Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Adv Mater ; : e2313381, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38647215

RESUMEN

Aggregation-induced emission luminogen (AIEgen)-functionalized organic-inorganic hybrid nanoparticles (OINPs) are an emerging category of multifunctional nanomaterials with vast potential applications. The spatial arrangement and positioning of AIEgens and inorganic compounds in AIEgen-functionalized OINPs determine the structures, properties, and functionalities of the self-assembled nanomaterials. In this work, a facile and general emulsion self-assembly tactic for synthesizing well-defined AIEgen-functionalized OINPs is proposed by coassembling alkane chain-functionalized inorganic nanoparticles with hydrophobic organic AIEgens. As a proof of concept, the self-assembly and structural evolution of plasmonic-fluorescent hybrid nanoparticles (PFNPs) from concentric circle to core shell and then to Janus structures is demonstrated by using alkane chain-modified AuNPs and AIEgens as building blocks. The spatial position of AuNPs in the signal nanocomposite is controlled by varying the alkane ligand length and density on the AuNP surface. The mechanism behind the formation of various PFNP nanostructures is also elucidated through experiments and theoretical simulation. The obtained PFNPs with diverse structures exhibit spatially tunable optical and photothermal properties for advanced applications in multicolor and multimode immunolabeling and photothermal sterilization. This work presents an innovative synthetic approach of constructing AIEgen-functionalized OINPs with diverse structures, compositions, and functionalities, thereby championing the progressive development of these OINPs.

2.
Food Chem ; 447: 138997, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-38513493

RESUMEN

Herein we developed a multicolor lateral flow immunoassay (LFIA) test strip for rapid and simultaneous quantitative detection of aflatoxin B1 (AFB1) and zearalenone (ZEN). Three differently colored aggregation-induced emission nanoparticles (AIENPs) were designed as LFIA signal tags, with red and green AIENPs for targeting AFB1 and ZEN at the test line, and yellow AIENPs for indicating the validity of the test strip at the control (C) line. After surface functionalization with antibodies, the developed AIENP-based multicolor LFIA allows simultaneous and accurate quantification of AFB1 and ZEN using an independent C-line assisted ratiometric signal output strategy. The detection limits of AFB1 and ZEN were 6.12 and 26 pg/mL, respectively. The potential of this method for real-world applications was well demonstrated in corn and wheat. Overall, this multicolor LFIA shows great potential for field screening of multiple mycotoxins and can be extended to rapid and simultaneous monitoring of other small molecule targets.


Asunto(s)
Nanopartículas del Metal , Micotoxinas , Zearalenona , Zearalenona/análisis , Aflatoxina B1/análisis , Anticuerpos Monoclonales , Micotoxinas/análisis , Inmunoensayo/métodos , Límite de Detección , Contaminación de Alimentos/análisis
3.
ACS Nano ; 17(15): 14347-14405, 2023 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-37486125

RESUMEN

Light has profoundly impacted modern medicine and healthcare, with numerous luminescent agents and imaging techniques currently being used to assess health and treat diseases. As an emerging concept in luminescence, aggregation-induced emission (AIE) has shown great potential in biological applications due to its advantages in terms of brightness, biocompatibility, photostability, and positive correlation with concentration. This review provides a comprehensive summary of AIE luminogens applied in imaging of biological structure and dynamic physiological processes, disease diagnosis and treatment, and detection and monitoring of specific analytes, followed by representative works. Discussions on critical issues and perspectives on future directions are also included. This review aims to stimulate the interest of researchers from different fields, including chemistry, biology, materials science, medicine, etc., thus promoting the development of AIE in the fields of life and health.


Asunto(s)
Colorantes Fluorescentes , Sustancias Luminiscentes , Colorantes Fluorescentes/química , Luminiscencia , Diagnóstico por Imagen , Atención a la Salud
4.
Biosensors (Basel) ; 13(4)2023 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37185496

RESUMEN

Hg2+ contamination in sewage can accumulate in the human body through the food chains and cause health problems. Herein, a novel aggregation-induced emission luminogen (AIEgen)-encapsulated hydrogel probe for ultrasensitive detection of Hg2+ was developed by integrating hydrophobic AIEgens into hydrophilic hydrogels. The working mechanism of the multi-fluorophore AIEgens (TPE-RB) is based on the dark through-bond energy transfer strategy, by which the energy of the dark tetraphenylethene (TPE) derivative is completely transferred to the rhodamine-B derivative (RB), thus resulting in intense photoluminescent intensity. The spatial networks of the supporting hydrogels further provide fixing sites for the hydrophobic AIEgens to enlarge accessible reaction surface for hydrosoluble Hg2+, as well create a confined reaction space to facilitate the interaction between the AIEgens and the Hg2+. In addition, the abundant hydrogen bonds of hydrogels further promote the Hg2+ adsorption, which significantly improves the sensitivity. The integrated TPE-RB-encapsulated hydrogels (TR hydrogels) present excellent specificity, accuracy and precision in Hg2+ detection in real-world water samples, with a 4-fold higher sensitivity compared to that of pure AIEgen probes. The as-developed TR hydrogel-based chemosensor holds promising potential as a robust, fast and effective bifunctional platform for the sensitive detection of Hg2+.


Asunto(s)
Mercurio , Humanos , Hidrogeles , Colorantes Fluorescentes/química , Iones , Adsorción
5.
J Agric Food Chem ; 71(10): 4408-4416, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36866978

RESUMEN

Highly luminescent nanospheres have been demonstrated in enhancing the sensitivity of lateral flow immunoassay (LFIA) due to their loading numerous luminescent dyes. However, the photoluminescence intensities of existing luminescent nanospheres are limited due to the aggregation-caused quenching effect. Herein, highly luminescent aggregation-induced emission luminogens embedded nanospheres (AIENPs) with red emission were introduced as signal amplification probes of LFIA for quantitative detection of zearalenone (ZEN). Optical properties of red-emitted AIENPs were compared with time-resolved dye-embedded nanoparticles (TRNPs). Results showed that red-emitted AIENPs have stronger photoluminescence intensity on the nitrocellulose membrane and superior environmental tolerance. Additionally, we benchmarked the performance of AIENP-LFIA against TRNP-LFIA using the same set of antibodies, materials, and strip readers. Results showed that AIENP-LFIA exhibits good dynamic linearity with the ZEN concentration from 0.195 to 6.25 ng/mL, with half competitive inhibitory concentration (IC50) and detection of limit (LOD) at 0.78 and 0.11 ng/mL, respectively. The IC50 and LOD are 2.07- and 2.36-fold lower than those of TRNP-LFIA. Encouragingly, the precision, accuracy, specificity, practicality, and reliability of this AIENP-LFIA for ZEN quantitation were further characterized. The results verified that the AIENP-LFIA has good practicability for the rapid, sensitive, specific, and accurate quantitative detection of ZEN in corn samples.


Asunto(s)
Nanopartículas del Metal , Nanosferas , Zearalenona , Zearalenona/análisis , Luminiscencia , Contaminación de Alimentos/análisis , Reproducibilidad de los Resultados , Inmunoensayo/métodos , Límite de Detección , Nanopartículas del Metal/química
6.
Anal Chim Acta ; 1247: 340869, 2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36781245

RESUMEN

Organic fluorescein dye-embedded fluorescent microspheres (FMs) are currently the most established commercially fluorescent markers, and they have been widely used to improve the sensitivity of immunochromatography assay (ICA). However, these FMs have natural defects, such as the aggregation-caused quenching effect and small Stokes shift, which are not conducive to improving the detection performance of ICA. Herein, two green emitted FMs, namely aggregation-induced emission FMs (AIEFMs) and fluorescein isothiocyanate FMs (FITCFMs), were prepared by swelling the AIE luminogens and FITC dyes into the carboxyl group-modified polystyrene microspheres. The average diameters of AIEFMs and FITCFMs were 350 and 450 nm, respectively. Compared with FITCFMs, the AIEFMs exhibited stronger fluorescence intensity and a larger Stokes shift. These two FMs were used as the labeling markers of ICA for procalcitonin (PCT) detection with the sandwich format. Among them, AIEFM-ICA showed dynamic linear detection of PCT from 7.6 pg mL-1 to 125 ng mL-1 with the limit of detection (LOD) at 3.8 pg mL-1. These values were remarkably superior to those of FITCFM-ICA (linear range from 61 pg mL-1 to 62.5 ng mL-1 and LOD value at 60 pg mL-1). Furthermore, the average recoveries of the intra- and inter-assays of AIEFM-ICA ranged from 86% to 112%, with coefficients of variation ranging from 1.2% to 8.8%, indicating accuracy and precision for PCT quantitative detection. Additionally, the reliability of the developed AIEFM-ICA was further assessed by analyzing 30 real serum samples from systemic inflammatory response by infectious diseases, and the results showed good agreement with the chemiluminescence immunoassay. In conclusion, compared with traditional FITCFMs, green emitted AIEFMs as a novel fluorescent label, exhibits greater potential to enhance the detection performance of the ICA platform.


Asunto(s)
Colorantes , Luminiscencia , Microesferas , Reproducibilidad de los Resultados , Cromatografía de Afinidad/métodos , Fluoresceínas , Inmunoensayo/métodos
7.
Food Chem ; 412: 135580, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-36736185

RESUMEN

Herein, we report a novel aggregation-induced emission nanoparticles (AIENPs)-based immunochromatography assay (ICA) platform to detect ochratoxin A (OTA) using orange-yellow-emitting AIENPs as fluorescent nanoprobes. Immunochromatographic strip is used for the quantitative detection of OTA in crop matrix using AIENPs coupled with anti-OTA ascites. Under optimal conditions, AIENPs-ICA exhibits stronger signal output capacity and higher sensitivity than traditional gold nanoparticles-based ICA. The half-maximal inhibitory concentration is as low as 0.149 ng mL-1, and the limit detection is 0.042 ng mL-1 at 10 % competitive inhibition concentration. The average recovery of AIENPs-ICA ranges from 82.60 % to 113.14 % with the coefficient of variation ranging from 1.26 % to 11.57 %, proving the proposed method possesses good reliability and reproducibility. Moreover, the developed AIENPs-ICA exhibits negligible cross-reactions with other mycotoxins. We believe the presented AIENPs-ICA platform holds promising potential as a powerful tool for on-site detection of OTA and other molecules detection in food samples.


Asunto(s)
Nanopartículas del Metal , Ocratoxinas , Oro/química , Zea mays/química , Reproducibilidad de los Resultados , Cromatografía de Afinidad/métodos , Límite de Detección , Nanopartículas del Metal/química , Ocratoxinas/análisis
8.
Toxins (Basel) ; 15(2)2023 01 29.
Artículo en Inglés | MEDLINE | ID: mdl-36828428

RESUMEN

Staphylococcal enterotoxin A (SEA) has presented enormous difficulties in dairy food safety and the sensitive detection of SEA provides opportunities for effective food safety controls and staphylococcal food poisoning tracebacks. Herein, a novel aggregation-induced emission (AIE)-based sandwich lateral flow immunoassay (LFIA) was introduced to detect SEA by using red-emissive AIE nanoparticles (AIENPs) as the fluorescent nanoprobe. The nanoprobe was constructed by directly immobilising antibodies on boronate-tagged AIENPs (PBA-AIENPs) via a boronate affinity reaction, which exhibited a high SEA-specific affinity and remarkable fluorescent performance. Under optimal conditions, the ultrasensitive detection of SEA in pasteurised milk was achieved within 20 min with a limit of detection of 0.04 ng mL-1. The average recoveries of the PBA-AIENP-LFIA ranged from 91.3% to 117.6% and the coefficient of variation was below 15%. It was also demonstrated that the PBA-AIENP-LFIA had an excellent selectivity against other SE serotypes. Taking advantage of the excellent sensitivity of this approach, real chicken and salad samples were further analysed, with a high versatility and accuracy. The proposed PBA-AIENP-LFIA platform shows promise as a potent tool for the identification of additional compounds in food samples as well as an ideal test method for on-site detections.


Asunto(s)
Nanopartículas del Metal , Nanopartículas , Animales , Enterotoxinas/análisis , Inmunoensayo/métodos , Leche/química , Límite de Detección , Oro
9.
Mikrochim Acta ; 190(2): 56, 2023 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-36645516

RESUMEN

Ultrabright green-emissive AIE nanoparticles (AIENPs) were used as signal-amplification probes to enhance the detectability of lateral flow immunoassay (LFIA). The detection performances of the green-emissive AIENP probes in both sandwich and competitive LFIA formats were systematically evaluated. Benefiting from its remarkable fluorescent brightness, the developed AIENP-LFIA showed versatile applicability for the detection of small molecules and macromolecules by using ochratoxin A (OTA) and procalcitonin (PCT) as model analytes, respectively. Under the optimum conditions, the detection limits (LODs) of the fabricated AIENP-LFIA for OTA and PCT were 0.043 ng mL-1 and 0.019 ng mL-1, respectively. These LOD values are significantly lower than those of conventional LFIA methods using gold nanoparticles as signal reporters. In addition, we demonstrated the practical application potential of AIENP-LFIA for the detection of OTA in real maize samples and PCT in real serum samples. These results indicated that the ultrabright green-emissive AIENPs were promising as signal output materials for building high-performance LFIA platform and broadening the application scenarios of LFIA.


Asunto(s)
Nanopartículas del Metal , Oro , Inmunoensayo/métodos
10.
Toxins (Basel) ; 15(1)2023 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-36668898

RESUMEN

Lateral flow immunoassay (LFIA) based on fluorescent microbeads has attracted much attention for its use in rapid and accurate food safety monitoring. However, conventional fluorescent microbeads are limited by the aggregation-caused quenching effect of the loaded fluorophores, thus resulting in low signal intensity and insufficient sensitivity of fluorescent LFIA. In this study, a green-emitting fluorophore with an aggregation-induced emission (AIE) characteristic was encapsulated in polymer nanoparticles via an emulsification technique to form ultrabright fluorescent microbeads (denoted as AIEMBs). The prepared AIEMBs were then applied in a competitive LFIA (AIE-LFIA) as signal reporters for the rapid and highly sensitive screening of fumonisin B1 (FB1) in real corn samples. High sensitivity with a detection limit of 0.024 ng/mL for FB1 was achieved by the developed AIE-LFIA. Excellent selectivity, good accuracy, and high reliability of the AIE-LFIA were demonstrated, indicating a promising platform for FB1 screening.


Asunto(s)
Oro , Nanopartículas del Metal , Reproducibilidad de los Resultados , Microesferas , Inmunoensayo/métodos , Límite de Detección
11.
J Dairy Sci ; 105(6): 4938-4945, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35465994

RESUMEN

Staphylococcal enterotoxin A (SEA) is an important biotoxin, produced by Staphylococcus aureus under appropriate conditions, and often contaminates milk and dairy products. Herein, an anti-SEA monoclonal antibody (anti-SEA mAb) was prepared by injecting the SEA protein in BALB/c mice, and a novel immunochromatographic assay (ICA) was developed for the rapid and sensitive determination of SEA in pasteurized milk by using highly luminescent quantum dot beads (QB) as signal amplification probe. Given the 1020-fold enhancement in the photoluminescence intensity of QB to the original quantum dot, the proposed QB-ICA exhibits high sensitivity for SEA determination in real milk samples with a limit of detection of 1.89 ng/mL, and shows good dynamic linearity for SEA quantitative detection from 2 to 150 ng/mL within 15 min of test time. The proposed QB-ICA also shows good selectivity to SEA detection with a negligible cross-reaction to common analogs, including staphylococcal enterotoxins B, C, D, and E. In addition, the accuracy and precision of QB-ICA were assessed by analyzing SEA-fortified milk samples. The average recoveries of intra- and interassays range from 85.5 to 128.1%, and the coefficients of variation range from 4.6 to 14.2%, indicating an acceptable accuracy for the quantitative detection of SEA in real milk samples. In summary, this work provides a powerful and rapid analysis tool for the sensitive monitoring of SEA contamination in pasteurized milk samples.


Asunto(s)
Puntos Cuánticos , Animales , Cromatografía de Afinidad/métodos , Cromatografía de Afinidad/veterinaria , Enterotoxinas/análisis , Inmunoensayo/veterinaria , Ratones , Leche/química , Puntos Cuánticos/química
12.
Theranostics ; 12(6): 2801-2810, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35401815

RESUMEN

Background: Gold nanoparticle-based immunochromatographic assay (AuNP-ICA) has insufficient sensitivity due to its inherent colorimetric signal intensity and low capture efficiency of AuNPs. The metal in situ growth is a common strategy to enhance the sensitivity of AuNP-ICA due to its superior signal amplification potential and simple operation. However, the detection distortion caused by metal self-nucleation during the growth process can seriously affect the accuracy and reproducibility of the strips. Methods: We present a pH-regulated gold in situ growth (GISG) strategy to amplify the colorimetric signal and demonstrate its application in improving the performance of traditional AuNP-ICA. The controllable growth signal amplification is achieved by lowering the pH of the growth solution to weaken the reducibility of hydroxylamine (HA), thus urging the crystallization and growth of Au3+ on the AuNP surface instead of free reduction and self-nucleation. In addition, the mechanism of pH regulation on HA reducibility is elucidated by introducing an electron-donating or electron-withdrawing group to affect the electron density of hydroxyl group. Results: The proposed GISG strategy shows improved sensitivity, low background, robust operation, and good reproducibility. The LOD values of the designed GISG-amplified AuNP-ICA are as low as 0.0198 ng mL-1 for hepatitis B surface antigen and 0.0125 ng mL-1 for HIV-1 capsid p24 antigen, which are lower by about 500- and 70-fold, respectively, than those of the unamplified AuNP-ICA. Conclusions: This method is extended to enable ultrasensitive and rapid diagnosis of viral infections, and has potential as a general signal amplification platform to redefine immunochromatographic diagnostics.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Colorimetría , Oro/química , Concentración de Iones de Hidrógeno , Nanopartículas del Metal/química , Reproducibilidad de los Resultados
13.
Foods ; 11(7)2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35407018

RESUMEN

Herein, we developed a paper-based smart sensing chip for the real-time, visual, and non-destructive monitoring of food freshness using a ratiometric aggregation-induced emission (AIE) luminogen (i.e., H+MQ, protonated 4-(triphenylamine)styryl)quinoxalin-2(1H)-one) as pH sensitive indicators. Upon exposure to amine vapors, the deprotonation of H+MQ occurs and triggers its color change from blue to yellow, with the fluorescence redshift from blue to amaranth. Consequently, we successfully achieved the sensitive detection of ammonia vapors by recording the bimodal color and fluorescence changes. Given the high sensitivity of H+MQ to ammonia vapor, a paper-based smart sensor chip was prepared by depositing H+MQ on the commercial qualitative filter paper through a physical deposition strategy. After being placed inside the sealed containers, the developed H+MQ-loaded paper chip was applied to the real-time monitoring of biogenic amine contents according to its color difference and ratio fluorescence change. The detection results were further compared with those obtained by the high-performance liquid chromatography method, which verified the feasibility of the designed paper chip for the food spoilage degree evaluation. Briefly, this work indicates that the designed H+MQ-loaded paper chip could be a promising approach for improving food freshness monitoring.

14.
ACS Nano ; 16(2): 3351-3361, 2022 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-35137583

RESUMEN

Colorimetric lateral flow immunoassay (LFIA) with gold nanoparticles (AuNPs) as signal reporters has been widely used in point-of-care testing. Nonetheless, the potential of traditional AuNP-based LFIA for the early diagnosis of disease is often compromised by limited sensitivity due to the insufficient colorimetric signal brightness of AuNPs. Herein, we develop a "three-in-one" multifunctional catalytic colorimetric nanohybrid (Fe3O4@MOF@Pt) composed of Fe3O4 nanoparticles, MIL-100(Fe), and platinum (Pt) nanoparticles. Fe3O4@MOF@Pt displays enhanced colorimetric signal brightness, fast magnetic response, and ultrahigh peroxidase-mimicking activity, which are beneficial to the enhancement of the sensitivity of LFIA by coupling with magnetic separation and catalytic amplification. When integrated with the dual-antibody sandwich LFIA platform, the developed Fe3O4@MOF@Pt can achieve an ultrasensitive immunochromatographic assay of procalcitonin with a sensitivity of 0.5 pg mL-1, which is approximately 2280-fold higher than that of conventional AuNP-based LFIA and superior to previously published immunoassays. Therefore, this work suggests that the proposed catalytic colorimetric nanohybrid can act as promising signal reporters to enable ultrasensitive immunochromatographic disease diagnostics.


Asunto(s)
Colorimetría , Nanopartículas del Metal , Colorimetría/métodos , Oro/química , Inmunoensayo/métodos , Fenómenos Magnéticos , Nanopartículas del Metal/química
15.
Theranostics ; 12(2): 574-602, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34976202

RESUMEN

Lateral flow immunoassay (LFIA) with gold nanoparticles (AuNPs) as signal reporters is a popular point-of-care diagnostic technique. However, given the weak absorbance of traditional 20-40 nm spherical AuNPs, their sensitivity is low, which greatly limits the wide application of AuNP-based LFIA. With the rapid advances in materials science and nanotechnology, the synthesis of noble metal nanoparticles (NMNPs) has enhanced physicochemical properties such as optical, plasmonic, catalytic, and multifunctional activity by simply engineering their physical parameters, including the size, shape, composition, and external structure. Using these engineered NMNPs as an alternative to traditional AuNPs, the sensitivity of LFIA has been significantly improved, thereby greatly expanding the working range and application scenarios of LFIA, particularly in trace analysis. Therefore, in this review, we will focus on the design of engineered NMNPs and their demonstration in improving LFIA. We highlight the strategies available for tailoring NMNP designs, the effect of NMNP engineering on their performance, and the working principle of each engineering design for enhancing LFIA. Finally, current challenges and future improvements in this field are briefly discussed.


Asunto(s)
Inmunoensayo/instrumentación , Nanopartículas del Metal/química , Ingeniería Química , Diseño de Fármacos , Oro , Humanos , Magnetismo , Fenómenos Ópticos , Tamaño de la Partícula
16.
Foods ; 10(7)2021 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-34198969

RESUMEN

BACKGROUND: Colloidal gold based lateral flow immunoassay (LFIA) commonly suffers from relatively low detection sensitivity due to the insufficient brightness of conventional gold nanoparticles (AuNPs) with the size of 20-40 nm. METHODS: Herein, three kinds of gold nanobeads (GNBs) with the size of 94 nm, 129 nm, and 237 nm, were synthesized by encapsulating numerous hydrophobic AuNPs (10 nm) into polymer matrix. The synthesized GNBs exhibited the enhanced colorimetric signal intensity compared with 20-40 nm AuNPs. The effects of the size of GNBs on the sensitivity of LFIA with competitive format were assessed. RESULTS: The results showed that the LFIA using 129 nm GNBs as amplified signal probes exhibits the best sensitivity for fumonisin B1 (FB1) detection with a cut-off limit (for visual qualitative detection) at 125 ng/mL, a half maximal inhibitory concentration at 11.27 ng/mL, and a detection limit at 1.76 ng/mL for detection of real corn samples, which are 8-, 3.82-, and 2.89-fold better than those of conventional AuNP40-based LFIA, respectively. The developed GNB-LFIA exhibited negligible cross-reactions with other common mycotoxins. In addition, the accuracy, precision, reliability, and practicability were demonstrated by determining real corn samples. CONCLUSIONS: All in all, the proposed study provides a promising strategy to enhance the sensitivity of competitive LFIA via using the GNBs as amplified signal probes.

17.
Anal Chim Acta ; 1168: 338623, 2021 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-34052002

RESUMEN

The analytical performance of immunochromatographic assay (ICA) is usually determined by the biological activity of antibody and gold nanoparticle conjugates (AuNP probes). However, conventional probes are constructed using the nondirectional coupling method that can cause the improper orientation of antibodies with the poor accessibility of antigen-binding sites. To address these issues, we report a site-specific directional coupling strategy to enhance the bioactivity of AuNP probes through the specific covalent binding of the aldehyde group in the Fc domain of antibodies with the hydrazide group modified on the surface of AuNPs. Through this design, the antibodies can be erected on the AuNP surface to fully expose the Fab domain and achieve the maximized functional availability. Leveraging these AuNP probes as ICA labels, we demonstrate an improved detection of the hepatitis B surface antigen with less used amount of labeled antibody (0.2 mg/pmol AuNPs), shorter reaction time (10 min), better antibody bioactivity, and higher detection sensitivity (2 ng/mL) compared with the carbodiimide method. Overall, this work provides great promise for the design and the construction of high-performance probes to enhance the detection performance of ICA sensors.


Asunto(s)
Oro , Nanopartículas del Metal , Anticuerpos , Antígenos , Inmunoensayo
18.
Front Med (Lausanne) ; 8: 759514, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35186964

RESUMEN

BACKGROUND: The elderly is a vulnerable group susceptible to toxic environmental factors; however, the association between unsafe water and osteoarthritis (OA) incident among this population is poorly investigated. This study aimed to examine the effects of drinking water sources on OA risk in the Chinese elderly population. METHODS: Data were obtained from the China Longitudinal Healthy Longevity Survey to perform a 16-year longitudinal study. All participants aged ≥65 years at baseline were potentially eligible. Information on drinking water sources was recorded via a structured questionnaire. The water source was classified as well, surface, spring, or tap. OA was selected as the health outcome. Cox proportional hazard models, adjusted socio-demographics, lifestyle, and chronic disease were used to estimate the hazard ratio (HR) for OA. Subgroup analyses were performed to assess the potential interactive effect. RESULTS: A total of 12,543 participants were included. With restriction to the longest follow-up time, the mean survival time of follow-up was 14.56 years. Among the cohort members, 1,585 members suffered from OA. In the full model, drinking from well water and spring water was associated with a higher risk of OA compared with drinking from tap water (HR: 1.37, 95% CI: 1.22-1.54; HR: 1.34, 95% CI: 1.03-1.74). Except for age, the effects of modifications from socioeconomic status, lifestyles, and health conditions were non-significant (p for interaction <0.05). After multiple imputations for missing data and excluding deaths in the first year of follow-up and participants with a history of the disease and using the Shared-frailty Cox model, sensitivity analysis indicated a robust association between the drinking water source and OA incidence. CONCLUSION: Drinking tap water was associated with a low risk of OA among older adults in China. The use of clean water sources as a marker of decreased OA and arthritis risks must be revisited in low- and middle-income countries.

19.
Food Chem ; 336: 127710, 2021 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-32763739

RESUMEN

Conventional gold nanoparticle-based lateral flow immunoassay (LFIA) usually suffers a huge challenge in measuring target concentration in food matrices with dark color because of its poor resistance to the background matrix and color interference. To address this issue, we first report a novel bifunctional magneto-gold nanohybrid (MGNH) for the simultaneous magnetic separation and colorimetric target sensing by integrating MGNHs into LFIA. Under optimum conditions, an ultrasensitive detection of ochratoxin A (OTA) in grape juice was achieved with a limit of detection at 0.094 ng mL-1. The average recoveries of this MGNH-LFIA ranged from 92.31% to 108.97% with a coefficient of variation of below 12%. The excellent selectivity of our MGNH-LFIA against OTA was demonstrated. Besides, our MGNH-LFIA is comparable to liquid chromatography coupled with mass spectrometry in terms of accuracy, reproducibility, and practicability. The designed MGNH-LFIA platform is readily extended for improving other small molecule detection in food samples.


Asunto(s)
Contaminación de Alimentos/análisis , Jugos de Frutas y Vegetales/análisis , Inmunoensayo/métodos , Nanopartículas del Metal/química , Ocratoxinas/análisis , Análisis de los Alimentos/instrumentación , Análisis de los Alimentos/métodos , Oro/química , Inmunoensayo/instrumentación , Límite de Detección , Fenómenos Magnéticos , Ocratoxinas/inmunología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrofotometría Ultravioleta , Vitis/química
20.
Anal Chim Acta ; 1141: 136-143, 2021 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-33248647

RESUMEN

The use of luminescent nanobeads to improve the sensitivity of sandwich immunochromatographic assay (ICA) has obtained increasing concern. Illustrating the relationship among luminescent intensity, nanobead size, nitrocellulose membrane aperture, and ICA sensitivity is important for achieving the optimal target detection. Thus, we synthesized six differently sized quantum dot beads (QBs) (95, 140, 180, 235, 325, and 405 nm) as ICA labels and applied them in three aperture membranes (10, 15, and 25 µm). Results indicate that increasing the QB size to less than an appropriate size of 235 nm is beneficial for ICA sensitivity because of the increased fluorescence. However, oversized QBs result in reduced sensitivity due to the decreased diffusion or settlement of the QB on the membrane that causes obvious background signal. The small aperture membrane perfectly matching the QB size contributes to ICA sensitivity by decreasing the migration velocity of the QB probe for increased binding of the QB@analyte complex at the T zone. Consequently, the best detection of hepatitis B surface antigen with a sensitivity of 0.156 ng/mL is achieved using 235 nm QBs in 15 µm membrane. Further performance evaluation of our QB235-ICACN95 demonstrates excellent accuracy, selectivity, and practicability. This work provides a new idea to manipulate the sensitivity of sandwich ICA by tuning the QB size and the membrane aperture, and a theoretical guidance for selecting the probe and membrane to achieve the best detection of target analytes.


Asunto(s)
Puntos Cuánticos , Inmunoensayo , Luminiscencia , Porosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA