Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Asunto principal
Intervalo de año de publicación
1.
Echocardiography ; 40(8): 775-783, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37351556

RESUMEN

AIM: we sought to test the inter-center reproducibility of 16 echo laboratories involved in the EACVI-Afib Echo Europe. METHODS: This was done on a dedicated setting of 10 patients with sinus rhythm (SR) and 10 with persistent atrial fibrillation (AF), collected by the Principal Investigator. Images and loops of echo-exams were stored and made available for labs. The tested measurements included main echo-Doppler parameters, global longitudinal strain (GLS) and peak atrial longitudinal strain (PALS). RESULTS: Single measures interclass correlation coefficients (ICCs) of left ventricular mass and ejection fraction were suboptimal in both patients with SR and AF. Among diastolic parameters, ICCs of deceleration time were poor, in particular in AF (=.50). ICCs of left atrial size and function, besides optimal in AF, showed an acceptable despite moderate concordance in SR. ICC of GLS was .81 and .78 in SR and AF respectively. ICCs of PALS were suitable but lower in 4-chamber than in 2-chamber view. By depicting the boxplot of the 16 laboratories, GLS distribution was completely homogeneous in SR, whereas GLS of AF and PALS of both SR and AF presented a limited number of outliers. GLS mean ± SE of the 16 labs was 19.7 ± .36 (95% CI: 18.8-20.4) in SR and 16.5 ± .29 (95% CI: 15.9-17.1) in AF, whereas PALS mean ± SE was 43.8 ± .70 (95% CI: 42.3-45.3) and 10.2 ± .32 (95% CI: 9.5-10.9) respectively. CONCLUSION: While the utilization of some standard-echo variables should be discouraged in registries, the application of GLS and PALS could be largely promoted because their superior reproducibility, even in AF.


Asunto(s)
Fibrilación Atrial , Humanos , Reproducibilidad de los Resultados , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Sistema de Registros
2.
J Cardiovasc Echogr ; 25(2): 57-59, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-28465933

RESUMEN

Anomalous mitral arcade is a rare congenital anomaly affecting the mitral tensor apparatus. This condition causes a restrictive movement of the leaflets and interferes with the normal closure of the valve during ventricular systole. We report a case of a 15-year-old female with this condition and initial left ventricular dysfunction, who successfully underwent mitral valve repair. This reparative technique is more technically challenging then valve replacement and only few cases are described in literature.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA