Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Tumori ; 100(3): 302-6, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25076242

RESUMEN

AIMS AND BACKGROUND: Brain metastases are a prevalent consequence of systemic cancer, and patients suffering from brain metastases usually present with multiple metastatic lesions. An overwhelming majority of the available literature assessing the role of stereotactic radiosurgery in brain metastasis management includes patients with up to 4 metastases. Given the significant benefit of stereotactic radiosurgery for the treatment of 1 to 3 brain metastases, we evaluated the use of stereotactic radiosurgery boost after whole brain irradiation in the management of patients with ≥4 brain metastases. METHODS: In this retrospective analysis, outcomes of 50 patients who underwent linear accelerator-based stereotactic radiosurgery boost within 4 to 6 weeks of whole brain irradiation for ≥4 brain metastases were assessed in terms of local control, overall survival, primary involved organ, recursive partitioning analysis class and Karnofsky performance status at the time of stereotactic radiosurgery, number of lesions, age, status of the primary cancer (controlled vs uncontrolled), presence of extracranial disease and toxicity. RESULTS: Fifty patients with ≥4 brain metastases were treated using linear accelerator-based stereotactic radiosurgery boost after whole brain irradiation between April 1998 and April 2013. Mean and median number of intracranial lesions was 6.02 and 6, respectively. Median lesion volume was 10.9 cc (range, 0.05-32.6). Median survival time after radiosurgery was 10.1 months (range, 1-25). Status of the primary cancer (controlled vs uncontrolled), recursive partitioning analysis class, Karnofsky performance status, and extracranial metastasis showed statistically significant correlations with overall survival (P <0.001). Treatment-related side effects after stereotactic radiosurgery included temporary edema (n = 14, 28%), hemiparesis (n = 1, 2%), seizure (n = 1, 2%), leukoencephalopathy (n = 2, 4%), and radiation necrosis (n = 6, 12%). CONCLUSIONS: Linear accelerator-based stereotactic radiosurgery boost within 4 to 6 weeks after whole brain irradiation proved to be an efficacious and well-tolerated treatment strategy for the management of patients with ≥4 brain metastases in our study.


Asunto(s)
Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/cirugía , Irradiación Craneana , Radiocirugia/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
2.
Phys Med ; 25(1): 31-42, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18440265

RESUMEN

Interventional cardiological examinations may be associated with excessive radiation exposures which may cause skin injuries and higher probabilities of stochastic effects. Dose-area product (DAP) and skin doses of 325 patients were measured using alternative dosimetric techniques for different cardiological examinations. Data were collected from five different systems with the involvement of 11 cardiologists. All these dosimetric information has been collected separately for each of 10 projections together with the exposure parameters of X-ray systems. Mean DAP values measured with a transparent ion chamber were 49.1 Gy cm(2), 66.8 Gy cm(2), 106.9 Gy cm(2) and 124.7 Gy cm(2), respectively, for coronary angiography (CA), percutaneous transluminal coronary angioplasty (PTCA) or stent (PT-SI), coronary angiography and/or PTCA and/or stent (CA-PT-SI), and ablation examinations. Radiochromic films, thermoluminescent dosimeters (TLD) and point measurement of air kerma (AK) were carried out for skin dose assessments. Skin doses of 23 patients measured with radiochromic films were found to be between 2 Gy and 6 Gy. Although the complexity of the procedures was the major reason for these excessive doses, considerable contributions of high X-ray output of some fluoroscopy units were also noticed. In addition to the direct measurement of DAP, alternative DAP values were also determined from the skin dose measurement techniques; exposed areas were summed on digitized radiochromic films in one technique, The product of AK reading with X-ray field size measured at the patient entrance using slow X-ray films was taken as another DAP. Good correlations were found among the DAP results and also between the entrance skin doses calculated from AK measurements and direct DAP readings (R(2)=0.91). A trigger DAP value of 130 Gy cm(2) for the 2 Gy of skin doses was derived from this relationship. Collection of dosimetric data for each projection was also investigated regarding a possible standardization of clinical techniques; in the case of coronary angiography examinations LAO 45 and RAO 30 were found as the dominant projections which may also simplify the dosimetric technique.


Asunto(s)
Cardiología/métodos , Radiografía Intervencional/métodos , Radiometría/métodos , Angioplastia Coronaria con Balón/métodos , Angiografía Coronaria/métodos , Fluoroscopía/métodos , Humanos , Dosis de Radiación , Monitoreo de Radiación/métodos , Procesamiento de Señales Asistido por Computador , Piel/diagnóstico por imagen , Piel/efectos de la radiación , Película para Rayos X , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA