via a protein precipitation step followed by solid-phase extraction (SPE) using an HLB µelution plate. Quantification was performed using both LC/MS/MS and LC/HRMS systems. RESULTS: Recovery, matrix effect, inter- and intra-day reproducibility were assessed. Lower limits of quantification (LLOQs) were determined for both 25OH-D2 and 25OH-D3 for the LC/MS/MS approach (6.2 and 3.4 µg/L, respectively) and the LC/HRMS approach (2.1 and 1.7 µg/L, respectively). A Passing & Bablok fit was determined between both approaches for 25OH-D3 on 662 clinical samples (1.11 + 1.06x). It was also shown that results can be affected by the inclusion of the isomer 3-epi-25OH-D3. CONCLUSIONS: Quantification of the relevant vitamin D metabolites was successfully developed and validated here. It was shown that LC/HRMS is an accurate, powerful and easy to use approach for quantification within clinical laboratories. Finally, the results here suggest that it is important to separate 3-epi-25OH-D3 from 25OH-D3.


Asunto(s)
25-Hidroxivitamina D 2/sangre , Calcifediol/sangre , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Humanos , Modelos Lineales , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
J Nutr ; 142(10): 1859-64, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22955514

RESUMEN

Alkylresorcinols (AR) are phenolic lipids found in the bran fraction of whole-grain wheat, rye, and barley. In intervention studies, plasma AR concentration increased in response to greater intakes of whole grain, wheat, and rye. This study examined the cross-sectional associations between plasma AR and habitual whole-grain intake, BMI, and metabolic risk factors in 407 free-living older adults (166 men and 241 women; aged 60-81y; median BMI: 27 kg/m(2)). Plasma AR were measured by liquid chromatography-tandem MS, and whole-grain intakes were estimated by using an FFQ. After adjustment for fasting TG concentrations, median plasma AR concentrations across quartile categories of AR were 5, 14, 27, and 62 nmol/L, respectively. Spearman correlation coefficients between plasma AR and whole-grain wheat-rich foods and total bran intake were 0.31 and 0.27, respectively (both P < 0.0001). After adjustment for multiple covariates, the geometric means of BMI in the lowest and highest quartile category of plasma AR were 27.6 and 26.7 kg/m(2), respectively (P-trend = 0.04). No associations were observed between plasma AR and glucose and insulin. Our study shows a dose-dependent relationship between whole-grain intake and plasma AR and confirms the previously observed inverse relationship between whole-grain intake and BMI using an independent biomarker of whole-grain wheat intake.


Asunto(s)
Biomarcadores/sangre , Índice de Masa Corporal , Fibras de la Dieta/administración & dosificación , Grano Comestible/química , Conducta Alimentaria , Resorcinoles/sangre , Anciano , Anciano de 80 o más Años , Composición Corporal , Estudios Transversales , Ingestión de Energía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo
18.
Med Sci Sports Exerc ; 44(1): 57-68, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21685813

RESUMEN

PURPOSE: This study aimed to determine the effect of postexercise protein-leucine coingestion with CHO-lipid on subsequent high-intensity endurance performance and to investigate candidate mechanisms using stable isotope methods and metabolomics. METHODS: In this double-blind, randomized, crossover study, 12 male cyclists ingested a leucine/protein/CHO/fat supplement (LEUPRO 7.5/20/89/22 g · h(-1), respectively) or isocaloric CHO/fat control (119/22 g · h(-1)) 1-3 h after exercise during a 6-d training block (intense intervals, recovery, repeated-sprint performance rides). Daily protein intake was clamped at 1.9 g · kg(-1) · d(-1) (LEUPRO) and 1.5 g · kg(-1) · d(-1) (control). Stable isotope infusions (1-(13)C-leucine and 6,6-(2)H2-glucose), mass spectrometry-based metabolomics, and nitrogen balance methods were used to determine the effects of LEUPRO on whole-body branched-chain amino acid (BCAA) and glucose metabolism and protein turnover. RESULTS: After exercise, LEUPRO increased BCAA levels in plasma (2.6-fold; 90% confidence limits = ×/÷ 1.1) and urine (2.8-fold; ×/÷ 1.2) and increased products of BCAA metabolism plasma acylcarnitine C5 (3.0-fold; ×/÷ 0.9) and urinary leucine (3.6-fold; ×/÷ 1.3) and ß-aminoisobutyrate (3.4-fold; ×/÷ 1.4), indicating that ingesting ~10 g leucine per hour during recovery exceeds the capacity to metabolize BCAA. Furthermore, LEUPRO increased leucine oxidation (5.6-fold; ×/÷ 1.1) and nonoxidative disposal (4.8-fold; ×/÷ 1.1) and left leucine balance positive relative to control. With the exception of day 1 (LEUPRO = 17 ± 20 mg N · kg(-1), control = -90 ± 44 mg N · kg(-1)), subsequent (days 2-5) nitrogen balance was positive for both conditions (LEUPRO = 130 ± 110 mg N · kg(-1), control = 111 ± 86 mg N · kg(-1)). Compared with control feeding, LEUPRO lowered the serum creatine kinase concentration by 21%-25% (90% confidence limits = ± 14%), but the effect on sprint power was trivial (day 4 = 0.4% ± 1.0%, day 6 = -0.3% ± 1.0%). CONCLUSIONS: Postexercise protein-leucine supplementation saturates BCAA metabolism and attenuates tissue damage, but effects on subsequent intense endurance performance may be inconsequential under conditions of positive daily nitrogen balance.


Asunto(s)
Aminoácidos de Cadena Ramificada/metabolismo , Rendimiento Atlético/fisiología , Proteínas en la Dieta/administración & dosificación , Suplementos Dietéticos , Leucina/administración & dosificación , Nitrógeno/metabolismo , Adulto , Aminoácidos de Cadena Ramificada/sangre , Aminoácidos de Cadena Ramificada/orina , Ácidos Aminoisobutíricos/orina , Creatina Quinasa/sangre , Estudios Cruzados , Carbohidratos de la Dieta/administración & dosificación , Carbohidratos de la Dieta/metabolismo , Proteínas en la Dieta/metabolismo , Método Doble Ciego , Humanos , Leucina/metabolismo , Leucina/orina , Masculino , Persona de Mediana Edad , Fuerza Muscular/efectos de los fármacos , Fuerza Muscular/fisiología , Músculo Esquelético/efectos de los fármacos , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiología , Consumo de Oxígeno/fisiología , Carrera/fisiología
19.
Br J Nutr ; 105(10): 1492-502, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21272402

RESUMEN

Epidemiological studies have repeatedly found that whole-grain (WG) cereal foods reduce the risk of several lifestyle-related diseases, though consistent clinical outcomes and mechanisms are elusive. To compare the effects of a WG-rich diet with a matched refined-grain (RG) diet on plasma biomarkers and bowel health parameters, seventeen healthy subjects (eleven females and six males) completed an exploratory cross-over study with a 2-week intervention diet based on either WG- or RG-based foods, separated by a washout of at least 5 weeks. Both diets were the same except for the use of WG (150 g/d) or RG foods. Subjects undertook a 4 h postprandial challenge on day 8 of each intervention diet. After 2 weeks, the WG diet tended to decrease plasma total and LDL-cholesterol (both P = 0·09), but did not change plasma HDL-cholesterol, fasting glucose, C-reactive protein or homocysteine compared with the RG diet. Plasma betaine and alkylresorcinol concentrations were elevated after 1 week of the WG diet (P = 0·01 and P < 0·0001, respectively). Clostridium leptum populations in faeces were increased after the WG diet, along with a trend for decreased faecal water pH (P = 0·096) and increased stool frequency (P < 0·0001) compared with the RG diet. A short controlled intervention trial with a variety of commercially available WG-based products tended to improve biomarkers of CVD compared with a RG diet. Changes in faecal microbiota related to increased fibre fermentation and increased plasma betaine concentrations point to both fibre and phytochemical components of WG being important in mediating any potential health effects.


Asunto(s)
Betaína/sangre , LDL-Colesterol/sangre , Fibras de la Dieta/administración & dosificación , Grano Comestible , Adulto , Cromatografía Líquida de Alta Presión , Estudios Cruzados , Femenino , Humanos , Masculino , Cooperación del Paciente , Valores de Referencia , Espectrometría de Masas en Tándem
20.
Biomarkers ; 16(1): 83-8, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21114379

RESUMEN

BACKGROUND: Predictive disease risk biomarkers that can be linked to exposure have proved difficult to identify in case-control studies. METHODS: Parallel statistical analysis of the correlation between (1)H NMR profiles from plasma samples collected before disease onset (EPIC cohort), versus exposure to dietary compounds, and follow-up disease endpoints (colon and breast cancer) was performed. RESULTS: Metabonomic signatures associated with colon cancer and dietary fiber intake (a protective factor according to epidemiological studies) were identified. CONCLUSION: This implementation of the novel "meet-in-the-middle" analytical strategy indicates how case-control studies nested in prospectively collected cohorts may reveal intermediate biomarkers linking exposure and disease.


Asunto(s)
Biomarcadores/sangre , Estudios de Cohortes , Diseño de Investigaciones Epidemiológicas , Metaboloma , Biomarcadores/análisis , Neoplasias de la Mama/sangre , Neoplasias de la Mama/epidemiología , Estudios de Casos y Controles , Neoplasias del Colon/sangre , Neoplasias del Colon/epidemiología , Dieta/estadística & datos numéricos , Fibras de la Dieta/administración & dosificación , Fibras de la Dieta/estadística & datos numéricos , Proteínas en la Dieta/administración & dosificación , Femenino , Humanos , Espectroscopía de Resonancia Magnética , Epidemiología Molecular , Plasma/química , Factores de Riesgo , Fumar/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA