Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
Phys Rev Lett ; 95(22): 221101, 2005 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-16384203

RESUMEN

The Laser Interferometer Gravitational-Wave Observatory has performed a third science run with much improved sensitivities of all three interferometers. We present an analysis of approximately 200 hours of data acquired during this run, used to search for a stochastic background of gravitational radiation. We place upper bounds on the energy density stored as gravitational radiation for three different spectral power laws. For the flat spectrum, our limit of omega0 < 8.4 x 10(-4) in the 69-156 Hz band is approximately 10(5) times lower than the previous result in this frequency range.

2.
Appl Opt ; 40(22): 3753-8, 2001 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-18360409

RESUMEN

The birefringence of a low-loss, high-reflectance coating applied to an 8-cm-diameter sapphire crystal grown in the m-axis direction has been mapped. By monitoring the transmission of a high-finesse Fabry-Perot cavity as a function of the polarization of the input light, we find an upper limit for the magnitude of the birefringence of 2.5 x 10(-4) rad and an upper limit in the variation in direction of the birefringence of 10 deg. These values are sufficiently small to allow consideration of m-axis sapphire as a substrate material for the optics of the advanced detector at the Laser Interferometer Gravitational Wave Observatory.

3.
J Opt Soc Am A Opt Image Sci Vis ; 17(1): 120-8, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10641846

RESUMEN

We present a method by which the effect of laser field variations on the signal output of an interferometric gravitational wave detector is rigorously determined. Using the Laser Interferometer Gravitational Wave Observatory (LIGO) optical configuration of a power recycled Michelson interferometer with Fabry-Perot arm cavities as an example, we calculate the excess noise after the input filter cavity (mode cleaner) and the dependence of the detector strain sensitivity on laser frequency and amplitude noise, radio frequency oscillator noise, and scattered-light phase noise. We find that noise on the radio frequency sidebands generally limits the detector's sensitivity.


Asunto(s)
Artefactos , Interferometría/instrumentación , Luz , Modelos Teóricos
4.
Opt Lett ; 24(15): 1014-6, 1999 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-18073925

RESUMEN

We present a new optical control scheme for a laser interferometric gravitational wave detector that has a high degree of tolerance to interferometer spatial distortions and noise on the input light. The scheme involves resonating the rf sidebands in an interferometer arm cavity.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA