Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38746647

RESUMEN

Purpose: In stereotactic body radiation therapy (SBRT) for prostate cancer, intrafraction motion is an important source of treatment uncertainty as it could not be completely smoothed through fractionation. Herein, we compared different arrangements and beam qualities for extreme hypofractionated treatments to minimize beam delivery time and so intrafractional errors. Methods: A retrospective dataset of 11 patients was used. Three volumetric modulated arc therapy (VMAT) beam arrangements were compared for a prescription dose of 40 Gy/5 fractions: two full arcs, 6 MV flattening filter free (FFF); one full arc, 6 MV FFF; one full arc, 10 MV FFF. A plan quality index was defined to compare achievement of the planning goals. Plan complexity was evaluated with the modulation factor. Dose delivery accuracy and efficiency were measured with patient-specific quality assurance plans. Results: All treatment plans fulfilled all dose objectives. No statistical differences were found both in plan quality and complexity. Very accurate dose delivery was achieved with the three arrangements, with mean γ passing rates >96.5 % (2 %/2 mm criteria). Slightly but significantly higher γ passing rates were observed with single-arc 6 MV FFF. Contrariwise, statistically significant reductions of the delivery time were obtained with single-arc geometries: the average delivery times were 1.6 min (-46.1 %) and 1.3 min (-56.2 %) for 6 and 10 MV FFF respectively. Conclusions: The high-quality, very fast and accurate dose delivery of single-arc plans confirmed the suitability of this arrangement for prostate SBRT. In particular, the significant reduction of delivery time would improve treatment robustness against intrafraction prostate motion.

2.
Phys Med ; 112: 102633, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37423002

RESUMEN

PURPOSE: The young working group of the Italian Association of Medical and Health Physics (AIFM) designed a survey to assess the current situation of the under 35 AIFM members. METHODS: An online survey including 65 questions was designed to gather personal information, educational issues, working and research experience, and to evaluate the AIFM activities. The survey was distributed to the under 35 members between November 2022 and February 2023, through the young AIFM mailing list and social media. RESULTS: 160 answers from 230 affiliates (70%, 31 years median age) were obtained. The results highlighted that 87% of the respondents had a fixed term/permanent employment, mainly in public hospitals (58%). Regarding Medical Physicists (MPs) training, 54% of the students left their region of origin due to the training plan (40%) and the availability of scholarships (25%) in the chosen university. Most of the respondents have no Radiation Protection Expert title, while the remaining 20%, 6%, and 3% are qualified to the first, second, and third level, respectively. Several young MPs (62.2%) were involved in research activities; however, only 28% had teaching experience, mainly within their workplace (20%, safety courses), during AIFM courses (4%), or university lectures (3%). CONCLUSIONS: This survey reported the current situation of the under 35 AIFM members, highlighting the "brain drain" phenomenon from the south to the north of Italy, mainly due to the lack of post-graduate schools, scholarships, and job opportunities. The obtained results will help the future working program of the AIFM.


Asunto(s)
Física Sanitaria , Humanos , Encuestas y Cuestionarios , Física Sanitaria/educación , Italia , Universidades
3.
Int J Mol Sci ; 24(4)2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36834877

RESUMEN

Magnetic resonance imaging (MRI) is a non-invasive powerful modern clinical technique that is extensively used for the high-resolution imaging of soft tissues. To obtain high-definition pictures of tissues or of the whole organism this technique is enhanced by the use of contrast agents. Gadolinium-based contrast agents have an excellent safety profile. However, over the last two decades, some specific concerns have surfaced. Mn(II) has different favorable physicochemical characteristics and a good toxicity profile, which makes it a good alternative to the Gd(III)-based MRI contrast agents currently used in clinics. Mn(II)-disubstituted symmetrical complexes containing dithiocarbamates ligands were prepared under a nitrogen atmosphere. The magnetic measurements on Mn complexes were carried out with MRI phantom measurements at 1.5 T with a clinical magnetic resonance. Relaxivity values, contrast, and stability were evaluated by appropriate sequences. Studies conducted to evaluate the properties of paramagnetic imaging in water using a clinical magnetic resonance showed that the contrast, produced by the complex [Mn(II)(L')2] × 2H2O (L' = 1.4-dioxa-8-azaspiro[4.5]decane-8-carbodithioate), is comparable to that produced by gadolinium complexes currently used in medicine as a paramagnetic contrast agent.


Asunto(s)
Medios de Contraste , Manganeso , Manganeso/química , Medios de Contraste/química , Gadolinio/química , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética
4.
Phys Med ; 104: 167-173, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36463581

RESUMEN

PURPOSE: This Technical Note validates previously published data about the dosimetry of the electron beams produced by a mobile accelerator dedicated for intraoperative radiation therapy (IORT). The evaluation of the directional response of a PTW microDiamond detector is presented together with a detailed analysis of the output factors (OFs) for bevelled applicators. METHODS: The OFs of the 6, 8, 10 and 12 MeV electron beams produced by a light intraoperative accelerator (LIAC, SIT, Italy) were measured in a commercial water phantom using the microDiamond. A set of flat and bevelled applicators with sizes ranging from 4 to 10 cm was characterized. For bevelled applicators, a correction for the angular dependence of the microDiamond was calculated using a home-made spherical phantom. Correction factors were obtained through measurements performed rotating the accelerator treatment head at 0°, 15°, 30° and 45°. RESULTS: For flat applicators, the average deviation between measured and simulated OFs was (-1.1 ± 0.7)%. The microDiamond showed a higher angular dependence for the 6 MeV beam (∼8% for angles up to 45°, range 92 % ÷ 100 %), while the variations for 8, 10 and 12 MeV beams were âˆ¼ 4 % (range 97 % ÷ 101 %). Correcting for this dependence, the average deviation of the OFs for bevelled applicators was (-0.9 ± 1.6)%. CONCLUSIONS: The presented results were in very good agreement with those reported in literature. Very similar deviations were found between flat and bevelled applicators confirming the suitability of our method to determine the angular dependence correction factors of the microDiamond detector.


Asunto(s)
Periodo Intraoperatorio , Método de Montecarlo , Radioterapia , Italia , Dosimetría por Película , Humanos
5.
Eur Radiol Exp ; 4(1): 62, 2020 11 10.
Artículo en Inglés | MEDLINE | ID: mdl-33169295

RESUMEN

BACKGROUND: Radiomics is expected to improve the management of metastatic colorectal cancer (CRC). We aimed at evaluating the impact of liver lesion contouring as a source of variability on radiomic features (RFs). METHODS: After Ethics Committee approval, 70 liver metastases in 17 CRC patients were segmented on contrast-enhanced computed tomography scans by two residents and checked by experienced radiologists. RFs from grey level co-occurrence and run length matrices were extracted from three-dimensional (3D) regions of interest (ROIs) and the largest two-dimensional (2D) ROIs. Inter-reader variability was evaluated with Dice coefficient and Hausdorff distance, whilst its impact on RFs was assessed using mean relative change (MRC) and intraclass correlation coefficient (ICC). For the main lesion of each patient, one reader also segmented a circular ROI on the same image used for the 2D ROI. RESULTS: The best inter-reader contouring agreement was observed for 2D ROIs according to both Dice coefficient (median 0.85, interquartile range 0.78-0.89) and Hausdorff distance (0.21 mm, 0.14-0.31 mm). Comparing RF values, MRC ranged 0-752% for 2D and 0-1567% for 3D. For 24/32 RFs (75%), MRC was lower for 2D than for 3D. An ICC > 0.90 was observed for more RFs for 2D (53%) than for 3D (34%). Only 2/32 RFs (6%) showed a variability between 2D and circular ROIs higher than inter-reader variability. CONCLUSIONS: A 2D contouring approach may help mitigate overall inter-reader variability, albeit stable RFs can be extracted from both 3D and 2D segmentations of CRC liver metastases.


Asunto(s)
Neoplasias Colorrectales/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Variaciones Dependientes del Observador , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Neoplasias Colorrectales/tratamiento farmacológico , Medios de Contraste , Femenino , Humanos , Neoplasias Hepáticas/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados
6.
Phys Med Biol ; 65(19): 195012, 2020 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-32575082

RESUMEN

The aim of this multicentric study is an inter-center benchmarking, to assess how different set tools applied to the same radiomics workflow affected the radiomics features (RFs) values. This topic is of key importance to start collaboration between different centers and to bring radiomic studies from benchmark to bedside. A per-lesion analysis was performed on 56 metastases (mts) selected from 14 patients. A single radiologist performed the segmentation of all mts, and RFs were extracted from the same segmentation of each mts, using two different software and file formats. Potential sources of discrepancies were evaluated. The intraclass correlation coefficient was used to describe how strongly the same radiomic measurements calculated in the two different centers resemble each other. Moreover, means of the relative changes of each RF were calculated, compared and gradually reduced. We showed that, after matching all formulas, discrepancies in RFs calculation between two centers ranged from 1% to 277%. Therefore, we evaluated other sources of variability using a stepwise approach, which led us to reduce the inter-center discrepancies to 0% for 22/25 RFs and below 2% for 3 RFs out of 25. In this study we demonstrated that different radiomic applications and masks formats might strongly impact the computation of some RFs. Therefore, when dealing with multi-center studies it is mandatory to adopt all strategies that can help in limiting the differences, thus keeping in mind the feasibility of these strategies in large cohort studies.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Neoplasias del Colon/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias del Recto/diagnóstico por imagen , Programas Informáticos , Tomografía Computarizada por Rayos X/normas , Algoritmos , Humanos , Tomografía Computarizada por Rayos X/métodos
7.
Eur Radiol Exp ; 3(1): 27, 2019 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-31309360

RESUMEN

BACKGROUND: To manage and analyse dosimetric data provided by computed tomography (CT) scanners from four Italian hospitals. METHODS: A radiation dose index monitoring (RDIM) software was used to collect anonymised exams stored in a cloud server. Since hospitals use different names for the same procedure, digital imaging and communications in medicine (DICOM) tags more appropriate to describe exams were selected and associated to study common names (SCNs) from a radiology playbook according to scan region and use of contrast media. Retrospective analysis was carried out to describe population and to evaluate dosimetric indexes and inaccuracies associated with SCNs. RESULTS: More than 400 procedures were clustered into 95 SCNs, but 78% of exams on adults were described with only 10 SCNs. Median values of dose-length product (DLP) and volumetric CT dose index (CTDIvol) for three analysed SCNs were in agreement with those previously published. The percentage of inaccuracies does not heavily affect the dosimetric analysis on the whole cloud, since variations in median values reached at most 8%. CONCLUSIONS: Implementation of a cloud-based RDIM software and related issues were described, showing the strength of the chosen playbook-based clustering and its usefulness for homogeneous data analysis. This approach may allow for optimisation actions, accurate assessment of the risk associated with radiation exposure, comparison of different facilities, and, last but not least, collection of information for the implementation of the 2013/59 Euratom Directive.


Asunto(s)
Nube Computacional , Bases de Datos Factuales , Dosis de Radiación , Tomografía Computarizada por Rayos X , Humanos , Italia , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
8.
Inorg Chem ; 35(4): 898-905, 1996 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-11666263

RESUMEN

A reinvestigation of the redox behavior of the [Fe(3)(&mgr;(3)-S)(CO)(9)](2)(-) dianion led to the isolation and characterization of the new [Fe(5)S(2)(CO)(14)](2)(-), as well as the known [Fe(6)S(6)(CO)(12)](2)(-) dianion. As a corollary, new syntheses of the [Fe(3)S(CO)(9)](2)(-) dianion are also reported. The [Fe(5)S(2)(CO)(14)](2)(-) dianion has been obtained by oxidative condensation of [Fe(3)S(CO)(9)](2)(-) induced by tropylium and Ag(I) salts or SCl(2), or more straightforwardly through the reaction of [Fe(4)(CO)(13)](2)(-) with SCl(2). The [Fe(6)S(6)(CO)(12)](2)(-) dianion has been isolated as a byproduct of the synthesis of [Fe(3)S(CO)(9)](2)(-) and [Fe(5)S(2)(CO)(14)](2)(-) or by reaction of [Fe(4)(CO)(13)](2)(-) with elemental sulfur. The structures of [N(PPh(3))(2)](2)[Fe(5)S(2)(CO)(14)] and [N(PPh(3))(2)](2)[Fe(6)S(6)(CO)(12)] were determined by single-crystal X-ray diffraction analyses. Crystal data: for [N(PPh(3))(2)](2)[Fe(5)S(2)(CO)(14)], monoclinic, space group P2(1)/c (No. 14), a = 24.060(5), b = 14.355(6), c = 23.898(13) Å, beta = 90.42(3) degrees, Z = 4; for [N(PPh(3))(2)](2)[Fe(6)S(6)(CO)(12)], monoclinic, space group C2/c (No. 15), a = 34.424(4), b = 14.081(2), c = 19.674(2) Å, beta = 115.72(1) degrees, Z = 4. The new [Fe(5)S(2)(CO)(14)](2)(-) dianion shows a "bow tie" arrangement of the five metal atoms. The two Fe(3) triangles sharing the central Fe atom are not coplanar and show a dihedral angle of 55.08(3) degrees. Each Fe(3) moiety is capped by a triply bridging sulfide ligand. The 14 carbonyl groups are all terminal; two are bonded to the unique central atom and three to each peripheral iron atom. Protonation of the [Fe(5)S(2)(CO)(14)](2)(-) dianion gives reversibly rise to the corresponding [HFe(5)S(2)(CO)(14)](-) monohydride derivative, which shows an (1)H-NMR signal at delta -21.7 ppm. Its further protonation results in decomposition to mixtures of Fe(2)S(2)(CO)(6) and Fe(3)S(2)(CO)(9), rather than formation of the expected H(2)Fe(5)S(2)(CO)(14) dihydride. Exhaustive reduction of [Fe(5)S(2)(CO)(14)](2)(-) with sodium diphenyl ketyl progressively leads to fragmentation into [Fe(3)S(CO)(9)](2)(-) and [Fe(CO)(4)](2)(-), whereas electrochemical, as well as chemical oxidation with silver or tropylium tetrafluoroborate, in dichloromethane, generates the corresponding [Fe(5)S(2)(CO)(14)](-) radical anion which exhibits an ESR signal at g = 2.067 at 200 K. The electrochemical studies also indicated the existence of a subsequent one-electron anodic oxidation which possesses features of chemical reversibility in dichloromethane but not in acetonitrile solution. A reexamination of the electrochemical behavior of the [Fe(3)S(CO)(9)](2)(-) dianion coupled with ESR monitoring enabled the spectroscopic characterization of the [Fe(3)S(CO)(9)](-) radical monoanion and demonstrated its direct involvement in the generation of the [Fe(5)S(2)(CO)(14)](n)()(-) (n = 0, 1, 2) system.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA