Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
2.
Front Neurol ; 14: 1265409, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38111795

RESUMEN

Background: Freezing of gait is a debilitating symptom in Parkinson's disease, during which a sudden motor block prevents someone from moving forward. Remarkably, doorways can provoke freezing. Most research has focused on the influence of doorway width, and little is known about other doorway characteristics influencing doorway freezing. Objective: Firstly, to provide guidelines on how to design doorways for people with freezing. Secondly, to compare people with doorway freezing to people without doorway freezing, and to explore the underlying mechanisms of doorway freezing. Methods: We designed a web-based, structured survey consisting of two parts. Part I (n = 171 responders), open to people with Parkinson's disease with freezing in general, aimed to compare people with doorway freezing to people without doorway freezing. We explored underlying processes related to doorway freezing with the Gait-Specific Attention Profile (G-SAP), inquiring about conscious movement processes occurring during doorway passing. Part II (n = 60), open for people experiencing weekly doorway freezing episodes, inquired about the influence of specific doorway characteristics on freezing. Results: People with doorway freezing (69% of Part I) had higher freezing severity, longer disease duration, and scored higher on all sub scores of the G-SAP (indicating heightened motor, attentional, and emotional thoughts when passing through doorways) than people without doorway freezing. The main categories provoking doorway freezing were: dimensions of the door and surroundings, clutter around the door, lighting conditions, and automatic doors. Conclusion: We provide recommendations on how to maximally avoid freezing in a practical setting. Furthermore, we suggest that doorways trigger freezing based on visuomotor, attentional, and emotional processes.

5.
J Neuroeng Rehabil ; 20(1): 53, 2023 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-37106388

RESUMEN

BACKGROUND: Freezing of gait (FOG) is an unpredictable gait arrest that hampers the lives of 40% of people with Parkinson's disease. Because the symptom is heterogeneous in phenotypical presentation (it can present as trembling/shuffling, or akinesia) and manifests during various circumstances (it can be triggered by e.g. turning, passing doors, and dual-tasking), it is particularly difficult to detect with motion sensors. The freezing index (FI) is one of the most frequently used accelerometer-based methods for FOG detection. However, it might not adequately distinguish FOG from voluntary stops, certainly for the akinetic type of FOG. Interestingly, a previous study showed that heart rate signals could distinguish FOG from stopping and turning movements. This study aimed to investigate for which phenotypes and evoking circumstances the FI and heart rate might provide reliable signals for FOG detection. METHODS: Sixteen people with Parkinson's disease and daily freezing completed a gait trajectory designed to provoke FOG including turns, narrow passages, starting, and stopping, with and without a cognitive or motor dual-task. We compared the FI and heart rate of 378 FOG events to baseline levels, and to stopping and normal gait events (i.e. turns and narrow passages without FOG) using mixed-effects models. We specifically evaluated the influence of different types of FOG (trembling vs akinesia) and triggering situations (turning vs narrow passages; no dual-task vs cognitive dual-task vs motor dual-task) on both outcome measures. RESULTS: The FI increased significantly during trembling and akinetic FOG, but increased similarly during stopping and was therefore not significantly different from FOG. In contrast, heart rate change during FOG was for all types and during all triggering situations statistically different from stopping, but not from normal gait events. CONCLUSION: When the power in the locomotion band (0.5-3 Hz) decreases, the FI increases and is unable to specify whether a stop is voluntary or involuntary (i.e. trembling or akinetic FOG). In contrast, the heart rate can reveal whether there is the intention to move, thus distinguishing FOG from stopping. We suggest that the combination of a motion sensor and a heart rate monitor may be promising for future FOG detection.


Asunto(s)
Trastornos Neurológicos de la Marcha , Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/complicaciones , Enfermedad de Parkinson/diagnóstico , Trastornos Neurológicos de la Marcha/diagnóstico , Trastornos Neurológicos de la Marcha/etiología , Frecuencia Cardíaca , Marcha/fisiología , Movimiento/fisiología , Temblor
6.
Neurophotonics ; 10(2): 023515, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36908680

RESUMEN

Significance: The expansion of functional near-infrared spectroscopy (fNIRS) methodology and analysis tools gives rise to various design and analytical decisions that researchers have to make. Several recent efforts have developed guidelines for preprocessing, analyzing, and reporting practices. For the planning stage of fNIRS studies, similar guidance is desirable. Study preregistration helps researchers to transparently document study protocols before conducting the study, including materials, methods, and analyses, and thus, others to verify, understand, and reproduce a study. Preregistration can thus serve as a useful tool for transparent, careful, and comprehensive fNIRS study design. Aim: We aim to create a guide on the design and analysis steps involved in fNIRS studies and to provide a preregistration template specified for fNIRS studies. Approach: The presented preregistration guide has a strong focus on fNIRS specific requirements, and the associated template provides examples based on continuous-wave (CW) fNIRS studies conducted in humans. These can, however, be extended to other types of fNIRS studies. Results: On a step-by-step basis, we walk the fNIRS user through key methodological and analysis-related aspects central to a comprehensive fNIRS study design. These include items specific to the design of CW, task-based fNIRS studies, but also sections that are of general importance, including an in-depth elaboration on sample size planning. Conclusions: Our guide introduces these open science tools to the fNIRS community, providing researchers with an overview of key design aspects and specification recommendations for comprehensive study planning. As such it can be used as a template to preregister fNIRS studies or merely as a tool for transparent fNIRS study design.

7.
Neuroimage ; 269: 119880, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36693595

RESUMEN

BACKGROUND: functional near-infrared spectroscopy (fNIRS) is an increasingly popular tool to study cortical activity during movement and gait that requires further validation. This study aimed to assess (1) whether fNIRS can detect the difficult-to-measure leg area of the primary motor cortex (M1) and distinguish it from the hand area; and (2) whether fNIRS can differentiate between automatic (i.e., not requiring one's attention) and non-automatic movement processes. Special attention was attributed to systemic artifacts (i.e., changes in blood pressure, heart rate, breathing) which were assessed and corrected by short channels, i.e., fNIRS channels which are mainly sensitive to superficial scalp hemodynamics. METHODS: Twenty-three seated, healthy participants tapped four fingers on a keyboard or tapped the right foot on four squares on the floor in a specific order given by a 12-digit sequence (e.g., 434141243212). Two different sequences were executed: a beforehand learned (i.e., automatic) version and a newly learned (i.e., non-automatic) version. A 36-channel fNIRS device including 12 short channels covered multiple motor-related cortical areas including M1. The fNIRS data were analyzed with a general linear model (GLM). Correlation between the expected functional hemodynamic responses (i.e. task regressor) and the short channels (i.e. nuisance regressors), necessitated performing a separate short channel regression instead of integrating them in the GLM. RESULTS: Consistent with the M1 somatotopy, we found significant HbO increases of very large effect size in the lateral M1 channels during finger tapping (Cohen's d = 1.35, p<0.001) and significant HbO increases of moderate effect size in the medial M1 channels during foot tapping (Cohen's d = 0.8, p<0.05). The cortical activity differences between automatic and non-automatic tasks were not significantly different. Importantly, leg movements produced large systemic fluctuations, which were adequately removed by the use of all available short channels. DISCUSSION: Our results indicate that fNIRS is sensitive to leg activity in M1, though the sensitivity is lower than for finger activity and requires rigorous correction for systemic fluctuations. We furthermore highlight that systemic artifacts may result in an unreliable GLM analysis when short channels show signals that are similar to the expected hemodynamic responses.


Asunto(s)
Corteza Motora , Humanos , Corteza Motora/fisiología , Artefactos , Pierna , Espectroscopía Infrarroja Corta/métodos , Mano/fisiología
8.
Mov Disord Clin Pract ; 9(8): 1099-1104, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36339306

RESUMEN

Background: Freezing of gait, a disabling episodic symptom, is difficult to assess as the exact begin- and endpoint of an episode is not easy to specify. This hampers scientific and clinical progress. The current golden standard is video annotation by two independent raters. However, the comparison of the two ratings gives rise to non-overlapping, gray areas. Objective: To provide a guideline for dealing with these gray areas. Methods/Results: We propose a standardized procedure for handling the gray areas based on two parameters, the tolerance and correction parameter. Furthermore, we recommend the use of positive agreement, negative agreement, and prevalence index to report interrater agreement instead of the commonly used intraclass correlation coefficient or Cohen's kappa. This theoretical guideline was implemented in an open-source practical tool, FOGtool (https://github.com/helenacockx/FOGtool). Conclusion: This paper aims to contribute to the standardization of freezing of gait assessment, thereby improving data sharing procedures and replicability of study results.

9.
Front Neurol ; 11: 185, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32265826

RESUMEN

Background: Turning in place is particularly bothersome for patients with Parkinson's disease (PD) experiencing freezing of gait (FOG). Cues designed to enforce goal-directed turning are not yet available. Objectives: Assess whether augmented reality (AR) visual cues improve FOG and turning in place in PD patients with FOG. Methods: Sixteen PD patients with FOG performed a series of 180° turns under an experimental condition with AR visual cues displayed through a HoloLens and two control conditions (one consisting of auditory cues and one without any cues). FOG episodes were annotated by two independent raters from video recordings. Motion data were measured with 17 inertial measurement units for calculating axial kinematics, scaling, and timing of turning. Results: AR visual cues did not reduce the percent time frozen (p = 0.73) or the number (p = 0.73) and duration (p = 0.78) of FOG episodes compared to the control condition without cues. All FOG parameters were higher with AR visual cues than with auditory cues [percent time frozen (p = 0.01), number (p = 0.02), and duration (p = 0.007) of FOG episodes]. The AR visual cues did reduce the peak angular velocity (visual vs. uncued p = 0.03; visual vs. auditory p = 0.02) and step height (visual vs. uncued p = 0.02; visual vs. auditory p = 0.007), and increased the step height coefficient of variation (visual vs. uncued p = 0.04; visual vs. auditory p = 0.01) and time to maximum head-pelvis separation (visual vs. uncued p = 0.02; visual vs. auditory p = 0.005), compared to both control conditions. Conclusions: The AR visual cues in this study did not reduce FOG, and worsened some measures of axial kinematics, and turn scaling and timing. Stimulating goal-directed turning might, by itself, be insufficient to reduce FOG and improve turning performance. Trial Registration: This study was registered in the Dutch trial registry (NTR6409; 2017-02-16).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA