Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 207
Filtrar
1.
JACC Case Rep ; 29(18): 102526, 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39360000

RESUMEN

Singleton pregnancy in Fontan patients is burdened by a significant maternal cardiovascular and obstetric risk. The cardiac workload in a twin pregnancy is greater and could place Fontan-palliated patients at an increased risk of complications. We report a case of a woman with Fontan circulation and homozygous MTHFR mutation who had a twin pregnancy.

2.
Pediatr Cardiol ; 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39287667

RESUMEN

Despite the clinical results of the Fontan operation have certainly improved, it still presents with an inherent surgical risk of death and early morbidities. This is a retrospective clinical study of children undergoing Fontan operation in 9 congenital cardiac centers in Italy between 1990 and 2023. Clinical and surgical data were collected via a dedicated RedCap database. Primary outcome was cohort's mortality, also considering different decades, while secondary outcomes were postoperative complications and reintervention. In the last 3 decades, there were 897 patients undergoing Fontan operation, M/F 512/384, median age: 4.5 years (IQR 3.3-6.4), median weight 16 kg (IQR 14-22). A first palliation was deemed necessary in 710 patients (80%), and most patients underwent a staged Fontan (93%); an extracardiac conduit was used in 790 patients (88%). Postoperative complications (mild to severe) occurred in 410 patients (46%), and early reinterventions were required in 66 patients (7.5%). Overall operative mortality was 1.7% (15 patients). Age at Fontan greater than 4 years was associated with an early need for transcatheter reintervention (adj p value = 0.037) and a higher incidence of postoperative complications (adj p value = 0.017). The Fontan operation has seen significant improvements in immediate outcomes, notably a remarkable reduction in overall mortality to just 1.35% in the last decade. While minor complications have remained steady, there has been a substantial decrease in major early complications, deaths, and the need for reinterventions. Notably, patients aged over 4 years seem to face a higher risk of postoperative morbidity, underscoring the critical role of age in preoperative assessment and management strategies for Fontan patients.

4.
J Cardiovasc Dev Dis ; 11(7)2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-39057614

RESUMEN

BACKGROUND: Stent implantation has become the preferred method of treatment for treating vessel stenosis in congenital heart diseases. The availability of covered stents may decrease complications and have an important role in the management of patients with complex anatomy. AIM: This study aims to evaluate the feasibility and safety of the pre-mounted cobalt-chromium stent-graft-covered ePTFE Aortic BeGraft in a broad spectrum of vascular lesions. METHODS: This is a multicenter retrospective results analysis of 107 implanted BeGraft stents between 2016 and 2022 in six different European centers. RESULTS: One hundred and four patients with a mean age of thirteen years (range 1-70 years) and with the body weight of 56.5 kg (range 11-115 kg) underwent the BeGraft stent implantation. Stents were implanted in the following conditions: aortic coarctation (74 patients), RVOT dysfunction (12 patients), Fontan circulation (7 patients), and miscellaneous (11 subjects with complex CHD). All the stents were implanted successfully. The median stent diameter was 16 mm (range 7-24 mm), and the median length was 39 mm (range 19-49 mm). Major complications occurred in five subjects (4.7%). During a median follow-up of fourteen (1-70) months, stents' re-dilatation was performed in five patients. CONCLUSIONS: The BeGraft stent can be used safely and effectively in a wide spectrum of congenital heart diseases. Whether these good results will be stable in the longer term still needs to be investigated in a follow-up given its recent introduction into clinical practice, in particular regarding stent fracture or neointimal proliferation.

5.
J Clin Med ; 13(14)2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39064274

RESUMEN

The CardioMEMS HF System (Abbott, Abbott Park, IL) is the first FDA- and CE-Mark-approved device for monitoring patients with heart failure, significantly reducing hospitalizations and improving the quality of life for NYHA class III non-congenital adult patients. This device, implanted percutaneously, allows the direct monitoring of pulmonary arterial pressure with the wireless transfer of pressure data to the clinician, who can adjust the therapy remotely. Limited experience exists regarding its use in patients with congenital heart disease (CHD). CardioMEMS device implantation is feasible and safe in selected adults and children with CHD. The potential of the device to reduce heart failure hospitalizations in this population is enormous, but further multi-center studies are needed to demonstrate its efficacy.

6.
Pediatr Cardiol ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38727825

RESUMEN

This study aimed to evaluate the current state of congenital interventional cardiology training worldwide, with a focus on case volumes, competency assessment, and the need for ongoing mentorship during early career stages. A survey was conducted among program directors (PDs) of congenital interventional training programs across the globe. The survey gathered data on training pathways, case volumes, types of procedures performed, trainee competency assessment, and the role of ongoing mentorship. Of the 79 PDs who completed the survey, it was observed that training pathways and case volumes varied significantly, particularly between the United States and other countries. Most PDs reported an annual laboratory case volume of >500 congenital cardiac cases, with most cases being interventional. While trainees demonstrated competency in simple procedures (diagnostic cases, simple ASD closure), complex interventions (such as patent ductus arteriosus closure in premature infants) require ongoing mentorship for graduates. PDs recommended a minimum case volume of 400 total cases for trainees, including 250 interventional cases. In addition to case volumes, assessing trainee competency was deemed important, with clinical reasoning, judgment, skillset, teamwork, and complication management being key areas of evaluation. The study highlights the variability in congenital interventional cardiology training and the need for ongoing mentorship during the early career years. External mentorship programs, facilitated by national and international societies, are proposed to provide critical support for early career interventionalists thus enhancing patient care for congenital heart disease. Ultimately, the findings of this survey may serve as a framework for future training standards and guidelines in this specialized field.

7.
J Clin Med ; 13(5)2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38592039

RESUMEN

BACKGROUND: Despite a successful repair of tetralogy of Fallot (rToF) in childhood, residual lesions are common and can contribute to impaired exercise capacity. Although both cycle ergometer and treadmill protocols are often used interchangeably these approaches have not been directly compared. In this study we examined cardiopulmonary exercise test (CPET) measurements in rToF. METHODS: Inclusion criteria were clinically stable rToF patients able to perform a cardiac magnetic resonance imaging (CMR) and two CPET studies, one on the treadmill (incremental Bruce protocol) and one on the cycle ergometer (ramped protocol), within 12 months. Demographic, surgical and clinical data; functional class; QRS duration; CMR measures; CPET data and international physical activity questionnaire (IPAQ) scores of patients were collected. RESULTS: Fifty-seven patients were enrolled (53% male, 20.5 ± 7.8 years at CPET). CMR measurements included a right ventricle (RV) end-diastolic volume index of 119 ± 22 mL/m2, a RV ejection fraction (EF) of 55 ± 6% and a left ventricular (LV) EF of 56 ± 5%. Peak oxygen consumption (VO2)/Kg (25.5 ± 5.5 vs. 31.7 ± 6.9; p < 0.0001), VO2 at anaerobic threshold (AT) (15.3 ± 3.9 vs. 22.0 ± 4.5; p < 0.0001), peak O2 pulse (10.6 ± 3.0 vs. 12.1± 3.4; p = 0.0061) and oxygen uptake efficiency slope (OUES) (1932.2 ± 623.6 vs. 2292.0 ± 639.4; p < 0.001) were significantly lower on the cycle ergometer compared with the treadmill, differently from ventilatory efficiency (VE/VCO2) max which was significantly higher on the cycle ergometer (32.2 ± 4.5 vs. 30.4 ± 5.4; p < 0.001). Only the VE/VCO2 slope at the respiratory compensation point (RCP) was similar between the two methodologies (p = 0.150). CONCLUSIONS: The majority of CPET measurements differed according to the modality of testing, with the exception being the VE/VCO2 slope at RCP. Our data suggest that CPET parameters should be interpreted according to test type; however, these findings should be validated in larger populations and in a variety of institutions.

8.
Pediatr Cardiol ; 45(3): 695-698, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38308059

RESUMEN

The Atrial Flow Regulator (AFR) is a self-expandable double-disc device with a central fenestration, intended to maintain a calibrated communication across the interatrial septum. We reported for the first time a stent implantation across an AFR device in an adolescent born with complex congenital heart disease with duct-dependent systemic circulation and severe combined pulmonary hypertension.


Asunto(s)
Tabique Interatrial , Hipertensión Pulmonar , Adolescente , Humanos , Atrios Cardíacos/cirugía , Tabique Interatrial/diagnóstico por imagen , Tabique Interatrial/cirugía , Stents
9.
Clin Case Rep ; 12(2): e8401, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38356779

RESUMEN

The case highlights the good survival after radical surgery and chemotherapy of a cardiac sarcoma, and the need for close follow-up due to possible early postsurgical complications.

11.
Eur Heart J ; 45(3): 198-210, 2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-37874971

RESUMEN

BACKGROUND AND AIMS: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI. METHODS: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries. RESULTS: Data for 840 consecutive patients treated in 2014-2021 at a median age of 29.2 (19.0-41.6) years were obtained. The most common diagnosis was conotruncal defect (70.5%), with a native or patched RVOT in 50.7% of all patients. Valve sizes were 20, 23, 26, and 29 mm in 0.4%, 25.5%, 32.1%, and 42.0% of patients, respectively. Valve implantation was successful in 98.5% [95% confidence interval (CI), 97.4%-99.2%] of patients. Median follow-up was 20.3 (7.1-38.4) months. Eight patients experienced infective endocarditis; 11 required pulmonary valve replacement, with a lower incidence for larger valves (P = .009), and four experienced pulmonary valve thrombosis, including one who died and three who recovered with anticoagulation. Cumulative incidences (95%CI) 1, 3, and 6 years after TPVI were as follows: infective endocarditis, 0.5% (0.0%-1.0%), 0.9% (0.2%-1.6%), and 3.8% (0.0%-8.4%); pulmonary valve replacement, 0.4% (0.0%-0.8%), 1.3% (0.2%-2.4%), and 8.0% (1.2%-14.8%); and pulmonary valve thrombosis, 0.4% (0.0%-0.9%), 0.7% (0.0%-1.3%), and 0.7% (0.0%-1.3%), respectively. CONCLUSIONS: Outcomes of SAPIEN 3 TPVI were favourable in patients with CHD, half of whom had native or patched RVOTs.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Cardiopatías Congénitas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Trombosis , Adulto , Humanos , Cateterismo Cardíaco/efectos adversos , Endocarditis/epidemiología , Endocarditis Bacteriana/complicaciones , Cardiopatías Congénitas/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Diseño de Prótesis , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/epidemiología , Insuficiencia de la Válvula Pulmonar/cirugía , Sistema de Registros , Estudios Retrospectivos , Trombosis/etiología , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 103(2): 322-325, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38091330

RESUMEN

Aortic wall injuries may occur after interventional treatment of aortic coarctation (CoA), especially after balloon angioplasty. We reported on a patient who presented with an intra-stent aneurysm formation after direct stenting of a native near atretic aortic CoA by using a BeGraft Aortic stent. This evidence supports the need to maintain a strict follow-up protocol. A computed tomography scan is mandatory, after covered stent implantation as well, especially in high-risk cases and even in the absence of any immediate apparent complication.


Asunto(s)
Aneurisma de la Aorta , Coartación Aórtica , Humanos , Resultado del Tratamiento , Aorta/lesiones , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/etiología , Aneurisma de la Aorta/cirugía , Stents/efectos adversos , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía
13.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-38132644

RESUMEN

Persistent patent ductus arteriosus is a very common condition in preterm infants. Although there is no management agreed by consensus, despite numerous randomized controlled trials, hemodynamically significant patent ductus arteriosus increases morbidity and mortality in these vulnerable patients. Medical treatment is usually offered as first-line therapy, although it carries a limited success rate and potential severe adverse events. In recent years, transcatheter patent ductus arteriosus closure has fast developed and become widely accepted as a safe and efficient alternative to surgical ductal ligation in extremely low birth weight infants >700 g, using most often the dedicated Amplatzer Piccolo Occluder device. This article aims to provide an appraisal of the patients' selection process, and a step-by-step description of the procedure as well as a comprehensive review of its outcomes.

14.
Ital J Pediatr ; 49(1): 147, 2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-37932790

RESUMEN

Ductal patency of preterm infants is potentially associated with long term morbidities related to either pulmonary overflow or systemic steal. When an interventional closure is needed, it can be achieved with either surgical ligation or a catheter-based approach.Transcatheter PDA closure is among the safest of interventional cardiac procedures and it is the first choice for ductal closure in adults, children, and infants weighing more than 6 kg. In preterm and very low birth weight infants, it is increasingly becoming a valid and safe alternative to ligation, especially for the high success rate and the minor invasiveness and side effects. Nevertheless, being it performed at increasingly lower weights and gestational ages, hemodynamic complications are possible events to be foreseen.Procedural steps, timing, results, possible complications and available monitoring systems, as well as future outlooks are here discussed.


Asunto(s)
Conducto Arterioso Permeable , Monitorización Hemodinámica , Lactante , Niño , Recién Nacido , Humanos , Recien Nacido Prematuro , Conducto Arterioso Permeable/cirugía , Estudios de Factibilidad , Edad Gestacional , Resultado del Tratamiento
16.
Cardiol Young ; : 1-8, 2023 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-37212061

RESUMEN

To reflect new developments in imaging, indications, and techniques in catheterisation of patients with CHD, the training recommendations of the Association for European Paediatric and Congenital Cardiology (AEPC) for the training in interventional catheterisation for CHD have been reviewed and updated after more than 7 years. They include detailed information about knowledge, skills, and approach to clinical practice expected from trainees at basic, intermediate, and advanced level.

17.
Sci Bull (Beijing) ; 68(10): 1051-1059, 2023 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-37179234

RESUMEN

Although the use of bioabsorbable occluder is expected to reduce the risk of metal occluder-related complications, it has not been approved due to incomplete degradation and new complications. Novel fully bioabsorbable occluders were designed to overcome such limitations. The aim of this study was to investigate the efficacy and safety of a fully biodegradable occluder in patients with ventricular septal defects. 125 patients with perimembranous ventricular septal defect (VSD) larger than 3 mm were screened from April 2019 to January 2020 in seven centers. 108 patients were enrolled and randomized into the bioabsorbable occluder group (n = 54 patients) and nitinol occluder group (n = 54). A non-inferiority design was utilized and all patients underwent transcatheter device occlusion. Outcomes were analyzed with a 24-month follow-up. All patients were successfully implanted and completed the trial. No residual shunt >2 mm was observed during follow-up. Transthoracic echocardiography showed a hyperechoic area corresponding to the bioabsorbable occluder which decreased primarily during the first year after implantation and disappeared within 24 months. Postprocedural arrhythmia was the only occluder-related complication with an incidence of 5.56% and 14.81% for the bioabsorbable and nitinol groups, respectively (P = 0.112). The incidence of sustained conduction block was lower in the bioabsorbable occluder group (0/54 vs. 6/54, P = 0.036) at 24-month follow-up. In conclusion, the novel fully bioabsorbable occluder can be successfully and safely implanted under echocardiography guidance and reduce the incidence of sustained postprocedural arrythmia. The efficacy and safety of this fully biodegradable occluder are non-inferior to that of a traditional nitinol one.


Asunto(s)
Implantes Absorbibles , Defectos del Tabique Interventricular , Humanos , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Defectos del Tabique Interventricular/diagnóstico por imagen , Arritmias Cardíacas/complicaciones
18.
Catheter Cardiovasc Interv ; 101(6): 1098-1107, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37002948

RESUMEN

BACKGROUND: The superior sinus venosus atrial septal defect is a congenital communication between the left and right atria. Open surgical approach by patch closure has historically been the only treatment option. Recently, a transcatheter approach has been developed. This study aims to compare the efficacy and safety of surgical and transcatheter approach in treatment of sinus venosus atrial septal defect. METHODS: Between March 2010 and December 2020, 58 patients (median age: 45.4, range 14.8-73.8) underwent either surgical or transcatheter correction of superior sinus venosus atrial septal defect with partial anomalous pulmonary venous drainage. RESULTS: Twenty-four patients (median age: 35.4, range 14.8-66.8) underwent surgery while 34 patients (median age: 46.8, range 15.5-73.8) had a transcatheter treatment. During the catheterization era, 41 patients was considered suitable for a transcatheter closure. In 5 patients, surgery was the patient's or referring physician's choice. In 2 cases, the procedure was unsuccessful; the remaining 34 were successfully closed (94.4% of cases). Intensive care unit stay (median of 1 day, range 0.5-4, vs. 0, range 0-2, p < 0.0001) and hospital stay (median 7 days, range 2-15 vs. 2 days, range 1-12, p < 0.0001), were significantly longer in the surgery group. Total early complication rate, consisted on procedural and in-hospital complication, were higher in the surgical group (62.5% vs. 23.5%; p = 0.005). However, complications in both groups were clinically mild. At follow-up, a small residual shunt was present in 6 patients (surgery group: 2 pts; catheterization group: 4 pts; p: NS). Imaging studies showed significant improvement of right ventricular size and unobstructed pulmonary venous return in all patients. No late complications occurred at follow-up. CONCLUSIONS: Transcatheter correction of sinus venosus atrial septal defect is effective and safe in selected patients and may be considered as a valid alternative to surgery.


Asunto(s)
Apéndice Atrial , Defectos del Tabique Interatrial , Humanos , Persona de Mediana Edad , Adulto , Resultado del Tratamiento , Atrios Cardíacos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia
19.
Pediatr Cardiol ; 2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36795121

RESUMEN

The Atrial Flow Regulator (AFR) is a self-expandable double-disk device with a central fenestration, intended to maintain a calibrated communication across the interatrial septum. Only case reports and small case series have been published about its use in the pediatric and congenital heart disease (CHD) population. We described AFR implantation in three congenital patients with different anatomies and indications. In the first case, the AFR was deployed to create a stable fenestration in a Fontan conduit, while in the second, it was used to reduce a Fontan fenestration. In the third case, we implanted an AFR to decompress the left atrium of an adolescent with complex CHD in natural history, with complete mixing, ductal-dependent systemic circulation and combined pulmonary hypertension. This case series demonstrates the great potential of the AFR device in the CHD field, showing versatility, efficacy, and safety in establishing a calibrated and stable shunt, with promising hemodynamic and symptomatic benefits.

20.
Cardiol Young ; 33(8): 1468-1470, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36720716

RESUMEN

Pulmonary artery stenosis is one of the most common complications after arterial switch operation. Stent implantation is an effective treatment with some risks related to coronary artery compression. We present the case of a patient affected by pulmonary stenosis after arterial switch operation. Coronary compression testing demonstrated compression of the left coronary artery from the balloon inflated in the left pulmonary artery. We should systematically consider the use of coronary balloon testing before stent implantation in patients with a history of switch operation.


Asunto(s)
Operación de Switch Arterial , Transposición de los Grandes Vasos , Humanos , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Operación de Switch Arterial/efectos adversos , Transposición de los Grandes Vasos/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Stents
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA