1.
Eur Radiol ; 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39379708

RESUMEN

OBJECTIVES: This study by the EUSOBI International Breast Diffusion-weighted Imaging (DWI) working group aimed to evaluate the current and future applications of advanced DWI in breast imaging. METHODS: A literature search and a comprehensive survey of EUSOBI members to explore the clinical use and potential of advanced DWI techniques and a literature search were involved. Advanced DWI approaches such as intravoxel incoherent motion (IVIM), diffusion kurtosis imaging (DKI), and diffusion tensor imaging (DTI) were assessed for their current status and challenges in clinical implementation. RESULTS: Although a literature search revealed an increasing number of publications and growing academic interest in advanced DWI, the survey revealed limited adoption of advanced DWI techniques among EUSOBI members, with 32% using IVIM models, 17% using non-Gaussian diffusion techniques for kurtosis analysis, and only 8% using DTI. A variety of DWI techniques are used, with IVIM being the most popular, but less than half use it, suggesting that the study identified a gap between the potential benefits of advanced DWI and its actual use in clinical practice. CONCLUSION: The findings highlight the need for further research, standardization and simplification to transition advanced DWI from a research tool to regular practice in breast imaging. The study concludes with guidelines and recommendations for future research directions and clinical implementation, emphasizing the importance of interdisciplinary collaboration in this field to improve breast cancer diagnosis and treatment. CLINICAL RELEVANCE STATEMENT: Advanced DWI in breast imaging, while currently in limited clinical use, offers promising improvements in diagnosis, staging, and treatment monitoring, highlighting the need for standardized protocols, accessible software, and collaborative approaches to promote its broader integration into routine clinical practice. KEY POINTS: Increasing number of publications on advanced DWI over the last decade indicates growing research interest. EUSOBI survey shows that advanced DWI is used primarily in research, not extensively in clinical practice. More research and standardization are needed to integrate advanced DWI into routine breast imaging practice.

2.
Eur J Radiol ; 181: 111730, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39303393

RESUMEN

PURPOSE: Ongoing efforts are focusing on optimizing diffusion-weighted imaging (DWI) as an essential part of breast MRI protocol. Our study aimed to evaluate the effect of contrast media (CM) on the apparent diffusion coefficients (ADC) acquired following current recommendations. PATIENT AND METHODS: Patients who underwent 3 T breast MRI with a histologically verified suspicious lesion were included in this IRB-approved, single-center, cross-sectional retrospective study. Breast MRI protocol included a DWI sequence with multiple b-values, which was acquired before and after CM administration. ADC maps were calculated by in-line monoexponential fitting with b-values 0 /800 and 50/800. Two independent readers (R1, R2) reviewed the images in separate sessions for b values 0/800 and 50/800, pre- and post-CM. Bland Altmann plots as well as intraclass correlation coefficients (ICCs) for inter-reader agreement, different b-values, and pre- and post-CM were calculated. Diagnostic accuracy was evaluated and compared by calculating the area under the receiver operating characteristics curve (AUC). RESULTS: 91 lesions in 89 patients were examined (mean age 50.7 years, standard deviation 13.9). ADC values were significantly (P<0.05) lower post-CM (mean ranging from 1.28 x10-3 mm2/s to 1.30 x10-3 mm2/s) compared to pre-CM (mean ranging from 1.32 x10-3 mm2/s to 1.37 x10-3 mm2/s) for both b-values combinations (0/800 and 50/800 s/mm2). We found an almost perfect inter-reader agreement pre-/post-CM with b values 0/800 and 50/800 (ICC ranging from 0.853 to 0.939). Bland Altman plot demonstrated no systematic difference between readers. ROC analysis revealed good diagnostic performance without significant differences (P>0.05) between b values 0/800 and 50/800 s/mm2 as well as pre- and post-CM with areas under the ROC curve between 0.834 and 0.877. CONCLUSION: ADC values are slightly lower when acquiring b values 0/800 and post-CM. This effect does not reduce the diagnostic performance but may be relevant in case of definite cut-offs in medical decision making.

4.
Eur J Radiol ; 178: 111649, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39094464

RESUMEN

PURPOSE: To create a simple model using standard BI-RADS® descriptors from pre-treatment B-mode ultrasound (US) combined with clinicopathological tumor features, and to assess the potential of the model to predict the presence of residual tumor after neoadjuvant chemotherapy (NAC) in breast cancer (BC) patients. METHOD: 245 female BC patients receiving NAC between January 2017 and December 2019 were included in this retrospective study. Two breast imaging fellows independently evaluated representative B-mode tumor images from baseline US. Additional clinicopathological tumor features were retrieved. The dataset was split into 170 training and 83 validation cases. Logistic regression was used in the training set to identify independent predictors of residual disease post NAC and to create a model, whose performance was evaluated by ROC curve analysis in the validation set. The reference standard was postoperative histology to determine the absence (pathological complete response, pCR) or presence (non-pCR) of residual invasive tumor in the breast or axillary lymph nodes. RESULTS: 100 patients (40.8%) achieved pCR. Logistic regression demonstrated that tumor size, microlobulated margin, spiculated margin, the presence of calcifications, the presence of edema, HER2-positive molecular subtype, and triple-negative molecular subtype were independent predictors of residual disease. A model using these parameters demonstrated an area under the ROC curve of 0.873 in the training and 0.720 in the validation set for the prediction of residual tumor post NAC. CONCLUSIONS: A simple model combining standard BI-RADS® descriptors from pre-treatment B-mode breast US with clinicopathological tumor features predicts the presence of residual disease after NAC.


Asunto(s)
Neoplasias de la Mama , Terapia Neoadyuvante , Neoplasia Residual , Ultrasonografía Mamaria , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/patología , Neoplasias de la Mama/terapia , Neoplasia Residual/diagnóstico por imagen , Persona de Mediana Edad , Ultrasonografía Mamaria/métodos , Estudios Retrospectivos , Adulto , Anciano , Quimioterapia Adyuvante , Valor Predictivo de las Pruebas , Mama/diagnóstico por imagen , Mama/patología
6.
Magn Reson Med Sci ; 2024 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-39010211

RESUMEN

PURPOSE: Gadolinium-based contrast media (GBCM) may affect apparent diffusion coefficient measurements on diffusion-weighted imaging. We aimed at investigating the effect of GBCM and inter-reader variation on intravoxel incoherent motion (IVIM) parameters in breast lesions. METHODS: A total of 89 patients referred to 3T breast MRI with at least one histologically verified lesion were included. IVIM data were acquired using a single-shot echo planar imaging sequence before and after GBCM administration. D (true diffusion coefficient), D* (pseudo-diffusion coefficient) and f (perfusion fraction) were calculated and measured by two readers (R1, R2). Inter-reader and intra-reader agreements were assessed by intraclass correlation coefficients (ICCs) and Bland-Altman plots. RESULTS: D was comparable before and after GBCM administration and between readers. D* and f decreased after GBCM administration and showed a lower agreement between readers. Intra-reader agreement before and after GBCM administration was almost perfect for D for both R1 and R2 (ICC 0.955 and 0.887). The intra-reader agreement was substantial to moderate for D* (ICC R1 0.708, R2 0.583) and moderate for f (ICC R1 0.529 and R2 0.425). Inter-reader agreement before GBCM administration was almost perfect for D (ICC 0.905), substantial for D* (ICC 0.733), and moderate for f (ICC 0.404); after contrast media administration, it was almost perfect for D (ICC 0.876) and substantial for D* (ICC 0.654) and f (ICC 0.606). Bland-Altman plots revealed no significant bias. CONCLUSION: Administration of GBCM seems to have a stronger effect on D* and f values than on D values. This should be considered when applying IVIM in clinical practice.

7.
Eur Radiol ; 34(10): 6348-6357, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38656711

RESUMEN

Breast cancer is the most frequently diagnosed cancer in women accounting for about 30% of all new cancer cases and the incidence is constantly increasing. Implementation of mammographic screening has contributed to a reduction in breast cancer mortality of at least 20% over the last 30 years. Screening programs usually include all women irrespective of their risk of developing breast cancer and with age being the only determining factor. This approach has some recognized limitations, including underdiagnosis, false positive cases, and overdiagnosis. Indeed, breast cancer remains a major cause of cancer-related deaths in women undergoing cancer screening. Supplemental imaging modalities, including digital breast tomosynthesis, ultrasound, breast MRI, and, more recently, contrast-enhanced mammography, are available and have already shown potential to further increase the diagnostic performances. Use of breast MRI is recommended in high-risk women and women with extremely dense breasts. Artificial intelligence has also shown promising results to support risk categorization and interval cancer reduction. The implementation of a risk-stratified approach instead of a "one-size-fits-all" approach may help to improve the benefit-to-harm ratio as well as the cost-effectiveness of breast cancer screening. KEY POINTS: Regular mammography should still be considered the mainstay of the breast cancer screening. High-risk women and women with extremely dense breast tissue should use MRI for supplemental screening or US if MRI is not available. Women need to participate actively in the decision to undergo personalized screening. KEY RECOMMENDATIONS: Mammography is an effective imaging tool to diagnose breast cancer in an early stage and to reduce breast cancer mortality (evidence level I). Until more evidence is available to move to a personalized approach, regular mammography should be considered the mainstay of the breast cancer screening. High-risk women should start screening earlier; first with yearly breast MRI which can be supplemented by yearly or biennial mammography starting at 35-40 years old (evidence level I). Breast MRI screening should be also offered to women with extremely dense breasts (evidence level I). If MRI is not available, ultrasound can be performed as an alternative, although the added value of supplemental ultrasound regarding cancer detection remains limited. Individual screening recommendations should be made through a shared decision-making process between women and physicians.


Asunto(s)
Neoplasias de la Mama , Detección Precoz del Cáncer , Imagen por Resonancia Magnética , Mamografía , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Tamizaje Masivo/métodos , Medición de Riesgo/métodos , Ultrasonografía Mamaria/métodos
8.
Insights Imaging ; 15(1): 92, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38530547

RESUMEN

OBJECTIVES: To collect real-world data about the knowledge and self-perception of young radiologists concerning the use of contrast media (CM) and the management of adverse drug reactions (ADR). METHODS: A survey (29 questions) was distributed to residents and board-certified radiologists younger than 40 years to investigate the current international situation in young radiology community regarding CM and ADRs. Descriptive statistics analysis was performed. RESULTS: Out of 454 respondents from 48 countries (mean age: 31.7 ± 4 years, range 25-39), 271 (59.7%) were radiology residents and 183 (40.3%) were board-certified radiologists. The majority (349, 76.5%) felt they were adequately informed regarding the use of CM. However, only 141 (31.1%) received specific training on the use of CM and 82 (18.1%) about management ADR during their residency. Although 266 (58.6%) knew safety protocols for handling ADR, 69.6% (316) lacked confidence in their ability to manage CM-induced ADRs and 95.8% (435) expressed a desire to enhance their understanding of CM use and handling of CM-induced ADRs. Nearly 300 respondents (297; 65.4%) were aware of the benefits of contrast-enhanced ultrasound, but 249 (54.8%) of participants did not perform it. The preferred CM injection strategy in CT parenchymal examination and CT angiography examination was based on patient's lean body weight in 318 (70.0%) and 160 (35.2%), a predeterminate fixed amount in 79 (17.4%) and 116 (25.6%), iodine delivery rate in 26 (5.7%) and 122 (26.9%), and scan time in 31 (6.8%) and 56 (12.3%), respectively. CONCLUSION: Training in CM use and management ADR should be implemented in the training of radiology residents. CRITICAL RELEVANCE STATEMENT: We highlight the need for improvement in the education of young radiologists regarding contrast media; more attention from residency programs and scientific societies should be focused on training about contrast media use and the management of adverse drug reactions. KEY POINTS: • This survey investigated training of young radiologists about use of contrast media and management adverse reactions. • Most young radiologists claimed they did not receive dedicated training. • An extreme heterogeneity of responses was observed about contrast media indications/contraindications and injection strategy.

9.
Magn Reson Imaging ; 110: 1-6, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38479541

RESUMEN

PURPOSE: This pilot-study aims to assess, whether quantitatively assessed enhancing breast tissue as a percentage of the entire breast volume can serve as an indicator of breast cancer at breast MRI and whether the contrast-agent employed affects diagnostic efficacy. MATERIALS: This retrospective IRB-approved study, included 39 consecutive patients, that underwent two subsequent breast MRI exams for suspicious findings at conventional imaging with 0.1 mmol/kg gadobenic and gadoteric acid. Two independent readers, blinded to the histopathological outcome, assessed unenhanced and early post-contrast images using computer-assisted software (Brevis, Siemens Healthcare). Diagnostic performance was statistically determined for percentage of ipsilateral voxel volume enhancement and for percentage of contralateral enhancing voxel volume subtracted from ipsilateral enhancing voxel volume after crosstabulation with the dichotomized histological outcome (benign/malignant). RESULTS: Ipsilateral enhancing voxel volume versus histopathological outcome resulted in an AUC of 0.707 and 0.687 for gadobenic acid, reader 1 and 2, respectively and in an AUC of 0.778 and 0.773 for gadoteric acid, reader 1 and 2, respectively. Accounting for background parenchymal enhancement by subtracting contralateral enhancing volume from ipsilateral enhancing voxel volume versus histolopathological outcome resulted in an AUC of 0.793 and 0.843 for gadobenic acid, reader 1 and 2, respectively and in an AUC of 0.692 and 0.662 for gadoteric acid, reader 1 and 2, respectively. Pairwise testing yielded no statistically significant difference both between readers and between contrast agents employed (p > 0.05). CONCLUSION: Our proposed CAD algorithm, which quantitatively assesses enhancing breast tissue as a percentage of the entire breast volume, allows indicating the presence of breast cancer.


Asunto(s)
Neoplasias de la Mama , Mama , Medios de Contraste , Imagen por Resonancia Magnética , Compuestos Organometálicos , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Proyectos Piloto , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Adulto , Estudios Retrospectivos , Anciano , Mama/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Meglumina/análogos & derivados , Reproducibilidad de los Resultados , Algoritmos , Sensibilidad y Especificidad
10.
Curr Med Imaging ; 20: e15734056274670, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38415477

RESUMEN

In the world, breast cancer is the most commonly diagnosed cancer among women. Currently, MRI is the most sensitive breast imaging method for detecting breast cancer, although false positive rates are still an issue. To date, the accuracy of breast MRI is widely recognized across various clinical scenarios, in particular, staging of known cancer, screening for breast cancer in high-risk women, and evaluation of response to neoadjuvant chemotherapy. Since technical development and further clinical indications have expanded over recent years, dedicated breast radiologists need to constantly update their knowledge and expertise to remain confident and maintain high levels of diagnostic performance in breast MRI. This review aims to detail current and future applications of breast MRI, from technological requirements and advances to new multiparametric and abbreviated protocols, and ultrafast imaging, as well as current and future indications.


Asunto(s)
Neoplasias de la Mama , Imagen por Resonancia Magnética , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Imagen por Resonancia Magnética/métodos , Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Estadificación de Neoplasias
11.
Eur Radiol ; 34(8): 5439-5450, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38227202

RESUMEN

OBJECTIVES: To perform a survey among members of the European Society of Breast Imaging (EUSOBI) regarding the use of contrast-enhanced mammography (CEM). METHODS: A panel of nine board-certified radiologists developed a 29-item online questionnaire, distributed to all EUSOBI members (inside and outside Europe) from January 25 to March 10, 2023. CEM implementation, examination protocols, reporting strategies, and current and future CEM indications were investigated. Replies were exploratively analyzed with descriptive and non-parametric statistics. RESULTS: Among 434 respondents (74.9% from Europe), 50% (217/434) declared to use CEM, 155/217 (71.4%) seeing less than 200 CEMs per year. CEM use was associated with academic settings and high breast imaging workload (p < 0.001). The lack of CEM adoption was most commonly due to the perceived absence of a clinical need (65.0%) and the lack of resources to acquire CEM-capable systems (37.3%). CEM protocols varied widely, but most respondents (61.3%) had already adopted the 2022 ACR CEM BI-RADS® lexicon. CEM use in patients with contraindications to MRI was the most common current indication (80.6%), followed by preoperative staging (68.7%). Patients with MRI contraindications also represented the most commonly foreseen CEM indication (88.0%), followed by the work-up of inconclusive findings at non-contrast examinations (61.5%) and supplemental imaging in dense breasts (53.0%). Respondents declaring CEM use and higher CEM experience gave significantly more current (p = 0.004) and future indications (p < 0.001). CONCLUSIONS: Despite a trend towards academic high-workload settings and its prevalent use in patients with MRI contraindications, CEM use and progressive experience were associated with increased confidence in the technique. CLINICAL RELEVANCE STATEMENT: In this first survey on contrast-enhanced mammography (CEM) use and perspectives among the European Society of Breast Imaging (EUSOBI) members, the perceived absence of a clinical need chiefly drove the 50% CEM adoption rate. CEM adoption and progressive experience were associated with more extended current and future indications. KEY POINTS: • Among the 434 members of the European Society of Breast Imaging who completed this survey, 50% declared to use contrast-enhanced mammography in clinical practice. • Due to the perceived absence of a clinical need, contrast-enhanced mammography (CEM) is still prevalently used as a replacement for MRI in patients with MRI contraindications. • The number of current and future CEM indications marked by respondents was associated with their degree of CEM experience.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Mamografía , Sociedades Médicas , Humanos , Mamografía/métodos , Europa (Continente) , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Encuestas y Cuestionarios , Pautas de la Práctica en Medicina/estadística & datos numéricos
12.
Br J Radiol ; 97(1155): 560-566, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38265303

RESUMEN

OBJECTIVES: Quality assurance of breast imaging has a long history of using test objects to optimize and follow up imaging devices. In particular, the evaluation of new techniques benefits from suitable test objects. The applicability of a phantom consisting of spiculated masses to assess image quality and its dependence on dose in flat field digital mammography (FFDM) and digital breast tomosynthesis systems (DBT) is investigated. METHODS: Two spiculated masses in five different sizes each were created from a database of clinical tumour models. The masses were produced using 3D printing and embedded into a cuboid phantom. Image quality is determined by the number of spicules identified by human observers. RESULTS: The results suggest that the effect of dose on spicule detection is limited especially in cases with smaller objects and probably hidden by the inter-reader variability. Here, an average relative inter-reader variation of the counted number of 31% was found (maximum 83%). The mean relative intra-reader variability was found to be 17%. In DBT, sufficiently good results were obtained only for the largest masses. CONCLUSIONS: It is possible to integrate spiculated masses into a cuboid phantom. It is easy to print and should allow a direct and prompt evaluation of the quality status of the device by counting visible spicules. Human readout presented the major uncertainty in this study, indicating that automated readout may improve the reproducibility and consistency of the results considerably. ADVANCES IN KNOWLEDGE: A cuboid phantom including clinical objects as spiculated lesion models for visual assessing the image quality in FFDM and DBT was developed and is introduced in this work. The evaluation of image quality works best with the two larger masses with 21 spicules.


Asunto(s)
Neoplasias de la Mama , Mamografía , Humanos , Femenino , Reproducibilidad de los Resultados , Mamografía/métodos , Mama/diagnóstico por imagen , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Neoplasias de la Mama/diagnóstico por imagen
13.
NMR Biomed ; 37(2): e5054, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37794648

RESUMEN

The aim of the current study was to compare the performance of fully automated software with human expert interpretation of single-voxel proton magnetic resonance spectroscopy (1H-MRS) spectra in the assessment of breast lesions. Breast magnetic resonance imaging (MRI) (including contrast-enhanced T1-weighted, T2-weighted, and diffusion-weighted imaging) and 1H-MRS images of 74 consecutive patients were acquired on a 3-T positron emission tomography-MRI scanner then automatically imported into and analyzed by SpecTec-ULR 1.1 software (LifeTec Solutions GmbH). All ensuing 117 spectra were additionally independently analyzed and interpreted by two blinded radiologists. Histopathology of at least 24 months of imaging follow-up served as the reference standard. Nonparametric Spearman's correlation coefficients for all measured parameters (signal-to-noise ratio [SNR] and integral of total choline [tCho]), Passing and Bablok regression, and receiver operating characteristic analysis, were calculated to assess test diagnostic performance, as well as to compare automated with manual reading. Based on 117 spectra of 74 patients, the area under the curve for tCho SNR and integrals ranged from 0.768 to 0.814 and from 0.721 to 0.784 to distinguish benign from malignant tissue, respectively. Neither method displayed significant differences between measurements (automated vs. human expert readers, p > 0.05), in line with the results from the univariate Spearman's rank correlation coefficients, as well as the Passing and Bablok regression analysis. It was concluded that this pilot study demonstrates that 1H-MRS data from breast MRI can be automatically exported and interpreted by SpecTec-ULR 1.1 software. The diagnostic performance of this software was not inferior to human expert readers.


Asunto(s)
Neoplasias de la Mama , Colina , Humanos , Femenino , Espectroscopía de Protones por Resonancia Magnética , Colina/análisis , Proyectos Piloto , Sensibilidad y Especificidad , Mama/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología
14.
Eur Radiol ; 2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-38008743

RESUMEN

OBJECTIVES: To compare image quality of diffusion-weighted imaging (DWI) and contrast-enhanced breast MRI (DCE-T1) stratified by the amount of fibroglandular tissue (FGT) as a measure of breast density. METHODS: Retrospective, multi-reader, bicentric visual grading analysis study on breast density (A-D) and overall image and fat suppression quality of DWI and DCE-T1, scored on a standard 5-point Likert scale. Cross tabulations and visual grading characteristic (VGC) curves were calculated for fatty breasts (A/B) versus dense breasts (C/D). RESULTS: Image quality of DWI was higher in the case of increased breast density, with good scores (score 3-5) in 85.9% (D) and 88.4% (C), compared to 61.6% (B) and 53.5% (A). Overall image quality of DWI was in favor of dense breasts (C/D), with an area under the VGC curve of 0.659 (p < 0.001). Quality of DWI and DCE-T1 fat suppression increased with higher breast density, with good scores (score 3-5) for 86.9% and 45.7% of density D, and 90.2% and 42.9% of density C cases, compared to 76.0% and 33.6% for density B and 54.7% and 29.6% for density A (DWI and DCE-T1 respectively). CONCLUSIONS: Dense breasts show excellent fat suppression and substantially higher image quality in DWI images compared with non-dense breasts. These results support the setup of studies exploring DWI-based MR imaging without IV contrast for additional screening of women with dense breasts. CLINICAL RELEVANCE STATEMENT: Our findings demonstrate that image quality of DWI is robust in women with an increased amount of fibroglandular tissue, technically supporting the feasibility of exploring applications such as screening of women with mammographically dense breasts. KEY POINTS: • Image and fat suppression quality of diffusion-weighted imaging are dependent on the amount of fibroglandular tissue (FGT) which is closely connected to breast density. • Fat suppression quality in diffusion-weighted imaging of the breast is best in women with a high amount of fibroglandular tissue. • High image quality of diffusion-weighted imaging in women with a high amount of FGT in MRI supports that the technical feasibility of DWI can be explored in the additional screening of women with mammographically dense breasts.

15.
Eur Radiol ; 2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-37999727

RESUMEN

OBJECTIVES: To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS: The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS: Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS: Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT: When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS: • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.

16.
Eur J Radiol ; 169: 111185, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37939606

RESUMEN

PURPOSE: We investigated the added value of two internationally used clinical decision rules in the management of enhancing lesions on breast MRI. METHODS: This retrospective, institutional review board approved study included consecutive patients from two different populations. Patients received breast MRI according to the recommendations of the European Society of Breast Imaging (EUSOBI). Initially, all examinations were assessed by expert readers without using clinical decision rules. All lesions rated as category 4 or 5 according to the Breast Imaging Reporting and Data System were histologically confirmed. These lesions were re-evaluated by an expert reader blinded to the histology. He assigned each lesion a Göttingen score (GS) and a Kaiser score (KS) on different occasions. To provide an estimate on inter-reader agreement, a second fellowship-trained reader assessed a subset of these lesions. Subgroup analyses based on lesion type (mass vs. non-mass), size (>1 cm vs. ≤ 1 cm), menopausal status, and significant background parenchymal enhancement were conducted. The areas under the ROC curves (AUCs) for the GS and KS were compared, and the potential to avoid unnecessary biopsies was determined according to previously established cutoffs (KS > 4, GS > 3) RESULTS: 527 lesions in 506 patients were included (mean age: 51.8 years, inter-quartile-range: 43.0-61.0 years). 131/527 lesions were malignant (24.9 %; 95 %-confidence-interval: 21.3-28.8). In all subgroups, the AUCs of the KS (median = 0.91) were higher than those of the GS (median = 0.83). Except for "premenopausal patients" (p = 0.057), these differences were statistically significant (p ≤ 0.01). Kappa agreement was higher for the KS (0.922) than for the GS (0.358). CONCLUSION: Both the KS and the GS provided added value for the management of enhancing lesions on breast MRI. The KS was superior to the GS in terms of avoiding unnecessary biopsies and showed superior inter-reader agreement; therefore, it may be regarded as the clinical decision rule of choice.


Asunto(s)
Neoplasias de la Mama , Reglas de Decisión Clínica , Masculino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Mama/diagnóstico por imagen , Mama/patología , Biopsia Guiada por Imagen , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Sensibilidad y Especificidad
17.
Cancers (Basel) ; 15(20)2023 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-37894455

RESUMEN

In this prospective study, 117 female patients (mean age = 53 years) with 127 histologically proven breast cancer lesions (lymph node (LN) positive = 85, LN negative = 42) underwent simultaneous 18F-FDG PET/MRI of the breast. Quantitative parameters were calculated from dynamic contrast-enhanced (DCE) imaging (tumor Mean Transit Time, Volume Distribution, Plasma Flow), diffusion-weighted imaging (DWI) (tumor ADCmean), and PET (tumor SUVmax, mean and minimum, SUVmean of ipsilateral breast parenchyma). Manual whole-lesion segmentation was also performed on DCE, T2-weighted, DWI, and PET images, and radiomic features were extracted. The dataset was divided into a training (70%) and a test set (30%). Multi-step feature selection was performed, and a support vector machine classifier was trained and tested for predicting axillary LN status. 13 radiomic features from DCE, DWI, T2-weighted, and PET images were selected for model building. The classifier obtained an accuracy of 79.8 (AUC = 0.798) in the training set and 78.6% (AUC = 0.839), with sensitivity and specificity of 67.9% and 100%, respectively, in the test set. A machine learning-based radiomics model comprising 18F-FDG PET/MRI radiomic features extracted from the primary breast cancer lesions allows high accuracy in non-invasive identification of axillary LN metastasis.

18.
Insights Imaging ; 14(1): 126, 2023 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-37466753

RESUMEN

Axillary lymphadenopathy is a common side effect of COVID-19 vaccination, leading to increased imaging-detected asymptomatic and symptomatic unilateral axillary lymphadenopathy. This has threatened to negatively impact the workflow of breast imaging services, leading to the release of ten recommendations by the European Society of Breast Imaging (EUSOBI) in August 2021. Considering the rapidly changing scenario and data scarcity, these initial recommendations kept a highly conservative approach. As of 2023, according to newly acquired evidence, EUSOBI proposes the following updates, in order to reduce unnecessary examinations and avoid delaying necessary examinations. First, recommendation n. 3 has been revised to state that breast examinations should not be delayed or rescheduled because of COVID-19 vaccination, as evidence from the first pandemic waves highlights how delayed or missed screening tests have a negative effect on breast cancer morbidity and mortality, and that there is a near-zero risk of subsequent malignant findings in asymptomatic patients who have unilateral lymphadenopathy and no suspicious breast findings. Second, recommendation n. 7 has been revised to simplify follow-up strategies: in patients without breast cancer history and no imaging findings suspicious for cancer, symptomatic and asymptomatic imaging-detected unilateral lymphadenopathy on the same side of recent COVID-19 vaccination (within 12 weeks) should be classified as a benign finding (BI-RADS 2) and no further work-up should be pursued. All other recommendations issued by EUSOBI in 2021 remain valid.

19.
Eur Radiol ; 33(11): 8103-8111, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37481690

RESUMEN

OBJECTIVES: Quality assurance (QA) of image interpretation plays a key role in screening and diagnostic mammography, maintaining minimum standards and supporting continuous improvement in interpreting images. However, the QA structure across Europe shows considerable variation. The European Society of Breast Imaging (EUSOBI) conducted a survey among the members to collect information on radiologists' preferences regarding QA measures in mammography. MATERIALS AND METHODS: An anonymous online survey consisting of 25 questions was distributed to all EUSOBI members and national breast radiology bodies in Europe. The questions were designed to collect demographic characteristics, information on responders' mammography workload and data about QA measures currently used in their country. Data was analysed using descriptive statistical analysis, the χ2 test, linear regression, and Durbin-Watson statistic test. RESULTS: In total, 251 breast radiologists from 34 countries completed the survey. Most respondents were providing both screening and symptomatic services (137/251, 54.6%), working in an academic hospital (85/251, 33.9%) and reading 1000-4999 cases per year (109/251, 43.4%). More than half of them (133/251, 53%) had established QA measures in their workplace. Although less than one-third (71/251, 28.3%) had to participate in regular performance testing, the vast majority (190/251, 75.7%) agreed that a mandatory test would be helpful to improve their skills. CONCLUSION: QA measures were in place for more than half of the respondents working in screening and diagnostic mammography to evaluate their breast imaging performance. Although there were substantial differences between countries, the importance of having QA in the workplace and implemented was widely acknowledged by radiologists. CLINICAL RELEVANCE STATEMENT: Although several quality assurance (QA) measures of image interpretation are recommended by European bodies or national organisations, the QA in mammography is quite heterogenous between countries and reporting settings, and not always actively implemented across Europe. KEY POINTS: The first survey that presents radiologists' preferences regarding QA measures of image interpretation in mammography. Quality assurance measures in the workplace are better-established for breast screening compared to diagnostic mammography. Radiologists consider that performance tests would help to improve their mammography interpretation skills.


Asunto(s)
Neoplasias de la Mama , Radiólogos , Humanos , Femenino , Mamografía/métodos , Mama , Encuestas y Cuestionarios , Europa (Continente) , Neoplasias de la Mama/diagnóstico por imagen , Tamizaje Masivo
20.
Eur Radiol ; 33(8): 5400-5410, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37166495

RESUMEN

OBJECTIVES: To develop an intuitive and generally applicable system for the reporting, assessment, and documentation of ADC to complement standard BI-RADS criteria. METHODS: This was a multicentric, retrospective analysis of 11 independently conducted institutional review board-approved studies from seven institutions performed between 2007 and 2019. Breast Apparent Diffusion coefficient (ADC-B) categories comprised ADC-B0 (ADC non-diagnostic), ADC-B1 (no enhancing lesion), and ADC-B2-5. The latter was defined by plotting ADC versus cumulative malignancy rates. Statistics comprised ANOVA with post hoc testing and ROC analysis. p values ≤ 0.05 were considered statistically significant. RESULTS: A total of 1625 patients (age: 55.9 years (± 13.8)) with 1736 pathologically verified breast lesions were included. The mean ADC (× 10-3 mm2/s) differed significantly between benign (1.45, SD .40) and malignant lesions (.95, SD .39), and between invasive (.92, SD .22) and in situ carcinomas (1.18, SD .30) (p < .001). The following ADC-B categories were identified: ADC-B0-ADC cannot be assessed; ADC-B1-no contrast-enhancing lesion; ADC-B2-ADC ≥ 1.9 (cumulative malignancy rate < 0.1%); ADC-B3-ADC 1.5 to < 1.9 (0.1-1.7%); ADC-B4-ADC 1.0 to < 1.5 (10-24.5%); and ADC-B5-ADC < 1.0 (> 24.5%). At the latter threshold, a positive predictive value of 95.8% (95% CI 0.94-0.97) for invasive versus non-invasive breast carcinomas was reached. CONCLUSIONS: The breast apparent diffusion coefficient system (ADC-B) provides a simple and widely applicable categorization scheme for assessment, documentation, and reporting of apparent diffusion coefficient values in contrast-enhancing breast lesions on MRI. CLINICAL RELEVANCE STATEMENT: The ADC-B system, based on diverse MRI examinations, is clinically relevant for stratifying breast cancer risk via apparent diffusion coefficient measurements, and complements BI-RADS for improved clinical decision-making and patient outcomes. KEY POINTS: • The breast apparent diffusion coefficient category system (ADC-B) is a simple tool for the assessment, documentation, and reporting of ADC values in contrast-enhancing breast lesions on MRI. • The categories comprise ADC-B0 for non-diagnostic examinations, ADC-B1 for examinations without an enhancing lesion, and ADC-B2-5 for enhancing lesions with an increasing malignancy rate. • The breast apparent diffusion coefficient category system may be used to complement BI-RADS in clinical decision-making.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Humanos , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Diagnóstico Diferencial , Mama/diagnóstico por imagen , Mama/patología , Imagen de Difusión por Resonancia Magnética , Imagen por Resonancia Magnética , Neoplasias de la Mama/patología , Sensibilidad y Especificidad