Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Semin Arthritis Rheum ; 65: 152406, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38401294

RESUMEN

OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.


Asunto(s)
Técnica Delphi , Enfermedades Pulmonares Intersticiales , Ultrasonografía , Humanos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Ultrasonografía/normas , Reproducibilidad de los Resultados , Pulmón/diagnóstico por imagen , Consenso
2.
Ann Rheum Dis ; 82(4): 556-564, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36600183

RESUMEN

OBJECTIVES: To develop an Outcome Measures in Rheumatology (OMERACT) ultrasonography score for monitoring disease activity in giant cell arteritis (GCA) and evaluate its metric properties. METHODS: The OMERACT Instrument Selection Algorithm was followed. Forty-nine members of the OMERACT ultrasonography large vessel vasculitis working group were invited to seven Delphi rounds. An online reliability exercise was conducted using images of bilateral common temporal arteries, parietal and frontal branches as well as axillary arteries from 16 patients with GCA and 7 controls. Sensitivity to change and convergent construct validity were tested using data from a prospective cohort of patients with new GCA in which ultrasound-based intima-media thickness (IMT) measurements were conducted at weeks 1, 3, 6, 12 and 24. RESULTS: Agreement was obtained (92.7%) for the OMERACT GCA Ultrasonography Score (OGUS), calculated as follows: sum of IMT measured in every segment divided by the rounded cut-off values of IMTs in each segment. The resulting value is then divided by the number of segments available. Thirty-five members conducted the reliability exercise, the interrater intraclass correlation coefficient (ICC) for the OGUS was 0.72-0.84 and the median intrareader ICC was 0.91. The prospective cohort consisted of 52 patients. Sensitivity to change between baseline and each follow-up visit up to week 24 yielded standardised mean differences from -1.19 to -2.16, corresponding to large and very large magnitudes of change, respectively. OGUS correlated moderately with erythrocyte sedimentation rate, C reactive protein and Birmingham Vasculitis Activity Score (corrcoeff 0.37-0.48). CONCLUSION: We developed a provisional OGUS for potential use in clinical trials.


Asunto(s)
Arteritis de Células Gigantes , Humanos , Arteritis de Células Gigantes/diagnóstico por imagen , Grosor Intima-Media Carotídeo , Reproducibilidad de los Resultados , Estudios Prospectivos , Arterias Temporales/diagnóstico por imagen , Ultrasonografía/métodos
3.
Rheumatology (Oxford) ; 60(11): 5239-5246, 2021 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-33682887

RESUMEN

OBJECTIVES: Suboptimal medication adherence is a serious problem in the treatment of chronic inflammatory diseases. To measure medication adherence, electronic monitoring is regarded as superior to pill count. GLORIA is an ongoing two-year trial on the addition of low-dose (5 mg/d) prednisolone or placebo to standard care in older people (65+ years) with RA. During the entire trial, adherence is measured with electronic caps, and with pill counts. The objective is to describe medication adherence patterns, and to compare the adherence results of the two methods. METHODS: The recorded adherence patterns of patients (blinded for treatment group) were classified according to descriptive categories. The cutoff for good adherence was set at 80% of prescribed pills taken. RESULTS: Trial inclusion closed in 2018 at 451 patients, but trial follow-up is ongoing; the current dataset contains adherence data of 371 patients. Mean number of recorded 90-day periods per patient was 4 (range 1-8). Based on pill count over all periods, 90% of the patients had good adherence; based on cap data, only 20%. Cap data classified 30% of patients as non-user (<20% of days an opening) and 40% as irregular user (different adherence patterns, in or between periods). CONCLUSION: In our trial of older people with RA, the majority appeared to be adherent to medication according to pill count. Results from caps conflicted with those of pill counts, with patterns suggesting patients did not use the bottle for daily dispensing, despite specific advice to do so. TRIAL REGISTRATION: NCT02585258. ClinicalTrials.gov (https://www.clinicaltrials.gov/).


Asunto(s)
Artritis Reumatoide/tratamiento farmacológico , Embalaje de Medicamentos/estadística & datos numéricos , Glucocorticoides/uso terapéutico , Cumplimiento de la Medicación/estadística & datos numéricos , Prednisolona/uso terapéutico , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino
4.
Semin Arthritis Rheum ; 51(3): 661-676, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33386164

RESUMEN

AIMS: To analyze whether there is sufficient data from published literature to demonstrate that ultrasound, including elastography, present good metric properties (truth, discrimination and feasibility) in autoimmune myositis (AIM). METHODS: A population, intervention, comparator and outcome-structured (PICO) search was performed in Medline, Cochrane Library and Embase database from 01/01/1973 to 08/05/2019. The inclusion criteria required original research involving adult humans, reported in English, assessing ultrasound and elastography in patients with an AIM. Conference abstracts and computer-assisted diagnostics that focused on technique and not ultrasound domains were excluded. RESULTS: Approximately 2670 articles were identified. Forty-one full-text articles were included in the final analysis. There were 551 AIM patients studied. Eighteen studies (43.9%) had a control group, of which 15 (63.3%) were healthy controls. The age of participants (including controls) varied from 18 to 86 years, and most were females (59%). Diagnosis of AIM was largely biopsy-proven, although some were derived through clinical presentation, positive clinical imaging (ultrasound or otherwise) and/or electromyography and steroid responsiveness. The features examined with ultrasound in the 41 included articles consisted of: muscle echogenicity, bulk, atrophy, architecture, power Doppler, perfusion characteristics, shear wave modulus, shear wave velocity, elasticity index and fasciculations. Twelve studies (29.2%) used quantitative methods to assess these characteristics, whilst others used semi-quantitative, dichotomous/binary and descriptive scoring systems. Criterion validity was met in 14 studies (12/14, 85.7%) and construct validity in 22 studies (22/25, 88.0%). Most published articles reported Level 3b to Level 5 evidence with varying degrees of bias. There was only one longitudinal study examining discrimination. Reliability and feasibility were under-reported. CONCLUSION: This is the first systematic review studying the utility of ultrasound, including elastography, in AIM. There is some evidence for criterion and construct validity, suggesting that ultrasound may be a promising outcome measurement instrument in AIM. Agreement on the standardization of acquisition, and the definitions of target domains, is required. Additionally, further validation studies are required to determine discrimination, reliability and feasibility.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Miositis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Estudios Longitudinales , Persona de Mediana Edad , Miositis/diagnóstico por imagen , Reproducibilidad de los Resultados , Ultrasonografía , Adulto Joven
6.
RMD Open ; 6(1)2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-32396518

RESUMEN

OBJECTIVES: To evaluate the sensitivity to change of ultrasound structural gout lesions, as defined by the Outcome Measures in Rheumatology (OMERACT) ultrasound group, in patients with gout during urate-lowering therapy (ULT). METHODS: Ultrasound (28 joints, 26 tendons) was performed in patients with microscopically verified gout initiating or increasing ULT and repeated after 3 and 6 months. Joints and tendons were evaluated by ultrasound for presence of the OMERACT structural gout lesions-double contour sign (DC), tophus, aggregates and erosion-scored binarily. A sum score was calculated at patient and lesion level. Changes at 3 and 6 months in patient sum scores and lesion scores at different locations were evaluated. RESULTS: 50 patients (48 men), mean age 68.9 (range, 30-88) years, were included. Ultrasound showed a statistically significant decrease in DC and tophus sum scores from 0 months (3.16 and 2.68, respectively) to 3 months (2.33 and 2.43) and 6 months (1.34 and 1.83) (all p<0.002). The aggregate sum score only decreased significantly from 3 to 6 months (6.02 to 5.02, p=0.002), whereas erosion sum score remained almost unchanged. All four structural lesions were most commonly found in metatarsophalangeal (MTP) 1 joints (>1 lesions bilaterally), and furthermore MTP2-4 and knee joints were common sites especially for DC. Likewise, these regions were the locations with most pronounced changes in scores. CONCLUSION: Ultrasound assessment of the OMERACT structural gout lesions scored binarily seems to be a useful tool for monitoring urate depositions during ULT. Particularly DC and tophus showed sensitivity to change after only 3 months of treatment.


Asunto(s)
Gota/diagnóstico por imagen , Evaluación de Resultado en la Atención de Salud , Ultrasonografía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Articulaciones/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Sistema Musculoesquelético/química , Valor Predictivo de las Pruebas , Estudios Prospectivos , Tendones/diagnóstico por imagen , Ácido Úrico/análisis
7.
Arthritis Care Res (Hoboken) ; 72(4): 498-506, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-28777893

RESUMEN

OBJECTIVE: To determine the intra- and interobserver reliability of ultrasound (US)-detected age-related joint vascularization and ossification grading in healthy children. METHODS: Following standardized image acquisition and machine setting protocols, 10 international US experts examined 4 joints (wrist, second metacarpophalangeal joint, knee, and ankle) in 12 healthy children (divided into 4 age groups: 2-4, 5-8, 9-12, and 13-16 years). Gray-scale was used to detect the ossification grade, and power Doppler ultrasound (PDUS) was used to detect physiologic vascularization. Ossification was graded from 0 (no ossification) to 3 (complete ossification). A positive PDUS signal was defined as any PDUS signal inside the joint. Kappa statistics were applied for intra- and interobserver reliability. RESULTS: According to the specific joint and age, up to 4 solitary PDUS signals (mean 1.5) were detected within each joint area with predominant localization of the physiologic vascularization in specific anatomic positions: fat pad, epiphysis, physis, and short bone cartilage. The kappa values for ossification grading were 0.87 (range 0.85-0.91) and 0.58 for intra- and interobserver reliability, respectively. The bias-adjusted kappa values for intra- and interobserver reliability were 0.71 (range 0.44-1.00) and 0.69, respectively. CONCLUSION: Detection of normal findings (i.e., grading of physiologic ossification during skeletal maturation and identification of physiologic vessels) can be highly reliable by using clear definitions and a standardized acquisition protocol. These data will permit development of a reliable and standardized US approach for evaluating pediatric joint pathologies.


Asunto(s)
Articulaciones/diagnóstico por imagen , Neovascularización Fisiológica/fisiología , Osteogénesis/fisiología , Ultrasonografía Doppler/métodos , Adolescente , Niño , Preescolar , Femenino , Humanos , Masculino , Proyectos Piloto , Valores de Referencia , Reproducibilidad de los Resultados , Membrana Sinovial/diagnóstico por imagen
8.
Rheumatology (Oxford) ; 59(9): 2325-2333, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31859346

RESUMEN

OBJECTIVES: U-Act-Early was a 2-year, randomized placebo controlled, double-blind trial, in which DMARD-naïve early RA patients were treated to the target of sustained remission (SR). Two strategies initiating tocilizumab (TCZ), with and without methotrexate (MTX), were more effective than a strategy initiating MTX. The aim of the current study was to determine longer-term effectiveness in daily clinical practice. METHODS: At the end of U-Act-Early, patients were included in a 3-year post-trial follow-up (PTFU), in which treatment was according to standard care and data were collected every 3 months during the first year and every 6 months thereafter. Primary end point was disease activity score assessing 28 joints (DAS28) over time. Mixed effects models were used to compare effectiveness between initial strategy groups, correcting for relevant confounders. Between the groups as randomized, proportions of patients were tested for DMARD use, SR and radiographic progression of joint damage. RESULTS: Of patients starting U-Act-Early, 226/317 (71%) participated in the PTFU. Over the total 5 years, mean DAS28 was similar between groups (P > 0.20). During U-Act-Early, biologic DMARD use decreased in both TCZ initiation groups and increased in the MTX initiation group, but during follow-up this trend did not continue. SR was achieved at least once in 99% of patients. Of the 226 patients, only 30% had any radiographic progression over 5 years, without significant differences between the groups. CONCLUSION: Although in the short-term the strategies initiating TCZ yielded the most clinical benefit, in the longer-term differences in important clinical outcomes between the strategies disappeared, probably due to continuation of the treat-to-target principle.


Asunto(s)
Anticuerpos Monoclonales Humanizados/administración & dosificación , Antirreumáticos/administración & dosificación , Artritis Reumatoide/tratamiento farmacológico , Metotrexato/administración & dosificación , Factores de Tiempo , Adulto , Anciano , Artritis Reumatoide/patología , Progresión de la Enfermedad , Método Doble Ciego , Quimioterapia Combinada , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
9.
J Ultrason ; 19(77): 125-127, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31355584

RESUMEN

Introduction: Surgical biopsy of minor salivary glands is routinely performed for the diagnosis of Sjögren syndrome. However, surgical biopsies of the minor labial glands may result in various complications in up to 6% of patients. On the other hand, adverse events following core needle biopsies of the parotid gland in non-rheumatological settings have been reported as very rare. Aim: The objective of this study was to assess the feasibility and determine the presence of parotid gland tissue in ultrasound-guided parotid gland biopsies performed by rheumatologists in cadavers. Material and method: Two senior rheumatologists obtained, under direct ultrasound visualization in in-plane technique, biopsies of 8 parotid glands from 4 different cadavers using a core biopsy needle. One biopsy per gland was taken. Results: All histological exams showed typical parotid gland tissue without any neuronal or vascular tissue. Conclusion: In conclusion, we demonstrated that minimally invasive, ultrasound-guided core needle biopsy of the parotid gland is a highly precise and easy method to obtain salivary gland tissue.Introduction: Surgical biopsy of minor salivary glands is routinely performed for the diagnosis of Sjögren syndrome. However, surgical biopsies of the minor labial glands may result in various complications in up to 6% of patients. On the other hand, adverse events following core needle biopsies of the parotid gland in non-rheumatological settings have been reported as very rare. Aim: The objective of this study was to assess the feasibility and determine the presence of parotid gland tissue in ultrasound-guided parotid gland biopsies performed by rheumatologists in cadavers. Material and method: Two senior rheumatologists obtained, under direct ultrasound visualization in in-plane technique, biopsies of 8 parotid glands from 4 different cadavers using a core biopsy needle. One biopsy per gland was taken. Results: All histological exams showed typical parotid gland tissue without any neuronal or vascular tissue. Conclusion: In conclusion, we demonstrated that minimally invasive, ultrasound-guided core needle biopsy of the parotid gland is a highly precise and easy method to obtain salivary gland tissue.

10.
Rheumatology (Oxford) ; 58(10): 1802-1811, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31034077

RESUMEN

OBJECTIVES: To develop and test the reliability of a new semiquantitative scoring system for the assessment of cartilage changes by ultrasound in a web-based exercise as well as a patient exercise of patients with RA. METHODS: A taskforce of the Outcome Measures in Rheumatology Ultrasound Working Group performed a systematic literature review on the US assessment of cartilage in RA, followed by a Delphi survey on cartilage changes and a new semiquantitative US scoring system, and finally a web-based exercise as well as a patient exercise. For the web-based exercise, taskforce members scored a dataset of anonymized static images of MCP joints in RA patients and healthy controls, which also contained duplicate images. Subsequently, 12 taskforce members used the same US to score cartilage in MCP and proximal interphalangeal joints of six patients with RA in in a patient reliability exercise. Percentage agreement and prevalence of lesions were calculated, as intrareader reliability was assessed by weighted kappa and interreader reliability by Light's kappa. RESULTS: The three-grade semiquantitative scoring system demonstrated excellent intrareader reliability (kappa: 0.87 and 0.83) in the web-based exercise and the patient exercise, respectively. Interreader reliability was good in the web-based exercise (kappa: 0.64) and moderate (kappa: 0.48) in the patient exercise. CONCLUSION: Our study demonstrates that ultrasound is a reliable tool for evaluating cartilage changes in the MCP joints of patients with RA and supports further development of a new reliable semiquantitative ultrasound scoring system for evaluating cartilage involvement in RA.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Cartílago/diagnóstico por imagen , Reumatología/métodos , Índice de Severidad de la Enfermedad , Ultrasonografía/estadística & datos numéricos , Adulto , Comités Consultivos , Técnica Delphi , Femenino , Humanos , Masculino , Articulación Metacarpofalángica/diagnóstico por imagen , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Ultrasonografía/métodos
11.
J Rheumatol ; 46(10): 1394-1400, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30877208

RESUMEN

OBJECTIVE: To describe the Outcome Measures in Rheumatology (OMERACT) stepwise approach to select and develop an imaging instrument with musculoskeletal ultrasound (US) as an example. METHODS: The OMERACT US Working Group (WG) developed a 4-step process to select instruments based on imaging. Step 1 applies the OMERACT Framework Instrument Selection Algorithm (OFISA) to existing US outcome measurement instruments for a specific indication. This step requires a literature review focused on the truth, discrimination, and feasibility aspects of the instrument for the target pathology. When the evidence is completely unsatisfactory, Step 2 is a consensus process to define the US characteristics of the target pathology including one or more so-called "elementary lesions". Step 3 applies the agreed definitions to the image, evaluates their reliability, develops a severity grading of the lesion(s) at a given anatomical site, and evaluates the effect of the acquisition technique on feasibility and lesion(s) detection. Step 4 applies and assesses the definition(s) and scoring system(s) in cross-sectional studies and multicenter trials. The imaging instrument is now ready to pass a final OFISA check. RESULTS: With this process in place, the US WG now has 18 subgroups developing US instruments in 10 different diseases. Half of them have passed Step 3, and the groups for enthesitis (spondyloarthritis, psoriatic arthritis), synovitis, and tenosynovitis (rheumatoid arthritis) have finished Step 4. CONCLUSION: The US WG approach to select and develop outcome measurement instruments based on imaging has been repeatedly and successfully applied in US, but is generic for imaging and fits with OMERACT Filter 2.1.


Asunto(s)
Sistema Musculoesquelético/diagnóstico por imagen , Evaluación de Resultado en la Atención de Salud/métodos , Reumatología/métodos , Artritis Psoriásica/diagnóstico por imagen , Artritis Reumatoide/diagnóstico por imagen , Consenso , Entesopatía/diagnóstico por imagen , Humanos , Sistema Musculoesquelético/patología , Proyectos de Investigación , Índice de Severidad de la Enfermedad , Sinovitis/diagnóstico por imagen , Tenosinovitis/diagnóstico por imagen , Ultrasonografía
12.
Rheumatology (Oxford) ; 58(6): 1040-1046, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30624693

RESUMEN

OBJECTIVES: To assess the prevalence of clinical, US and radiographic hip involvement in AS patients with active disease and to explore the associations between these assessments. Furthermore, to evaluate the effect of 6 months of TNF-α blocking therapy on tender and inflammatory power Doppler US lesions of hip joints. METHODS: Consecutive AS patients starting TNF-α blocking therapy were evaluated for hip joint involvement. At baseline, patient-reported history of hip involvement was assessed and radiographic evaluation (BASRI-hip) was performed. Clinical examination (tender hip joints) and US examination took place before and after 6 months of treatment. RESULTS: Of the 111 included patients, 20% reported a history of hip involvement. At baseline, tender hip joints were present in 23% of patients. US examination showed inflammatory lesions in 17% of patients, of which 74% had positive power Doppler. Structural lesions were present in 20% of patients, of which 55% had osteophytes. Structural radiographic damage was seen in 10% of patients. Highest concordance was found between history of hip involvement and radiographic hip involvement (phi coefficient 0.333). After 6 months of TNF-α blocking therapy, significant decrease was found in tender hip joints (from 29 to 11), total number of inflammatory US lesions (from 29 to 9) and positive power Doppler (from 22 to 6). CONCLUSION: The prevalence rate of hip involvement in AS patients varies from 10 to 23%, depending on the type of hip assessment. TNF-α blocking therapy significantly improved tender hip joints, and inflammatory US lesions including positive power Doppler.


Asunto(s)
Articulación de la Cadera/diagnóstico por imagen , Inflamación/diagnóstico por imagen , Espondilitis Anquilosante/diagnóstico por imagen , Espondilitis Anquilosante/tratamiento farmacológico , Inhibidores del Factor de Necrosis Tumoral/uso terapéutico , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Ultrasonografía Doppler
13.
J Rheumatol ; 46(4): 351-359, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30385707

RESUMEN

OBJECTIVE: To evaluate the intraobserver and interobserver reliability of the ultrasonographic (US) assessment of subtalar joint (STJ) synovitis in patients with rheumatoid arthritis (RA). METHODS: Following a Delphi process, 12 sonographers conducted an US reliability exercise on 10 RA patients with hindfoot pain. The anteromedial, posteromedial, and posterolateral STJ was assessed using B-mode and power Doppler (PD) techniques according to an agreed US protocol and using a 4-grade semiquantitative grading score for synovitis [synovial hypertrophy (SH) and signal] and a dichotomous score for the presence of joint effusion (JE). Intraobserver and interobserver reliability were computed by Cohen's and Light's κ. Weighted κ coefficients with absolute weighting were computed for B-mode and PD signal. RESULTS: Mean weighted Cohen's κ for SH, PD, and JE were 0.80 (95% CI 0.62-0.98), 0.61 (95% CI 0.48-0.73), and 0.52 (95% CI 0.36-0.67), respectively. Weighted Cohen's κ for SH, PD, and JE in the anteromedial, posteromedial, and posterolateral STJ were -0.04 to 0.79, 0.42-0.95, and 0.28-0.77; 0.31-1, -0.05 to 0.65, and -0.2 to 0.69; 0.66-1, 0.52-1, and 0.42-0.88, respectively. Weighted Light's κ for SH was 0.67 (95% CI 0.58-0.74), 0.46 (95% CI 0.35-0.59) for PD, and 0.16 (95% CI 0.08-0.27) for JE. Weighted Light's κ for SH, PD, and JE were 0.63 (95% CI 0.45-0.82), 0.33 (95% CI 0.19-0.42), and 0.09 (95% CI -0.01 to 0.19), for the anteromedial; 0.49 (95% CI 0.27-0.64), 0.35 (95% CI 0.27-0.4), and 0.04 (95% CI -0.06 to 0.1) for posteromedial; and 0.82 (95% CI 0.75-0.89), 0.66 (95% CI 0.56-0.8), and 0.18 (95% CI 0.04-0.34) for posterolateral STJ, respectively. CONCLUSION: Using a multisite assessment, US appears to be a reliable tool for assessing synovitis of STJ in RA.


Asunto(s)
Artritis Reumatoide/patología , Articulación Talocalcánea/diagnóstico por imagen , Articulación Talocalcánea/patología , Sinovitis/diagnóstico por imagen , Sinovitis/epidemiología , Ultrasonografía Doppler/métodos , Ultrasonografía Doppler/normas , Adulto , Consenso , Técnica Delphi , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Proyectos de Investigación
14.
Ann Rheum Dis ; 77(8): 1194-1199, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29535120

RESUMEN

OBJECTIVES: To assess the reliability of the OMERACT ultrasound (US) definitions for the identification of calcium pyrophosphate deposition disease (CPPD) at the metacarpal-phalangeal, triangular fibrocartilage of the wrist (TFC), acromioclavicular (AC) and hip joints. METHODS: A web-based exercise and subsequent patient-based exercise were carried out. A panel of 30 OMERACT members, participated at the web-based exercise by evaluating twice a set of US images for the presence/absence of CPPD. Afterwards, 19 members of the panel met in Siena, Italy, for the patient-based exercise. During the exercise, all sonographers examined twice eight patients for the presence/absence of CPPD at the same joints. Intraoberserver and interobserver kappa values were calculated for both exercises. RESULTS: The web-based exercise yielded high kappa values both in intraobserver and interobserver evaluation for all sites, while in the patient-based exercise, inter-reader agreement was acceptable for the TFC and the AC. TFC reached high interobserver and intraobserver k values in both exercises, ranging from 0.75 to 0.87 (good to excellent agreement). AC reached moderate kappa values, from 0.51 to 0.85 (moderate to excellent agreement) and can readily be used for US CPPD identification. CONCLUSIONS: Based on the results of our exercise, the OMERACT US definitions for the identification of CPPD demonstrated to be reliable when applied to the TFC and AC. Other sites reached good kappa values in the web-based exercise but failed to achieve good reproducibility at the patient-based exercise, meaning the scanning method must be further refined.


Asunto(s)
Condrocalcinosis/diagnóstico por imagen , Ultrasonografía/normas , Articulación Acromioclavicular/diagnóstico por imagen , Anciano , Femenino , Articulación de la Cadera/diagnóstico por imagen , Humanos , Cooperación Internacional , Internet , Masculino , Articulación Metacarpofalángica/diagnóstico por imagen , Persona de Mediana Edad , Variaciones Dependientes del Observador , Sistemas de Información Radiológica , Reproducibilidad de los Resultados , Ultrasonografía/métodos , Articulación de la Muñeca/diagnóstico por imagen
15.
RMD Open ; 3(1): e000427, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28948984

RESUMEN

OBJECTIVES: To test the reliability of new ultrasound (US) definitions and quantification of synovial hypertrophy (SH) and power Doppler (PD) signal, separately and in combination, in a range of joints in patients with rheumatoid arthritis (RA) using the European League Against Rheumatisms-Outcomes Measures in Rheumatology (EULAR-OMERACT) combined score for PD and SH. METHODS: A stepwise approach was used: (1) scoring static images of metacarpophalangeal (MCP) joints in a web-based exercise and subsequently when scanning patients; (2) scoring static images of wrist, proximal interphalangeal joints, knee and metatarsophalangeal joints in a web-based exercise and subsequently when scanning patients using different acquisitions (standardised vs usual practice). For reliability, kappa coefficients (κ) were used. RESULTS: Scoring MCP joints in static images showed substantial intraobserver variability but good to excellent interobserver reliability. In patients, intraobserver reliability was the same for the two acquisition methods. Interobserver reliability for SH (κ=0.87) and PD (κ=0.79) and the EULAR-OMERACT combined score (κ=0.86) were better when using a 'standardised' scan. For the other joints, the intraobserver reliability was excellent in static images for all scores (κ=0.8-0.97) and the interobserver reliability marginally lower. When using standardised scanning in patients, the intraobserver was good (κ=0.64 for SH and the EULAR-OMERACT combined score, 0.66 for PD) and the interobserver reliability was also good especially for PD (κ range=0.41-0.92). CONCLUSION: The EULAR-OMERACT score demonstrated moderate-good reliability in MCP joints using a standardised scan and is equally applicable in non-MCP joints. This scoring system should underpin improved reliability and consequently the responsiveness of US in RA clinical trials.

16.
Ann Rheum Dis ; 76(12): 1974-1979, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28814430

RESUMEN

BACKGROUND: In 2001, the European League Against Rheumatism developed and disseminated the first guidelines for musculoskeletal (MS) ultrasound (US) in rheumatology. Fifteen years later, the dramatic expansion of new data on MSUS in the literature coupled with technological developments in US imaging has necessitated an update of these guidelines. OBJECTIVES: To update the existing MSUS guidelines in rheumatology as well as to extend their scope to other anatomic structures relevant for rheumatology. METHODS: The project consisted of the following steps: (1) a systematic literature review of MSUS evaluable structures; (2) a Delphi survey among rheumatologist and radiologist experts in MSUS to select MS and non-MS anatomic structures evaluable by US that are relevant to rheumatology, to select abnormalities evaluable by US and to prioritise these pathologies for rheumatology and (3) a nominal group technique to achieve consensus on the US scanning procedures and to produce an electronic illustrated manual (ie, App of these procedures). RESULTS: Structures from nine MS and non-MS areas (ie, shoulder, elbow, wrist and hand, hip, knee, ankle and foot, peripheral nerves, salivary glands and vessels) were selected for MSUS in rheumatic and musculoskeletal diseases (RMD) and their detailed scanning procedures (ie, patient position, probe placement, scanning method and bony/other landmarks) were used to produce the App. In addition, US evaluable abnormalities present in RMD for each anatomic structure and their relevance for rheumatology were agreed on by the MSUS experts. CONCLUSIONS: This task force has produced a consensus-based comprehensive and practical framework on standardised procedures for MSUS imaging in rheumatology.


Asunto(s)
Enfermedades Musculoesqueléticas/diagnóstico por imagen , Enfermedades Reumáticas/diagnóstico por imagen , Reumatología/normas , Ultrasonografía/métodos , Ultrasonografía/normas , Consenso , Técnica Delphi , Europa (Continente) , Humanos
17.
J Rheumatol ; 44(11): 1740-1743, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28148700

RESUMEN

OBJECTIVE: To provide an update from the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group on the progress for defining ultrasound (US) minimal disease activity threshold at joint level in rheumatoid arthritis (RA) and for standardization of US application in juvenile idiopathic arthritis (JIA). METHODS: For minimal disease activity, healthy controls (HC) and patients with early arthritis (EA) who were naive to disease-modifying antirheumatic drugs were recruited from 2 centers. US was performed of the hands and feet, and scored semiquantitatively (0-3) for synovial hypertrophy (SH) and power Doppler (PD). Synovial effusion (SE) was scored a binary variable. For JIA, a Delphi approach and subsequent validation in static images and patient-based exercises were used to developed preliminary definitions for synovitis and a scoring system. RESULTS: For minimal disease activity, 7% HC had at least 1 joint abnormality versus 30% in the EA group. In HC, the findings of SH and PD were predominantly grade 1 whereas all grades were seen in the EA cohort, but SE was rare. In JIA, synovitis can be diagnosed based on B-mode findings alone because of the presence of physiological vascularization. A semiquantitative scoring system (0-3) for synovitis for both B-mode and Doppler were developed in which the cutoff between Doppler grade 2 and grade 3 was 30%. CONCLUSION: The first step has been taken to define the threshold for minimal disease activity in RA by US and to define and develop a scoring system for synovitis in JIA. Further steps are planned for the continuous validation of US in these areas.


Asunto(s)
Artritis Juvenil/diagnóstico por imagen , Artritis Reumatoide/diagnóstico por imagen , Articulaciones del Pie/diagnóstico por imagen , Articulaciones de la Mano/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Reumatología , Sensibilidad y Especificidad
18.
Lancet ; 388(10042): 343-355, 2016 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-27287832

RESUMEN

BACKGROUND: For patients with newly diagnosed rheumatoid arthritis, treatment aim is early, rapid, and sustained remission. We compared the efficacy and safety of strategies initiating the interleukin-6 receptor-blocking monoclonal antibody tocilizumab with or without methotrexate (a conventional synthetic disease-modifying antirheumatic drug [DMARD]), versus initiation of methotrexate monotherapy in line with international guidelines. METHODS: We did a 2-year, multicentre, randomised, double-blind, double-dummy, strategy study at 21 rheumatology outpatient departments in the Netherlands. We included patients who had been diagnosed with rheumatoid arthritis within 1 year before inclusion, were DMARD-naive, aged 18 years or older, met current rheumatoid arthritis classification criteria, and had a disease activity score assessing 28 joints (DAS28) of at least 2·6. We randomly assigned patients (1:1:1) to start tocilizumab plus methotrexate (the tocilizumab plus methotrexate arm), or tocilizumab plus placebo-methotrexate (the tocilizumab arm), or methotrexate plus placebo-tocilizumab (the methotrexate arm). Tocilizumab was given at 8 mg/kg intravenously every 4 weeks with a maximum of 800 mg per dose. Methotrexate was started at 10 mg per week orally and increased stepwise every 4 weeks by 5 mg to a maximum of 30 mg per week, until remission or dose-limiting toxicity. We did the randomisation using an interactive web response system. Masking was achieved with placebos that were similar in appearance to the active drug; the study physicians, pharmacists, monitors, and patients remained masked during the study, and all assessments were done by masked assessors. Patients not achieving remission on their initial regimen switched from placebo to active treatments; patients in the tocilizumab plus methotrexate arm switched to standard of care therapy (typically methotrexate combined with a tumour necrosis factor inhibitor). When sustained remission was achieved, methotrexate (and placebo-methotrexate) was tapered and stopped, then tocilizumab (and placebo-tocilizumab) was also tapered and stopped. The primary endpoint was the proportion of patients achieving sustained remission (defined as DAS28 <2·6 with a swollen joint count ≤four, persisting for at least 24 weeks) on the initial regimen and during the entire study duration, compared between groups with a two-sided Cochran-Mantel-Haenszel test. Analysis was based on an intention-to-treat method. This trial was registered at ClinicalTrials.gov, number NCT01034137. FINDINGS: Between Jan 13, 2010, and July 30, 2012, we recruited and assigned 317 eligible patients to treatment (106 to the tocilizumab plus methotrexate arm, 103 to the tocilizumab arm, and 108 to the methotrexate arm). The study was completed by a similar proportion of patients in the three groups (range 72-78%). The most frequent reasons for dropout were adverse events or intercurrent illness: 27 (34%) of dropouts, and insufficient response: 26 (33%) of dropouts. 91 (86%) of 106 patients in the tocilizumab plus methotrexate arm achieved sustained remission on the initial regimen, compared with 86 (84%) of 103 in the tocilizumab arm, and 48 (44%) of 108 in the methotrexate arm (relative risk [RR] 2·00, 95% CI 1·59-2·51 for tocilizumab plus methotrexate vs methotrexate, and 1·86, 1·48-2·32 for tocilizumab vs methotrexate, p<0·0001 for both comparisons). For the entire study, 91 (86%) of 106 patients in the tocilizumab plus methotrexate arm, 91 (88%) of 103 in the tocilizumab arm, and 83 (77%) of 108 in the methotrexate arm achieved sustained remission (RR 1·13, 95% CI 1·00-1·29, p=0·06 for tocilizumab plus methotrexate vs methotrexate, 1·14, 1·01-1·29, p=0·0356 for tocilizumab vs methotrexate, and p=0·59 for tocilizumab plus methotrexate vs tocilizumab). Nasopharyngitis was the most common adverse event in all three treatment groups, occurring in 38 (36%) of 106 patients in the tocilizumab plus methotrexate arm, 40 (39%) of 103 in the tocilizumab arm, and 37 (34%) of 108 in the methotrexate arm. The occurrence of serious adverse events did not differ between the treatment groups (17 [16%] of 106 patients in the tocilizumab plus methotrexate arm vs 19 [18%] of 103 in the tocilizumab arm and 13 [12%] of 108 in the methotrexate arm), and no deaths occurred during the study. INTERPRETATION: For patients with newly diagnosed rheumatoid arthritis, strategies aimed at sustained remission by immediate initiation of tocilizumab with or without methotrexate are more effective, and with a similar safety profile, compared with initiation of methotrexate in line with current standards. FUNDING: Roche Nederland BV.


Asunto(s)
Anticuerpos Monoclonales Humanizados/uso terapéutico , Antirreumáticos/uso terapéutico , Artritis Reumatoide/tratamiento farmacológico , Metotrexato/uso terapéutico , Adulto , Anticuerpos Monoclonales Humanizados/efectos adversos , Antirreumáticos/efectos adversos , Método Doble Ciego , Quimioterapia Combinada , Femenino , Humanos , Masculino , Metotrexato/efectos adversos , Persona de Mediana Edad , Inducción de Remisión , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
19.
Rheumatol Int ; 36(6): 863-9, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26995000

RESUMEN

To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1-5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70-100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions.


Asunto(s)
Traumatismos del Tobillo/diagnóstico por imagen , Articulación del Tobillo/diagnóstico por imagen , Artritis Reumatoide/diagnóstico por imagen , Traumatismos de los Tendones/diagnóstico por imagen , Tendones/diagnóstico por imagen , Ultrasonografía , Anciano , Anciano de 80 o más Años , Cadáver , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Distribución Aleatoria , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA