RESUMEN
BACKGROUND: In the BRIGHT-4 (Bivalirudin With Prolonged Full-Dose Infusion During Primary PCI Versus Heparin Trial-4), anticoagulation with bivalirudin plus a 2- to 4-hour high-dose infusion after percutaneous coronary intervention (PCI) reduced all-cause mortality and bleeding without increasing reinfarction or stent thrombosis compared with heparin alone in patients with ST-segment elevation myocardial infarction (STEMI). These findings require external validation. OBJECTIVES: This study sought to determine outcomes of bivalirudin vs heparin anticoagulation during PCI in STEMI. METHODS: We performed an individual-patient-data meta-analysis of all large randomized trials of bivalirudin vs heparin in STEMI patients undergoing primary PCI performed before BRIGHT-4. The primary endpoint was all-cause mortality. RESULTS: Six trials randomizing 15,254 patients were included. Pooled across all regimens of bivalirudin and glycoprotein IIb/IIIa inhibitor (GPI) use, bivalirudin reduced 30-day all-cause mortality (2.5% vs 2.9%; adjusted OR: 0.78; 95% CI: 0.62-0.99), cardiac mortality (adjusted OR: 0.69; 95% CI: 0.54-0.88), and major bleeding (adjusted OR: 0.53; 95% CI: 0.44-0.64) but increased reinfarction (adjusted OR: 1.30; 95% CI: 1.02-1.65) and stent thrombosis (adjusted OR: 1.43; 95% CI: 1.05-1.93) compared with heparin. In 4 trials in which 6,244 patients were randomized to bivalirudin plus a high-dose post-PCI infusion vs heparin without planned GPI use (the BRIGHT-4 regimens), 30-day all-cause mortality occurred in 1.8% vs 2.9% of patients, respectively (adjusted OR: 0.74; 95% CI: 0.48-1.12), and bivalirudin reduced cardiac mortality (adjusted OR: 0.62; 95% CI: 0.39-0.97) and major bleeding (adjusted OR: 0.49; 95% CI: 0.35-0.70), with similar rates of reinfarction (adjusted OR: 0.89; 95% CI: 0.58-1.38) and stent thrombosis (adjusted OR: 0.80; 95% CI: 0.41-1.57). CONCLUSIONS: In STEMI patients undergoing primary PCI, bivalirudin with a 2- to 4-hour post-PCI high-dose infusion reduced cardiac mortality and major bleeding without an increase in ischemic events compared with heparin monotherapy with provisional GPI use, confirming the BRIGHT-4 results.
Asunto(s)
Anticoagulantes , Antitrombinas , Heparina , Hirudinas , Fragmentos de Péptidos , Intervención Coronaria Percutánea , Proteínas Recombinantes , Infarto del Miocardio con Elevación del ST , Hirudinas/administración & dosificación , Humanos , Fragmentos de Péptidos/administración & dosificación , Fragmentos de Péptidos/uso terapéutico , Heparina/administración & dosificación , Heparina/efectos adversos , Proteínas Recombinantes/administración & dosificación , Proteínas Recombinantes/uso terapéutico , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/mortalidad , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Intervención Coronaria Percutánea/métodos , Antitrombinas/administración & dosificación , Antitrombinas/uso terapéutico , Masculino , Femenino , Ensayos Clínicos Controlados Aleatorios como Asunto , Persona de Mediana Edad , Resultado del TratamientoRESUMEN
BACKGROUND: Mitral valve regurgitation (MR) is associated with worse outcomes in patients undergoing percutaneous coronary intervention (PCI). We sought to evaluate outcomes of Impella-supported high-risk PCI (HRPCI) patients according to MR severity. METHODS: Patients from the PROTECT III study undergoing Impella-supported HRPCI were stratified into 4 groups according to MR severity: No or trace MR, mild MR, moderate MR, and severe MR. Immediate PCI-related complications, major adverse cardiovascular and cerebrovascular events (MACCE: all-cause death, myocardial infarction, stroke/transient ischemic attack, and repeat revascularization) at 90 days and death at 1-year were assessed. RESULTS: From March 2017 to March 2020, 631 patients who underwent Impella-supported HRPCI in the PROTECT III study had evaluable MR severity at baseline. Patients with severe MR had lower body mass indices, lower left ventricular ejection fractions (LVEFs), and were more frequently diagnosed with heart failure. The incidence of immediate PCI-related complications was similar between groups. Unadjusted 90-day MACCE and 1-year mortality rates were numerically higher in patients with severe MR compared to the other study groups yet without reaching statistical significance. In multivariable analyses, there was no significant association between the presence of severe MR for 90-day MACCE or 1-year mortality compared with other degrees of MR (adj. HR = 1.71, 95% CI [0.73, 3.98], p = 0.21; adj. HR = 1.79, 95% CI [0.86, 3.74], p = 0.12, respectively). CONCLUSIONS: Impella-supported HRPCI patients with moderate or severe MR exhibited a higher prevalence of heart failure, lower LVEF, and longer hospital stays. Patients with severe MR showed numerically higher unadjusted rates of 90-day MACCE and 1-year mortality compared to other groups, however these differences did not reach statistical significance even after adjustment for potential confounders. CLINICAL TRIAL INFORMATION: Trial Name: The Global cVAD Study (cVAD) ClinicalTrial.govIdentifier:NCT04136392 URL: https://clinicaltrials.gov/ct2/show/NCT04136392?term=cvad&draw=2&rank=2.
Asunto(s)
Corazón Auxiliar , Insuficiencia de la Válvula Mitral , Intervención Coronaria Percutánea , Humanos , Masculino , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Femenino , Intervención Coronaria Percutánea/métodos , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Factores de Riesgo , Estudios de SeguimientoRESUMEN
BACKGROUND: The occurrence of conduction disturbances (CDs) remains the most frequent complication of transcatheter aortic valve replacement (TAVR). However, little is known about the timing of electrocardiogram (ECG) changes and CDs during the TAVR procedure. OBJECTIVE: The objective of this study was to describe ECG changes throughout the TAVR procedure using the CARA monitor. METHODS: This was a multicenter study including 196 prospectively enrolled patients without preexisting CDs undergoing TAVR. All patients were monitored with the CARA system, which uses a 12-lead ECG to measure PQ and QRS intervals, QRS axis, and variations with each heartbeat at every step: baseline, wire insertion, pre-dilatation, valve deployment, post-dilatation, and end of procedure. RESULTS: PQ and QRS intervals progressively increased throughout the procedure, with a cumulative increase from 169.2 ± 20.0 ms to 186.0 ± 31.6 ms (P < .001) for the PQ interval and from 101.3 ± 10.5 ms to 126.0 ± 25.4 ms (P < .001) for the QRS interval, from baseline to the end of the procedure. A significant increase in the number of patients with left axis deviation was observed (7.7% at baseline vs 31.8% at end of procedure; P < .001). A total of 161 (82.1%) patients exhibited at least 1 CD episode (PQ >200 ms, QRS ≥120 ms, advanced heart block) during the procedure, with most episodes occurring during pre-dilatation and valve implantation maneuvers. CONCLUSION: The CARA system facilitated real-time ECG monitoring, detecting subtle and progressive changes during TAVR. ECG changes occurred at each step, with most patients experiencing CDs, especially during pre-dilatation and valve implantation. The potential clinical impact of monitoring ECG dynamics and timing for early detection of severe CDs should be explored in future studies.
RESUMEN
Aortic stenosis, the most common valvular disease in the Western world, has traditionally been treated with surgical aortic valve replacement (SAVR) but is increasingly treated by transcatheter aortic valve replacement (TAVR). Whereas patients older than 65 years are preferably treated with bioprosthetic tissue valves, there is considerable uncertainty in the choice between TAVR and SAVR. We present various considerations for optimizing the lifelong management of patients receiving bioprosthetic valves (SAVR or TAVR). To maximize life expectancy and to minimize cumulative lifetime risk, we suggest decision-making individualized for patient anatomy and overall (current and future) risk.
RESUMEN
BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Factores de Riesgo , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Estados Unidos/epidemiologíaRESUMEN
BACKGROUND: Mortality after ST-segment elevation myocardial infarction (STEMI) is increased in patients with hypertension. The mechanisms underlying this association are uncertain. We sought to investigate whether patients with STEMI and prior hypertension have greater microvascular obstruction (MVO) and infarct size (IS) compared with those without hypertension. METHODS: We pooled individual patient data from 7 randomized trials of patients with STEMI undergoing primary percutaneous coronary intervention (PCI) in whom cardiac magnetic resonance imaging was performed within 1 month after reperfusion. The associations between hypertension and MVO, IS, and mortality were assessed in multivariable adjusted models. RESULTS: Among 2174 patients (61.3 ± 12.6 years, 76% male), 1196 (55.0%) had hypertension. Patients with hypertension were older, more frequently diabetic and had more extensive coronary artery disease than those without hypertension. MVO and IS measured as percent LV mass were not significantly different in patients with and without hypertension (adjusted differences 0.1, 95% CI -0.3 to 0.6, P = .61 and -0.2, 95% CI -1.5 to 1.2, P = .80, respectively). Hypertension was associated with a higher unadjusted risk of 1-year death (hazard ratio [HR] 2.28, 95% CI 1.44-3.60, P < .001), but was not independently associated with higher mortality after multivariable adjustment (adjusted HR 1.04, 95% CI 0.60-1.79, P = .90). CONCLUSION: In this large-scale individual patient data pooled analysis, hypertension was not associated with larger IS or MVO after primary PCI for STEMI.
Asunto(s)
Hipertensión , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/cirugía , Infarto del Miocardio con Elevación del ST/mortalidad , Intervención Coronaria Percutánea/métodos , Masculino , Femenino , Persona de Mediana Edad , Hipertensión/complicaciones , Imagen por Resonancia Cinemagnética/métodos , Anciano , Microcirculación , Imagen por Resonancia Magnética/métodos , Ensayos Clínicos Controlados Aleatorios como AsuntoRESUMEN
BACKGROUND: The importance of complete revascularization after percutaneous coronary intervention (PCI) in patients with left main coronary artery disease is uncertain. We investigated the clinical impact of complete revascularization in patients with left main coronary artery disease undergoing PCI in the EXCEL trial (Evaluation of XIENCE Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization). METHODS: Composite rates of death or myocardial infarction (MI) following PCI during 5-year follow-up were examined in 903 patients based on core laboratory definitions of anatomic and functional complete revascularization, residual SYNTAX score (The Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery), and residual Jeopardy Score (rJS). RESULTS: The risk of death or MI did not vary based on anatomic, functional, or residual SYNTAX score complete revascularization but did differ according to the rJS (5-year rates 17.6%, 19.5%, and 38.9% with rJS 0, 2, and ≥4, respectively; P=0.006). The higher rate of death or MI with rJS≥4 versus rJS≤2 was driven conjointly by increased mortality (adjusted hazard ratio, 2.29 [95% CI, 1.11-4.71]; P=0.02) and spontaneous MI (adjusted hazard ratio, 2.89 [95% CI, 1.17-7.17]; P=0.02). The most common location for untreated severe stenoses in the rJS≥4 group was the left circumflex artery (LCX), and the post-PCI absence, compared with the presence, of any untreated lesion with diameter stenosis ≥70% in the LCX was associated with reduced 5-year rates of death or MI (18.9% versus 35.2%; hazard ratio, 0.48 [95% CI, 0.32-0.74]; P<0.001). The risk was the highest for residual ostial/proximal LCX lesions. CONCLUSIONS: Among patients undergoing PCI in EXCEL trial, incomplete revascularization according to the rJS was associated with increased rates of death and spontaneous MI. Post-PCI untreated high-grade lesions in the LCX (especially the ostial/proximal LCX) drove these outcomes. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01205776.
Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Constricción Patológica , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Resultado del TratamientoRESUMEN
BACKGROUND: The benefit:risk profile of bivalirudin versus heparin anticoagulation in patients with non-ST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention (PCI) is uncertain. Study-level meta-analyses lack granularity to provide conclusive answers. We sought to compare the outcomes of bivalirudin and heparin in patients with non-ST-segment-elevation myocardial infarction undergoing PCI. METHODS: We performed an individual patient data meta-analysis of patients with non-ST-segment-elevation myocardial infarction in all 5 trials that randomized ≥1000 patients with any myocardial infarction undergoing PCI to bivalirudin versus heparin (MATRIX [Minimizing Adverse Hemorrhagic Events by Transradial Access Site and Systemic Implementation of Angiox], VALIDATE-SWEDEHEART [Bivalirudin Versus Heparin in ST-Segment and Non-ST-Segment Elevation Myocardial Infarction in Patients on Modern Antiplatelet Therapy in the Swedish Web System for Enhancement and Development of Evidence-Based Care in Heart Disease Evaluated According to Recommended Therapies Registry Trial], ISAR-REACT 4 [Intracoronary Stenting and Antithrombotic Regimen: Rapid Early Action for Coronary Treatment 4], ACUITY [Acute Catheterization and Urgent Intervention Triage Strategy], and BRIGHT [Bivalirudin in Acute Myocardial Infarction vs Heparin and GPI Plus Heparin Trial]). The primary effectiveness and safety end points were 30-day all-cause mortality and serious bleeding. RESULTS: A total of 12 155 patients were randomized: 6040 to bivalirudin (52.3% with a post-PCI bivalirudin infusion), and 6115 to heparin (53.2% with planned glycoprotein IIb/IIIa inhibitor use). Thirty-day mortality was not significantly different between bivalirudin and heparin (1.2% versus 1.1%; adjusted odds ratio, 1.24 [95% CI, 0.86-1.79]; P=0.25). Cardiac mortality, reinfarction, and stent thrombosis rates were also not significantly different. Bivalirudin reduced serious bleeding (both access site-related and non-access site-related) compared with heparin (3.3% versus 5.5%; adjusted odds ratio, 0.59; 95% CI, 0.48-0.72; P<0.0001). Outcomes were consistent regardless of use of a post-PCI bivalirudin infusion or routine lycoprotein IIb/IIIa inhibitor use with heparin and during 1-year follow-up. CONCLUSIONS: In patients with non-ST-segment-elevation myocardial infarction undergoing PCI, procedural anticoagulation with bivalirudin and heparin did not result in significantly different rates of mortality or ischemic events, including stent thrombosis and reinfarction. Bivalirudin reduced serious bleeding compared with heparin arising both from the access site and nonaccess sites.
Asunto(s)
Infarto del Miocardio , Infarto del Miocardio sin Elevación del ST , Intervención Coronaria Percutánea , Trombosis , Humanos , Heparina/efectos adversos , Infarto del Miocardio sin Elevación del ST/tratamiento farmacológico , Anticoagulantes/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Hirudinas/efectos adversos , Fragmentos de Péptidos/efectos adversos , Hemorragia/etiología , Trombosis/etiología , Proteínas Recombinantes/efectos adversos , Resultado del TratamientoRESUMEN
Mitral regurgitation is the most common valvular disease and is estimated to affect over 5 million Americans. Real-world data collection contributes to safety and effectiveness evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, and clinical best practice research. We aimed to establish a minimum core data set in mitral interventions to promote efficient, reusable real-world data collection for all of these purposes. Two expert task forces separately evaluated and reconciled a list of candidate elements derived from: 1) 2 ongoing transcatheter mitral trials; and 2) a systemic literature review of high-impact mitral trials and U.S multicenter, multidevice registries. From 703 unique data elements considered, unanimous consensus agreement was achieved on 127 "core" data elements, with the most common reasons for exclusion from the minimum core data set being burden or difficulty in accurate assessment (41.2%), duplicative information (25.0%), and low likelihood of affecting outcomes (19.6%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established and implemented into the national Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapies Registry 127 interoperable, reusable core data elements to support more efficient, consistent, and informative transcatheter mitral device evidence for regulatory submissions, safety surveillance, best practice development, and hospital quality assessments.
Asunto(s)
Cardiología , Medicare , Anciano , Humanos , Estados Unidos , Resultado del Tratamiento , Catéteres , Centers for Medicare and Medicaid Services, U.S. , Estudios Multicéntricos como AsuntoRESUMEN
Background: Oral anticoagulation (OAC) has been considered the standard of care for stroke prophylaxis for patients with nonvalvular atrial fibrillation; however, many individuals are unable or unwilling to take long-term OAC. The safety and efficacy of percutaneous left atrial appendage closure (LAAC) have been controversial, and new trial data have recently emerged. We therefore sought to perform an updated meta-analysis of randomized clinical trials (RCTs) comparing OAC to percutaneous LAAC, focusing on individual clinical endpoints. Methods: We performed a systematic search of the MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials from January 2000 through December 2021 for all RCTs comparing percutaneous LAAC to OAC in patients with nonvalvular atrial fibrillation. Fixed and random effects meta-analyses of hazard ratios (HRs) were performed using the longest follow-up duration available by intention-to-treat. The prespecified primary endpoint was all-cause mortality. Results: Three RCTs enrolling 1516 patients were identified. The weighted mean follow-up was 54.7 months. LAAC was associated with a reduced risk of all-cause mortality (HR 0.76; 95% confidence interval [CI], 0.59-0.96; p = 0.023), hemorrhagic stroke (HR 0.24; 95% CI, 0.09-0.61; p = 0.003), and major nonprocedural bleeding (HR 0.52; 95% CI, 0.37-0.74; p < 0.001). There was no significant difference between LAAC and OAC for any other endpoints. Conclusions: The available evidence from RCTs suggests LAAC therapy is associated with reduced long-term risk of death compared with OAC. This may be driven by reductions in hemorrhagic stroke and major nonprocedural bleeding. There were no significant differences in the risk of all stroke. Further large-scale clinical trials are needed to validate these findings.
RESUMEN
Background The neutrophil-to-lymphocyte ratio (NLR) as a marker of systemic inflammation has been associated with worse prognosis in several chronic disease states, including heart failure. However, few data exist on the prognostic impact of elevated baseline NLR or change in NLR levels during follow-up in patients undergoing transcatheter or surgical aortic valve replacement (TAVR or SAVR) for aortic stenosis. Methods and Results NLR was available in 5881 patients with severe aortic stenosis receiving TAVR or SAVR in PARTNER (Placement of Aortic Transcatheter Valves) I, II, and S3 trials/registries (median [Q1, Q3] NLR, 3.30 [2.40, 4.90]); mean NLR, 4.10; range, 0.5-24.9) and was evaluated as continuous variable and categorical tertiles (low: NLR ≤2.70, n=1963; intermediate: NLR 2.70-4.20, n=1958; high: NLR ≥4.20, n=1960). No patients had known baseline infection. High baseline NLR was associated with increased risk of death or rehospitalization at 3 years (58.4% versus 41.0%; adjusted hazard ratio [aHR], 1.39; 95% CI, 1.18-1.63; P<0.0001) compared with those with low NLR, irrespective of treatment modality. In both patients treated with TAVR and patients treated with SAVR, NLR decreased between baseline and 2 years. A 1-unit observed decrease in NLR between baseline and 1 year was associated with lower risk of death or rehospitalization between 1 year and 3 years (aHR, 0.86; 95% CI, 0.82-0.89; P<0.0001). Conclusions Elevated baseline NLR was independently associated with increased subsequent mortality and rehospitalization after TAVR or SAVR. The observed decrease in NLR after TAVR or SAVR was associated with improved outcomes. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT00530894, NCT0134313, NCT02184442, NCT03225001, NCT0322141.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Linfocitos , Neutrófilos , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del TratamientoRESUMEN
Transcatheter aortic valve replacement (TAVR) is the standard of care for severe, symptomatic aortic stenosis. Real-world TAVR data collection contributes to benefit/risk assessment and safety evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, as well as clinical research and real-world implementation through appropriate use criteria. The essential minimum core dataset for these purposes has not previously been defined but is necessary to promote efficient, reusable real-world data collection supporting quality, regulatory, and clinical applications. The authors performed a systematic review of the published research for high-impact TAVR studies and U.S. multicenter, multidevice registries. Two expert task forces, one from the Predictable and Sustainable Implementation of National Cardiovascular Registries/Heart Valve Collaboratory and another from The Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry convened separately and then met to reconcile a final list of essential data elements. From 276 unique data elements considered, unanimous consensus agreement was achieved on 132 "core" data elements, with the most common reasons for exclusion from the minimum core dataset being burden or difficulty in accurate assessment (36.9%), duplicative information (33.3%), and low likelihood of affecting outcomes (10.7%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established 132 interoperable, reusable essential core data elements essential to supporting more efficient, consistent, and informative TAVR device evidence for regulatory submissions, safety surveillance, best practice, and hospital quality assessments.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Humanos , Medicare , Estudios Multicéntricos como Asunto , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados UnidosRESUMEN
Transcatheter aortic valve replacement (TAVR) is the standard of care for severe, symptomatic aortic stenosis. Real-world TAVR data collection contributes to benefit/risk assessment and safety evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, as well as clinical research and real-world implementation through appropriate use criteria. The essential minimum core dataset for these purposes has not previously been defined but is necessary to promote efficient, reusable real-world data collection supporting quality, regulatory, and clinical applications. The authors performed a systematic review of the published research for high-impact TAVR studies and U.S. multicenter, multidevice registries. Two expert task forces, one from the Predictable and Sustainable Implementation of National Cardiovascular Registries/Heart Valve Collaboratory and another from The Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry convened separately and then met to reconcile a final list of essential data elements. From 276 unique data elements considered, unanimous consensus agreement was achieved on 132 "core" data elements, with the most common reasons for exclusion from the minimum core dataset being burden or difficulty in accurate assessment (36.9%), duplicative information (33.3%), and low likelihood of affecting outcomes (10.7%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established 132 interoperable, reusable essential core data elements essential to supporting more efficient, consistent, and informative TAVR device evidence for regulatory submissions, safety surveillance, best practice, and hospital quality assessments.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Medicare , Estudios Multicéntricos como Asunto , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estados UnidosRESUMEN
OBJECTIVES: This study sought to determine correlates and consequences of contrast-associated acute kidney injury (CA-AKI) on clinical outcomes in patients with or without pre-existing chronic kidney disease (CKD). BACKGROUND: The incidence and impact of CA-AKI on clinical outcomes during contemporary percutaneous coronary intervention (PCI) are not fully defined. METHODS: The ADAPT-DES (Assessment of Dual AntiPlatelet Therapy With Drug Eluting Stents) study was a prospective, multicenter registry of 8,582 patients treated with ≥1 drug-eluting stent(s). CA-AKI was defined as a post-PCI increase in serum creatinine of >0.5 mg/dL or a relative increase of ≥25% compared with pre-PCI. CKD was defined as estimated glomerular filtration rate <60 mL/min/1.73 m2. The primary endpoint was the 2-year rate of net adverse clinical events (NACE): All-cause mortality, myocardial infarction (MI), definite or probable stent thrombosis, or major bleeding. RESULTS: Of 7287 (85%) patients with evaluable data, 476 (6.5%) developed CA-AKI. In a multivariable model, older age, female sex, Caucasian race, congestive heart failure, diabetes, hypertension, CKD, presentation with ST-segment elevation MI, Killip class II to IV, radial access, intra-aortic balloon pump use, hypotension, and number of stents were independent predictors of CA-AKI. The 2-year NACE rate was higher in patients with CA-AKI (adjusted HR: 1.88; 95% CI: 1.42-2.49), as was each component of NACE (all-cause mortality, HR: 1.77; 95% CI: 1.22-2.55; MI, HR: 1.67; 95% CI: 1.18-2.36; definite/probable stent thrombosis, HR: 1.71; 95% CI: 1.10-2.65; and major bleeding, HR: 1.38; 95% CI: 1.06-1.80). Compared with the CA-AKI-/CKD- group, the CA-AKI+/CKD- (HR: 1.83; 95% CI: 1.33-2.52), CA-AKI-/CKD+ (HR: 1.56; 95% CI: 1.15-2.13), CA-AKI+/CKD+ (HR: 3.29; 95% CI: 1.92-5.67), and maintenance dialysis (HR: 2.67; 95% CI: 1.65-4.31) groups were at higher risk of NACE. CONCLUSIONS: CA-AKI was relatively common after contemporary PCI and was associated with increased 2-year rates of NACE. Patients with pre-existing CKD were at particularly high risk for NACE after CA-AKI.
Asunto(s)
Lesión Renal Aguda , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Insuficiencia Renal Crónica , Trombosis , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/epidemiología , Medios de Contraste/efectos adversos , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Trombosis/etiología , Resultado del TratamientoRESUMEN
OBJECTIVES: Incidence and prognosis of ST-segment elevation myocardial infarction (STEMI) vary according to ambient temperature and season. We sought to assess whether season and temperature on the day of STEMI are associated with infarct size, microvascular obstruction (MVO), left ventricular ejection fraction (LVEF) and clinical outcomes after primary percutaneous coronary intervention (PCI). METHODS: Individual patient data from 1598 patients undergoing primary PCI in six randomized clinical trials were pooled. Infarct size was evaluated by cardiac magnetic resonance within 30 days in all trials. Patients were categorized either by whether they presented on a day of temperature extremes (minimum temperature <0 °C or maximum temperature >25 °C) or according to season. RESULTS: A total of 558/1598 (34.9%) patients presented with STEMI on a day of temperature extremes, and 395 (24.7%), 374 (23.4%), 481 (30.1%) and 348 (21.8%) presented in the spring, summer, fall and winter. After multivariable adjustment, temperature extremes were independently associated with larger infarct size (adjusted difference 2.8%; 95% CI, 1.3-4.3; P < 0.001) and smaller LVEF (adjusted difference -2.3%; 95% CI, -3.5 to -1.1; P = 0.0002) but not with MVO (adjusted P = 0.12). In contrast, infarct size, MVO and LVEF were unrelated to season (adjusted P = 0.67; P = 0.36 and P = 0.95, respectively). Neither temperature extremes nor season were independently associated with 1-year risk of death or heart failure hospitalization (adjusted P = 0.79 and P = 0.90, respectively). CONCLUSION: STEMI presentation during temperature extremes was independently associated with larger infarct size and lower LVEF but not with MVO after primary PCI, whereas season was unrelated to infarct severity.
Asunto(s)
Microcirculación/fisiología , Infarto del Miocardio/fisiopatología , Infarto del Miocardio con Elevación del ST/complicaciones , Temperatura , Función Ventricular Izquierda/fisiología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Pronóstico , Infarto del Miocardio con Elevación del ST/fisiopatología , Resultado del TratamientoRESUMEN
BACKGROUND: Moderate or worse paravalvular regurgitation (PVR) post transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The mechanisms by which this occurs are not fully understood. AIMS: The aim of this study was to determine the mechanism by which PVR leads to worse outcomes. METHODS: A total of 1,974 intermediate-risk patients who received TAVR in the PARTNER 2 trial and registries were grouped by PVR severity. Clinical and echocardiographic outcomes were compared. RESULTS: Overall 1,176 (60%) patients had none/trace, 680 (34%) had mild, and 118 (6%) had ≥moderate PVR. At two years, ≥moderate PVR patients had increased risks of all-cause (HR 2.33 [1.41-3.85], p-value=0.001) and cardiovascular death (HR 3.30 [1.74-6.28], p-value <0.001), rehospitalisation (HR 2.68 [1.57-4.58], p-value <0.001), and reintervention (HR 14.72 [3.13-69.32], p-value <0.001). Moderate or worse PVR was associated with larger increases in left ventricular (LV) end-diastolic and systolic dimensions and volumes, LV mass indices, and reductions in LV ejection fractions (LVEFs) from 30 days to two years. Mild PVR was not associated with worse outcomes. Adjusting for LV dimensions and LVEF from the one-year echocardiogram, patients with ≥moderate PVR still had an increased risk of all-cause death or rehospitalisation at two years (HR 2.84 [1.25-5.78], p-value=0.009). CONCLUSIONS: Moderate or worse PVR, but not mild PVR, is associated with an increased risk of all-cause and cardiovascular death, rehospitalisation, and reintervention at two years. Moderate or worse PVR is also associated with adverse LV remodelling, which partially mediates how ≥moderate PVR leads to worse outcomes. These results provide dual insights on the deleterious impact of ≥moderate PVR and the contributing mechanisms of poor clinical outcomes.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
BACKGROUND: Prior studies have reported an association between elevated white blood cell count (WBCc) and worse clinical outcomes after coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI). We assessed the prognostic impact of WBCc in patients undergoing revascularization for left main coronary artery disease (LMCAD). METHODS: In Evaluation of XIENCE Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL), 1905 patients with LMCAD and low or intermediate SYNTAX scores were randomized to PCI with everolimus-eluting stents versus CABG. The 1895 patients with baseline WBCc available were grouped in tertiles of WBCc (mean 5.6 ± 0.8, 7.5 ± 0.5, and 10.1 ± 1.6 × 109/L). RESULTS: Five-year rates of the primary endpoint (death, myocardial infarction or stroke) were similar across increasing WBCc tertiles (21.2, 18.9, and 21.6%; P = 0.46). Individual components of the primary endpoint, Bleeding Academic Research Consortium (BARC) 3-5 bleeding, stent thrombosis or graft occlusion and ischemia-driven revascularization were all similar across WBCc tertiles. By multivariable analysis, WBCc as a continuous variable was not an independent predictor of adverse events (hazard radio per 1 × 109/L: 1.02; 95% CI, 0.97-1.08; P = 0.43). Results were consistent in the PCI and CABG arms individually. CONCLUSION: There was no association between baseline WBCc and 30-day or 5-year clinical outcomes after PCI or CABG. The absence of a clear incremental increase in events with increasing WBCc in the current analysis indicates that WBCc should not routinely be used as a prognostic marker or to guide revascularization decisions in patients with LMCAD.
Asunto(s)
Vasos Coronarios/fisiopatología , Recuento de Leucocitos/estadística & datos numéricos , Revascularización Miocárdica/normas , Evaluación de Resultado en la Atención de Salud/estadística & datos numéricos , Anciano , Femenino , Humanos , Recuento de Leucocitos/métodos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/métodos , Revascularización Miocárdica/estadística & datos numéricos , Evaluación de Resultado en la Atención de Salud/métodos , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/normas , Intervención Coronaria Percutánea/estadística & datos numéricos , Factores de Riesgo , Resultado del TratamientoRESUMEN
BACKGROUND: There is a paucity of data regarding the effect of inhibition of the renin-angiotensin system on outcomes after percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG). We sought to examine long-term outcomes of patients with left main coronary disease (LMCAD) randomized to PCI with fluoropolymer-based cobalt-chromium everolimus-eluting stents or CABG according to treatment at discharge with angiotensin-converting enzyme inhibitors (ACEI) or angiotensin receptor blockers (ARB) in the large-scale, multicenter, randomized EXCEL trial. METHODS: EXCEL randomized 1905 patients with LMCAD of low and intermediate anatomical complexity (visually-assessed SYNTAX score ≤32) to PCI (n = 948) versus CABG (n = 957). Patients were categorized according to whether they were treated with ACEI/ARB at discharge; their outcomes from discharge to 5 years were examined using multivariable logistic regression with an offset for follow-up time. RESULTS: Among 1775 patients discharged alive with known ACEI/ARB treatment status, 896 (50.5%) were treated with one of these agents. Among those treated with ACEI/ARB, the 5-year rate of all-cause death was similar after PCI or CABG (10.7% versus 9.8% respectively, adjOR, 0.94; 95% CI, 0.56-1.57) in contrast to patients not treated with ACEI/ARB (15.0% versus 7.8%, respectively, adjOR, 2.20; 95% CI, 1.32-3.67) (Pinteraction = 0.02). Significant interactions between treatment arm (PCI versus CABG) and ACEI/ARB treatment status were also found for cardiovascular death (Pinteraction = 0.03), ischemia-driven revascularization (Pinteraction = 0.03), target vessel revascularization (Pinteraction = 0.007) and target vessel failure (Pinteraction = 0.0009). CONCLUSION: In the EXCEL trial, the postdischarge rates of death and revascularization after 5 years were similar after PCI and CABG in patients with LMCAD treated with ACEI/ARB at discharge. In contrast, event rates were higher after PCI versus CABG in those not so treated.
Asunto(s)
Antagonistas de Receptores de Angiotensina/farmacología , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Anciano , Antagonistas de Receptores de Angiotensina/administración & dosificación , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/estadística & datos numéricos , Sistema Renina-Angiotensina/efectos de los fármacos , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: Transcatheter tricuspid valve-in-valve (TViV) and valve in-ring (TViR) implantation have become a viable therapy for a failed tricuspid bioprosthesis. Here we report short (thirty days) and long (one-year) term clinical outcomes of ten patients who underwent TViV at our institution. METHODS: The electronic databases of New York Presbyterian Columbia Medical Center were retrospectively reviewed for cases of transcatheter tricuspid valve replacement (TViV or TViR). Between 2012 and 2019, data from ten patients who underwent TViV were collected. The primary safety outcome was procedure-related adverse events, including clinically evident cardiac perforation, new pericardial effusion and sustained ventricular arrhythmia. The primary efficacy endpoint was defined as successful valve deployment with total (paravalvular or intravalvular) tricuspid regurgitation (TR) estimated as mild or less. Results are descriptive in nature. RESULTS: A total of ten patients who underwent TViV were included in the study. Of them, 40% presented with isolated tricuspid bioprosthetic stenosis (TS), 20% with isolated TR and 40% with mixed TS and TR. All patients were treated with the SAPIEN valve (first generation, XT, or Sapien 3). The TViV procedure was successful in all patients, and no immediate post-replacement paravalvular leak (PVL) or intra-procedural complications were reported. The primary safety and efficacy endpoints were met in all patients. At thirty-days, all patients were alive and reported significant improvements in symptoms and functional status. CONCLUSIONS: Transcatheter tricuspid valve implantation is a safe and effective therapy for degenerative tricuspid bioprosthesis.