Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
JBJS Case Connect ; 14(3)2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39146447

RESUMEN

CASE: We present a unique case of a 45-year-old man with his right middle finger embedded with rings. Limited finger flexion was noted because of flexor tendon injury caused by the dorsal migration of the embedded ring through joint. The rings were removed under anesthesia, resulting in the resolution of swelling and recover of osseous structure. Follow-up examinations revealed no residual edema or numbness, indicating preserved neurovascularization, despite the dorsal migration of the ring. CONCLUSION: Our unique case reveals continuous finger ring migration without compromising neurovascular bundles, with review of 30 cases emphasizing the importance of psychiatric consultation. Timely intervention yielded nearly half of patients achieving full recovery.


Asunto(s)
Articulaciones de los Dedos , Humanos , Masculino , Persona de Mediana Edad , Traumatismos de los Dedos/cirugía , Migración de Cuerpo Extraño/diagnóstico por imagen
2.
BMC Musculoskelet Disord ; 25(1): 559, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39026178

RESUMEN

BACKGROUND: The inclusion of a connecting path in a porous implant can promote nutrient diffusion to cells and enhance bone ingrowth. Consequently, this study aimed to evaluate the biomechanical, radiographic, and histopathological performance of a novel 3D-printed porous suture anchor in a rabbit femur model. METHODS: Three test groups were formed based on the type of suture anchor (SA): Commercial SA (CSA, Group A, n = 20), custom solid SA (CSSA, Group B, n = 20), and custom porous SA (CPSA, Group C, n = 20). The SAs were implanted in the lateral femoral condyle of the right leg in each rabbit. The rabbits (New Zealand white rabbits, male, mean body weight of 2.8 ± 0.5 kg, age 8 months) underwent identical treatment and were randomized into experimental and control groups via computer-generated randomization. Five rabbits (10 femoral condyles) were euthanized at 0, 4, 8, and 12 weeks post-implantation for micro-CT, histological analysis, and biomechanical testing. RESULTS: At 12 weeks, the CPSA showed a higher BV/TV (median 0.7301, IQR 0.7276-0.7315) than the CSSA and CSA. The histological analysis showed mineralized osteocytes near the SA. At 4 weeks, new bone was observed around the CPSA and had penetrated its porous structure. By 12 weeks, there was no significant difference in ultimate failure load between the CSA and CPSA. CONCLUSIONS: We demonstrated that the innovative 3D-printed porous suture anchor exhibited comparable pullout strength to conventional threaded suture anchors at the 12-week postoperative time-point period. Furthermore, our porous anchor design enhanced new bone formation and facilitated bone growth into the implant structure, resulting in improved biomechanical stability.


Asunto(s)
Fémur , Impresión Tridimensional , Anclas para Sutura , Titanio , Animales , Conejos , Fémur/cirugía , Fémur/diagnóstico por imagen , Fémur/patología , Porosidad , Masculino , Fenómenos Biomecánicos , Microtomografía por Rayos X
3.
Carbohydr Polym ; 339: 122174, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38823938

RESUMEN

Segmental bone defects can arise from trauma, infection, metabolic bone disorders, or tumor removal. Hydrogels have gained attention in the field of bone regeneration due to their unique hydrophilic properties and the ability to customize their physical and chemical characteristics to serve as scaffolds and carriers for growth factors. However, the limited mechanical strength of hydrogels and the rapid release of active substances have hindered their clinical utility and therapeutic effectiveness. With ongoing advancements in material science, the development of injectable and biofunctionalized hydrogels holds great promise for addressing the challenges associated with segmental bone defects. In this study, we incorporated lyophilized platelet-rich fibrin (LPRF), which contains a multitude of growth factors, into a genipin-crosslinked gelatin/hyaluronic acid (GLT/HA-0.5 % GP) hydrogel to create an injectable and biofunctionalized composite material. Our findings demonstrate that this biofunctionalized hydrogel possesses optimal attributes for bone tissue engineering. Furthermore, results obtained from rabbit model with segmental tibial bone defects, indicate that the treatment with this biofunctionalized hydrogel resulted in increased new bone formation, as confirmed by imaging and histological analysis. From a translational perspective, this biofunctionalized hydrogel provides innovative and bioinspired capabilities that have the potential to enhance bone repair and regeneration in future clinical applications.


Asunto(s)
Regeneración Ósea , Liofilización , Gelatina , Ácido Hialurónico , Hidrogeles , Iridoides , Fibrina Rica en Plaquetas , Animales , Iridoides/química , Iridoides/farmacología , Gelatina/química , Conejos , Hidrogeles/química , Hidrogeles/farmacología , Ácido Hialurónico/química , Ácido Hialurónico/farmacología , Regeneración Ósea/efectos de los fármacos , Fibrina Rica en Plaquetas/química , Ingeniería de Tejidos/métodos , Reactivos de Enlaces Cruzados/química , Andamios del Tejido/química , Tibia/efectos de los fármacos , Tibia/cirugía
4.
BMC Infect Dis ; 24(1): 293, 2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38448866

RESUMEN

BACKGROUND: Colorectal cancer is one of the most frequently diagnosed forms of cancer, and it is associated with several common symptoms and signs such as rectal bleeding, altered bowel habits, abdominal pain, anemia, and unintentional weight loss. Sciatica, a debilitating condition in which the patient experiences paresthesia and pain in the dermatome of associated lumbosacral nerve roots or sciatic nerve distribution, is not considered one of these. Here we present a case of colorectal cancer manifesting symptoms of sciatica alone. CASE PRESENTATION: A 68-year-old male presented with progressive lower back pain radiating to his left thigh and calf over L5/S1 dermatome. Sciatica was suspected and initially underwent conservative treatment with analgesics. However, the symptoms progressed and MRI revealed an epidural abscess surprisingly. Surgical debridement was performed and pus culture isolated Streptococcus gallolyticus. Based on the strong association of S. gallolyticus with colorectal cancer, the presence of this pathogen prompted further tumor evaluation, even in the absence of the typical symptoms and signs. This investigation ultimately leads to the diagnosis of sigmoid adenocarcinoma. CONCLUSIONS: Although rare, sciatica caused by S. gallolyticus infection of the spinal epidural space may serve as the initial presentation of colorectal cancer. Physicians should be aware of the strong association between S. gallolyticus and colorectal cancer. Based on what we currently know about the condition; a thorough systematic assessment of occult neoplasia for patients with S. gallolyticus infection is recommended.


Asunto(s)
Neoplasias del Colon , Absceso Epidural , Ciática , Masculino , Humanos , Anciano , Ciática/diagnóstico , Ciática/etiología , Absceso Epidural/diagnóstico , Absceso Epidural/cirugía , Neoplasias del Colon/complicaciones , Neoplasias del Colon/diagnóstico , Dolor Abdominal , Concienciación
5.
J Chin Med Assoc ; 87(4): 400-409, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38335463

RESUMEN

BACKGROUND: Acute kidney injury (AKI) is a severe postoperative complication associated with poor clinical outcomes, including the development of chronic kidney disease (CKD) and death. This study aimed to investigate the incidence and determinants of AKI following elective surgeries for degenerative lumbar spine disease. METHODS: All patient data were extracted from the US Nationwide Inpatient Sample database. After surgery, AKI's incidence and risk factors were identified for lumbar degenerative disease. ICD-9 and ICD-10 codes defined lumbar spine degenerative disease, fusion, decompression, and AKI. The study cohort was categorized by type of surgery, that is, decompression alone or spinal fusion. Regression analysis was used to identify associations between AKI and risk factors organized by surgery type. RESULTS: The incidence of AKI after decompression or fusion was 1.1% and 1.8%, respectively. However, the incidence of AKI in the United States is rising. The strongest predictor of AKI was underlying CKD, which was associated with an 9.0- to 12.9-fold more significant risk of AKI than in subjects without comorbid CKD. In this setting, older age, congestive heart failure, anemia, obesity, coagulopathy and hospital-acquired infections were also strong predictors of AKI. In contrast, long-term aspirin/anticoagulant usage was associated with lowered AKI risk. CONCLUSION: Findings of this study inform risk stratification for AKI and may help to optimize treatment decisions and care planning after elective surgery for lumbar degenerative disease.


Asunto(s)
Lesión Renal Aguda , Insuficiencia Renal Crónica , Humanos , Estados Unidos/epidemiología , Incidencia , Pacientes Internos , Factores de Riesgo , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Estudios Retrospectivos
6.
Diagnostics (Basel) ; 13(23)2023 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-38066773

RESUMEN

A medial meniscus posterior root tear (MMPRT) contributes to knee joint degeneration. Arthroscopic transtibial pullout repair (ATPR) may restore biomechanical integrity for load transmission. However, degeneration persists after ATPR in certain patients, particularly those with preoperative subchondral insufficiency fracture of the knee (SIFK). We explored the relationship between preoperative SIFK and osteoarthritis (OA) progression in retrospectively enrolled patients who were diagnosed as having an MMPRT and had received ATPR within a single institute. Based on their preoperative magnetic resonance imaging (MRI), these patients were then categorized into SIFK and non-SIFK groups. OA progression was evaluated by determining Kellgren-Lawrence (KL) grade changes and preoperative and postoperative median joint widths. SIFK characteristics were quantified using Image J (Version 1.52a). Both groups exhibited significant post-ATPR changes in medial knee joint widths. The SIFK group demonstrated significant KL grade changes (p < 0.0001). A larger SIFK size in the tibia and a greater lesion-to-tibia length ratio in the coronal view were positively correlated with more significant KL grade changes (p = 0.008 and 0.002, respectively). Thus, preoperative SIFK in patients with an MMPRT was associated with knee OA progression. Moreover, a positive correlation was observed between SIFK lesion characteristics and knee OA progression.

7.
BMC Musculoskelet Disord ; 24(1): 863, 2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-37932751

RESUMEN

BACKGROUND: Surgeons are routinely required to remove loose or failed pedicle screws and insert a new screw in their place. However, inserting a new screw into an existing hole may compromise the holding capacity of the pedicle screw. The purpose of this study is to evaluate the pullout strength of pedicle screws with different thread designs after the primary insertion and revision surgery in a synthetic bone model. METHODS: Four pedicle screws with different thread designs (single-lead-thread (SLT) screw, dual-lead-thread (DLT) screw, mixed-single-lead-thread (MSLT) screw, and proximal-unthreaded-dual-thread (PUDL) screw) were inserted into pre-drilled, untapped holes (ø 4.2 mm, length 35 mm) in Sawbone blocks of density 20 pcf. In the first sequence, a 6.0 mm screw was inserted into the predrilled foam block and the primary pullout strength of the screw was measured according to ASTM F543. In the second sequence, a 6.0 mm screw was inserted and removed, and then either a 6.5 mm screw of the same design or a different screw design was inserted into the same hole and the pullout strength recorded. RESULTS: In the first sequence, the mean pullout strength of the MSLT screw was significantly (p < 0.05) greater than all other screw designs. In the second sequence, when the MSLT screw was the primary screw, using a larger MSLT screw (6.5 mm) as the revision screw did not lead to a higher pullout strength than if a 6.0 mm diameter PUDL screw was used for the revision. Using a larger DLT screw (6.5 mm) as the revision screw resulted in a significantly (p < 0.05) greater pullout strength than a 6.0 mm STL, DLT, MSLT, or PUDL screw. CONCLUSIONS: Our results indicate that employing classic oversizing of the same screw design is a safe choice for maintaining screw purchase in the bone after revision. In cases where oversizing with the same screw design is not practical, opting for a PUDL screw with the same original diameter can provide enough purchase in the bone to maintain stability.


Asunto(s)
Tornillos Pediculares , Humanos , Ensayo de Materiales , Poliuretanos , Huesos , Fenómenos Biomecánicos
8.
Diagnostics (Basel) ; 13(17)2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37685327

RESUMEN

(1) Background: Proximal humerus fractures can be a debilitating condition if not properly treated. These fracture patterns are varied and differ in every patient. Functional outcomes may be determined by the integrity of the shoulder girdle involving the rotator cuff insertion. The post-operative resorption or malreduction of the greater tuberosity (GT) is an important factor contributing to the poor functional outcome of a patient. Thus, we intend to evaluate the cause-and-effect relationship between GT complications and clinical prognosis and outcomes. (2) Methods: A single-center retrospective comparative study was performed to evaluate the functional outcomes of patients undergoing operative fixation for this injury. A total of 387 consecutive cases treated operatively from 2019-2021 were included for analysis. (3) Results: 94 cases fulfilled our criteria for analysis. A matched-group comparison of 19 patients each was performed to compare demographics, post-operative fracture characteristics and clinical outcomes. (4) Conclusions: The resorption or malreduction of the GT contributes greatly to the prognostic outcome in patients treated with open reduction and internal fixation (ORIF) surgery. In our demographic study, obesity is another contributing factor affecting the parameters of post-operative reduction in proximal humerus fractures. Appropriate surgical planning and post-operative multidisciplinary care must be taken into consideration to attain a satisfactory prognostic outcome.

9.
J Geriatr Oncol ; 14(7): 101597, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37542948

RESUMEN

INTRODUCTION: We aimed to investigate the prognostic determinants of life-threatening and fatal complications in patients <80 and ≥ 20 years of age and those ≥80 years who were undergoing surgery for spinal metastases. MATERIALS AND METHODS: Based on data between 2005 and 2018 extracted from National Inpatient Sample as the largest longitudinal hospital inpatient databases in the United States, statistical analyses were performed to identify prognostic factors (age, sex, household income, insurance status, major comorbidities, primary site of malignancy, types of surgery, surgical approaches, types of hospital admission, and hospital-related characteristics) for major and fatal perioperative complications among older adult patients. RESULTS: A total of 31,925 patients aged ≥ 20y who were undergoing surgery for spinal metastasis were identified (< 80 y: n = 28,448; ≥ 80 y: n = 35,37). After adjustment, age ≥80 y was significantly associated with greater risk of perioperative cardiac arrest (adjusted odds ratio [aOR]: 1.34, 95% confidence interval [CI]: 1.03-1.73) and acute kidney injury (AKI) (aOR: 1.23, 95% CI: 1.07-1.41) but lower risk of venous thromboembolic event (VTE) (aOR: 0.80, 95% CI: 0.66-0.96) than <80y. Factors predicting life-threatening complications among patients ≥ 80y were: male sex (<80 y: aOR = 1.14; ≥ 80 y: aOR = 1.35), higher score on Charlson Comorbidity Index (CCI) (80 y, aOR = 1.21-2.67; ≥ 80 y: aOR = 1.25-2.55), open surgery (<80 y: aOR = 1.24; ≥ 80 y: aOR = 1.35), and greater Metastatic Spinal Tumor Frailty Index (MSTFI) (<80 y: aOR = 2.48-10.03; ≥ 80 y: aOR = 2.69-11.21). Among patients <80y, factors predicting life-threatening complications were: male sex, Black race, greater CCI score, primary tumor at kidney, hematologic cancer, other/unspecified primary site, certain surgical procedures, open surgery, greater MSTFI, emergent admission, and low hospital volume. DISCUSSION: This study identifies a list of independent risk factors for the presence of life-threatening complications among patients <80 and ≥ 80y who were undergoing surgery for spinal metastasis. The findings contribute to the development of clinical strategies for the surgical management of spinal metastasis, especially for octogenarians, and lower the risk of unfavorable inpatient outcomes.


Asunto(s)
Neoplasias de la Columna Vertebral , Anciano de 80 o más Años , Humanos , Masculino , Estados Unidos/epidemiología , Anciano , Neoplasias de la Columna Vertebral/cirugía , Pacientes Internos , Hospitalización , Comorbilidad , Factores de Riesgo , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos
10.
Bioengineering (Basel) ; 10(6)2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37370591

RESUMEN

Pullout strength is an important indicator of the performance and longevity of pedicle screws and can be heavily influenced by the screw design, the insertion technique and the quality of surrounding bone. The purpose of this study was to investigate the pullout strength of three different pedicle screws inserted using three different strategies and with two different loading conditions. Three pedicle screws with different thread designs (single-lead-thread (SLT) screw, dual-lead-thread (DLT) screw and mixed-single-lead-thread (MSLT) screw) were inserted into a pre-drilled rigid polyurethane foam block using three strategies: (A) screw inserted to a depth of 33.5 mm; (B) screw inserted to a depth of 33.5 mm and then reversed by 3.5 mm to simulate an adjustment of the tulip height of the pedicle screw and (C) screw inserted to a depth of 30 mm. After insertion, each screw type was set up with and without a cyclic load being applied to the screw head prior to the pullout test. To ensure that the normality assumption is met, we applied the Shapiro-Wilk test to all datasets before conducting the non-parametric statistical test (Kruskal-Wallis test combined with pairwise Mann-Whitney-U tests). All screw types inserted using strategy A had a significantly greater pullout strength than those inserted using strategies B and C, regardless of if the screw was pre-loaded with a cyclic load prior to testing. Without the use of the cyclic pre-load, the MSLT screw had a greater pullout strength than the SLT and DLT screws for all three insertion strategies. However, the fixation strength of all screws was reduced when pre-loaded before testing, with the MSLT screw inserted using strategy B producing a significantly lower pullout strength than all other groups (p < 0.05). In contrast, the MSLT screw using insertion strategies A and C had a greater pullout strength than the SLT and DLT screws both with and without pre-loading. In conclusion, the MSLT pedicle screw exhibited the greatest pullout strength of the screws tested under all insertion strategies and loading conditions, except for insertion strategy B with a cyclic pre-load. While all screw types showed a reduced pullout strength when using insertion strategy B (screw-out depth adjustment), the MSLT screw had the largest reduction in pullout strength when using a pre-load before testing. Based on these findings, during the initial screw insertion, it is recommended to not fully insert the screw thread into the bone and to leave a retention length for depth adjustment to avoid the need for screw-out adjustment, as with insertion strategy B.

11.
Am J Sports Med ; 51(3): 642-655, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36752674

RESUMEN

BACKGROUND: We assessed the efficacy of a novel platelet-rich fibrin (PRF)-augmented repair strategy for promoting biological healing of an anterior cruciate ligament (ACL) midsubstance tear in a rabbit model. The biological gap-bridging effect of a PRF scaffold alone or in combination with rabbit ligamentocytes on primary ACL healing was evaluated both in vitro and in vivo. HYPOTHESIS: A PRF matrix can be implanted as a provisional fibrin-platelet bridging scaffold at an ACL defect to facilitate functional healing. STUDY DESIGN: Controlled laboratory study. METHODS: The biological effects of PRF on primary rabbit ligamentocyte proliferation, tenogenic differentiation, migration, and tendon-specific matrix production were investigated for treatment of cells with PRF-conditioned medium (PRFM). Three-dimensional (3D) lyophilized PRF (LPRF)-cell composite was fabricated by culturing ligamentocytes on an LPRF patch for 14 days. Cell-scaffold interactions were investigated under a scanning electron microscope and through histological analysis. An ACL midsubstance tear model was established in 3 rabbit groups: a ruptured ACL was treated with isolated suture repair in group A, whereas the primary repair was augmented with LPRF and LPRF-cell composite to bridge the gap between ruptured ends of ligaments in groups B and C, respectively. Outcomes-gross appearance, magnetic resonance imaging, and histological analysis-were evaluated in postoperative weeks 8 and 12. RESULTS: PRFM promoted cultured ligamentocyte proliferation, migration, and expression of tenogenic genes (type I and III collagen and tenascin). PRF was noted to upregulate cell tenogenic differentiation in terms of matrix production. In the 3D culture, viable cells formed layers at high density on the LPRF scaffold surface, with notable cell ingrowth and abundant collagenous matrix depositions. Moreover, ACL repair tissue and less articular cartilage damage were observed in knee joints in groups B and C, implying the existence of a chondroprotective phenomenon associated with PRF-augmented treatment. CONCLUSION: Our PRF-augmented strategy can facilitate the formation of stable repair tissue and thus provide gap-bridging in ACL repair. CLINICAL RELEVANCE: From the translational viewpoint, effective primary repair of the ACL may enable considerable advancement in therapeutic strategy for ACL injuries, particularly allowing for proprioception retention and thus improved physiological joint kinematics.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Fibrina Rica en Plaquetas , Animales , Conejos , Ligamento Cruzado Anterior/cirugía , Ligamento Cruzado Anterior/patología , Articulación de la Rodilla/cirugía , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/patología , Colágeno
12.
Medicina (Kaunas) ; 58(6)2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35744071

RESUMEN

Background and Objectives: Using an appropriate torque to tighten set screws ensures the long-term stability of spinal posterior fixation devices. However, the recommended torque often varies between different devices and some devices do not state a recommended torque level. The purpose of this study is to evaluate the effect of set screw torque on the overall construct stability and fatigue life. Materials and Methods: Two commercial pedicle screw systems with different designs for the contact interface between the set screw and rod (Group A: plane contact, Group B: line contact) were assembled using torque wrenches provided with the devices to insert the set screws and tighten to the device specifications. The axial gipping capacity and dynamic mechanical stability of each bilateral construct were assessed in accordance with ASTM F1798 and ASTM F1717. Results: Increasing or decreasing the torque on the set screw by 1 Nm from the recommended level did not have a significant effect on the axial gripping capacity or fatigue strength of Group A (p > 0.05). For Group B, over-tightening the set screw by 1 Nm did cause a significant reduction in the fatigue strength. Conclusions: Excessive torque can damage the rod surface and cause premature failure. When insertion using a manual driver is preferred, a plane contact interface between the set screw and rod can reduce damage to the rod surface when the set screw is over-torqued.


Asunto(s)
Tornillos Pediculares , Fenómenos Biomecánicos , Humanos , Columna Vertebral/cirugía , Torque
13.
BMC Musculoskelet Disord ; 21(1): 100, 2020 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-32059656

RESUMEN

BACKGROUND: Lumbar spinal fusion with rigid spinal fixators as one of the high risk factors related to adjacent-segment failure. The purpose of this study is to investigate how the material properties of spinal fixation rods influence the biomechanical behavior at the instrumented and adjacent levels through the use of the finite element method. METHODS: Five finite element models were constructed in our study to simulate the human spine pre- and post-surgery. For the four post-surgical models, the spines were implanted with rods made of three different materials: (i) titanium rod, (ii) PEEK rod with interbody PEEK cage, (iii) Biodegradable rod with interbody PEEK cage, and (iv) PEEK cage without pedicle screw fixation (no rods). RESULTS: Fusion of the lumbar spine using PEEK or biodegradable rods allowed a similar ROM at both the fusion and adjacent levels under all conditions. The models with PEEK and biodegradable rods also showed a similar increase in contact forces at adjacent facet joints, but both were less than the model with a titanium rod. CONCLUSIONS: Flexible rods or cages with non-instrumented fusion can mitigate the increased contact forces on adjacent facet joints typically found following spinal fixation, and could also reduce the level of stress shielding at the bone graft.


Asunto(s)
Trasplante Óseo/métodos , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Fijadores Internos , Modelos Anatómicos , Tornillos Pediculares , Fusión Vertebral/métodos , Implantes Absorbibles , Fenómenos Biomecánicos , Humanos , Vértebras Lumbares/cirugía , Región Lumbosacra/cirugía , Rango del Movimiento Articular , Titanio , Articulación Cigapofisaria/cirugía
14.
PLoS One ; 14(11): e0224699, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31675364

RESUMEN

Pedicle screws are commonly used for posterior stabilization of the spine. When used in deformed or degenerated segments, the pedicle screws are often not fully inserted into the bone, but instead the threaded portion is exposed by 1 or 2 threads to accommodate rod placement and ensure alignment between the tulip of the screw and the rod. However, broken pedicle screws have been reported with the use of this method. The aim of this study was to determine how the fatigue life of the screw is affected by not fully inserting the screw into the bone. Spinal constructs were evaluated in accordance with ASTM F1717. The following three screw positions were subjected to compression bending fatigue loading; (i) pedicle screw fully inserted in the test block with no threads exposed (EXP-T0), (ii) pedicle screw inserted with one thread exposed outside the test block (EXP-T1), (iii) pedicle screw inserted with two threads exposed outside the test block (EXP-T2). Corresponding finite element models FEM-T0, FEM-T1 and FEM-T2 were also constructed and subjected to the same axial loading as the experimental groups to analyze the stress distribution in the pedicle screws and rods. The results showed that under a 190 N axial load, the EXP-T0 group survived the full 5 million cycles, the EXP-T1 group failed at 3.7 million cycles on average and the EXP-T2 groups failed at 1.0 million cycles on average, while the fatigue strength of both the EXP-T1 and EXP-T2 groups was 170 N. The constructs failed through fracture of the pedicle screw. In comparison to the FEM-T0 model, the maximum von Mises stress on the pedicle screw in the FEM-T1 and FEM-T2 models increased by 39% and 58%, respectively. In conclusion, this study demonstrated a drastic decrease in the fatigue life of pedicle screws when they are not full inserted into the plastic block.


Asunto(s)
Tornillos Pediculares/efectos adversos , Falla de Prótesis/etiología , Fenómenos Biomecánicos , Fuerza Compresiva , Análisis de Falla de Equipo , Humanos , Columna Vertebral/cirugía , Soporte de Peso
15.
Medicine (Baltimore) ; 98(26): e16230, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31261580

RESUMEN

BACKGROUND: Effective treatment of low back pain (LBP) originating in the lumbar and sacroiliac joints is difficult to achieve. The objective of the current study was to compare the clinical effectiveness of radiofrequency (RF) neurotomy versus conservative nonsurgical approaches for the management of chronic lumbar and sacroiliac joint pain. METHODS: The PICOS framework was adhered to (P [population]: patients with a history of chronic function-limiting lumbar and sacroiliac joint pain lasting at least 6 months; I [intervention]: RF neurotomy; C [comparator]: other nonsurgical treatments; O [outcomes]: the Oswestry Disability Index (ODI), measurement for pain, and a quality of life (QoL) questionnaire; S [study design]: meta-analysis). Two trained investigators systematically searched Medline, Cochrane, EMBASE, and ISI Web of Knowledge databases for relevant studies published in English through March 2019. RESULTS: Patients treated with RF neurotomy (n = 528) had significantly greater improvement in ODI scores, pain scores and QoL measured by EQ-5D compared with controls (n = 457); however, significant heterogeneity was observed when data were pooled from eligible studies. In subgroup analyses, patients who received RF neurotomy had a significantly greater improvement in ODI scores compared with those with sham treatment. Patients treated with RF achieved significantly greater improvement in pain scores compared with controls who received sham treatment or medical treatment. In a subgroup analysis of pain in the sacroiliac joint and in lumbar facet joints, the RF neurotomy group achieved a significantly greater improvement in ODI score and pain scores compared with the control group. The ODI score and pain score were improved after 2 months of follow up in the analyses stratified by follow-up duration. CONCLUSIONS: Use of RF neurotomy as an intervention for chronic lumbar and sacroiliac joint pain led to improved function; however, larger, more directly comparable studies are needed to confirm this study's findings.


Asunto(s)
Artralgia/terapia , Dolor Crónico/terapia , Tratamiento Conservador , Desnervación , Dolor de la Región Lumbar/terapia , Articulación Sacroiliaca , Humanos , Resultado del Tratamiento
16.
PLoS One ; 14(2): e0211676, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30716122

RESUMEN

The majority of compressive vertebral fractures in osteoporotic bone occur at the level of the thoracolumbar junction. Immediate decompression is often required in order to reduce the extent of neurological damage. This study evaluated four fixation methods for decompression in patients with thoracolumbar burst fractures, and presented the most suitable method for osteoporotic patients. A finite element model of a T7-L5 spinal segment was created and subjected to an L1 corpectomy to simulate a serious burst fracture. Five models were tested: a) intact spine; 2) two segment fixation (TSF), 3) up-three segment fixation (UTSF), below-three segment fixation (BTSF), and four segment fixation (FSF). The ROM, stiffness and compression ratio of the fractured vertebra were recorded under various loading conditions. The results of this study showed that the ROM of the FSF model was the lowest, and the ROMs of UTSF and BTSF models were similar but still greater than the TSF model. Decreasing the BMD to simulate osteoporotic bone resulted in a ROM for the four instrumented models that was higher than the normal bone model. Of all models, the FSF model had the highest stiffness at T12-L2 in extension and lateral bending. Similarly, the compression ratio of the FSF model at L1 was also higher than the other instrumented models. In conclusion, FSF fixation is suggested for patients with osteoporotic thoracolumbar burst fractures. For patients with normal bone quality, both UTSF and BTSF fixation provide an acceptable stiffness in extension and lateral bending, as well as a favorable compression ratio at L1.


Asunto(s)
Vértebras Lumbares/cirugía , Osteoporosis/cirugía , Fracturas Osteoporóticas/cirugía , Fracturas de la Columna Vertebral/cirugía , Vértebras Torácicas/cirugía , Fenómenos Biomecánicos/fisiología , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Fracturas por Compresión/cirugía , Humanos
17.
Reg Anesth Pain Med ; 43(4): 425-433, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29394211

RESUMEN

BACKGROUND AND OBJECTIVES: This study is a meta-analysis of randomized controlled trials comparing the efficacy of transcutaneous electrical nerve stimulation (TENS) to a control and to other nerve stimulation therapies (NSTs) for the treatment of chronic back pain. METHODS: Citations were identified in MEDLINE, the Cochrane Library, Google Scholar, and ClinicalTrials.gov through June 2014 using the following keywords: nerve stimulation therapy, transcutaneous electrical nerve stimulation, back pain, chronic pain. Control treatments included sham, placebo, or medication only. Other NSTs included electroacupuncture, percutaneous electrical nerve stimulation, and percutaneous neuromodulation therapy. RESULTS: Twelve randomized controlled trials including 700 patients were included in the analysis. The efficacy of TENS was similar to that of control treatment for providing pain relief (standardized difference in means [SDM] = -0.20; 95% confidence interval [CI], -0.58 to 0.18; P = 0.293). Other types of NSTs were more effective than TENS in providing pain relief (SDM = 0.86; 95% CI, 0.15-1.57; P = 0.017). Transcutaneous electrical nerve stimulation was more effective than control treatment in improving functional disability only in patients with follow-up of less than 6 weeks (SDM = -1.24; 95% CI, -1.83 to -0.65; P < 0.001). There was no difference in functional disability outcomes between TENS and other NSTs. CONCLUSIONS: These results suggest that TENS does not improve symptoms of lower back pain, but may offer short-term improvement of functional disability.


Asunto(s)
Dolor Crónico/terapia , Dolor de la Región Lumbar/terapia , Dimensión del Dolor/métodos , Estimulación Eléctrica Transcutánea del Nervio/métodos , Dolor Crónico/diagnóstico , Humanos , Dolor de la Región Lumbar/diagnóstico , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos
18.
PLoS One ; 12(11): e0188034, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29145437

RESUMEN

Interbody fusion with posterior instrumentation is a common method for treating lumbar degenerative disc diseases. However, the high rigidity of the fusion construct may produce abnormal stresses at the adjacent segment and lead to adjacent segment degeneration (ASD). As such, biodegradable implants are becoming more popular for use in orthopaedic surgery. These implants offer sufficient stability for fusion but at a reduced stiffness. Tailored to degrade over a specific timeframe, biodegradable implants could potentially mitigate the drawbacks of conventional stiff constructs and reduce the loading on adjacent segments. Six finite element models were developed in this study to simulate a spine with and without fixators. The spinal fixators used both titanium rods and biodegradable rods. The models were subjected to axial loading and pure moments. The range of motion (ROM), disc stresses, and contact forces of facet joints at adjacent segments were recorded. A 3-point bending test was performed on the biodegradable rods and a dynamic bending test was performed on the spinal fixators according to ASTM F1717-11a. The finite element simulation showed that lumbar spinal fusion using biodegradable implants had a similar ROM at the fusion level as at adjacent levels. As the rods degraded over time, this produced a decrease in the contact force at adjacent facet joints, less stress in the adjacent disc and greater loading on the anterior bone graft region. The mechanical tests showed the initial average fatigue strength of the biodegradable rods was 145 N, but this decreased to 115N and 55N after 6 months and 12 months of soaking in solution. Also, both the spinal fixator with biodegradable rods and with titanium rods was strong enough to withstand 5,000,000 dynamic compression cycles under a 145 N axial load. The results of this study demonstrated that biodegradable rods may present more favourable clinical outcomes for lumbar fusion. These polymer rods could not only provide sufficient initial stability, but the loss in rigidity of the fixation construct over time gradually transfers loading to adjacent segments.


Asunto(s)
Materiales Biocompatibles , Fusión Vertebral/instrumentación , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Humanos , Técnicas In Vitro , Rango del Movimiento Articular , Fusión Vertebral/métodos
19.
Spine J ; 17(9): 1373-1380, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28645672

RESUMEN

BACKGROUND CONTEXT: Minimally invasive spine surgery has become increasingly popular in clinical practice, and it offers patients the potential benefits of reduced blood loss, wound pain, and infection risk, and it also diminishes the loss of working time and length of hospital stay. However, surgeons require more intraoperative fluoroscopy and ionizing radiation exposure during minimally invasive spine surgery for localization, especially for guidance in instrumentation placement. In addition, computer navigation is not accessible in some facility-limited institutions. PURPOSE: This study aimed to demonstrate a method for percutaneous screws placement using only the anterior-posterior (AP) trajectory of intraoperative fluoroscopy. STUDY DESIGN: A technical report (a retrospective and prospective case series) was carried out. PATIENT SAMPLE: Patients who received posterior fixation with percutaneous pedicle screws for thoracolumbar degenerative disease or trauma comprised the patient sample. METHOD: We retrospectively reviewed the charts of consecutive 670 patients who received 4,072 pedicle screws between December 2010 and August 2015. Another case series study was conducted prospectively in three additional hospitals, and 88 consecutive patients with 413 pedicle screws were enrolled from February 2014 to July 2016. The fluoroscopy shot number and radiation dose were recorded. In the prospective study, 78 patients with 371 screws received computed tomography at 3 months postoperatively to evaluate the fusion condition and screw positions. RESULTS: In the retrospective series, the placement of a percutaneous screw required 5.1 shots (2-14, standard deviation [SD]=2.366) of AP fluoroscopy. One screw was revised because of a medialwall breach of the pedicle. In the prospective series, 5.8 shots (2-16, SD=2.669) were required forone percutaneous pedicle screw placement. There were two screws with a Grade 1 breach (8.6%), both at the lateral wall of the pedicle, out of 23 screws placed at the thoracic spine at T9-T12. Forthe lumbar and sacral areas, there were 15 Grade 1 breaches (4.3%), 1 Grade 2 breach (0.3%), and 1 Grade 3 breach (0.3%). No revision surgery was necessary. CONCLUSION: This method avoids lateral shots of fluoroscopy during screw placement and thus decreases the operation time and exposes surgeons to less radiation. At the same time, compared with the computer-navigated procedure, it is less facility-demanding, and provides satisfactory reliability and accuracy.


Asunto(s)
Fluoroscopía/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Tornillos Pediculares/efectos adversos , Complicaciones Posoperatorias/epidemiología , Fusión Vertebral/métodos , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Vértebras Lumbares/cirugía , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Tempo Operativo , Complicaciones Posoperatorias/etiología , Reoperación , Fusión Vertebral/efectos adversos , Cirugía Asistida por Computador/efectos adversos
20.
Clin Biomech (Bristol, Avon) ; 43: 115-120, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28259005

RESUMEN

BACKGROUND DATA: Combined usage of posterior lumbar interbody fusion and transpedicular fixation has been extensively used to treat the various lumbar degenerative disc diseases. The transpedicular fixator aims to increase stability and enhance the fusion rate. However, how the fused disc and bridged vertebrae respectively affect adjacent-segment diseases progression is not yet clear. METHODS: Using a validated lumbosacral finite-element model, three variations at the L4-L5 segment were analyzed: 1) moderate disc degeneration, 2) instrumented with a stand-alone cage and pedicle screw fixators, and 3) with the cage only after fusion. The intersegmental angles, disc stresses, and facet loads were examined. Four motion tests, flexion, extension, bending, and twisting, were also simulated. FINDINGS: The adjacent-segment disease was more severe at the cephalic segment than the caudal segment. After solid fusion and fixation, the increase in intersegmental angles, disc stresses and facet loads of the adjacent segments were about 57.6%, 47.3%, and 59.6%, respectively. However, these changes were reduced to 30.1%, 22.7%, and 27.0% after removal of the fixators. This was attributed to the differences between the biomechanical characteristics of the fusion and fixation mechanisms. INTERPRETATION: Fixation superimposes a stiffer constraint on the mobility of the bridged segment than fusion. The current study suggested that the removal of spinal fixators after complete fusion could decrease the stress at adjacent segments. Through a minimally invasive procedure, we could reduce secondary damage to the paraspinal structures while removing the fixators, which is of utmost concern to surgeons.


Asunto(s)
Remoción de Dispositivos , Degeneración del Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Sacro/cirugía , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Fenómenos Biomecánicos , Progresión de la Enfermedad , Análisis de Elementos Finitos , Humanos , Fijadores Internos , Degeneración del Disco Intervertebral/fisiopatología , Tornillos Pediculares , Rango del Movimiento Articular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA